• 제목/요약/키워드: Laser surface treatment

검색결과 319건 처리시간 0.033초

YBa$_2$Cu$_3$O$_{7-{\delta}}$/SrTiO$_3$/YBa$_2$Cu$_3$O$_{7-{\delta}}$ multilayer structures for ground planes for ramp-edge junction devices

  • Kim, C.H.;Kim, Y.H.;Jung, K.R.;Hahn, T.S.;Park, J.H.;Choi, S.S.
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.179-183
    • /
    • 2000
  • For a ground plane in high-temperature superconducting ramp-edge junction devices, YBa$_2$Cu$_3$O$_{7-{\delta}}$/SrTiO$_3$/YBa$_2$Cu$_3$O$_{7-{\delta}}$ multilayer structures were fabricated using pulsed laser deposition and ECR ion milling. Various process parameters were adjusted to enhance the device characteristics. By etching the STO layer to form a tapered edge of about 15$^{\circ}$ and in-situ RF plasma treatment of bottom YBCO surface prior to deposition of top YBCO, the top-to-bottom YBCO showed T$_c$ of 75${\sim}$80 K and I$_c$ of about 40 mA through holes. It was found that the deposition of bottom YBCO at a reduced laser repetition rate of 1Hz increased the T$_c$ of top YBCO to 79.9 K. The resistivity of 570 layer was about 10$^6$ ${\Omega}$cm at 60 K, which ensures good electrical isolation between successive YBCO layers.

  • PDF

고차구조 변화에 따른 저밀도폴리에틸렌 박막의 전기적 특성 (Electrical Properties of Low Density Polyethylene Film by Superstructure Change)

  • 신종열;신현택;이수원;홍진웅
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.101-109
    • /
    • 2002
  • The electrical properties of polyethylene are changed by the superstructure. Such crystalline polymer as polyethylene or polypropylene changes crystallinity and products spherulite or trans-crystal when it is cooled slowly. In this study, after thermal treatment of LDPE at 100[${circ}C$], in silicone oil for an hour, we made specimens in order of slow cooling, water cooling, quenching according to cooling speed. Also, to study the influence of electrical properties due to the superstructure change, we analyzed physical properties and performed dielectric breakdown experiments using DC and impulse voltage Moreover we measured space charges in bulk using Laser Induced Pressure Pulse(LIPP) method. Trap level of specimen is 0.064[eV] at the low temperature region 0.31[eV] at the high temperature region in DC dielectric strength, 0.03[eV] at the low temperature region 0.0925[eV] at the high temperature region in impulse dielectric strength. As its result shows that the quantity of charges induced from the electrode surface increases with applied voltage time, and the distribution of space charges in samples increases the quantity of charges in proportion to applied voltage.

다양한 구조를 가진 알긴산-피브로인 비드 제조 (Preparation of Alginate-fibroin Beads with Diverse Structures)

  • 이진실;이신영;허원
    • KSBB Journal
    • /
    • 제26권5호
    • /
    • pp.422-426
    • /
    • 2011
  • Alginate bead has been supplemented with various polymers to control permeability and to enhance mechanical strength. In this report, fibroin-reinforced alginate hydrogel was prepared, in which spatial localization of fibroin molecules was investigated. Confocal laser scanning microscopy revealed that fibroin molecules formed a fibrous network in the alginate-fibroin beads, which was expected to enhance mechanical strength as same as in many composite materials. Uniaxial compression test showed that fibroin-reinforced alginate beads had increased mechanical strength only after methanol treatment that caused ${\beta}$-sheet formation among fibroin molecules. Simultaneous curing and dialysis of alginate beads were carried out to remove excesscalcium but to retain fibroin in the dialysis chamber, which fabricated beads without internal fibrous fluorescent stains. Fibroin molecules were only found beneath the surface of the beads. The fibroin-diffused shell was further processed to form a thick wall after drying or was mobilizedto the centre of the bead by methanol treatment. Accordingly, the structure analyses provide processing methods of fibroin to form a wall or center clumps, which could be applied to design controlled delivery device.

Er:YAG 레이저를 이용한 치아삭제 효과 (EFFECTS OF ER:YAG LASER ABLATION ON THE DENTIN)

  • 최남기;양규호;박상원;김옥준
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.683-693
    • /
    • 2001
  • Er:YAG 레이저는 파장이 물의 주흡수 정점과 일치하는 $2.94{\mu}m$의 방출파장을 가지기 때문에, 물분사를 하면서 사용했을 때, 다른 레이저보다 열손상은 더 작으면서 치아경조직을 보다 효과적으로 삭제한다고 알려져 있다. Er:YAG 레이저의 상아질 삭제 효과를 평가하고자 발거된 소구치와 대구치를 대상으로 상아질 시편을 제작하고 $2.94{\mu}m$의 pulsed Er:YAG 레이저(SDL-300EN, 삼성전자, 한국)를 handpiece형의 전달계를 이용한 비접촉식 방법으로, 물에 담궈진 시간과 레이저 조사시간에 따른 삭제량과 형태를 조사, 분석하여 다음과 같은 결과를 얻었다. 1. 건전 상아질에 대한 조사 결과물에 담군 시간이 증가할수록 삭제율이 증가하였다. 2. 건전 상아질과 우식 상아질에 150mJ, 10Hz의 조건으로, 30초간 레이저를 조사했을 때, 우식상아질에 비해 건전 상아질에서 surface irregularity가 증가하고 상아세관이 열리는 경향이 있었으며 crack이 관찰되었다. 또한 우식 상아질에 비해 많은 탄조각(ash flecks), crack이 관찰되었고 상아세관의 불연속성 (inconsistency)이 관찰되었다. 3. 우식 상아질에서 30초로 조사한 경우에서는 dark zone이 와동에 국한되어 나타났으며 작은 fleck들이 관찰되었고, 1분간 조사한 경우에서는 30초의 경우보다도 와동이 더 넓었으며, crack이 상아세관 주행방향과 직각으로 형성된 것을 관찰 할 수 있었다. 2분간 조사한 경우는 와동이 가장 넓었으며 crack이 더 많이 형성된 것을 볼 수 있었다.

  • PDF

SLM 방식으로 출력된 STS 316L의 기계적 및 마찰·마모 특성에 미치는 UNSM처리 후 영향에 관한 연구 (A Study on the Effect of UNSM Treatment on the Mechanical and Tribological Properties of STS 316L Printed by Selective Laser Melting)

  • 노준석;산성충호;우마로프 라크마트전;편영식;아마노프 아웨즈한
    • Tribology and Lubricants
    • /
    • 제34권6호
    • /
    • pp.270-278
    • /
    • 2018
  • STS 316L prepared by additive manufacturing (AM) exhibits deterioration of mechanical properties and wear resistance due to the presence of defects such as black-of-fusion defects, internal porosity, residual stress, and anisotropy. In addition, high surface roughness (integrity) of AM products remains an issue. This study aimed to apply ultrasonic nanocrystal surface modification (UNSM) technology to STS 316L prepared by AM to increase the surface hardness, to reduce the surface roughness, and to improve the friction and wear behavior to the level achieved by bulk material manufactured using traditional processes. Herein, the as-received and polished specimens were treated by UNSM technology and their resulting properties were compared and discussed. The results showed that UNSM technology increased the surface hardness and reduced the surface roughness of the as-received and polished specimens. These results can be attributed to grain size refinement and pore elimination from the surface. Moreover, the friction of the as-received and polished specimens after UNSM technology was lower compared to those of the as-received and polished specimens, but no significant differences in wear resistance were found.

Effects of Low-level Light Therapy at 740 nm on Dry Eye Disease In Vivo

  • Goo, Hyeyoon;Kim, Hoon;Ahn, Jin-Chul;Cho, Kyong Jin
    • Medical Lasers
    • /
    • 제8권2호
    • /
    • pp.50-58
    • /
    • 2019
  • Background and Objectives Low-level light therapy (LLLT) is an application of low-power light for various purposes such as promoting tissue repair, reducing inflammation, causing analgesia, etc. A previous study suggested the effect of light emitting diode (LED) light with the wavelength of 740 nm for promoting wound healing of corneal epithelial cells. This current study aimed to confirm the effect of LLLT for managing inflammation of a dry eye disease (DED) mouse model. Materials and Methods A total of 50C57BL/6 female mice were randomly grouped into 5 groups to compare the effect of LLLT:1) Control group, 2) Only LLLT group, 3) Dry eye group, 4) LLLT in dry eye group, and 5) Early treatment group. DED was induced with 4 daily injections of scopolamine hydrobromide and desiccation stress for 17 days, and LLLT at 740 nm was conducted once every 3 days. To analyze the effect of LLLT on the DED mouse model, tear volume, corneal surface irregularities, and fluorescence in stained cores were measured, and the level of inflammation was assessed with immunohistochemistry. Results The DED mouse model showed significant deterioration in the overall eye condition. After LLLT, the amount of tear volume was increased, and corneal surface irregularities were restored. Also, the number of neutrophils and the level of inflammatory cytokines significantly decreased as well. Conclusion This study showed that LLLT at 740 nm was effective in controlling the corneal conditions and the degree of inflammation in DED. Such findings may suggest therapeutic effects of LLLT at 740 nm on DED.

Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향 (The influence of Collar design on peri-implant marginal bone tissue)

  • 김지환;정문규;문홍석;한동후
    • 대한치과보철학회지
    • /
    • 제46권1호
    • /
    • pp.53-64
    • /
    • 2008
  • 임플랜트 주위 변연골의 흡수는 임플랜트의 기능적 및 심미적 성공에 큰 장애가 되는 요인이다. Adell은 임플랜트에 지대주 연결 후 첫 1년간 평균적으로 1.5mm의 변연골 소실을 보이고, 이 후에는 매년 0.1mm이하의 변연골 흡수가 있었다고 하였다(Adell et al.,1981). 이러한 변연골 흡수를 막기위한 많은 노력들이 행해져 왔다. 특히 임플랜트 collar의 특징에 따라서 변연골의 흡수가 달라질 수 있다. 본 연구의 목적은 임플랜트 collar에서의 laser microtexturing(microgroove)이 변연골 흡수에 미치는 영향에 대해 알아보고자 하는 것이다. 4종류의 임플랜트 총 101개를 식립한 환자 53명에서 임플랜트 식립시부터 보철물 장착한 후 평균 6개월 후 정기 검사 시까지의 임플랜트 주위 변연골의 흡수를 측정하여 비교하였다. 생물학적 폭경을 충분히 확보한 임플랜트(ITI standard)와 생물학적 폭경이 부족한 임플랜트 (ITI esthetic plus, Silhouette IC Laser-$Lok^{TM}$, Silhouette IC)에서 변연골 흡수의 차이를 비교하였고, 임플랜트 주위 변연골의 흡수에 대한 laser를 이용한 미세나사산의(Silhouette IC Laser-$Lok^{TM}$) 영향을 알아보았다. 다음의 결과를 얻었다. 1. ITI standard와 Silhouette IC Laser-$Lok^{TM}$ 이 ITI esthetic plus 와 Silhouette IC 보다 임플랜트 주위 변연골의 흡수가 적었고 (p<0.05), ITI standard 와 Silhouette IC Laser-$Lok^{TM}$ 사이에는 변연골의 흡수가 유의차가 없었고(P>0.05), ITI esthetic plus와 Silhouette IC 사이에도 변연골의 흡수가 유의차가 없었다(P>0.05). 2. 사용된 임플랜트 전체에 대한 상하악의 비교에서는 상하악 사이에서 임플랜트 주위 변연골의 흡수는 통계학적으로 유의한 차이가 없었다(p>0.05). 3. 흡수각도에 대한 비교에서도 4종류 임플랜트 그룹 간에 통계학적으로 유의한 차이는 없었다(P>0.05). 본 연구에서 제한이 있긴 하지만, 임플랜트 디자인에서 생물학적 폭경이 부족한 경우(ITI esthetic plus, Silhouette IC)에는 생물학적 폭 경 보상을 위한 임플랜트 주위 변연골의 흡수가 있었음을 보여주고 있으나, laser를 이용한 microgroove 가 부여된 임플랜트에서는 collar의 거칠기와 laser microtexturing 등의 특징에 의해 임플랜트 주위 변연골의 흡수가 적게 일어난 것이 관찰되었다. 심미적인 요구도가 높은 전치부에서 충분한 생물학적 폭경이 확보된 임플랜트를 식립할 경우 변연골의 흡수에 따른 치은퇴축에 의해 metal collar의 노출이 우려되기에 충분한 생물학적 폭경이 부여되지 않은 임플랜트를 선정하게 되는데 이때 collar에서의 laser microtexturing은 변연골의 유지에 도움이 되었다. 이것은 조직의 단단한 부착으로 인한 안정화로 추정해 볼 수 있는데, 이에 대해서는 더 장기간의 연구와 더 많은 수의 임플랜트를 대상으로 한 연구와 조직학적인 연구도 필요할 것으로 사료된다.

표면유도환자셋업(Surface-Guided Patient Setup, SGPS)을 활용한 Markerless환자의 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)시 유용성 평가 (Evaluation of the usefulness of IGRT(Image Guided Radiation Therapy) for markerless patients using SGPS(Surface-Guided Patient Setup))

  • 이경재;이응만;이정수;김다연;고현준;최신철
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.109-116
    • /
    • 2021
  • 목 적: 본 연구는 표면유도환자셋업(Surface-Guided Patient Setup, SGPS)을 활용한 Markerless환자(피부에 표시를 시행하지 않은 환자)와 레이저기반환자셋업(Laser-Based Patient Setup, LBPS)을 활용한 Marker환자(피부에 표시를 시행한 환자)를 영상유도방사선치료(Image Guided Radiotherapy, IGRT)로 시행했을 때 환자 위치 정확도를 비교하여 SGPS의 유용성을 평가하는데 목적이 있다. 대상 및 방법: 3개의 카메라를 이용한 광학 표면 스캐닝시스템을 사용하여 SGPS로 초기 셋업한 Markerless 환자와 환자 피부에 그려진 Marker와 레이저를 정렬하는 LBPS로 초기 셋업한 Marker환자의 IGRT시 위치 오차를 비교하였다. SGPS,LBPS 모두 각각 전립선암 환자 20명, 뇌정위적방사선수술(Stereotactic Radiation Surgery, SRS) 환자 10명을 대상으로 시행하였고 SGPS의 경우는 추가로 유방암 환자 60명을 대상으로 시행하였다. 모두 CBCT 또는 OBI를 사용하여 IGRT를 시행하였다. 자동위치교정시스템(Auto-Matching System)을 이용하여 6방향(6 Degree Of Freedom, 6 DoF)의 위치 오차를 획득하였고 치료계획시스템에서 Offline-Review를 이용하여 비교, 분석하였다. 결 과 : 전립선암환자의 SGPS와 LBPS의 RMS(Root Mean Square) 차이는 Vrt -0.02cm, Log -0.02cm, Lat -0.01cm, Pit -0.01°, Rol -0.01°, Rtn -0.01°이였고 SRS 환자는 Vrt 0.02cm, Log -0.05cm, Lat 0.00cm, Pit -0.30°, Rol -0.15°, Rtn -0.33°으로 두 부위 모두 큰 차이가 없었다. 유방암환자의 IGRT기준 RMS는 Vrt 0.26, Log 0.21, Lat 0.15, Pit 0.81, Rol 0.49, Rtn 0.59으로 나타났다. 결 론 : 본 연구의 결과 LBPS 대비 SGPS의 위치 오차 값은 전립선암 환자와 SRS 환자의 경우 큰 차이를 보이지 않았다. 추가로 실시한 SGPS의 유방암 환자의 경우에도 IGRT기준으로 위치 오차 값이 크지 않았다. 따라서 환자 피부 표시를 필요로 하지 않는 큰 장점을 가진 SGPS로 LBPS를 대체하기에 유용할 것으로 사료된다.

마이크로-필터 상에 금속 나노입자 코팅에 의한 나노구조 기공층 멤브레인 필터 개발 (Development of Membrane Filter with Nanostructured Porous Layer by Coating Metal Nanoparticles onto a Micor-Filter)

  • 이동근;박석주;박영옥;류정인
    • Korean Chemical Engineering Research
    • /
    • 제45권6호
    • /
    • pp.591-595
    • /
    • 2007
  • 기존 마이크론 금속섬유 필터를 지지체로 그 표면 위에 나노입자 증착 후, 열처리를 하여 나노구조 기공층이 표면에 부착 형성된 멤브레인 필터를 제작하였다. 가지상 구조의 나노입자 응집체를 마이크론 금속섬유 필터상에 부착함으로써 기존 금속 멤브레인 필터에 비하여 여과성능이 향상된 나노구조 기공층 멤브레인 필터를 개발하였다. 증착한 나노구조 기공층을 지지체 필터 표면상에 부착시키기 위한 열처리 온도가 증가함에 따라 나노입자 응집체의 수축 현상으로 인하여 나노구조 기공층 멤브레인 필터의 차압은 감소하였지만, 여과효율의 감소는 미미하였다.

N2 plasma treatment of pigments with minute particle sizes to improve their dispersion properties in deionized water

  • Zhang, Jingjing;Park, Yeong Min;Tan, Xing Yan;Bae, Mun Ki;Kim, Dong Jun;Jang, Tae Hwan;Kim, Min Su;Lee, Seung Whan;Kim, Tae Gyu
    • Journal of Ceramic Processing Research
    • /
    • 제20권6호
    • /
    • pp.589-596
    • /
    • 2019
  • Pigments with minute particle sizes, such as carbon black (CB) and pigment red 48:2 (P.R.48:2), are the most important types of pigment and have been widely used in many industrial applications. However, minute particles have large surface areas, high oil absorption and low surface energy. They therefore tend to be repellent to the vehicle and lose stability, resulting in significant increases in viscosity or reaggregation in the vehicle. Therefore, finding the best way to improve the dispersion properties of minute particle size pigments presents a major technical challenge. In this study, minute particle types of CB and P.R.48:2 were treated with nitrogen gas plasma generated via radio frequency-plasma enhanced chemical vapor deposition (RF-PECVD) to increase the dispersion properties of minute particles in deionized (DI) water. The morphologies and particle sizes of untreated and plasma treated particles were evaluated using scanning electron microscopy (SEM) and atomic force microscopy (AFM). The average distributions of particle size were measured using a laser particle sizer. Fourier transform infrared spectroscopy was carried out on the samples to identify changes in molecular interactions during plasma processing. The results of our analysis indicate that N2 plasma treatment is an effective method for improving the dispersibility of minute particles of pigment in DI water.