• Title/Summary/Keyword: Laser irradiation

Search Result 624, Processing Time 0.032 seconds

The Study on the Application of He-Ne Laser with Low Energy ILIB to the Superficial Venules (저용량(低容量) He-Ne 레이저침의 혈락적용(血絡適用) 연구(硏究))

  • Kim Sung-Chul;Cho Eun-Hee;Na Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.20 no.3
    • /
    • pp.35-47
    • /
    • 2003
  • Objective : The purpose of this study was to investigate the significance of the Oriental medical treatment using He-Ne laser with low energy intravascular Laser Irradiation of Blood(ILIB) through the superficial venules. Methods : The investigation of details connected with the superficial venules in the literature is performed. The investigation of details connected with the pricking blood techniques through the superficial venules in the literature is performed. The classification of the pricking blood techniques through the superficial venules by the blood-letting puncture methods in the literature is performed. The arrangement of domestic clinical treatises on the effectiveness of medical treatment using He-Ne laser with low energy ILIB through the superficial venules is performed. The consideration on the methodology for the improvement of the clinical effectiveness of He-Ne laser with low energy ILIB through superficial venules is performed. Results and Conclusions : The superficial venules are small arteries, veins and capillaries in the superficial region of the human body. In the pricking blood techniques, there are the blood-letting puncture using the implement of acupuncture to the Jing points, Extra points and superficial blood vessels and the acupuncture using the Hirudo. The methods of the blood-letting puncture are classified into the venous blood-letting puncture, the pricking , the picking out white fiber-like substances from the subcutaneous tissue, the cluster needling, the scattered needling, the blood-letting puncture of the tready collateral branch of the large channel and the blood-letting puncture of skin. The He-Ne laser with low energy ILIB through the superficial venules belongs to the Oriental medical treatment as the method of the blood-letting puncture in the vein of cubital fossa. The He-Ne laser with low energy ILIB has an effect on hyperfibrinogenemia, hyperlipidemia, speech and motor dysfunction in the case of cerebral infarction, headache, dizziness, pain and numbness. It is considered that fundamental research on the biological change of the human body, the experimental animal and the unicellular animal, and research on the effectiveness and the safety, and the development of He-Ne laser with low energy ILIB of an effective wavelength range are necessary.

  • PDF

Electrical properties of n-ZnO/p-Si heterojunction photovoltaic devices

  • Kang, Ji Hoon;Lee, Kyoung Su;Kim, Eun Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.306.1-306.1
    • /
    • 2016
  • ZnO semiconductor material has been widely utilized in various applications in semiconductor device technology owing to its unique electrical and optical features. It is a promising as solar cell material, because of its low cost, n-type conductivity and wide direct band gap. In this work ZnO/Si heterojunctions were fabricated by using pulsed laser deposition. Vacuum chamber was evacuated to a base pressure of approximately $2{\times}10^{-6}Torr$. ZnO thin films were grown on p-Si (100) substrate at oxygen partial pressure from 5mTorr to 40mTorr. Growth temperature of ZnO thin films was set to 773K. A pulsed (10 Hz) Nd:YAG laser operating at a wavelength of 266 nm was used to produce a plasma plume from an ablated a ZnO target, whose density of laser energy was $10J/cm^2$. Thickness of all the thin films of ZnO was about 300nm. The optical property was characterized by photoluminescence and crystallinity of ZnO was analyzed by X-ray diffraction. For fabrication ZnO/Si heterojunction diodes, indium metal and Al grid patterns were deposited on back and front side of the solar cells by using thermal evaporator, respectively. Finally, current-voltage characteristics of the ZnO/Si structure were studied by using Keithly 2600. Under Air Mass 1.5 Global solar simulator with an irradiation intensity of $100mW/cm^2$, the electrical properties of ZnO/Si heterojunction photovoltaic devices were analyzed.

  • PDF

THE EFFECT OF CO2 LASER ON DENTAL PULP OF DOG (CO2 laser조사가 성견치수에 미치는 영향에 관한 실험적 연구)

  • Kim, Hee-Joong;Lee, Chan-Young;Lee, Sung-Jong;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.7-19
    • /
    • 1988
  • The object of this paper was to investigate the histopatological changes on dog's pulp under cavitation by irradiation of the $CO_2$ laser. The subjects were derived from four dogs, and irradiated 113.23 J/$mm^2$, 283.09 J/$mm^2$, 566.08 J/$mm^2$ in Group I, II, and III respectively. The dogs were sacrificed immediately, 24 hour, 72 hour and 1 week after $CO_2$ laser treatment. For light microscopic examination, routine H-E and PAS stains were employed. For electron microscopic observation, the teeth were fixed in 1% paraformaldehyde and 1% glutaraldehyde, decalcified teeth in 10% EDTA were stained by uranyl acetate and lead citrate. The observation was made with a Hitachi H-500 model electron microscope. The following results were obtained in this study: 1. At the early stage of the experimental sub-groups-immediately, 24 hour, 72 hour samples of Group I, II and III-coagulation necrosis and hyperemia were observed in odontoblastic and subodontoblastic pulpal layer. 2. At the 1 week sub-group of Group I, II, regenerative hyperplasia of the odontoblasts without coagulation necrosis were revealed, in addition to thickened predentin. On he other hand coagulation necrosis and atrophic change accompanying with hyperplasia were found at the 1 week sub-group of Group III. 3. Ultrastructurally, the odontoblasts appeared nuclear degeneration, vacuolar change of cytoplasmic organelles and rupture of plasma membrane at the early stage of the experimental period of all groups. 4. Under spectrohelioscopic examination, regenerative odontobalsts were seen at the 1 week specimens of Group I, II and III. 5. The pulpal response occured at 113-566 J/$mm^2$. The pathologic change of pulp tissue occured at the early experimental period but regeneration of odontoblasts could be seen after 1 week.

  • PDF

Manufacturing Process of Self-Luminous Glass Tube (SLGT) Utilizing Tritium Gas (I) (삼중수소 활용을 위한 자발광유리관 (SLGT) 제조기술)

  • Kim Kwangsin;Kim Kyeongsook;Chung Eun-Su;Son Soon Hwan;Nam Gi-Jung
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.87-95
    • /
    • 2005
  • Laser sealing/cutting technique, one of the 4 core technologies to manufacture self-luminous glass tubes (SLGTs) has been developed. Through the analysis of commercial products it is found that Pyrex Is used for SLGTs. A CO2 laser, which is commonly used for glass work was used for the study The factors affecting the sealing/cutting were laser intensity, duration. Irradiation method, and pressure inside the tube. The whole Process is composed of 2 stages. In the first stage. both ends of the tubes are sealed while tritium is insected in the tubes. And the tritium sealed tubes are cut in the desired size in the second stage. Defocused beam was used for seal ing and focused beam was used for cutting. After the sealing/cutting, the tubes were heat treated to prevent fracture due to the residual heat stress.

  • PDF

Development of $1.06/1.32{\mu}m$ Nd:YAG Laser and Dental Applications ($1.06/1.32{\mu}m$ Nd:YAG 레이저 개발 및 치과용 임상적용 연구)

  • Yoon, G.;Kim, H.S.;Hong, T.M.;Kim, J.B.;Lee, S.C.;Kim, W.K.;Zabaznov, A.;Tsvetkov, V.;Kim, J.H.;Oh, S.R.;Moon, J.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.192-196
    • /
    • 1996
  • [ $1.06/1.32{\mu}m$ ] dual-wavelength medical laser was developed and preliminary clinical comparisons at these two wavelengths were performed for dental application. We could develop a compact laser system 1) by lasing two wavelengths from the same Nd:YAG rod, and 2) by introducing high-voltage switching power supply modules. Experiment on gingiva of pig jaw showed higher thermal damage at $1.32{\mu}m$. Depending on particular procedures, each wavelength has its own advantages and disadvantages. For cutting, however, using conical tips rather than bare fibers provided better results with low threshold of cutting energy and less surrounding thermal damage. Appling light-absorbing dye on target area appeared to induce more damage during laser irradiation. However, histological studies showed no significant difference whether dye was applied or not.

  • PDF

In vivo evaluation of infrared LASER mediated drug release of PLA-tetracycline complexes coated gold nanoparticle-titania nanotubes with mouse (마우스를 이용한 PLA - tetracycline 복합체 코팅 금 나노입자 - 티타니아 나노튜브의 적외선 레이저 유도 약물용출 생체 내 평가)

  • Moon, Kyung-Suk;Jeoung, Chan-Gwoun;Bae, Ji-Myung;Oh, Seunghan
    • Korean Journal of Dental Materials
    • /
    • v.44 no.1
    • /
    • pp.33-41
    • /
    • 2017
  • In this study, we prepared PLA-tetracycline complexes coated gold nanoparticle-titania nanotubes and estimated their infrared LASER mediated drug release in the abdominal region of ICR mouse. The results of UV-Vis spectrophotometer showed the highest absorbance at the wavelength of 530 nm and 809 nm indicating the existence of gold nanoparticles. EDX analysis showed that the amounts of gold nanoparticle coated on titania nanotubes were approximately 3.62-36.5 wt%. In vivo test resulted that the tetracycline release value of experimental groups (6.5 ng/mL) was higher than that of control group (5.8 ng/mL) on the condition of 30 minutes of LASER irradiation. Therefore, it is expected that PLA-tetracycline complexes coated gold nanoparticle-titania nanotubes have the feasibility in the field of infrared remote controlled drug device and overcome the limitation of location and time of drug release in dental implant.

Application of Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Characterization of U-7Mo/Al-5Si Dispersion Fuels

  • Lee, Jeongmook;Park, Jai Il;Youn, Young-Sang;Ha, Yeong-Keong;Kim, Jong-Yun
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.645-650
    • /
    • 2017
  • This technical note demonstrates the feasibility of using laser ablation inductively coupled plasma mass spectrometry for the characterization of U-7Mo/Ale5Si dispersion fuel. Our measurements show 5.0% Relative Standard Deviation (RSD) for the reproducibility of measured $^{98}Mo/^{238}U$ ratios in fuel particles from spot analysis, and 3.4% RSD for $^{98}Mo/^{238}U$ ratios in a NIST-SRM 612 glass standard. Line scanning allows for the distinction of U-7Mo fuel particles from the Al-5Si matrix. Each mass spectrum peak indicates the presence of U-7Mo fuel particles, and the time width of each peak corresponds to the size of that fuel particle. The size of the fuel particles is estimated from the time width of the mass spectrum peak for $^{98}Mo$ by considering the scan rate used during the line scan. This preliminary application clearly demonstrates that laser ablation inductively coupled plasma mass spectrometry can directly identify isotope ratios and sizes of the fuel particles in U-Mo/Al dispersion fuel. Once optimized further, this instrument will be a powerful tool for investigating irradiated dispersion fuels in terms of fission product distributions in fuel matrices, and the changes in fuel particle size or shape after irradiation.

Combined effect of recombinant human bone morphogenetic protein-2 and low level laser irradiation on bisphosphonate-treated osteoblasts

  • Jeong, Seok-Young;Hong, Ji-Un;Song, Jae Min;Kim, In Ryoung;Park, Bong Soo;Kim, Chul Hoon;Shin, Sang Hun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.6
    • /
    • pp.259-268
    • /
    • 2018
  • Objectives: The purpose of this study was to evaluate the synergic effect of recombinant human bone morphogenetic protein-2 (rhBMP-2) and low-level laser therapy (LLLT) on bisphosphonate-treated osteoblasts. Materials and Methods: Human fetal osteoblast cells (hFOB 1.19) were cultured with $100{\mu}M$ alendronate. Low-level Ga-Al-As laser alone or with 100 ng/mL rhBMP-2 was then applied. Cell viability was measured with MTT assay. The expression levels of receptor activator of nuclear factor kappa-B ligand (RANKL), macrophage colony-stimulating factor (M-CSF), and osteoprotegerin (OPG) were analyzed for osteoblastic activity inducing osteoclastic activity. Collagen type and transforming growth factor beta-1 were also evaluated for bone matrix formation. Results: The results showed that rhBMP-2 and LLLT had a synergic effect on alendronate-treated osteoblasts for enhancing osteoblastic activity and bone matrix formation. Between rhBMP-2 and LLLT, rhBMP-2 exhibited a greater effect, but did not show a significant difference. Conclusion: rhBMP-2 and LLLT have synergic effects on bisphosphonate-treated osteoblasts through enhancement of osteoblastic activity and bone formation activity.

Microstructural Analysis of STS316L Samples Manufactured by Powder Bed Fusion and Post-heat Treatments (Powder Bed Fusion 공정으로 제조한 STS 316L의 미세조직과 후속 열처리 특성)

  • Song, S.Y.;Lee, D.W.;Cong, D.V.;Kim, J.W.;Lee, S.M.;Joo, S.H.;Kim, Jin-Chun
    • Journal of Powder Materials
    • /
    • v.29 no.1
    • /
    • pp.14-21
    • /
    • 2022
  • In the powder bed fusion (PBF) process, a 3D shape is formed by the continuous stacking of very fine powder layers using computer-aided design (CAD) modeling data, following which laser irradiation can be used to fuse the layers forming the desired product. In this method, the main process parameters for manufacturing the desired 3D products are laser power, laser speed, powder form, powder size, laminated thickness, and laser diameter. Stainless steel (STS) 316L exhibits excellent strength at high temperatures, and is also corrosion resistant. Due to this, it is widely used in various additive manufacturing processes, and in the production of corrosion-resistant components with complicated shapes. In this study, rectangular specimens have been manufactured using STS 316L powder via the PBF process. Further, the effect of heat treatment at 800 ℃ on the microstructure and hardness has been investigated.

Analysis of Heavy Metal Concentration in Construction By-Products using Laser-Induced Breakdown Spectroscopy and Membrane Techniques (레이져 유도 플라즈마 분광법(LIBS)과 멤브레인을 활용한 건설용 부산물 내 중금속 분석에 관한 연구)

  • Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.2
    • /
    • pp.113-121
    • /
    • 2023
  • In this study, the applicability and reproducibility of laser induced breakdown spectroscopy(LIBS) for heavy metal analysis in clinker and 5 types of by-products(crushed stone sludge, blast furnace slag, steel slag, waste concrete sludge, bottom ash) were experimentally reviewed. As a result of ICP-MS, XRF, and LIBS analysis of the six samples, the difference between ICP and XRF was confirmed in the quantitative analysis, but the LIBS analysis showed a difference by element from the standard analysis, and only qualitative analysis of the sample was possible. LIBS analysis wavelength was set for three types of heavy metals(Cd - 214.44nm, Pb - 405.78nm, Hg - 253.65nm). As a result of laser irradiation on the surface of the membrane impregnated with a solution of each concentration(1~1000ppm) and dried, the correlation between the spectral intensity and the concentration was confirmed.