• 제목/요약/키워드: Laser Scattering

검색결과 407건 처리시간 0.03초

레이저 및 열전대를 이용한 동축류 확산화염에서의 매연입자 측정에 관한 연구 (A Study on the Soot Particle Measurement in Co-flow Diffusion Flame Using a Laser Diagnostics and a Thermocouple)

  • 한용택;이기형;이원남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1267-1273
    • /
    • 2004
  • The temperature and soot particle measurement technique in a laminar diffusion flame have been studied to investigate the characteristics of soot particle with temperature using a co-flow burner. The temperature distributions in the flame were measured by rapid insertion of a R-type thermocouple and the soot particles were detected were detected by LEM/LIS techniques. In these measurement, soot volume fraction, number density and soot diameters were analyzed experimentally. As a results, the spacial distributions of particle volume fraction, soot diameter, and number density are mapped throughout the flame using the Rayleigh theory for the scattering of light by absorbing particles. A laser extinction method was used to measure the soot volume fraction and Laser induced scattering method was used to measure the soot particle diameter and number density. Also, we measured temperature without the effect of soot particles attached to the thermocouple junction, which is close to the nozzle. In this result, we found that upstream zone has a unstable flowing in co-flow diffusion flame and the y-axis temperature of flame has a uniform temperature distribution in the most soot volume fraction zone.

  • PDF

광 산란방법을 이용한 계면활성제 농도측정 (Measurement of Surfactant Concentration Using Light Scattering Method)

  • 조영현;조경현;정치섭
    • 대한환경공학회지
    • /
    • 제39권8호
    • /
    • pp.441-448
    • /
    • 2017
  • 본 연구에서는 미세기포를 산란체로 사용한 편광산란 측정법을 이용하여 수중 계면활성제의 농도를 측정하는 방법을 개발하였다. Mueller 요소 $M_{11}$은 계면활성제의 농도가 0 ppm부터 60 ppm 사이 영역에서 농도와 선형적인 비례관계를 가져 계면활성제 농도를 측정할 수 있는 유용한 파라메터로 사용될 수 있음을 알았다. 이 측정은 산란각이 150도, 소광비가 56.2 조건에서 가장 효과적 이였다. 이 연구 결과를 볼 때, 편광산란 측정법(EPLS)은 강이나 호수에서 수질을 실시간적으로 모니터하는데 있어 충분히 효과적인 수단으로 보인다.

Development of Ultrasonic Wave Propagation Imaging System

  • Chia, Chen-Ciang;Lee, Jung-Ryul;Kim, Jong-Heon
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.283-292
    • /
    • 2009
  • Laser-based ultrasonic sensing requires the probe with fixed fecal length, but this requirement is not essential in laser-based ultrasonic generation. Based on this fact, we designed a pulsed laser-based ultrasonic wave propagation imaging (UWPI) system with a tilting mirror system for rapid scanning of target, and an in-line band-pass filtering capable of ultrasoaic mode selection. 1D-temporal averaging, 2D-spatial averaging, and 3D-data structure building algorithms were developed far clearer results allowing fur higher damage detectability. The imaging results on a flat stainless steel plate were presented in movie and snapshot formats which showed the propagation of ultrasound visible as a concentric wavefield emerging from the location of an ultrasonic sensor. A hole in the plate with a diameter of 1 mm was indicated by the scattering wavefields. The results showed that this robust UWPI system is independent of focal length and reference data requirements.

Multi-kilowatt Single-mode Ytterbium-doped Large-core Fiber Laser

  • Jeong, Yoon-Chan;Boyland, Alexander J.;Sahu, Jayanta K.;Chung, Seung-Hwan;Nilsson, Johan;Payne, David N.
    • Journal of the Optical Society of Korea
    • /
    • 제13권4호
    • /
    • pp.416-422
    • /
    • 2009
  • We have demonstrated a highly efficient cladding-pumped ytterbium-doped fiber laser, generating $>$2.1 kW of continuous-wave output power at 1.1 μm with 74% slope efficiency with respect to launched pump power. The beam quality factor ($M^2$) was better than 1.2. The maximum output power was only limited by available pump power, showing no evidence of roll-over even at the highest output power. We present data on how the beam quality depends on the fiber parameter, based on our current and past fiber laser developments. We also discuss the ultimate power-capability of our fiber in terms of thermal management, Raman nonlinear scattering, and material damage, and estimate it to 10 kW.

APPLICATION OF TIME-OF-FLIGHT NEAR INFRARED SPECTROSCOPY TO WOOD

  • Tsuchikawa, Satoru;Tsutsumi, Shigeaki
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1182-1182
    • /
    • 2001
  • In this study, the newly constructed optical measurement system, which was mainly composed of a parametric tunable laser and a near infrared photoelectric multiplier, was introduced to clarify the optical characteristics of wood as discontinuous body with anisotropic cellular structure from the viewpoint of the time-of-flight near infrared spectroscopy (TOF-NIRS). The combined effects of the cellular structure of wood sample, the wavelength of the laser beam λ, and the detection position of transmitted light on the time resolved profiles were investigated in detail. The variation of the attenuance of peak maxima At, the time delay of peak maxima Δt and the variation of full width at half maximum Δw were strongly dependent on the feature of cellular structure of a sample and the wavelength of the laser beam. The substantial optical path length became about 30 to 35 times as long as sample thickness except the absorption band of water. Δt ${\times}$ Δw representing the light scattering condition increased exponentially with the sample thickness or the distance between the irradiation point and the end of sample. Around the λ=900-950 nm, there may be considerable light scattering in the lumen of tracheid, which is multiple specular reflection and easy to propagate along the length of wood fiber. Such tendency was remarkable for soft wood with the aggregate of thin layers of cell walls. When we apply TOF-NIRS to the cellular structural materials like wood, it is very important to give attention to the difference in the light scattering within cell wall and the multiple specular-like reflections between cell walls. We tried to express the characteristics of the time resolved profile on the basis of the optical parameters for light propagation determined by the previous studies, which were absorption coefficient K and scattering coefficient S from Kubelka-Munk theory and n from nth power cosine model of radiant intensity. The wavelength dependency of the product of K/S and n, which expressed the light-absorbing and -scattering condition and the degree of anisotropy, respectively, was similar to that of the time delay of peak maxima Δt. The variation of the time resolved profile is governed by the combination of these parameters. So, we can easily find the set of parameters for light propagation synthetically from Δt.

  • PDF

주파수 영역 분광법을 이용한 다중산란 매질의 광학계수 측정 (Measurement of optical coefficients of multiple scattering media by using frequency domain spectroscopy)

  • 전계진;윤길원;김건식;전성만;박승한
    • 한국광학회지
    • /
    • 제10권5호
    • /
    • pp.357-363
    • /
    • 1999
  • 다중산란매질의 광학계수를 측정하기 위하여 광세기의 변화와 위상차이를 동시에 측정하는 주파수 영역 분광장치를 구성하고, 산란과 흡수가 다른 매질 조건하에서 진폭 변조된 광을 입사시킨 후 후방 산란광의 교류 및 위상지연 성분을 heterodyne 검지 방법을 이용하여 측정하였다. 실험을 통하여 산란자와 흡수체의 농도가 증가함에 따라 흡수계수와 수송산란 계수는 선형적으로 증가함을 확인할 수 있었으며, 흡수계수와 수송산란계수를 확산이론을 이용하여 구할 수 있었다. 광원과 검출기의 거리, 변조주파수에 따라 측정 가능한 광학계수의 범위를 분석하였다. 레이저 다이오드를 사용하는 소형화된 이 장치는 생체조직과 같은 다중 산란매질의 비침습적 광학계수 측정에 이용될수 있으리라 기대된다.

  • PDF

형과/산란광 동시 측정에 의한 GDI 분무의 평균 입경 분포에 관한 연구 (Average Droplet Size Distribution of a GDI Spray by Simultaneous Fluorescence/Scattering Image Technique)

  • 곽수민;류경훈;최동석;김덕줄
    • 대한기계학회논문집B
    • /
    • 제25권6호
    • /
    • pp.868-875
    • /
    • 2001
  • The objective of this study is to investigate the average droplet size distributions of a GDI spray by simultaneous fluorescence/scattering image technique. GDI engine is recently very popular because of high engine efficiency and low emissions. However, the injectors must have good spray characteristics because the fuel is directly injected into the cylinder. The fuel mixtures used in this study were 2% of fluorobenzene, 9% of DEMA(diethyl-methyl-amine) and 89% of hexane by volume. The system for obtaining 2-D fluorescence/scattering images of fuel spray was constituted of a laser sheet, a doubling prism, optical filters, and an ICCD camera. Using the ratio of the fluorescence to the scattering intensities, SMD distributions were obtained. SMD measured by the technique was compared with that obtained by PDA. It was found that average droplet size was bigger at spray center in the early stage of injection and at the outer periphery of the spray in the late stage of injection.

전광섬유 MOPA 시스템 기반 10 GHz 선폭을 갖는 1.5 kW 단일모드 이터븀 첨가 편광유지 광섬유 레이저 (All-fiber 1.5-kW-class Single-mode Yb-doped Polarization-maintaining Fiber Laser with 10 GHz Linewidth)

  • 정성묵;김기혁;김태균;이성헌;양환석;이준수;이광현;이정환;조민식
    • 한국광학회지
    • /
    • 제31권5호
    • /
    • pp.223-230
    • /
    • 2020
  • 본 논문에서는 전광섬유 master oscillator power amplifier (MOPA) 구조의 이터븀(ytterbium) 첨가 편광유지 광섬유 레이저의 유도 브릴루앙 산란 및 모드 불안정 특성에 대해 연구하였다. 이터븀 첨가 광섬유 및 신호 광원의 종류에 따라 레이저 출력 및 역반사 스펙트럼을 측정하여 광섬유 레이저의 출력 증폭 한계를 분석하였다. 레이저 구조의 최적화를 통해 단일모드 빔 품질을 갖는 전광섬유 고출력 편광유지 광섬유 레이저를 구현하였다. Pseudo-random binary sequence (PRBS) 신호에 의해 위상변조된 10 GHz의 선폭을 갖는 신호 광원을 적용하여 1.5 kW의 출력을 얻었다. 최대 출력에서 1.15의 빔 품질을 가지며, 17 dB 이상의 편광소광률 특성을 확인하였다.

레이저 Rayleigh 산란을 이용한 연료농도 계측시 잡음원인과 대책 (Fuel Concentration Measurements by Laser Rayleigh Scattering)

  • 권순태;이재원;박찬준;엄인용
    • 에너지공학
    • /
    • 제17권4호
    • /
    • pp.189-197
    • /
    • 2008
  • 본 연구는 정상 상태의 유동에서 Rayleigh 산란을 이용하여 연료 농도를 측정시 잡음 원인과 대책에 관한 것이다. 실험 장치는 연료 농도 변화를 시간적, 공간적으로 측정함과 동시에 정확한 농도 측정을 위한 보정도 가능하도록 구성하였다. 실험 장치를 우선 보정 용기에 적용하여 프로판, 부탄, 아세틸렌, 프레온 가스의 산란단면적을 구하였다. 이후 내연기관을 상사한 실린더 헤드, 인젝터, 흡기매니폴드, 투명 실린더로 구성된 정상유동 장치를 구성하였다. Rayleigh 산란을 이용한 농도 측정 시 가장 큰 난점은 Mie 산란에 의한 간섭이다. Mie 산란의 영향을 제거하기 위해 하드웨어 필터로 입자의 수 밀도를 측정 가능한 수준으로 감소시켰다. Mie 산란 입자를 충분히 작게 만든 후 광전자 증배관과 앰프의 시정수에 바탕을 둔 소프트웨어 필터를 개발하여 적용하였다. 그리고 바탕 잡음은 광학적 배열을 조정하고 동시에 핀 홀과 빔 트랩을 적용하여 감소시켰다. 실험 결과 LRS는 연료 농도 계측에 매우 유용하게 이용될 수 있고 소프트웨어 필터는 Mie 간섭을 효과적으로 제거할 수 있음을 확인하였다.