• Title/Summary/Keyword: Laser doppler

Search Result 480, Processing Time 0.033 seconds

Laser Doppler Vibrometer with Self Vibration Compensation (자체 진동 보상기능을 가진 레이저 도플러 진동측정계에 관한 연구)

  • Lee, Young-Jin;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.53-55
    • /
    • 2001
  • A dual probe laser Doppler vibrometer (LDV) that has one laser source and provides two independent object beams has been developed for the first time. An electronic circuit that converts light signal to electronic signal has been also developed using phase locked loop(PLL). It was found that this types of dual probe LDV can be used in differential mode and self-vibration compensation mode.

  • PDF

Laser Doppler Vibrometer with self vibration compensation (자체 진동 보상기능을 가진 레이저 도플러 진동측정계에 관한 연구)

  • Lee, Young-Jin;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1838-1840
    • /
    • 2001
  • A dual probe laser Doppler vibrometer (LDV) that has one laser source and provides two independent object beams has been developed for the first time. An electronic circuit that converts light signal to electronic signal has been also developed using digital phase locked loop(DPLL). It was found that this types of dual probe LDV can be used in differential mode and self-vibration compensation mode.

  • PDF

MEASUREMENT OF PULPAL BLOOD FLOW USING A LASER DOPPLER FLOWMETER (Laser Doppler flowmeter를 이용한 치수혈류 측정)

  • Ban, Tae-Whan;Lee, Jae-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.560-569
    • /
    • 1999
  • Blood supply rather than nerve supply implies pulp vitality. To evaluate pulp vitality clinically, electric pulp test and thermal test which are based on sensory nerve response have been used in addition to many auxiliary data such as past dental history, visual inspection, radiographic examination, percussion, palpation and transillumination test. However, reactivity of the nerves to the stimulation is not synonymous with normalcy. Therefore measurement of pulpal blood flow using a laser Doppler flowmeter became a new trial to test the pulp vitality. The purpose of the present study was to evaluate normal pulpal blood flow level of maxillary teeth in adult to provide a guideline in determining the vitality of dental pulp. Pulpal blood flow was measured in maxillary central and lateral incisors, canines, first and second premolars and first molars of seventy nine adults of 22 - 30 years old using a laser Doppler flowmeter (PeriFlux 4001, Perimed Co., Stockholm, Sweden, 780 nm infrared laser, 1mW). For directly-made splints, silicone rubber impressions were taken directly from the mouth. For indirectly-made splints, alginate impressions were taken from the mouth and stone cast were made. After making depressions on the buccal surfaces of the cast teeth to indicate the hole positions, second impressions with vinyl polysyloxane putty were taken from the cast. Holes for the laser probes were made at the putty impressions 4mm above the gingival level. Laser probe (PF416 dental probe, 1.5mm) was inserted in the prepared hole and the splint was set in the mouth. After 10 minutes of patient relaxing, pulpal blood flow was recorded for 5 minutes on each tooth. The recorded flow was saved in the computer and calculated with a software 'Perisoft' version 5.1. Pulpal blood flow was also recorded in six teeth of five individuals with no response to electric pulp test and cold test, with periapical radiolucency, or with history of root canal treatment to compare with nonvital teeth. The difference between the mean flow values of each group of teeth were analyzed using one-way ANOVA and Duncan's Multiple Range test. The results were as follows: 1. The average pulpal blood flow values of all the tested teeth of each location were between 9 - 16 Perfusion Unit. Pulpal blood flow value was highest in maxillary lateral incisors, followed by first premolars, second premolars, canines, central incisors, and then first molars (p<0.01). 2. In six anterior teeth, indirectly-made splint group showed higher pulpal blood flow values than directly-made splint group (p<0.01). In posterior teeth, however, there was no significant flow value difference between directly-made splint group and indirectly-made splint one (p>0.05). 3. Teeth with vital pulps showed higher signal values than teeth with nonvital pulps (p<0.01), and the flow photographs showed heartbeat-synchronous fluctuations and vasomotions, while those were absent in non vital tooth.

  • PDF

Measurement of Mode Shape By Using A Scanning Laser Doppler Vibrometer (스캐닝 레이저 도플러 진동계를 이용한 모드 해석)

  • Gang, Min-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2560-2567
    • /
    • 2000
  • When spatially dense velocity distribution is measured by a scanning laser Doppler vibrometer, the Fourier transform method provides the real and imaginary parts of the mode shapes in the form of a polynomial. However the Fourier transform method is often impractical because the independent decomposition property of cosine and sine components into real and imaginary parts, respectively, does not hold due to the leakage problem which commonly occurs in the Fourier transform of harmonic signals. To deal with this problem, a Hilbert transform method is newly proposed in this article. The proposed method is free from the leakage problem and relatively robust to the scanning error. A simulation example is provided to verify the effectiveness of this method.

Measurement of Mode Shape By Using A Scanning Laser Doppler Vibrometer (스캐닝 레이저 도플러 진동 측정기를 이용한 모드 측정)

  • Kang, Min-Sig
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.420-425
    • /
    • 2000
  • When spatially dense velocity distribution is measured by a scanning laser Doppler vibrometer, the Fourier transform method provides the real and imaginary parts of the mode shapes in the form of a polynomial. However the Fourier transform method is often impractical because the independent decomposition property of cosine and sine components into real and imaginary parts, respectively, does not hold due to the leakage problem which commonly occurs in the Fourier transform of harmonic signals. To deal with this problem, a Hilbert transform method is newly proposed in this article. The proposed method is free from the leakage problem and relatively robust to tire scanning error. A simulation example is provided to verify the effectiveness of this method.

  • PDF

Measurement of Velocity Profiles in the Laminar Free Convection Boundary Layer on A Uniformly Heated Vertical Flat Plate by A Laser- Doppler Velocimeter (수직평판의 자연대류 경계층에서의 유속의 Laser-Doppler 유속계에 의한 측정)

  • ;;Lee, Jeong Bae
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.3 no.1
    • /
    • pp.27-34
    • /
    • 1979
  • The velocity profiles in the laminar free convection boundary layer on a uniformly heated vertical plate are measured by a Laser Doppler Velocimeter for air in the range of modified Grashof number G $r_{\chi}$*=1.172x10$^{9}$ . The fringe mode, forward scatter type of the LDV system is used and the small magnesium oxide particles are used for the scattering pafticles. The analytical non-dimensionalized velocity profiles are obtained by use of an analog computer for the comparison with the experimental results. The experimental reults are in good agreement with the analytical solution obtained with an aid of the analog computer.er.

Measurement of angular velocity using the self-mixing effect of semiconductor laser (되먹임 효과를 이용한 회전체의 속도측정)

  • 이병욱
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.250-254
    • /
    • 2000
  • We have constructed laser Doppler velocimetry system using self-mixing effect with a semiconductor laser. This technology is based on the frequency mixing phenomena which occurs when light scattered back from the moving object into the laser cavity interferes with light inside the laser. We have compared the value of Doppler shifted frequency with the velocity variation of the wheel. Frequency dependence on the angle between the moving direction of rotating aluminum wheel and the incident beam also have been proved. As an illustration of the performance of the velocimeter, velocity measurements of a rotating disk are described. Doppler signal shows a good linear relationship with velocity of rotating disk.

  • PDF

Blood Flow in an Aortic Bifurcation Model: Pulsed Doppler Ultrasound and Laser Doppler Anemometry Studies (대동맥분기에서의 혈액유동: 맥도플러초음파 및 레이저도플러계측기를 사용한 연구)

  • Kim, Young-H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.43-46
    • /
    • 1992
  • $\underline{In\;vitro}$ velocity measurements were made using both the pulsed Doppler ultrasound (PDU) machine and laser Doppler anemometer (LDA) system in order to investigate the flow characteristics near the aortic bifurcation. Velocities measured from the PDU machine was in good agreement with those from the LDA. The flow in the daughter branches was three-dimensional with a secondary flow. The oscillating wall shear stress with this secondary fluid motion is well correlated with the localization of the atherosclerosis.

  • PDF

Three-Dimensional Flow in an Aortic Bifurcation Model: Comparison of In Vitro Experiments and Numerical Simulation (대동맥 분기관 모델 내 삼차원 유동: In vitro 실험과 수치해석의 비교)

  • Kim, Young-H.;Seo, Sang-H.;Ryu, Sang-S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.15-18
    • /
    • 1995
  • Three-dimensional steady and pulsatile flow experiments and numerical simulations have conducted to investigate the flow characteristics in the aortic bifurcation model. In vitro velocity measurements were made using both laser Doppler anemometry and pulsed Doppler ultrasound velocimetry. In this study, flow phenomena in the aortic bifurcation model are discussed extensively and the numerical results are compared with experimental results.

  • PDF