• Title/Summary/Keyword: Laser parameters

Search Result 980, Processing Time 0.027 seconds

Study on Laser Cladding of Heat Resisting Steel Using EuTroLoy 16006 Powder(II) - Characteristics of Alloying Elements Distribution of Multi Pass Clad Layer - (EuTroLoy 16006 분말을 이용한 내열강의 레이저 클래딩에 관한 연구(II) - 멀티패스 클래드 층의 합금 성분 분포 특성 -)

  • Kim, Jong Do;Lee, Eun Jin;Kim, Cheol Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.4
    • /
    • pp.307-312
    • /
    • 2017
  • Laser cladding has some advantages compared to conventional cladding technologies such as arc welding and thermal spraying. Laser cladding produces a metallurgically well-bonded clad layer with a lower dilution ratio and few defects. Based on the characteristics of a 1-pass clad layer with many parameters, which were investigated in a previous report, it was found that it was essential to overlap a 1-pass clad layer when cladding a large area. In this study, the shape differences of multi-pass clad layers with various overlapping ratios were compared. Then, the alloying element distribution of cladding with a certain overlapping ratio was investigated using EDS and EPMA. As the overlapping ratio increased, the length of the clad decreased and its height increased. In addition, the height of the multi-pass cladding was higher than that of the 1-pass cladding under the same condition. The Fe content of the highly diluted first clad was found to be approximately 20 % in an element analysis. However in the area outside of the first clad, the Fe content was decreased to 10 % as a result of minimum dilution, and a uniform distribution of elements was found.

Reliability and utility of a Dry Test Bench for testing the acoustic output from a ballistic shock wave therapeutic device (탄도형 충격파 치료기의 음향 출력 시험을 위한 Dry Test Bench의 신뢰성 및 유용성)

  • Jeon, Sung Joung;Lee, Min Young;Kwon, Oh Bin;Kim, Jong Min;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.589-600
    • /
    • 2022
  • In order to verify the reliability of Dry Test Bench (DTB) used for testing the output energy from ballistic extracorporeal shock wave therapeutic devices, the measurements with DTB were compared with the acoustic energy measured with a Laser Doppler Vibrometer (LDV) for a commercial ballistic ESWT device. It was shown that the mechanical energy detected with DTB had variability maintained within 5 % at the same output power setting and also had a linear correlation (adj. R2 = 0.991) with the acoustic energy measured with the LDV for the entire output power settings. Using the correlation between the two methods and the correlation on the acoustic energy measured in between air and water with the LDV, the DTB measurement can be used to estimate the energy flux density in water with an average error of 7.85 % for the entire output power settings of the ballistic shock wave generator considered in the experiment. DTB provides information limited to the output mechanical energy and therefore it is not suitable for testing the various acoustic output parameters required in IEC61846 and IEC63045. However, DTB that is simple in measurement principles and easy to use is expected for manufacturers and clinical users to monitor the performance of ballistic Extracorporeal Shock Wave Therapy (ESWT) devices.

Experimental Study on Geometry of a Microlayer During Single-Bubble Nucleate Boiling (단일기포 핵비등 시 미세액막층 구조에 대한 실험적 연구)

  • Jeong, Seunghyuck;Jung, Satbyoul;Kim, Hyungdae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.6
    • /
    • pp.519-526
    • /
    • 2015
  • To measure the physical parameters of the simple microlayer model for the prediction of the heat flux and heat transfer rate due to the evaporation of the microlayer during nucleate boiling, the microlayer geometry was experimentally examined. The parameters, including initial thickness, moving velocity and microlayer radius, were measured by total reflection and interferometry techniques using a laser. Single-bubble nucleate boiling experiments were conducted using saturated water on a horizontal surface under atmospheric pressure. The geometric characteristics of the microlayer underneath the bubbles periodically nucleating at a nucleation site at an average heat flux of $200kW/m^2$ were analyzed. The experimental results in the present study show that the maximum initial thickness of the microlayer and the horizontal moving velocity are $5.4{\mu}m$ and 0.12 m/s, respectively.

Curved Feature Modeling and Accuracy Analysis Using Point Cloud Data (점군집 데이터를 이용한 곡면객체 모델링 및 정확도 분석)

  • Lee, Dae Geon;Yoo, Eun Jin;Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.3
    • /
    • pp.243-251
    • /
    • 2016
  • LiDAR data processing steps include noise removal, filtering, classification, segmentation, shape recognition, modeling, and quality assessment. This paper focuses on modeling and accuracy evaluation of 3D objects with curved surfaces. The appropriate modeling functions were determined by analyzing surface patch shape. Existing methods for modeling curved surface features require linearization, initial approximation, and iteration of the non-linear functions. However, proposed method could directly estimate the unknown parameters of the modeling functions. The results demonstrate feasibility of the proposed method. The proposed method was applied to the simulated and real building data of hemi-spherical and semi-cylindrical surfaces. The parameters and accuracy of the modeling functions were estimated. It is expected that the proposed method would contribute to automatic modeling of various objects.

Pharmacoeconomic Analysis of Tafluprost compared with Latanoprost on the Treatment of Primary open Angle Glaucoma or Ocular Hypertension in Korea (녹내장치료에 있어서 Tafluprost와 Latanoprost의 경제성평가)

  • Kang, Suk-Hyun;Song, Hyun-Jin;Heo, Ji-Heong;Lee, Eui-Kyung
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.278-287
    • /
    • 2010
  • The main objective of this study is to evaluate the cost-effectiveness of tafluprost compared with latanoprost in primry open Angle Glaucoma (POAG) or ocular hypertension OH patients in Korea. A decision analytic model was developed from a societal perspective to estimate clinical outcome, drug cost and glaucoma related cost. The model assumes branch like following: successful treatment, switching to other drug, adding other drug, laser or surgery. Treatment success rate is defined as the percentage of patients with elevated IOP achieving <20% reduction, and discontinuation rate is the percentage of patients who were withdrawn due to severe adverse events. A model that is comprised of 1 month cycle length has 1 year. Treatment success rate and discontinuation rate were obtained from published literatures searched in database. Resource utilizations and costs were calculated with national health insurance data and clinical expert opinions. Sensitivity analyses were performed on crucial parameters. Tafluprost is less costly than latanoprost, $609.0 vs $651.2 expected cost. Thus tafluprost was shown to be dominant compared with latanoprost. The results of sensitivity analysis revealed stable across most of the included parameters. According to this study, tafluprost shows more clinical outcome for 1 year than latanoprost. In addition, first-line treatment of tafluprost is a more cost-minimizing strategy associated with POAG or OH compared with latanoprost.

Transport parameters in a-Se:As films for digital X-ray conversion material (디지털 X-선 변환물질 a-Se:As의 수송변수)

  • Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.8 no.1
    • /
    • pp.51-55
    • /
    • 2006
  • The effects of Asaddition in amorphous selenium(a-Se) films for digital X-ray conversion material have been studied using the moving photocarrier grating(MPG) technique. This method utilizes the moving interference pattern generated by the superposition of the two frequency shifted laser beams for the illumination of the sample. This moving intensity grating induces a short circuit current, j$_{sc}$ in a-Se:As film. The transport parameters of the sample are extracted from the grating-velocity dependent short circuit current induced in the sample along the modulation direction. The electron and hole mobility, and recombination lifetime of a-Se films with arsenic(As) additions have been obtained. We have found an Increase in hole drift mobility and recombination lifetime, especially when 0.3% As is added into a-Se film, whereas electron mobility decreases with As addition due to the defect density. The transport properties for As doped a-Se films obtained by using MPG technique have been compared with X-ray sensitivity for a-Se:As device. The fabricated a-Se(0.3% As) device film exhibited the highest X-ray sensitivity out of 5 samples.

  • PDF

Performance evaluation method of homogeneous stereo camera system for full-field structural deformation estimation

  • Yun, Jong-Min;Kim, Ho-Young;Han, Jae-Hung;Kim, Hong-Il;Kwon, Hyuk-Jun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.3
    • /
    • pp.380-393
    • /
    • 2015
  • This study presents how we can evaluate stereo camera systems for the structural deformation monitoring. A stereo camera system, consisting of a set of stereo cameras and reflective markers attached on the structure, is introduced for the measurement and the stereo pattern recognition (SPR) method is utilized for the full-field structural deformation estimation. Performance of this measurement system depends on many parameters including types and specifications of the cameras, locations and orientations of them, and sizes and positions of markers; it is difficult to experimentally identify the effects of each parameter on the measurement performance. In this study, a simulation framework for evaluating performance of the stereo camera systems with various parameters has been developed. The maximum normalized root-mean-square (RMS) error is defined as a representative index of stereo camera system performance. A plate structure is chosen for an introductory example. Its several modal harmonic vibrations are generated and estimated in the simulation framework. Two cases of simulations are conducted to see the effects of camera locations and the resolutions of the cameras. An experimental validation is carried out for a few selected cases from the simulations. Using the simultaneous laser displacement sensor (LDS) measurements as the reference, the measurement errors are obtained and compared with the simulations.

Detecting and Restoring Occlusion Area for Generating Digital Orthoimage (수치정사투영영상 제작을 위한 폐색영역의 탐지와 복원)

  • 권오형;김형태;김용일
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 2000
  • With the emergence of laser mapping systems, higher resolution DTM of urban area can be acquired and can be used to generate precise orthoimage. But, when the conventional orthoimage generation methods are applied to the area containing features with height difference such as cliffs, bridges, banks. elevated highways and buildings, they cause problems such as occlusion and double mapping. Therefore, this study proposes a new algorithm by modifying and refining conventional orthoimage generation methods. With this algorithm, areas which have occlusion are detected from the base image using camera orientation parameters and DTM. Also, detected areas are restored using alternative images which does not have occlusion in that area. This study can be distinguished from the other studies in the aspects that the proposed algorithm in this paper doesn't need information on building and that uses DTM data and orientation parameters.

  • PDF

Geometric Modeling and Data Simulation of an Airborne LIDAR System (항공라이다시스템의 기하모델링 및 데이터 시뮬레이션)

  • Kim, Seong-Joon;Min, Seong-Hong;Lee, Im-Pyeong;Choi, Kyung-Ah
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.3
    • /
    • pp.311-320
    • /
    • 2008
  • A LIDAR can rapidly generate 3D points by densely sampling the surfaces of targets using laser pulses, which has been efficiently utilized to reconstruct 3D models of the targets automatically. Due to this advantage, LIDARs are increasingly applied to the fields of Defense and Security, for examples, being employed to intelligently guided missiles and manned/unmanned reconnaissance planes. For the prior verification of the LIDAR applicability, this study aims at generating simulated LIDAR data. Here, we derived the sensor equation by modelling the geometric relationships between the LIDAR sub-modules, such as GPS, IMU, LS and the systematic errors associated with them. Based on this equation, we developed a program to generate simulated data with the system parameters, the systematic errors, the flight trajectories and attitudes, and the reference terrain model given. This program had been applied to generating simulated LIDAR data for urban areas. By analyzing these simulated data, we verified the accuracy and usefulness of the simulation. The simulator developed in this study will provide economically various test data required for the development of application algorithms and contribute to the optimal establishment of the flight and system parameters.

Preparation and Characterization of Suvarna Bhasma Parada Marit - Characterization of Suvarna Bhasma Parada Marit -

  • Thakur, Kapil;Gudi, Ramacharya;Vahalia, Mahesh;Shitut, Shekhar;Nadkarni, Shailesh
    • Journal of Pharmacopuncture
    • /
    • v.20 no.1
    • /
    • pp.36-44
    • /
    • 2017
  • Objectives: The goal of this study was to characterize Suvarna Bhasma Parada Marit by using the Ayurvedic test parameters, physico-chemical tests, and various instrumentation techniques. Methods: Suvarna Bhasma, an Ayurvedic formulation manufactured as per Bharat Bhaishajya Ratnakar 5/8357 (BBR), has been studied using various instrumentation techniques: X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDAX), laser particle size distribution (PSD) analysis, fourier transform infrared spectroscopy (FT-IR), and atomic absorption spectroscopy (AAS), and physico-chemical parameters, such as the loss on drying (LOD), loss on ignition (LOI), and acid insoluble Ash (AIA) were determined. In addition, Ayurvedic tests, such as Rekhapurnatva (enterable in the furrows of the fingers), Varitaratwa (floatable over water), Nirdhoomta (smokeless), Dantagre Kach-Kach (gritty particle feeling between the teeth), were performed. Results: The XRD study showed Suvarna Bhasma to be crystalline in nature and to contain more than 98% gold. The mean size of the gold crystallites was less than 10 microns, and the morphology was globular and irregular. Suvarna Bhasma contains gold as its single and major element, with EDAX and FT-IR spectra showing that it is more than 98% pure gold. The moisture content (LOD) is less than 0.5%, the LOI is less than 2%, and the AIA is not less than 95%. The Ayurvedic tests, as specified above, helped to confirm the quality of Suvarna bhasma prepared as per the text reference (BBR). Conclusion: This chemical characterization of Suvarna Bhasma performed in this study by using modern instrumentation techniques will be helpful in understanding its pharmacological actions and will help in establishing quality protocols and specifications to substantiate the safety, efficacy & quality of Suvarna Bhasma.