• Title/Summary/Keyword: Laser-Induced Fluorescence

Search Result 248, Processing Time 0.03 seconds

A Study on the Turbulent Characteristics of Rushton Turbine Mixer by Simultaneous Measurement of Velocity and Concentration field with Stereo-PIV/PLIF Technique (Stereo-PIV/LIF의 속도장과 농도장 동시측정 기법을 이용한 러쉬톤 교반기내 난류특성에 관한 연구)

  • Min, Young-Uk;Kim, Yun-Gi;Kim, Kyung-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.365-370
    • /
    • 2004
  • Simultaneous measurement with PLIF(Planar Laser-Induced Fluorescence) and Stereo-PIV(Stereo Particle Image Velocimetry) was performed to investigate the structural characteristics of flow field in Rushton Turbine Mixer. Instantaneous 3D velocity fields are measured by two 2K${\times}$2K CCD cameras focused on an object plane with the angular displacement methods while the concentration fields are obtained through the measurement of the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. Finally, the spatial structures of turbulent flow around Rushton turbine were identified by the calculation of synchronized data of the velocity field and concentration field.

A Study on the Turbulent Characteristics of Rushton Turbine Mixer by Simultaneous Measurement of Velocity and Concentration Field with Stereo-PIV/PLIF Technique (Stereo-PIV/PLIF의 속도장과 농도장 동시측정 기법을 이용한 러쉬톤 교반기내 난류특성에 관한 연구)

  • Min, Young-Uk;Kim, Yun-Gi;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.694-699
    • /
    • 2003
  • Simultaneous measurement with PLIF(Planar Laser-Induced Fluorescence) and Stereo-PIV(Stereoscopic Particle Image Velocimetry) was performed to investigate the structural characteristics of flow field in Rushton Turbine Mixer. Instantaneous 3D velocity fields are measured by two 2K ${\times}$ 2K CCD cameras focused on an object plane with the angular displacement methods while the concentration fields are obtained through the measurement of the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. Finally, the spatial structures of turbulent mixing around Rushton turbine were identified by the calculation of cross-correlation fields between the velocity and concentration field.

  • PDF

A Study on the Mixing Characteristics in Complex Turbulent Flow by a Laser Induced Fluorescence Method (레이저 형광여기법(LIF)를 이용한 복잡 난류유동장의 혼합특성에 관한 연구)

  • Kim, Kyung-Chun;Jeong, Eun-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.542-547
    • /
    • 2001
  • A non-intrusive Planar Laser-Induced Fluorescence(PLIF) technique was applied to study the turbulent mixing process in a Rushton turbine reactor. Instantaneous and ensemble averaged concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by a thin Nd:Yag laser sheet illuminating the whole center plane of the stirred tank. The gray level images captured by a 14-bit cooled CCD camera can be transformed to the local concentration values using a calibration matrix. The dye injection point was selected at the tank wall with three quarter height (3/4H) from the tank bottom to observe the mixing characteristics in upper bulk flow region. There exist distinct two time scales: the rapid decay of mean concentration in each region after the dye infusion reflects the large scale mixing while the followed slow decay reveals the small scale mixing. The temporal change of concentration probability functions conjectures the two sequential processes in the batch type mixing. An inactive column of water existed above the impeller disk, in which the fluid rotates with the shaft but is isolated from the mean bulk flow.

  • PDF

A Study on the Mixing Characteristics in a Rushton Turbine Reactor by a Laser Induced Fluorescence Method (레이저 형광여기법(LIF)를 이용한 러쉬톤 터빈 교반기의 혼합특성에 관한 연구)

  • Jeong, Eun-Ho;Kim, Gyeong-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1145-1152
    • /
    • 2002
  • A non-intrusive Planar Laser-Induced Fluorescence(PLIF) technique was applied to study the turbulent mixing process in a Rushton turbine reactor. Instantaneous and ensemble averaged concentration fields was obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by a thin Nd:Yag laser sheet illuminating the whole center plane of the stirred tank. The gray level images captured by a 14-bit cooled CCD camera could be transformed to the local concentration values using a calibration matrix. The dye injection point was selected at the tank wall with three quarter. height (3/4H) from the tank bottom to observe the mixing characteristics in upper bulk flow region. There exist distinct two time scales: the rapid decay of mean concentration after the dye infusion reflects the large scale turbulent mixing while the fellowed slow decay reveals the small scale molecular mixing. The temporal change of concentration variance field conjectures the two sequential processes for the batch type mixing. An inactive column of water is existed above the impeller disk, in which the fluid rotates with the shaft but is isolated from the mean bulk flow.

CO Two-photon Laser Induced Fluorescence Measurements in High Temperature and Pressure Conditions (고온고압 조건에서 Two-Photon LIF를 이용한 CO 측정에 관한 연구)

  • Oh, Seung-Mook;Kim, Duk-Sang;Miles, Paul C.;Colban, Will F.
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Carbon monoxide (CO) is not only an important intermediate species in chemical reaction mechanisms of hydrocarbon fuel combustion, but also a crucial pollutant species emitted from automotive engines. To better understand the physical processes impacting CO emissions, the development of laser-based measurement techniques that can visualize in-cylinder CO distributions is desirable. Among these techniques, Laser-Induced Fluorescence (LIF) is a sensitive and species-selective detection technique capable of good spatial resolution. However, some technical matters such as deep UV excitation, severe pressure dependency of the LIF signal, and potential interference from other species have been major challenges for CO LIF application. This study is focused on investigating the feasibility of CO two-photon LIF in a direct-injection diesel engine operating at typical pressure and temperature conditions with commercial grade diesel fuel. Spectroscopic analysis shows that the CO fluorescence signal can be separated from $C_2$ Swan band or broadband fluorescence from PAHs when the signal is collected near 483 nm. The signal-to-noise ratio of CO LIF deteriorate rapidly as pressure is increased, following $P^{-1.49}$ which matches the theoretical signal pressure dependency.

  • PDF

Fluorescence Characteristic Spectra of Domestic Fuel Products through Laser Induced Fluorescence Detection

  • Wu, Ting-Nien;Chang, Shui-Ping;Tsai, Wen-Hsien;Lin, Cian-Yi
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.5
    • /
    • pp.18-25
    • /
    • 2014
  • Traditional investigation procedures of soil and groundwater contamination are followed by soil gas sampling, soil sampling, groundwater sampling, establishment of monitoring wells, and groundwater monitoring. It often takes several weeks to obtain the analysis reports, and sometimes, it needs supplemental sampling and analysis to delineate the polluted area. Laser induced fluorescence (LIF) system is designed for the detection of free-phase petroleum pollutants, and it is suitable for on-site real-time site investigation when coupling with a direct push testing tool. Petroleum products always contain polycyclic aromatic hydrocarbon (PAH) compounds possessing fluorescence characteristics that make them detectable through LIF detection. In this study, LIF spectroscopy of 5 major fuel products was conducted to establish the databank of LIF fluorescence characteristic spectra, including gasoline, diesel, jet fuel, marine fuel and low-sulfur fuel. Multivariate statistical tools were also applied to distinguish LIF fluorescence characteristic spectra among the mixtures of selected fuel products. This study successfully demonstrated the feasibility of identifying fuel species based on LIF characteristic fluorescence spectra, also LIF seemed to be uncovered its powerful ability of tracing underground petroleum leakages.

A Study on the Measurements of Beam Wave Propagation and Fluorescence Spectroscopy in Particles Media (입자매질에서 빔파동전파와 형광분광 측정에 관한 연구)

  • Kim, Ki-Jun;Lee, Jou-Youb;Sung, Wan-Mo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.167-175
    • /
    • 2014
  • The influences of fluorescence, scattering, and flocculation in turbid material were interpreted for the scattered fluorescence intensity and wavelength, it has been studied the molecular properties by the spectroscopy of laser induced fluorescence(LIF). The effects of optical properties in scattering media have been found by the optical parameters(${\mu}_s$, ${\mu}_a$, ${\mu}_t$). Flocculation is an important step in many solid-liquid separation processes and is widely used in Photodynamic therapy. The interactions of several colloid particles can come into play which have major effect on the flocculation and LIF process. We measured scattering and fluorescence spectra of the sample for in vitro as function of concentration from lase source to detector. The value of scattering coefficient ${\mu}_s$ is large by means of the increasing particles of scatterer. Therefore, Phorphyrin A is larger than Phorphyrin C in scattering intensity ${\mu}_s$, but Phorphyrin A is smaller than Phorphyrin C in penetration depth ${\delta}$.

Visualization of Combustion by Using Laser Diagnostic Techniques (레이저 진단기법을 이용한 연소 가시화 기술)

  • Chung S. H.;Won S. H.
    • Journal of the Korean Society of Visualization
    • /
    • v.2 no.1
    • /
    • pp.52-56
    • /
    • 2004
  • Several visualization techniques of laser diagnostics are presented for combustion phenomena, including Mie scattering for flow, Rayleigh and Raman scattering spectroscopy for major species, laser-induced fluorescence for minor species, and laser-induced incandescence for soot. These techniques have been applied to understand the various combustion phenomena more clearly, including buoyancy-dominant flow system, diffusion flam oscillation, laminar and turbulent lifted flames, flame propagation along a vortex ring, and soot zone characteristics. The usefulness of laser diagnostics on a better understanding of physical mechanism is demonstrated.

  • PDF

A Study on Characteristics of Temperature and Radicals in Laminar Non-premixed H2/N2 Flame Using LIPF and LRS (레이저 유도 선해리 형광법과 래일레이 산란법에 의한 층류 비예혼합 수소/질소 화염의 온도 및 라디칼 특성에 관한 연구)

  • Jin, Seong Ho;Park, Kyoung Suk;Kim, Gun Hong;Kim, Gyung Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.13 no.3
    • /
    • pp.169-180
    • /
    • 2002
  • Rayleigh scattering and laser induced predissociative fluorescence are used to obtain two-dimensional images of temperature and species concentration in a laminar non-premixed flame of a diluted hydrogen jet. Rayleigh scattering cross-sections are experimentally obtained at 248nm. Planar images of OH and $O_2$ with tunable KrF excimer laser which has a) $0.5cm^{-1}$ linewidth, b) 0.5nm tuning range, c) 150mJ pulse energy, and d) 20ns pulse width are obtained to determine spatial distributions of OH and $O_2$. The technique is based on planar laser induced predissociative fluorescence (PLIPF) in which collisional quenching is almost avoided because of the fast predissociation. Dispersed LIPF spectra of OH and $O_2$ are also measured in a flame in order to confirm the excitation of single vibronic state of OH and $O_2$. OH and $O_2$ are excited on the $P_2$(8) and $Q_1$(11) line of the $A^2{\Sigma}^{+}({\nu}^{'}=3)-X^{2}{\Pi}({\nu}^{''}=o)$ band and R(17) line of the Schumann-Runge band $B^{3}{\Sigma}_{u}{^-}(\nu^{'}=0)-X^{3}{\Sigma}_{g}{^-}({\nu}^{''}=6)$, respectively. Fluorescence spectra of OH and Hot $O_2$ are captured and two-dimensional images of the hydrogen flame field are successfully visualized.

Study on Argon Metastable Density in ICP by Using Laser Induced Fluoresce

  • Seo, Byeong-Hun;Yu, Sin-Jae;Kim, Jeong-Hyeong;Seong, Dae-Jin;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.219.2-219.2
    • /
    • 2014
  • Characteristics of Argon metastable density with electron density have been studied by using Laser induced fluorescence (LIF) in ICP. Two different evolutions of measured metastable densities with electron density depending on a measurement position are addressed. The experimental result is explained by using a zero dimensional global model and is due to electron kinetic properties in the positions that can be seen from electron energy probability functions measured by Langmuir probe. The underlying physics on metastable density with electron density and an experimental method of LIF are presented in detail.

  • PDF