• Title/Summary/Keyword: Laser Focusing

Search Result 175, Processing Time 0.03 seconds

Development of An Automated Scanning Laser Doppler Vibrometer for Measurements of In-Plane Structural Vibration (평면 구조 진동 측정을 위한 자동화된 스캐닝 레이저 도플러 진동측정기의 개발 및 연구)

  • Kil, Hyun-Gwon
    • Journal of KSNVE
    • /
    • v.7 no.2
    • /
    • pp.231-238
    • /
    • 1997
  • An automated scanning laser Doppler vibrometer (LDV) has been designed, and built to measure in-plane vibration fields over structures. Use of optical fibers allows the compact design of a laser probe head which can be scanned over the vibrating structures. An algorithm for automated self-alignment of the laser probe is developed. The system is completely automated for scanning over the structures, focusing two laser beams at each data point until the detected vibration signal is stable, and for recording and transferring the data to a system computer. The automated system allows one to get extensive data of the vibration field over the structures. The system is tested by scanning a piezoelectric cylindrical shell and a plate excited by a continuous signal and by a pulse signal, respectively. Results show that the automated scanning LDV system can be a useful tool to measure the in-plane vibration field and to detect the elastic waves propagating on the vibrating structures.

  • PDF

The induced discharge characteristics in atmosphere adopting a pulsed $CO_2$ laser (펄스형 $CO_2$ 레이저를 이용한 기중 침 대 침 전극간의 유도방전 특성)

  • Jung, Yong-Ho;Choi, Jin-Young;Lee, Yu-Soo;Chung, Hyun-Ju;Song, Gun-Ju;Kim, Hee-Je
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.172-175
    • /
    • 2002
  • The technique of induced discharge by a pulsed CO2 laser is being applied to control electrical discharge path, material processing, triggered lightning for protecting the power equipments. In this paper, we have investigated about the characteristics of the induced discharge at atmospheric conditions by using a plasma channel, which is produced when a pulsed CO2 laser radiation is focused by a focusing mirror as a trigger source. A plasma channel produced by laser radiation has an effect on decreasing the threshold voltage and inducing the discharge in both needle electrodes. We have confirmed a delay time between a produced plasma channel and an electrical discharge after laser radiation. We provided the decreased voltage lower than the natural discharge voltage between electrode type of needles and was induced the discharge by forming a plasma channel between them. In this research we could understand the time delay of induced discharge by laser radiation, and the characteristics of the discharge cause by the decrease in the threshold voltage, and the polarity effect by changes of plasma channel positions between two electrodes.

  • PDF

Three-dimensional micro photomachining of polymer using DPSSL (Diode Pumped Solid State Laser) with 355 nm wavelength (355nm 파장의 DPSSL을 이용한 폴리머의 3차원 미세 형상 광가공기술)

  • 장원석;신보성;김재구;황경현
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.312-320
    • /
    • 2003
  • The basic mechanistic aspects of the interaction and practical considerations related to polymer ablation were briefly reviewed. Photochemical and photothermal effects, which highly depend on laser wavelength have close correlation with each other. In this study, multi-scanning laser ablation processing of polymer with a DPSS (Diode Pumped Solid State) 3rd harmonic Nd:YVO$_4$ laser (355 nm) was developed to fabricate a three-dimensional micro shape. Polymer fabrication using DPSSL has some advantages compared with the conventional polymer ablation process using KrF and ArF laser with 248 nm and 193 nm wavelength. These advantages include pumping efficiency and low maintenance cost. And this method also makes it possible to fabricate 2D patterns or 3D shapes rapidly and cheaply because CAD/CAM software and precision stages are used without complex projection mask techniques. Photomachinability of polymer is highly influenced by laser wavelength and by the polymer's own chemical structure. So the optical characteristics of polymers for a 355 nm laser source is investigated experimentally and theoretically. The photophysical and photochemical parameters such as laser fluence, focusing position, and ambient gas were considered to reduce the plume effect which re-deposits debris on the surface of substrate. These phenomena affect the surface roughness and even induce delamination around the ablation site. Thus, the process parameters were tuned to optimize for gaining precision surface shape and quality. This maskless direct photomachining technology using DPSSL could be expected to manufacture tile prototype of micro devices and molds for the laser-LIGA process.

Spectra of Optical-field Ionized Gases by a Femtosecond Ti:Sapphire Laser

  • Mock, Tomas;Shin, Hyun-Joon;Cha, Yong-Ho;Lee, Dong-Gun;Hong, Kyung-Han;Nam, Chang-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.50-53
    • /
    • 1998
  • We report on the spectroscopic investigation of optical-field ionized plasmas in the soft X-ray spectral region. The experiment was carried out by focusing pulses of the high-power Ti:Sapphire laser with an energy of ~ 40 mJ and time duration of ~30 fs into a gas jet of krypton, xenon, and argon from a pulsed nozzle. Strong soft X-ray emission on lines from ionic stages of $Kr^{7+} , Kr^{8+} , Xe^{7+} , Ar^{7+} , and Ar^{8+}$ is reported. The experimental result was found to be in good agreement with theoretical prediction.

Compact and precision range finder using self-mixing semiconductor laser

  • Shinohara, Shigenobu;Andou, Minoru;Yoshida, Hirofumi;Ikeda, Hiroaki;Miyata, Masafumi;Yoshida, Jun-Ichi;Nishide, Ken-Ichi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.972-978
    • /
    • 1989
  • Proposed is improved compact self-mixing type semiconductor-laser range finder, which measures mode-hop time interval (MHI). Measurement error caused by the fluctuation of MHI is greatly reduced by averaging many contiguous MHI's. The main cause of measurement error 1.5% at ranges from 0.1m to 0.8m is attributed to the optical phase change of a returned light from a focusing lens. Accuracy improvement by stabilization of the returned light is suggested.

  • PDF

Gravitational-Wave Astronomy (중력파 천문학)

  • Kim, Chunglee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.31.3-31.3
    • /
    • 2016
  • Exploring a universe with gravitational waves (GWs) was only theoretical expectation for long time. In September 2015, the Laser Interferometer GW Observatory (LIGO) first detected GWs emitted from the collision of two stellar-mass black holes in cosmological distance (1.3 billion light years) on Earth. This confirms the existence of black-hole binary mergers, and further, opens a new field of GW astronomy. We begin our discussion with a list of important GW sources that can be detectable on Earth by large-scale laser interferometers such as LIGO. Focusing on compact objects such as neutron stars and black holes, we then discuss possible research in the context of GW astronomy. By coordinating with existing observatories, searching for electromagnetic waves or particles from astronomical objects, around the world, multi-messenger astronomy for the universe's most cataclysmic phenomena (e.g. gamma-ray bursts) will be available in the near future.

  • PDF

Laser therapy in peri-implantitis treatment: literature review (임플란트주위염 처치에서 레이저의 이용: 문헌고찰)

  • Lee, Kyung-Joong;Lee, Jong-Ho;Kum, Kee-Yeon;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.340-348
    • /
    • 2015
  • Peri-implantitis is the most common reason for a late failure and can occur even after years of successful osseointegration. The role of microbial plaque accumulation in the development of peri-implantitis has been well documented. On the other hand, the ideal method of implant surface decontamination to re-establish the health of peri-implant tissue remains to be determined. Removal of bacterial deposits is essential in the treatment of peri-implant infections, and various therapeutic approaches have been described in the literature, including mechanical debridement, disinfection with chemotherapeutic agents, and laser therapy. Recently, there has been a plenitude of scientific data regarding the use of laser irradiation to achieve titanium surface decontamination. Thus, research is focusing on lasers' potential use in the treatment of peri-implantitis. The aim of this literature review is to analyze and evaluate the efficacy of laser therapy for the treatment of peri-implantitis.

A Study on Polyamide-6 Sintering and Effect by $CO_2$ Laser ($CO_2$ Laser에 의한 Polyamide-6 소결과 그 영향에 관한 연구)

  • Bae S.W.;Kim D.S.;Ahn Y.J.;Kim H.I.;Choi K.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.197-198
    • /
    • 2006
  • In the solid freeform fabrication (SFF) system using selective laser sintering (SLS), polyamide-12 powder is currently recognized as general material. In this study, some kinds of polyamide-6 powders with different shape and particlesize were fabricated to investigate the formability, the microstructure and mechanical properties. Also, to develop a more elaborate and rapid system, this study employs a new SLS device with a 3-axis dynamic focusing scanner system instead of the existing fe lens used in commercial SLS. Polyamide-6 powders having the average size of 100 m were treated thermally in order to keep the spherical symmetry in shape. These polyamide-6 powders were mixed with polyamide-12 powders having the average size of 50 m to give the bimodal distribution of size. These mixed powders showed the better fabrication in the selective laser sintering process because the smaller particles of polyamide-11 played an important role in the compact packing of powders by filling the void space between the large particles of polyamide-6. Also, Experiments have performed to evaluate the effect of a scanning path and sintering parameters by fabricating the various 3D objects.

  • PDF

Continuous pulse width variable quenched dye laser (펄스폭 연속가변 Quenched Dye Laser)

  • 황선우;이영주;김성훈;최종운
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.152-156
    • /
    • 1999
  • We have developed the pulse-width variable Quenched Dye Laser (QDL). QDL consisted of the dye cell of 5 mm length containing a $2.5{\times}10^{-3}$[mol/l] solution of Rhodamine 6G and the cylindrical lens focal length of 150 mm and quenching mirror. QDL system was pumped by s XeCl excimer laser with 150 mJ pulse energy in a 20 ns pulse at 1 Hz repetition rate. Pulse-width of QDL was measured by a noncollinear intensity autocorrelator. The focused thckness was measured by changing the position of the focusing cylindrical lens. Pulse-width of QDL as a function of the focused thickness (273.0${\mu}{\textrm}{m}$~845.0${\mu}{\textrm}{m}$) varied continuously from 86 ps to 201 ps.

  • PDF

Laser Intensity Dependence in Resonant Multiphoton Ionization of Hg Atoms (수은 원자에서의 공명 다광자 이온화 과정의 레이저 강도 의존성)

  • 한재민;정도영;차형기;김철중;이종민
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.7-11
    • /
    • 1990
  • Resonant multi photon ionization (RMPD of Hg atoms is studied by focusing a high-power laser into the ionization cell. The intermediate resonant state is taken as $6d^1D_2$ with the 4-photon resonance wavelength of 560.7 nm. The ionization signal is measured as Hg vapor pressure (0.1-3.0 Torr), laser intensity $(10-120GW/\textrm{cm}^2)$, and laser wavelength (559-569 nm) vary. AC Stark shift and line broadening of the resonant state $(6d^1D_2)$ are observed and the shift factor is measured to be $-0.6(cm^{-1}/GW/\textrm{cm}^2$. It is also observed that the ionization signal increases as the Hg vapor pressure increases up to a certain value of pressure, however, if the pressure further increases, the signal decreases. The order of non-linearity, which discribes the laser intensity dependence of ionization rate, is measured to be 3 at the resonance, and compared with the theoretical results.esults.

  • PDF