• Title/Summary/Keyword: Large-scale Building

Search Result 693, Processing Time 0.024 seconds

Trial Construction for the Prevention of Fire Spread in Piloti Building (필로티건축물의 화재확산방지를 위한 시범시공)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.87-88
    • /
    • 2019
  • In case of Korea, The Large-scale fire is consistently being such as 2015 Uijeongbu Fire, 2017 Jecheon Fire, 2018 Sejong Hospital Fire. Such a fire has a problem that the fire is spreading upper due to external flame spread. As a countermeasure the fire safety, the study about axial temperature prediction of external flame spread is consistently doing. But in korea, Vertical spandrel is specified as 40cm, and improvement is urgently needed. In this study, a repair material was selected to prevent the fire from spreading to a building where a flammable exterior material was installed and then pilot construction was carried out. Also, fire safety measures for buildings constructed with flammable exterior materials were examined.

  • PDF

Estimation of the Fundamental Period for Residential Buildings with Shear-Wall System

  • Chun, Young-Soo;Chang, Kug-Kwan;Lee, Li-Hyung
    • KCI Concrete Journal
    • /
    • v.12 no.1
    • /
    • pp.121-130
    • /
    • 2000
  • This study focused on evaluating the reliability of code formulas such as those of the current Korean Building Code(KBC 1988). UBC 1997, NBCC 1995. and BSLJ 1994 for estimating the fundamental period of RC apartment buildings with shear-wall dominant systems, representative of typical residential buildings in Korea. For this purpose, full-scale measurements were carried out on fifty RC apartment buildings, and these results were compared to those obtained by code formulas and also by dynamic analysis. Although these code formulas are based on the measured periods of buildings during various earthquakes and building period varies with the amplitude of structural deflection or strain level, ambient surveys should provide an effective tool for experimentally verifying the design period to the completed building. This comparison shows that comparatively large errors are likely to occure when the code formula of KBC 1988 is used, and all the other code formulas are not sufficient to estimate the fundamental period of apartment buildings with shear-wall dominant systems. An improved formula is proposed by regression analysis on the basis of the measured period data. The proposal is for the servicebility stress level, but it can also be applied for seismic code in the regions of low seismicity similar to Korea.

  • PDF

A Study on the System Improvement for Efficient Management of Large-scale Complex Disaster (대형복합재난의 효율적 관리를 위한 제도개선방안 연구)

  • Kim, Taehoon;Youn, Junhee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.176-183
    • /
    • 2018
  • Climate change, rapid urbanization, and population concentration have led to a higher frequency and magnitude of disasters in the world. Recently, the occurrence of large-scale complex disasters, which are caused by a combination of natural disasters, man-made disasters, and social disasters, is increasing. In Korea, there are many case studies of damage prediction and response technology development for individual natural disasters, such as earthquakes, floods, and typhoons. On the other hand, the system basis for the efficient response and management of large-scale complex disasters is insufficient. Therefore, this study examined the representative cases of natural, social disasters, and related cases of domestic disaster response management systems. In addition, this paper proposes ways to improve the legal system for complex disaster management policies and establish a cooperation system between the ministries for an efficient response.

Design Considerations on Large-scale Parallel Finite Element Code in Shared Memory Architecture with Multi-Core CPU (멀티코어 CPU를 갖는 공유 메모리 구조의 대규모 병렬 유한요소 코드에 대한 설계 고려 사항)

  • Cho, Jeong-Rae;Cho, Keunhee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.2
    • /
    • pp.127-135
    • /
    • 2017
  • The computing environment has changed rapidly to enable large-scale finite element models to be analyzed at the PC or workstation level, such as multi-core CPU, optimal math kernel library implementing BLAS and LAPACK, and popularization of direct sparse solvers. In this paper, the design considerations on a parallel finite element code for shared memory based multi-core CPU system are proposed; (1) the use of optimized numerical libraries, (2) the use of latest direct sparse solvers, (3) parallelism using OpenMP for computing element stiffness matrices, and (4) assembly techniques using triplets, which is a type of sparse matrix storage. In addition, the parallelization effect is examined on the time-consuming works through a large scale finite element model.

Simulated tropical cyclonic winds for low cycle fatigue loading of steel roofing

  • Henderson, David J.;Ginger, John D.;Morrison, Murray J.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • v.12 no.4
    • /
    • pp.383-400
    • /
    • 2009
  • Low rise building roofs can be subjected to large fluctuating pressures during a tropical cyclone resulting in fatigue failure of cladding. Following the damage to housing in Tropical Cyclone Tracy in Darwin, Australia, the Darwin Area Building Manual (DABM) cyclic loading test criteria, that loaded the cladding for 10000 cycles oscillating from zero to a permissible stress design pressure, and the Experimental Building Station TR440 test of 10200 load cycles which increased in steps to the permissible stress design pressure, were developed for assessing building elements susceptible to low cycle fatigue failure. Recently the 'Low-High-Low' (L-H-L) cyclic test for metal roofing was introduced into the Building Code of Australia (2007). Following advances in wind tunnel data acquisition and full-scale wind loading simulators, this paper presents a comparison of wind-induced cladding damage, from a "design" cyclone proposed by Jancauskas, et al. (1994), with current test criteria developed by Mahendran (1995). Wind tunnel data were used to generate the external and net pressure time histories on the roof of a low-rise building during the passage of the "design" cyclone. The peak pressures generated at the windward roof corner for a tributary area representative of a cladding fastener are underestimated by the Australian/New Zealand Wind Actions Standard. The "design" cyclone, with increasing and decreasing wind speeds combined with changes in wind direction, generated increasing then decreasing pressures in a manner similar to that specified in the L-H-L test. However, the L-H-L test underestimated the magnitude and number of large load cycles, but overestimated the number of cycles in the mid ranges. Cladding elements subjected to the L-H-L test showed greater fatigue damage than when experiencing a five hour "design" cyclone containing higher peak pressures. It is evident that the increased fatigue damage was due to the L-H-L test having a large number of load cycles cycling from zero load (R=0) in contrast to that produced during the cyclone.

Robust finite element model updating of a large-scale benchmark building structure

  • Matta, E.;De Stefano, A.
    • Structural Engineering and Mechanics
    • /
    • v.43 no.3
    • /
    • pp.371-394
    • /
    • 2012
  • Accurate finite element (FE) models are needed in many applications of Civil Engineering such as health monitoring, damage detection, structural control, structural evaluation and assessment. Model accuracy depends on both the model structure (the form of the equations) and the model parameters (the coefficients of the equations), and can be generally improved through that process of experimental reconciliation known as model updating. However, modelling errors, including (i) errors in the model structure and (ii) errors in parameters excluded from adjustment, may bias the solution, leading to an updated model which replicates measurements but lacks physical meaning. In this paper, an application of ambient-vibration-based model updating to a large-scale benchmark prototype of a building structure is reported in which both types of error are met. The error in the model structure, originating from unmodelled secondary structural elements unexpectedly working as resonant appendages, is faced through a reduction of the experimental modal model. The error in the model parameters, due to the inevitable constraints imposed on parameters to avoid ill-conditioning and under-determinacy, is faced through a multi-model parameterization approach consisting in the generation and solution of a multitude of models, each characterized by a different set of updating parameters. Results show that modelling errors may significantly impair updating even in the case of seemingly simple systems and that multi-model reasoning, supported by physical insight, may effectively improve the accuracy and robustness of calibration.

Experimental study of structural behavior of 80MPa concrete outrigger member using post tension method (PT공법을 적용한 80MPa급 콘크리트 아웃리거부재의 실험적 연구)

  • Choi, Jong-Moon;Kim, Woo-Jae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.31-34
    • /
    • 2009
  • Large outrigger elements tie the concrete core to perimeter columns, significantly increasing the building's lateral stiffness as well as its resistance to overturning due to wind. The outriggers are deep elements, and large tie forces are resisted by top and bottom heavy longitudinal reinforcing and vertical ties. To reduce construction costs, all primary reinforcing bars in outrigger levels are SD500. Further, concrete strengths of 80MPa have been specified for outrigger elements. However, the reductions in the amount of concrete and reinforcement steel are more increased in tall building. With these backgrounds, 80MPa high strength concrete outrigger system using post tension method is developed. Significant economic savings can be made by reducing the element sizes and material content. The developed outrigger system is designed using strut-and-tie models. In addition, four 1/4-scale test specimens were selected from the same prototype structure. The results from the tests are confirmed that the structural behaviors of the developed outrigger member have better capacities than those of a conventional method.

  • PDF

A Study on The development status and future of Photovoltaic Urban Project (태양광발전 도시 프로젝트의 개발현황과 발전방향 고찰)

  • Kim, Hyun-Il;Suh, Seung-Jik;Park, Kyung-Eun;Kang, Gi-Hwan;Yu, Gwon-Jong
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.87-92
    • /
    • 2008
  • Buildings are responsible for approximately 50% of current carbon dioxide emissions. Energy planning at a town and city scale needs a strategic approach, supported by strong planning policies. The purpose of this study was to investigate the urban scale grid-connected photovoltaic(PV) system for urban residential and commercial sector applications. The integration of PV technology into roof of houses is an approach that is being championed in Germany, Japan and United states etc. In the Korea, PV roofing systems already are given the large number of houses which are projected to be built by 2012. However unlike germany and Japan, urban scale grid-connected PV system is not yet installed. The solar city which is installed building-integrated photovoltaic system is available to use of renewable energy sources such as solar to meet demand, instead of fossil fuels, with the goal of realizing an ecologically oriented energy supply.

A Study on the Suitability of Characteristics for Planning of Exterior Pedestrian Spaces in Large-scale Apartment Complexes (대규모 아파트단지 외부보행공간의 계획특성에 관한 적합성 평가 연구)

  • Kwon, So-Young;Ha, Mi-Kyoung
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.27-36
    • /
    • 2009
  • Lately construction companies are differentiating the outdoor spaces of apartment complexes to satisfy the needs of residents by providing underground parking area and variety of outdoor community spaces. Building walking networks through residential unit area, the major passage area and the entrance area of the complexes is very important factor to increase the use of the outdoor environment in the complexes. The purpose of this study is to evaluate the characteristics and the elements for the planning of exterior pedestrian spaces carefully through the analysis of current large-scale apartment complexes. In this study, the utilization of space, the connectivity to other spaces and the application of Universal design were evaluated through site visits in 5 large-scale apartment complexes. As a result, the utilization of space is well applied in the most of complexes especially in residential unit area. The connectivity to other spaces has low application compared to the others. Universal design is also well applied except sub criteria for the blind in most of complexes. This study will be able to help in providing better exterior pedestrian environment for residents in apartment complexes.

Design of SCADA System for a Large-Scale Offshore Wind Farm (대규모 해상풍력발전단지 운용을 위한 SCADA 시스템 설계)

  • Kim, Dong Wook;Song, Jae Ju;Jung, Nam Joon;Choi, Hyo Yul
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.3
    • /
    • pp.161-170
    • /
    • 2012
  • In recent years, many researchers and developers have been interested in renewable energy all over the world. Particularly, the development of wind power is being processed actively due to its high economic efficiency. A few years ago, Korean government has started the research for building a large-scale offshore wind farm in domestic west-southern area. Current domestic SCADA technology level for operating wind farm is very low compared with foreign SCADA technology level. In this paper, we found IT issues and solutions for developing SCADA system. Based on these solutions, we designed SCADA system for a large-scale offshore wind farm.