• 제목/요약/키워드: Laser scanning system

검색결과 393건 처리시간 0.03초

시스템 초기화(Calibration)에 따른 항공레이저측량의 정확도 평가 (The Evaluation of Accuracy for Airborne Laser Surveying via LiDAR System Calibration)

  • 이대희;위광재;김승용;김갑진;이재원
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 춘계학술발표회논문집
    • /
    • pp.15-26
    • /
    • 2004
  • The calibration for systematic error in LiDAR is crucial for the accuracy of airborne laser scanning. The main error is the misalignment of platforms between INS(Inertial Navigation System) and Laser scanner For planimetrical calibration of LiDAR, the building is good feature which has great changes in height and continuous flat area in the top. The planimetry error(pitch, roll) is corrected by adjustment of height which is calculated from comparing ground control points(GCP) of building to laser scanning data. We can know scale correction of laser range by the comparison of LiDAR data and GCP is arranged at the end of scan angle where maximize the height error. The area for scale calibration have to be large flat and have almost same elevation. At 1000m for average flying height, The Accuracy of laser scanning data using LiDAR is within 110cm in height and ${\pm}$50cm in planmetry so we can use laser scanning data for generating 3D terrain surface, expecically digital surface model(DSM) which is difficult to measure by aerial photogrammetry in forest, coast, urban area of high buildings

  • PDF

STL 메쉬를 이용한 자유곡면의 레이저 측정경로 생성 연구 (STL mesh based laser scan planning system for complex freeform surfaces)

  • 손석배;김승만;이관행
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.595-598
    • /
    • 2002
  • Laser scanners are getting used more and more in reverse engineering and inspection. For CNC-driven laser scanners, it is important to automate the scanning operations to improve the accuracy of capture point data and to reduce scanning time in industry. However, there are few research works on laser scan planning system. In addition, it is difficult to directly analyze multi-patched freeform models. In this paper, we propose an STL (Stereolithography) mesh based laser scan planning system for complex freeform surfaces. The scan planning system consists of three steps and it is assumed that the CAD model of the part exists. Firstly, the surface model is approximated into STL meshes. From the mesh model, normal vector of each node point is estimated. Second, scan directions and regions are determined through the region growing method. Also, scan paths are generated by calculating the minimum-bounding rectangle of points that can be scanned in each scan direction. Finally, the generated scan directions and paths are validated by checking optical constraints and the collision between the laser probe and the part to be scanned.

  • PDF

레이저 펄스 부호화를 이용한 원거리 고해상도 3D 스캐닝 라이다 (Long Distance and High Resolution Three-Dimensional Scanning LIDAR with Coded Laser Pulse Waves)

  • 김건정;박용완
    • 한국광학회지
    • /
    • 제27권4호
    • /
    • pp.133-142
    • /
    • 2016
  • 본 논문에서는 DS-OCDMA(direct sequence optical code division multiple access)와 스캐닝 방식의 MEMS (microelectromechanical system) 거울을 이용하여 픽셀별로 스캐닝하는 라이다 시스템(light detection and ranging, LIDAR)의 설계와 시뮬레이션 결과를 기술한다. 제안하는 라이다는 $848{\times}480$ 해상도의 거리 영상을 1초에 60번 측정한다. 영상을 구성하는 각각의 픽셀마다 픽셀 정보와 체크섬을 DS-OCDMA로 부호화한 레이저 펄스로 방출하므로, 반사파를 검출하기 위하여 대기할 필요없이 연속으로 거리 측정이 가능하다. MEMS 거울은 부호화된 레이저 펄스를 반사하여 측정을 원하는 방향으로 보내기 위한 용도로 사용한다. 하나의 거리 영상을 구성하는 픽셀 정보의 처리가 모두 완료되면, 픽셀 개개의 반사파 비행시간을 이용하여 포인트 클라우드를 생성한다.

포인트 레이저 센서를 이용한 구면좌표계식 3차원 형상측정시스템 개발 (Development of 3D Measuring System using Spherical Coordinate Mechanism by Point Laser Sensor)

  • 맹희영;성봉현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.201-206
    • /
    • 2004
  • Laser scanner are getting used for inspection and reverse engineering in industry such as motors, electronic products, dies and molds. However, due to the lack of efficient scanning technique, the tasks become limited to the low accuracy purpose. The main reasons for this limitation for usefulness are caused from the optical drawback, such as irregular reflection, scanning direction normal to measuring surface, the influence of surface integrity, and other optical disturbances. To overcome these drawback of laser scanner, this study propose the mechanism to reduce the optical trouble by using the 2 kinds of rotational movement axis and by composing the spherical coordinate to scanning the surface keeping normal direction consistently. So, it could be designed and interfaced the measuring device to realize that mechanism, and then it could acquisite the accurate 3D form cloud data. Also, these data are compared with the standard master ball and the data acquisited from the touch point sensor, to evaluate the accuracy and stability of measurement and to demonstrate the implementation of an dental tooth purpose system

  • PDF

터널의 비접촉 이동식 상태점검 장비: 리뷰 (Non-contact mobile inspection system for tunnels: a review)

  • 이철희;김동규
    • 한국터널지하공간학회 논문집
    • /
    • 제25권3호
    • /
    • pp.245-259
    • /
    • 2023
  • 본 논문의 목적은 국내외 터널 스캐닝 시스템들을 분석하여 비접촉 이동식 상태점검 장비 개발에 대한 시사점을 도출하기 위한 것이다. 국내외 터널 스캐닝 시스템은 레이저 스캔과 이미지 스캔의 두 가지 기술로 개발되고 있다. 레이저 스캐닝 장비는 포인트 클라우드로부터 터널 라이닝의 기하하적 특성을 재현하는데 장점이 있다. 이미지 스캐닝 장비는 컴퓨터 비전을 활용하여 터널 라이닝 표면의 미세한 균열, 누수 등 손상 검출이 용이하다. 터널 라이닝의 손상 검출을 위해서는 이미지 스캐닝 장비가 더 적합할 것으로 분석되었다. 향후 개발 예정인 카메라 기반의 터널 스캐닝 시스템은 조명, 저장장치, 전원 공급 장치 및 차량 주행 속도 동기화 제어 장치로 구성되어야 할 것이다.

레이저 거리계의 이론적 최소 분해능에 관한 연구 (A study on the theoretical minimum resolution of the laser range finder)

  • 차영엽;권대갑
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.644-647
    • /
    • 1996
  • In this study the theoretical minimum resolution analysis of an active vision system using laser range finder is performed for surrounding recognition and 3D data acquisition in unknown environment. The laser range finder consists of a slitted laser beam generator, a scanning mechanism, CCD camera, and a signal processing unit. A laser beam from laser source is slitted by a set of cylindrical lenses and the slitted laser beam is emitted up and down and rotates by the scanning mechanism. The image of laser beam reflected on the surface of an object is engraved on the CCD array. In the result, the resolution of range data in laser range finder is depend on distance between lens center of CCD camera and light emitter, view and beam angles, and parameters of CCD camera.

  • PDF

레이저 진동 측정기를 이용한 초음파 이송 시스템의 동작특성에 관한 연구 (A Study on the Motion Characteristics of the Ultrasonic Transport System using Laser Scanning Vibrometer)

  • 정상화;신병수;이경형
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.155-158
    • /
    • 2003
  • In the semiconductor and the optical industry a new transport system which can replace the conventional sliding system is required. These systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system can solve these problem. In this paper, the vibration behavior of flexural beam in the ultrasonic transport system is verified using Laser Scanning Vibrometer. The experiments for verifying vibration are performed in three conditions such as in the maximum transport speed, in the zero speed, and in the change of transport direction.

  • PDF

Evaluation of Geometric Error Sources for Terrestrial Laser Scanner

  • Lee, Ji Sang;Hong, Seung Hwan;Park, Il Suk;Cho, Hyoung Sig;Sohn, Hong Gyoo
    • 대한공간정보학회지
    • /
    • 제24권2호
    • /
    • pp.79-87
    • /
    • 2016
  • As 3D geospatial information is demanded, terrestrial laser scanners which can obtain 3D model of objects have been applied in various fields such as Building Information Modeling (BIM), structural analysis, and disaster management. To acquire precise data, performance evaluation of a terrestrial laser scanner must be conducted. While existing 3D surveying equipment like a total station has a standard method for performance evaluation, a terrestrial laser scanner evaluation technique for users is not established. This paper categorizes and analyzes error sources which generally occur in terrestrial laser scanning. In addition to the prior researches about categorizing error sources of terrestrial Laser scanning, this paper evaluates the error sources by the actual field tests for the smooth in-situ applications.The error factors in terrestrial laser scanning are categorized into interior error caused by mechanical errors in a terrestrial laser scanner and exterior errors affected by scanning geometry and target property. Each error sources were evaluated by simulation and actual experiments. The 3D coordinates of observed target can be distortedby the biases in distance and rotation measurement in scanning system. In particular, the exterior factors caused significant geometric errors in observed point cloud. The noise points can be generated by steep incidence angle, mixed-pixel and crosstalk. In using terrestrial laser scanner, elaborate scanning plan and proper post processing are required to obtain valid and accurate 3D spatial information.

SFFS 장비 개발을 위한 레이저 주사 시스템에 관한 연구

  • 최경현;최재원;김대현;도양회;이석희;김성종;김동수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 춘계학술대회 논문요약집
    • /
    • pp.308-308
    • /
    • 2004
  • 쾌속조형기술은 설계형상의 확인, 시작품의 제작, 금속 및 세라믹 부품에의 응용, 동시공학, 의료, 마이크로 머신 둥 제조업 전반에 걸쳐서 많은 응용이 이루어지고 있다 여러 가지의 기술들이 개발되고 이를 응용한 장비들이 생산되어 보급됨으로써 이러한 적용분야들은 점차 확대되고 있다. 본 연구에서는 분말을 소결, 적층하여 원하는 형상을 만들어내는 SLS(Selective Laser Sintering) 장비를 개발하는데 있어서 레이저 경로의 제어를 통한 분말을 소결시키는 부분인 레이저 주사 시스템(laser scanning system)을 개발하고자 한다.(중략)

  • PDF

한대의 LSV 를 이용한 3 차원 진동측정방법 (Three-dimensional vibration measurement algorithm using one laser scanning vibrometer)

  • 김동규;송하준;박기환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.935-939
    • /
    • 2012
  • 3D vibration measurement is achieved using one laser scanning vibrometer(LSV) and Laser scanner(LS) by moving the LSV to three arbitrarily locations from the principle that vibration analysis based on the frequency domain is independent of the vibration signal based on time domain. The proposed system has the same effect as using three sets of LSVs. It has an advantage of reducing equipment costs. Analytical approach of obtaining in-plane and out-of-plane vibration of surface is introduced using geometrical relations between three LSV coordinates and vibration measured at three different locations.

  • PDF