• 제목/요약/키워드: Laser

검색결과 14,318건 처리시간 0.05초

나노 정밀도 스캐닝 용 공기베어링과 보이스 코일 모터의 초정밀 이중 스테이지 설계 및 제어 (Design and Control of Ultra-precision Dual Stage with Air bearings and Voice coil motor for nm scanning system)

  • 김기현;최영만;김정재;이문구;이석원;권대갑
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1883-1886
    • /
    • 2005
  • In this paper, a decoupled dual servo (DDS) stage for ultra-precision scanning system with large working range is introduced. In general, dual servo systems consist of a fine stage for short range and a coarse stage for long range. The proposed DDS also consists of a $XY\theta$ fine stage for handling and carrying workpieces and one axis coarse stage. Its coarse stage consists of air bearing guide system and a coreless linear motor with force ripple. The fine has four voice coil motors(VCM) as its actuator. According to a VCM's nature, there are no mechanical connections between coils and magnetic circuits. Moreover, VCM doesn't have force ripples due to imperfections of commutation components of linear motor systems - currents and flux densities. However, due to the VCM's mechanical constraints the working range of the fine is about $25mm^2$. To break that hurdle, the coarse stage with linear motors is used to move the fine about 500mm. Because of the above reasons, the proposed DDS can achieve higher precision scanning than other stages with only one servo. With MATLAB's Sequential Quadratic Programming (SQP), the VCMs are optimally designed for the highest force under conditions and constraints such as thermal dissipations due to its coil, its size, and so on. And for their movements without any frictions, guide systems of the DDS are composed of air bearings. To get precisely their positions, a linear scale with 5nm resolution are used for the coarse stage's motion and three plane mirror laser interferometers with 5nm for the fine's $XY\theta$ motions. With them, on scanning the two stages have same trajectories. The control algorithm is named Parallel method. The embodied ultra-precision scanning system has sub 100nm following error and in-positioning stability.

  • PDF

단일수평부력제트의 거동에 관한 실험적 연구 (Experimental Investigation on Behavior of Single Horizontal Buoyant Jet)

  • 서일원;권호중;권석재
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1011-1015
    • /
    • 2005
  • 본 실험에서는 부력 조건이 달라질 때 단공방류구에서 정체수역으로 수평방류되는 부력제트의 거동을 규명하였다. LIF (Laser Induced Fluorescence) 시스템을 이용하여 수행하였는데, LIF 시스템은 고해상도의 이미지를 취득할 수 있어 데이터의 정확도가 높으며, 동시에 한 평면상의 농도장을 일시에 측정할 수 있는 장점이 있는 기술이다. LIF 시스템은 크게 세부분으로 구성되어 있는데 방출시스템, 포착시스템, 처리시스템이 그것이다. 실험 조건을 고려해서 온수를 이용하여 주변수와의 밀도차를 재현하였으며, LIF 시스템의 추적입자로 형광염료 Rhodamine B를 사용하였다. 또한, 실험 데이터 취득과정에서 필요한 검정과정을 수행하였는데, LIF 시스템에서 검정과정은 레이저 입사광의 강도가 불균등한 분포를 가지는 점과 주변수의 매질에 의한 근의 감쇠가 발생하는 문제를 해결하기 위한 것이다. LIF 시스템은 부력제트의 농도장을 매우 정밀하게 측정할 수 있는데, 방류밀도 Froude 수가 변함에 따라 측정된 순간이미지를 통해 제트의 진화과정을 상세하고 가시적으로 확인할 수 있었다. 검정과정을 거친 농도 종단면에서 중심선의 연장선이 LIF 시스템에 의해 측정된 순간이미지의 중심선 궤적과 거의 일치하는 것도 알 수 있었다. 또한 LIF 시스템을 통해서 취득된 단일수평부력제트의 궤적과 중심선 희석률을 기존의 상용모형인 VISJET과 CORMIX1에 의해 예측된 결과와 비교$\cdot$분석한 결과, 제트 중심선 궤적의 경우, LIF 시스템을 이용한 측정값은 대체로 VISJET 모형의 결과와 일치하는 것으로 밝혀졌다. 중심선 희석률의 경우, LIF 측정값은 대체로 CORMIX1 모형, Cederwall(1968)의 경험식과 일치하는 경향을 보였다.0\%$일 때가 밸브를 $60\%$$80\%$ 개폐시켰을 때보다 $0.3kg/cm^2,\;0.29kg/cm^2$ 낮게 나타나 밸브를 전체 개방 했을 때 관로내의 수압이 상수설계기준에 적합한 수압을 유지함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히

  • PDF

막 단백질인 Proteorhodopsin과 Anabaena Sensory Rhodopsin의 다양한 측정 환경에 따른 광화학/생물리학적 특성 (Photochemical/Biophysical Properties of Proteorhodopsin and Anabaena Sensory Rhodopsin in Various Physical Environments)

  • 최아름;한송이;정영호;정광환
    • 미생물학회지
    • /
    • 제47권1호
    • /
    • pp.22-29
    • /
    • 2011
  • Chromophore로 레티날(vitamin A)을 사용하는 막 단백질인 로돕신은 7개의 막 단백질로 이루어진다. 최근 광화학/생물리학 측정 방법이 다양해지면서, 그에 따른 새로운 특성도 함께 다양하게 보고되고 있다. 하지만, 다양한 측정 환경에 따른 그 광화학/생물리학 특성의 차이점에 대한 비교연구는 없는 상태이다. 첫째, 빛 에너지를 이용하여 수소 이온 펌프 역할 하는 것으로 잘 알려져 있는 roteorhodopsin (PR)은 해양 proteobacteria에서 발견 되었다. 둘째, 한 오페론에서 14 kDa 전달자와 같이 발현되면서 신호 전달 기능을 하는 Anabaena sensory rhodopsin (ASR)이 있다. 이에 본 연구에서는 이 두 미생물 로돕신을 이용하여 다양한 조건에서 그 차이를 살펴보았다. 각 단백질이 막에 끼어 있는 상태(membrane state), polyacrylamide gel에 고정되어 있는 상태, nonionic detergent일종인 DDM (n-dodecyl-${\beta}$-D-maltopyranoside)과, OG (octyl-${\beta}$-D-glucopyranoside)에 녹아 있는 상태, 좀더 자연상태와 유사한 환경을 위해 단백질만 깨끗하게 정제한 다음 다시 Escherichia coli의 지질인 DOPC (1,2-didecanoyl-sn-glycero-3-phosphocholine)에 재조립한 상태, 이렇게 5가지 조건에서 각각의 광화학/생물리학 특징을 흡수스펙트럼(absorption spectrum), 빛-어둠 차이 흡수스펙트럼(light-induced difference spectrum), 포토사이클(photocycle)을 측정하였다. 그 결과 DDM에 녹아 있는 PR과 ASR에서 각 다른 파장에서 M과 O state와 같은 선명한 photointermediate를 가지고, 가장 signal/noise 비율이 좋았다. 본 연구를 통해 막단백질의 다양한 측정 환경에 대한 그 특성의 차이점을 살펴봄으로써 앞으로 다양한 종류의 로돕신 연구에 기초 기반이 될 것으로 사료된다.

이광자 광중합의 윤곽선 스캐닝법에 의한 마이크로 입체형상 제작 (Fabrication of Microstructures Using Double Contour Scanning (DCS) Method by Two-Photon Polymerization)

  • 박상후;임태우;이상호;양동열;공흥진;이광섭
    • 폴리머
    • /
    • 제29권2호
    • /
    • pp.146-150
    • /
    • 2005
  • 본 연구는 수십 마이크로미터 크기의 임의의 3차원 형상제작을 위한 이광자 광중합에 의한 나노 입체 리소그래피(nano-stereolithography) 공정개발에 관한 것이다. 본 연구에서 제안한 공정은 3차원 CAD 파일을 이용하여 형상의 윤곽선을 고화시켜서 연속적으로 적층하여 구조물을 제작하는 공정으로 기존의 리소그래피 공정과 달리 복잡한 형상제작이 가능하다. 형상제작은 펨토초 레이저를 이용하여 이광자 흡수 색소가 첨가된 아크릴레이트 계열의 단량체에 이광자 중합반응으로 제작하였으며 선 폭 정밀도는 150 nm수준이었다. 이광자 광중합법으로 윤곽선을 고화시켜 쉘(shell) 형태로 3차원 형상을 제작할 때에는 기계적 강성이 약하여 고화 후에 용매로 중합반응이 일어나지 않는 부분을 제거할 때 변형이 쉽게 발생하게 된다. 본 연구에서는 이러한 문제점을 해결하고자 윤곽 쉘 두께를 증가시켜 윤곽선을 중첩으로 제작하는 이중 윤곽선 스캐닝 방법(double contour scanning)을 시도하였으며 이를 통하여 제작된 형상의 강도가 향상됨을 확인할 수 있었다.

세팔 별모양 폴리스타이렌 사슬의 팽창에 대한 만능 환산 온도 파라미터의 적용 (Application of Universal Scaled Reduced Temperature Parameter to the Three-Arm Star Polystyrene)

  • 박일현;김용철
    • 폴리머
    • /
    • 제27권3호
    • /
    • pp.255-264
    • /
    • 2003
  • 세팔 별모양 폴리스타이렌 (PS, $M_{w}$=2.80$\times$$10^{5}$ , 2.49$\times$$10^{6}$ g/mol)의 여러 종류의 사슬 크기를 t-decalin 용액의 온도 20~7$0^{\circ}C$ 사이에서 점성도법, 레이저 광산란법을 이용하여 측정하였다. 별모양 고분자들의 팽창이 만능성을 갖기 위하여서는 그들 자신의 교란되지 않은 회전 반경 $R_{G,Br,o}$이 포함된 (N/ $R_{G,Br,o}$$^{2}$)$^{3}$2/$ au$/$\tau$$_{C}$ 파라미터가 사용될 것으로 예측하였으나, 실험 결과는 오히려 선형 폴리스타이렌 고분자의 교란되지 않은 회전 반경이 사용된 (N/ $R_{G,Br,o}$$^{2}$)$^{3}$2/$\tau$/$\tau$$_{C}$ 파라미터가 보다 우수한 만능성을 보여 주었다. 이러한 이유는 가지 효과가 $\tau$/$\tau$$_{C}$(=[(Τ-Θ$_{Tc}$ )/Θ$_{Tc}$ ]/[(Θ$_{Tc}$$_{c}$)/ $T_{c}$])부분에서 이미 반영되어 척도 상수 N/ $R_{G,O}$$^{2}$ 부분에서는 나타나지 않는 것으로 생각되어진다. 여기서 N은 고분자 사슬을 이루고 있는 단량체의 개수, Θ$_{Tc}$ 는 고분자의 분자량이 무한대일 때의 임계 용액 온도로써의 Θ 온도를 각각 의미한다.미한다.미한다.다.

Protein Patterns on a Corpus Luteum during Pregnancy in Korean Native Cows

  • Chung, Hak-Jae;You, Dong-Min;Kim, Hyo-Ju;Choi, Hye-Young;Lee, Myeong-Suk;Kim, Jin-Bum;Lee, Suck-Dong;Park, Jung-Yong;Lee, Myeung-Sik
    • Reproductive and Developmental Biology
    • /
    • 제34권3호
    • /
    • pp.263-270
    • /
    • 2010
  • Luteal cells produce progesterone that supports pregnancy. Steroidogenesis requires coordination of the anabolic and catabolic pathways of lipid metabolism. In the present study, the corpus luteum (CL) in early pregnancy established from luteal phase and pregnant phase was analyzed. The first study determined progesterone changes in the bovine CL at day 19 (early maternal recognition period) and day 90 in mid-pregnancy and compared them to the CL from day 12 of the estrous cycle. CL alternation was tested using two-dimensional polyacrylamide gel electrophoresis (2-DE) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF). Comparing CL from luteal phase to those from pregnant phase counterparts, significant changes in expression level were found in 23 proteins. Of these proteins 17 were not expressed in pregnant phase CL but expressed in luteal phase counterpart, whereas, the expression of the other 6 proteins was limited only in pregnant phase CL. Among these proteins, vimentin is considered to be involved in regulation of post-implantation development. In particular, vimentin may be used as marker for CL development during pregnancy because the expression level changed considerably in pregnant phase CL tissue compared with its luteal phase counterpart. Data from 2-DE suggest that protein expression was disorientated in mid pregnancy from luteal phase, but these changes was regulated with progression of pregnancy. These findings demonstrate CL development during mid-pregnancy from luteal phase and suggest that alternations of specific CL protein expression may be involved in maintenance of pregnancy.

VISUALIZATION AND MEASUREMENT OF A NARROW-CONE DI GASOLINE SPRAY FOR THE IMPINGEMENT ANALYSIS

  • Park, J.S.;Im, K.S.;Kim, H.S.;Lai, M.C.
    • International Journal of Automotive Technology
    • /
    • 제5권4호
    • /
    • pp.221-238
    • /
    • 2004
  • Wall interactions of direct injection spray were investigated using laser-sheet imaging, shadowgraphy, wetted footprint and phase Doppler interferometry techniques. A narrow-cone high-pressure swirl injector is used to inject iso-octane fuel onto a plate, which has three different impact angles inside a pressurized chamber. Heated air and plate conditions were compared with unheated cases. Injection interval was also varied in the heated case to compare dry- and wet- wall impingement behaviors. High-speed macroscopic Mie-scattering images showed that presence of wall and air temperature has only minor effect on the bulk spray structure and penetration speed for the narrow-cone injector tested. The overall bulk motions of the spray plume and its spatial position at a given time are basically unaffected until a few millimeters before impacting the wall. The surface properties of the impact surface, such as the temperature, the presence of a preexisting liquid film also have a small effect on the amount of wetting or the wetted footprint; however, they have strong influence on what occurs just after impact or after a film is formed. The shadowgraph in particular shows that the plate temperature has a significant effect on vapor phase propagation. Generally, 10-20% faster horizontal vapor phase propagation is observed along the wall at elevated temperature condition. For impingement onto a preexisting film, more splash and evaporation were also observed. Contrary to some preconceptions, there is no significant splashing and droplet rebounding from surfaces that are interposed in the path of the DI gasoline spray, especially for the oblique impact angle cases. There also appears to be a dense spray front consists of large sac spray droplets in the oblique impact angle cases. The bulk of the spray is not impacted on the surface, but rather is deflected by it The microscopic details as depicted by phase Doppler measurements show that the outcome of the droplet impaction events can be significantly influenced. Only droplets at the spray front have high enough Weber numbers for wall impact to wet, splash or rebound. Using the sign of vertical velocity, the time-resolved downward droplets and upward droplets are compared. The Weber number of upward moving droplets, which seldom exceeds unity, also decreases as the impact angle decreases, as the droplets tend to impact less and move along the wall in the deflected spray plume.

흉강경하 흉부교감신경절제술을 이용한 안면다한증 치료 -증례보고- (Thoracoscopic Sympathectomy for a Patient with Facial Hyperhidrosis -A case report-)

  • 문동언;박병철;김병찬;김성년
    • The Korean Journal of Pain
    • /
    • 제9권2호
    • /
    • pp.399-402
    • /
    • 1996
  • Endoscopic transthoracic sympathectomy (ETS) has recently become estabilished as a successful treatment for severe palmar and axillary hyperhidrosis. Descriptions have been published of neurolytic, operative and alternative endoscopic procedures involving thermocoagulation, laser coagulation, or or nonvideo-assisted ganglionectomy using equipment not widely available, with low morbidity and excellent results. All methods have advantage and disadvantages. A 19-year-old male who suffered from severe hyperhidrosis on face, palms and axillary areas, has been initially treated with stellate ganglion block in other pain clinic. He was transfered to our pain clinic for endoscopic thoracic sympathectomy. The patient was intubated left side 34 Fr. double lumen tube and positioned left semi-lateral position for right sympathectomy. Right side pneumothorax was created by clamping the ipsilateral side of the double lumen tube and aspiration of air. 11-mm trocar was introduced through incision at the third intercostal space in anterior axillary line, and then additional two 11-mm and 5-mm trocar was introduced through second and fifth intercostal space in mid axillary line. The lung was gently retracted and the parietal pleura over the heads of the appropriate ribs excised using 5-mm sharp insulated coagulating microprocesss. The T4, T3, and T2 ganglions, as well as accompanying rami communicantes, and other branchs arising from upper thoracic nerves to the brachial plexus and surrounding tissues were carefully dissected, coagulated. During sympathectomy, skin temperature of middle was continuously monitored. Elevation of palmar skin temperature intraoperatively indicated an adequate sympathectomy with a definite therapeutic effect. A No. 28 Fr. thoracotomy tube was introduced through a troca under video guidance, placed under water seal after the lung was reinflated. the controlateral side was performed same procedure. After bilateral sympathectomy, chest tubes were removed, and then, he was discharged 2 days after operation with great satisfaction. The ETS provides a well-tolerated, cost-effective alternative to thoracic sympathectomy for primary hyperhidrosis and sympathetic mediated neuropathic pain disorder. And T2 ganglion is considered the key ganglion for the treatment of primary hyperhidrosis. The low incidence of compensatory sweating may by explained by the limited extent of the sympathectomy.

  • PDF

펄스레이져 증착법을 이용한 Pb$ZrO_3$/Pb$TiO_3$ 산화물 인공격자의 성장 및 전기적 특성 (Growth of artificial Pb$ZrO_3$/Pb$TiO_3$ superlattices by pulsed laser deposition and their electrical properties)

  • 최택집;이광열;이재찬
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2003년도 추계학술발표강연 및 논문개요집
    • /
    • pp.54-54
    • /
    • 2003
  • 최근 새로운 개념에 물성 구현을 위한 강유전체 산화물 인공격자의 연구가 활발히 진행되고 있다. 본 연구에서는 펄스레이져 증착법을 이용하여 산소분압 100 mTorr와 증착온도 50$0^{\circ}C$에서 LSCO/MgO 기판 위에 PbTiO$_3$(PTO) 와 PbZrO$_3$(PZO)을 주기적으로 적층하여 강유전체 산화물 인공격자를 형성하였다. 인공격자의 주기는 1~100 unitcell 까지 변화시켰다. 적층주기와 두께 변화에 따른 PZO/PTO 인공격자의 성장과 전기적 특성에 대하여 관찰하였다. X선 회절분석을 통하여 PZO/PTO 인공격자는 주기가 25 unit cell 이하의 적층구조에서 초격자의 형성으로 인한 위성피크가 관찰되었으며, 그 이하의 낮은 주기(1~10 unitcell)에서는 위성피크와 강한 (100)과 (200) 성장거동을 보였다. 높은 주기에서는 c축 성장된 PTO와 a축 성장된 PZO 각각의 성장거동을 보였다. 적층 주기가 감소함에 따라 a축 성장된 PTO와 c축 성장된 PZO가 초격자를 형성하였다. 적층주기가 감소함에 따라 유전상수와 잔류분극값이 향상되었다. 유전상수는 1 unitcell 주기에서 800정도의 값을 보였고, 잔류분극값은 2 unitcell 주기에서 2Pr=38.7 $\mu$C/$\textrm{cm}^2$ 정도의 가장 큰 값을 나타냈다. 적층주기가 2 unitcell에서 두께가 감소함에 따라 유전상수가 감소하였고, 20 nm 까지 분극반전에 의한 capacitance-voltage 특성곡선의 이력 현상(강유전성)을 관찰하였다. 이러한 산화물 인공초격자에서의 유전상수와 잔류분극값의 향상에 대하여 논의 할 것이며, 임계크기효과 관점에서 나노사이즈(50 nm~5 nm)에서 인공초격자의 전기적 분극의 안정성에 대하여 또한 논의 할 것이다.소수성 가스의 경우70% 이상 향상되었음을 알 수 있었으며, 본 연구를 통해 광분해를 이용한 스크러버가 기존설비의 장.단점을 충분히 보완 가능한 환경 설비임을 확인할 수 있었다. duty로 구동하였으며, duty비 증가에 따라 pulse의 on-time을 고정하고 frequency를 변화시켰다. dc까지 duty비가 증가됨에 따라 방출전류의 양이 선형적으로 증가하였다. 전압을 일정하게 고정시키고 각 duty비에서 시간에 따라 방출전류를 측정한 결과 duty비가 높을수록 방출전류가 시간에 따라 급격히 감소하였다. 각 duty비에서 방출전류의 양이 1/2로 감소하는 시점을 에미터의 수명으로 볼 때 duty비 대 에미터 수명관계를 구해 높은 duty비에서 전계방출을 시킴으로써 실제의 구동조건인 낮은 duty비에서의 수명을 단시간에 예측할 수 있었다. 단속적으로 일어난 것으로 생각된다.리 폐 관류는 정맥주입 방법에 비해 고농도의 cisplatin 투여로 인한 다른 장기에서의 농도 증가 없이 폐 조직에 약 50배 정도의 고농도 cisplatin을 투여할 수 있었으며, 또한 분리 폐 관류 시 cisplatin에 의한 직접적 폐 독성은 발견되지 않았다이 낮았으나 통계학적 의의는 없었다[10.0%(4/40) : 8.2%(20/244), p>0.05]. 결론: 비디오흉강경술에서 재발을 낮추기 위해 수술시 폐야 전체를 관찰하여 존재하는 폐기포를 놓치지 않는 것이 중요하며, 폐기포를 확인하지 못한 경우와 이차성 자연기흉에 대해서는 흉막유착술에 더 세심한 주의가 필요하다는 것을 확인하였다. 비디오흉강경수술은 통증이 적고, 입원기간이 짧고, 사회로의 복귀가 빠르며, 고위험군에 적용할 수 있고, 무엇보다도 미용상의 이점이 크다는 면에서 자연기흉에 대해 유용한 치료방법임에는 틀림이 없으나 개흉술에 비해 재발율이 높고 비용이 비싸다는 문제가 제기되고 있는 만큼 더 세심한 주의와 장기 추적관찰이 필요하리라 사료된

  • PDF

다중 사용자 환경에서의 광 CDMA 시스템 성능 분석 (Performance Analysis of an Optical CDMA System for multi-user Environment)

  • 전상영;김영일;이주희
    • 한국통신학회논문지
    • /
    • 제24권6B호
    • /
    • pp.1134-1141
    • /
    • 1999
  • 본 논문에서는 광 코드분할 다중접속(optical code division multiple access)시스템을 구현하고 그 구현된 시스템의 성능을 분석한다. 구현된 OCDMA 시스템에서 송신단은 레이저 다이오드를 이용하여 데이터를 광 펄스로 변환하며, 4단의 지연단으로 구성한 인코더를 이용하여 펄스 열로 확산한다. 수신단에서는 인코더의 지연선 구조와 동일한 구조의 디코더에서 펄스를 지연시킨 후 결합하여 수신된 신호를 복원한다. 성능분석에 있어서는, 먼저 단일 사용자 및 다중 사용자 환경 하에서 광 CDMA 신호의 auto-correlation과 cross-correlation을 분석하고, 실험을 통해 시뮬레이션 결과를 검증하였다. 또한 광섬유 지연선의 단 수 및 코드 길이 등 시스템의 성능에 영향을 미치는 파라메타를 컴퓨터 시뮬레이션을 통해 분석하였다. 실험 결과는 인코더와 디코더의 지연선 구조가 동일한 경우 펄스 열의 중앙에서 피크값의 펄스가 발생하는 auto-correlation 특성에 의해 데이터를 복원할 수 있었고, 지연선 구조가 동일하지 않은 경우 cross-correlation 특성에 의해 데이터를 복원할 수 없었다. 성능 분석 결과는 코드 길이가 감소하거나, 지연단위의 단 수를 증 $]$쳔갭\ulcorner비트 에러 확률이 감소하지만 요구되는 레이저 광원의 펄스폭이 점차로 감소하므로 시스템 구현이 어렵게 된다. 이러한 실험 및 분석 결과를 이용하면 CDMA 기술을 광 통신 네트워크로 적용할 수 있다.

  • PDF