• 제목/요약/키워드: Laser-Induced Plasma

검색결과 142건 처리시간 0.023초

CU+ ION EXTRACTION FROM A MODIFIED BERNAS ION SOURCE IN A METAL-ION IMPLANTER

  • Hong, In-Seok;Lee, Hwa-Ryun;Trinh, Tu Anh;Cho, Yong-Sub
    • Nuclear Engineering and Technology
    • /
    • 제41권5호
    • /
    • pp.709-714
    • /
    • 2009
  • An ion implanter, which can serve as a metal-ion supply, has been constructed and performance tested. Copper ions are generated and extracted from a Bernas ion source with a heating crucible that provides feed gases to sustain the plasma. Sable arc plasmas can be sustained in the ion source for a crucible temperature in excess of $350^{\circ}C$. Stable extraction of the ions is possible for arc Currents less than 0.3 A. Arc currents increase with the induced power of a block cathode and the transverse field in the ion source. $Cu^+$ ions in the extracted beam are separated using a dipole magnet. A $20{\mu}A$ $Cu^+$ ion current can be extracted with a 0.2 A arc current. The ion current can support a dose of $10^{16}ions/cm^2$ over an area of $15\;cm^2$ within a few hours.

Development of Bio-ballistic Device for Laser Ablation-induced Drug Delivery

  • Choi, Ji-Hee;Gojani, Ardian B.;Lee, Hyun-Hee;Jeung, In-Seuk;Yoh, Jack J.
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권3호
    • /
    • pp.68-71
    • /
    • 2008
  • Transdermal and topical drug delivery with minimal tissue damage has been an area of vigorous research for a number of years. Our research team has initiated the development of an effective method for delivering drug particles across the skin (transdermal) for systemic circulation, and to localized (topical) areas. The device consists of a micro particle acceleration system based on laser ablation that can be integrated with endoscopic surgical techniques. A layer of micro particles is deposited on the surface of a thin metal foil. The rear side of the foil is irradiated with a laser beam, which generates a shockwave that travels through the foil. When the shockwave reaches the end of the foil, it is reflected as an expansion wave and causes instantaneous deformation of the foil in the opposite direction. Due to this sudden deformation, the microparticles are ejected from the foil at very high speeds, and therefore have sufficient momentum to penetrate soft body tissues. We have demonstrated this by successfully delivering cobalt particles $3\;{\mu}m$ in diameter into gelatin models that represent soft tissue with remarkable penetration depth.

Gallium Nitride Nanoparticle Synthesis Using Non-thermal Plasma with N2 Gas

  • 유광호;김정형;유신재;류현;성대진;신용현;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.236.1-236.1
    • /
    • 2014
  • Compounds of Ga, such as gallium oxide (Ga2O3) and gallium nitride (GaN), are of interest due to its unique properties in semiconductor application. In particular, GaN has the potentially application for optoelectronic device such as light-emitting diodes (LEDs) and laser diodes (LDs) [1]. Nanoparticle is an interesting material due to its unique properties compared to the bulk equivalents. In this report, we develop a synthesizing method for gallium nitride nanoparticle using non-thermal plasma. For gallium source, the gallium is heated by thermal conduction of tungsten boat which is heated by eddy current induced from RF current in antenna. Nitrogen source for nanoparticle synthesis are from inductively coupled plasma with N2 gas. The synthesized nano particles are analyzed using field-emission scanning microscope (FESEM), transmission electron microscope (TEM) and x-ray photoelectron spectroscopy (XPS). The synthesized particles are investigated and discussed in wide range of experiment conditions such as flow rate, pressure and RF power.

  • PDF

이동식 레이저 유도 파열 검출 장치를 이용한 KURT 지하수 내 콜로이드 나노 입자 검출 (Detection of Colloidal Nanoparticles in KURT Groundwater by a Mobile Laser-Induced Breakdown Detection System)

  • 정의창;조혜륜;박미리;백민훈
    • 방사성폐기물학회지
    • /
    • 제9권1호
    • /
    • pp.41-48
    • /
    • 2011
  • 한국원자력연구원 내 지하 처분 연구시설(KURT)에서 채취한 지하수에 존재하는 나노 콜로이드 입자의 크기 및 농도를 현상에서 조사하기 위해 이동식 레이저 유도 파열 검출 장치를 개발하였다. 제작한 장치는 CCD 카메라를 이용하여 레이저 유도 플라즈마가 발생한 위치를 2-차원 영상으로 기록함으로써 광학적으로 입자의 크기를 결정할 수 있다. 크기가 정확히 알려진 폴리스틸렌 표준 입자를 이용하여 입자 크기 측정용 검정 곡선 (calibration curve)을 구했고, 이를 이용하여 지하 처분 연구시설에서 채취한 지하수 내 콜로이드 입자의 크기를 측정하였다. 지하수 내 존재하는 콜로이드 입자의 평균 크기는 $108{\pm}26$ nm 임을 보였고, 농도는 50 ppb 이하인 것으로 추정하였다.

레이져 유기형광법을 이용한 펄스 배리어 방전 공간에서의 NO분자에 대한 시·공간적 밀도변화 측정 (A Spatio-Temporal Density Measurement of NO Molecules in Pulsed Barrier Discharge Using Laser Induced Fluorescence)

  • 한상보
    • 조명전기설비학회논문지
    • /
    • 제24권5호
    • /
    • pp.160-168
    • /
    • 2010
  • 본 논문은 대기압 펄스 배리어 방전을 이용하여 NO 가스를 무해한 물질로 환원시키기 위하여 방전공간에서의 NO 분자의 생성 및 제거과정에 대하여 레이져 유기형광법을 이용하여 시 공간적인 밀도변화를 측정 및 분석하였다. 사용된 펄스 배리어 방전리액터는 진전속도가 $2.7{\times}10^6$[m/s] 인 1차 스트리머가 음극표면에 도착한 이후에 2차 스트리머가 양극 부근에 발생되었다. 그리고, 펄스 레이져에 의하여 NO 분자만을 효율적으로 상위준위로 여기시키기 위하여 Nd:Yag 및 염료 레이져를 복합하여 226[nm]의 자외광을 방전공간으로 도입하였으며, NO 분자만을 $A^2{\Sigma}^+{\leftarrow}X^2{\prod}$(0,0)으로 여기시키고, 여기된 분자들이 낮은 준위 $A^2{\Sigma}^+{\rightarrow}X^2{\prod}$(0,2), (0,3)로 복귀됨에 따라 방출되는 주요한 형광신호를 측정하였다. NO 분자의 시 공간적 변화 측정결과로부터 NO 가스를 효율적으로 제거하기 위해서는 산소농도를 가능한 2 [%]이하로 낮추고, 2차 스트리머 진전에 의해서 충분하게 방전공간에서 NO 환원반응을 유발할 수 있도록 제어하는 것이 필요하다고 판단된다.

이상상태 분무 화염에서의 레이저 점화 및 분광 측정을 통한 피드백 제어 연구 (Simultaneous optical ignition and spectroscopy of a two-phase spray flame for feedback control System)

  • 이석환;김현우;도형록;여재익
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.215-218
    • /
    • 2015
  • Simultaneous laser ignition and spectroscopy is a scheme that enables rapid determination of the local equivalence ratio and condensed fuel concentration during a reaction in a two phase spray flame. We have conducted quantitative analysis of the LIBS signals according to the equivalence ratio, droplet size, droplet number density and droplet concentration as a part of novel feedback control strategy proposed for flame ignition and stabilization with simultaneous in situ combustion flow diagnostics. This is a desirable scheme since such real time information onboard an engine for instance can be constantly monitored and fed back to the control loop to enhance the mixing process and minimize emissions of unwanted species and potential combustion instability.

  • PDF

ICCD Camera를 이용한 NO 입자의 Image 관측 (Image Observation of NO Particles Using ICCD camera)

  • 전용우;최준영;최상태;박원주;이광식;신용철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.209-213
    • /
    • 2000
  • In this paper, the removal rate of NO in a reactor is measured first using nonthermal plasma generated from a wire-cylinder type reactor, then the spatial density distribution of NO particles is investigated using ICCD(Intensified Charged Coupled Device) camera. This research uses nonthermal plasma from electrical discharge to analyze the NO characteristics, and the measurements of NO discharge image and Distribution are performed using the ICCD camera to examine the NO characteristics more closely. Furthermore, the method of Laser Induced Fluorescence (LIF) is used to analyze the particular behavior of NO particles more specifically, to suggest a method of reducing exhaust gas, a serious environmental problem.

  • PDF

아연코팅 강판의 CO2 레이저용접시 인프로세스 모니터링을 위한 측정신호와 용접결함과의 관련성 연구 (Study on the Relationship Between Emission Signals and Weld Defect for In-Process Monitoring in CO2 Laser Welding of Zn-Coated Steel)

  • 김종도;이창제
    • 대한기계학회논문집A
    • /
    • 제34권10호
    • /
    • pp.1507-1512
    • /
    • 2010
  • 본 연구에서는 조선용 6mm 아연코팅강판의 $CO_2$ 레이저 겹치기 용접시 발생하는 유기 플라즈마를 마이크로폰과 포토다이오드로 측정하였다. 이때 겹치기 갭간극에 따른 용접조건을 RMS한 신호와 비교 분석하였다. 이를 통해 아연증발량이 증가함에 따라 RMS값도 증가하였으며, 겹침부의 조건에 따라 결함 발생시 RMS의 급격한 변화도 확인할 수 있었다. 또한 용접조건에 따른 Raw signal의 FFT값을 구한 후, 이때 구해진 주파수값을 밴드폭으로 설정하여 Raw signal을 필터링한 뒤의 RMS값을 용접비드와 대응하여 필터링하지 않은 RMS와의 차이점도 비교 분석하였다. 이를 통해 기존의 방법들보다 신뢰성 높은 In-process 모니터링이 가능함을 확인하였다.

Crystallization of Amorphous Silicon Films Using Joule Heating

  • Ro, Jae-Sang
    • 한국표면공학회지
    • /
    • 제47권1호
    • /
    • pp.20-24
    • /
    • 2014
  • Joule heat is generated by applying an electric filed to a conductive layer located beneath or above the amorphous silicon film, and is used to raise the temperature of the silicon film to crystallization temperature. An electric field was applied to an indium tin oxide (ITO) conductive layer to induce Joule heating in order to carry out the crystallization of amorphous silicon. Polycrystalline silicon was produced within the range of a millisecond. To investigate the kinetics of Joule-heating induced crystallization (JIC) solid phase crystallization was conducted using amorphous silicon films deposited by plasma enhanced chemical vapor deposition and using tube furnace in nitrogen ambient. Microscopic and macroscopic uniformity of crystallinity of JIC poly-Si was measured to have better uniformity compared to that of poly-Si produced by other methods such as metal induced crystallization and Excimer laser crystallization.

A Study on the Temporal Behavior of the Wall Voltage in a surface-type AC panel

  • Kim, Jung-Hun;Lee, Jun-Hak;Choi, Young-Wook;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.175-176
    • /
    • 2000
  • Electric fields and the wall voltages in a surface-type AC PDP cell were measured using a Laser Induced Fluorescence Spectroscopy. For the condition of He 100Torr, 200V sustain voltage and 50kHz sustain frequency, the wall voltage dropped from about 50V to about -75V within $1{\mu}sec$ after the main discharge. And the wall voltage decreased with the rate of $10.8V/{\mu}sec$ due to the accumulation of the space charges after $1{\mu}sec$. But when the operating pressure was 40Torr, it increased with the rate of $4.5V/{\mu}sec$ because the diffusion effect of the wall charge on MgO surface was more dominant than the accumulation effect of the space charges. During the pulse-off period, the wall voltage decreased slightly due to the diffusion of the wall charge. When the sustain voltage was 250V, the self-erasing discharge occurred, and the absolute value of the wall voltage decreased rapidly just after the pulses were off, which was caused by the accumulation of the charges generated by the self-erasing discharge.

  • PDF