• Title/Summary/Keyword: Large-Scale Fire Experiments

Search Result 16, Processing Time 0.032 seconds

The combustion test of assuming in parking space for fire resistance (지하주차장의 내화성능 평가를 위한 차량연소실험)

  • Kang, Seung Goo;Kim, Dong Jun;Lee, Jae Young;Harada, Kazunori;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.48-50
    • /
    • 2013
  • In this study, Car fire for test using ISO 9705 10MW Large Scale Calorimeter. Especially, study on the underground parking for the fire resistance performance. The underground parking lot of the fire resistance regulations in according to with the standard heating curve in Korea. Because of this burning car through experiments to the propose a new heating curve.

  • PDF

Development Plan for the Consequence Management in Response to Large-Scale Wildfire Disasters Using Air Force Transport Aircraft (C-130) (공군 수송기(C-130)를 활용한 대형산불 재난 대응 시 사후관리(CM) 발전방안)

  • Sangduk Kim;Minki Kim
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.232-243
    • /
    • 2024
  • Purpose: Recently, large-scale forest fires caused by climate change, natural disasters, and human factors have been increasing every year in the East Coast and Taebaek Mountains region. Although forest fire extinguishing using helicopters is currently increasing, the need to introduce air force transport aircraft has continued to be raised due to the importance of early fire extinguishment to respond to large forest fires and the difficulty of extinguishing forest fires between sheep. This study seeks to present a plan for developing a post-fire management system for several aspects - achieving operational objectives, overcoming the operating environment, selecting a staging area, and efficient operation measures - to efficiently perform forest fire extinguishing missions using Air Force transport aircraft. Method: Based on literature research on forest fire extinguishing, forest fire extinguishing experiments using fixed-wing aircraft, and the operation status and operation method of forest fire extinguishing helicopters, the pros and cons of helicopter operation and the effects of large forest fire extinguishing using a large transport aircraft (C-130) Analyze the effectiveness of operation through analysis. Results: When extinguishing a large forest fire, an effective CM (Consequence Management) application plan was derived, including effective operation, control, command system, dispatch request, and forest fire extinguishment when integrating helicopter and fixed-wing aircraft (C-130). Conclusion: The application of the concept of CM (Consequence Management) is partially applied to some areas of chemical, biological, and radiological (CBRNE) protection in Korea, but efficient operation, control, and command systems are established when integrated operation of helicopters and large aircraft (C-130) in forest fire extinguishment. the concept of CM (Consequence Management), which is operated in advanced countries, was applied for safety management, dispatch requests, and forest fire extinguishing, thereby contributing to the establishment of a more advanced disaster and post-disaster management system.

Cracks evolution and multifractal of acoustic emission energy during coal loading

  • Kong, Xiangguo;Wang, Enyuan;He, Xueqiu;Liu, Xiaofei;Li, Dexing;Liu, Quanlin
    • Geomechanics and Engineering
    • /
    • v.14 no.2
    • /
    • pp.107-113
    • /
    • 2018
  • Coal samples with different joints morphology were subjected to uniaxial compression experiments, cracks evolution was recorded by Nikon D5300 and acoustic emission (AE) energy signals were collected by AEwin Test for Express-8.0. During loading process, coal samples deformed elastically with no obvious cracks changes, then they expanded gradually along the trace of the original cracks, accompanied by the formation of secondary cracks, and eventually produced a large-scale fracture. It was more interesting that the failure mode of samples were all shear shape, whatever the original cracks morphology was. With cracks and damage evolution, AE energy radiated regularly. At the early loading stage, micro damage and small scale fracture events only induced a few AE events with less energy, while large scale fracture leaded to a number of AE events with more energy at the later stage. Based on the multifractal theory, the multifractal spectrum could explain AE energy signals frequency responses and the causes of AE events with load. Multifractal spectrum width (${\Delta}{\alpha}$), could reflect the differences between the large and small AE energy signals. And another parameter (${\Delta}f$) could reflect the relationship between the frequency of the least and greatest signals in the AE energy time series. This research is helpful for us to understand cracks evolution and AE energy signals causes.

A Review and Analysis of the Thermal Exposure in Large Compartment Fire Experiments

  • Gupta, Vinny;Hidalgo, Juan P.;Lange, David;Cowlard, Adam;Abecassis-Empis, Cecilia;Torero, Jose L.
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.345-364
    • /
    • 2021
  • Developments in the understanding of fire behaviour for large open-plan spaces typical of tall buildings have been greatly outpaced by the rate at which these buildings are being constructed and their characteristics changed. Numerous high-profile fire-induced failures have highlighted the inadequacy of existing tools and standards for fire engineering when applied to highly-optimised modern tall buildings. With the continued increase in height and complexity of tall buildings, the risk to the occupants from fire-induced structural collapse increases, thus understanding the performance of complex structural systems under fire exposure is imperative. Therefore, an accurate representation of the design fire for open-plan compartments is required for the purposes of design. This will allow for knowledge-driven, quantifiable factors of safety to be used in the design of highly optimised modern tall buildings. In this paper, we review the state-of-the-art experimental research on large open-plan compartment fires from the past three decades. We have assimilated results collected from 37 large-scale compartment fire experiments of the open-plan type conducted from 1993 to 2019, covering a range of compartment and fuel characteristics. Spatial and temporal distributions of the heat fluxes imposed on compartment ceilings are estimated from the data. The complexity of the compartment fire dynamics is highlighted by the large differences in the data collected, which currently complicates the development of engineering tools based on physical models. Despite the large variability, this analysis shows that the orders of magnitude of the thermal exposure are defined by the ratio of flame spread and burnout front velocities (VS / VBO), which enables the grouping of open-plan compartment fires into three distinct modes of fire spread. Each mode is found to exhibit a characteristic order of magnitude and temporal distribution of thermal exposure. The results show that the magnitude of the thermal exposure for each mode are not consistent with existing performance-based design models, nevertheless, our analysis offers a new pathway for defining thermal exposure from realistic fire scenarios in large open-plan compartments.

Performance of Adhesives in Glulam after Short Term Fire Exposure

  • Quiquero, Hailey;Chorlton, Bronwyn;Gales, John
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.299-311
    • /
    • 2018
  • As engineered timber such as Glulam is seeing increasing use in tall timber buildings, building codes are adapting to allow for this. In order for this material to be used confidently and safely in one of these applications, there is a need to understand the effects that fire can have on an engineered timber structural member. The post-fire resilience aspect of glulam is studied herein. Two sets of experiments are performed to consider the validity of zero strength guidance with respect to short duration fire exposure on thin glulam members. Small scale samples were heated in a cone calorimeter to different fire severities. These samples illustrated significant strength loss but high variability despite controlled quantification of char layers. Large scale samples were heated locally using a controlled fuel fire in shear and moment locations along the length of the beam respectively. Additionally, reduced cross section samples were created by mechanically carving a way an area of cross section equal to the area lost to char on the heated beams. All of the samples were then loaded to failure in four-point (laterally restrained) bending tests. The beams that have been burnt in the shear region were observed as having a reduction in strength of up to 34.5% from the control beams. These test samples displayed relatively little variability, apart from beams that displayed material defects. The suite of testing indicated that zero strength guidance may be under conservative and may require increasing from 7 mm up to as much as 23 mm.

Thermal Insulation Properties of Sandwich Panel Core with EPS Bead and Glass Wool (EPS Bead와 유리섬유를 혼입한 샌드위치 패널 심재의 단열 특성)

  • Jeon, Eun-Yeong;Lee, Chang-Woo;Hwang, Woo-Jun;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.77-78
    • /
    • 2022
  • To improve the fire vulnerability of the organic insulation sandwich panel core, which is the main culprit of the large-scale fire disaster, an experiment was conducted to examine the thermal conductivity properties of the core material mixed with the organic insulation material EPS Bead and the inorganic insulation material glass wool. As the Additional ratio of glass wool increased, the thermal conductivity decreased, and it was determined that the replacement of glass wool of 3% or more had little effect on the decrease in thermal conductivity. In addition, it can be seen that the most ideal thermal conductivity is exhibited when 1% Replacement ratio of EPS and 3% glass wool are added. The core material of such organic and inorganic insulation materials is judged to be a core material that can compensate for the fire vulnerability of existing insulation materials. Therefore, in order to determine whether it is used as a core material for sandwich panels, additional studies such as fire resistance experiments and sound absorption experiments are needed in the future.

  • PDF

A Study on Combustion Experiments of Multi Type Air-Conditioner Outdoor Units by Large Scale Calorimeter (라지스케일 칼로리미터에 의한 멀티시스템형 에어컨실외기의 연소실험에 관한 연구)

  • Min, Se-Hong;Bae, Yeon-Jun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.168-177
    • /
    • 2011
  • The combustion test for real box of AC outdoor unit has been performed in this study in order to estimate the fire hazard in multi-system type of AC outdoor unit which is currently used for commercial use. The result showed that in test, there was explosion inside of AC outdoor unit, and flame erupted and fire spread through upper side grill. And then this fire burnt the combustibles such as wires, electronic control board, heat exchange copper plate and plastics etc inside the unit, refrigerant gas pipe was burst due to fire, and accelerated the explosion and flame eruption to outside while the refrigerant was erupting. It is found in this test that the maximum heat release rate of AC outdoor unit is 5,830 kW, the maximum internal temperature measured with infrared camera and thermocouple is $1,201^{\circ}C$, maximum ambient temperature is $881^{\circ}C$, and flame rose higher than about 5 m. It is concluded that the fire in AC outdoor unit cause fire to combustibles around the unit, and may give big damage by generating the secondary fire. It is expected that the result obtained from the test on the real object may be applied to fire realization of AC outdoor unit and estimation of fire spreading to the combustibles around in the future computer simulation.

THERMAL AND SMOKE MEASUREMENTS OF VEHICLE FIRES Establishing practical large-scale experiment for vehicle fires

  • Kim, Jeong-Hun;Kim, Hong;Lee, Bog-Young;Lee, Chang-Seop
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.335-342
    • /
    • 1997
  • Experiments were conducted to evaluate the hazard risks of vehicle fires. Sensors were strategically placed in passenger cars to determine the temperature, propagation rate and direction of flame. The life safety hazard evaluations such as smoke and gas analysis were included. An important ignition position was performed in the engine compartment. The effects of different ignition positions and the opening of door glasses were also reviewed. The experimental results indicate that the maximum temperature when a vehicle burns varies commonly from 90$0^{\circ}C$ -100$0^{\circ}C$. The flame reaches in the face of a driver about 6-7minutes and the windshield glass breaks about 10 minutes after the ignition in the engine compartment of vehicle. And the smoke and gas concentrations reached the limit of human inhalation after 13-14 minutes. Especially the concentrations of carbon monoxide exceeded the TWA(50 ppm) during short time after ignition in cases of all experiments.

  • PDF

Comparative Analysis of YOLOv8 Object Detection Model Performance in Fire Detection in Traditional Markets Using Thermal Cameras (열화상 카메라를 이용한 전통시장 화재 감지에서 YOLOv8 객체 탐지 모델의 성능 비교 분석)

  • Ko Ara;Cho Jungwon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.19 no.4
    • /
    • pp.117-126
    • /
    • 2023
  • Traditional markets, formed naturally, often feature aged buildings and facilities that are susceptible to fire. However, the lack of adequate fire detection systems in these markets can easily lead to large-scale fires upon ignition. Therefore, this study was conducted with the aim of detecting fires in traditional markets, utilizing thermal imaging cameras for data collection and the YOLOv8 model for object detection experiments. Data were collected in the night markets within traditional markets of xx city and by simulating fire scenarios. A comparative analysis of the Nano and XL models of YOLOv8 revealed that the XL model is more effective in detecting fires. The XL model not only demonstrated higher accuracy in correctly identifying flames but also tended to miss fewer fires compared to the Nano model. In the case of objects other than flames, the XL model showed superior performance over the Nano model. Taking all these factors into account, it is anticipated that with further data collection and improvement in model performance, a suitable fire detection system for traditional markets can be developed.

Autoencoder Based Fire Detection Model Using Multi-Sensor Data (다중 센서 데이터를 활용한 오토인코더 기반 화재감지 모델)

  • Taeseong Kim;Hyo-Rin Choi;Young-Seon Jeong
    • Smart Media Journal
    • /
    • v.13 no.4
    • /
    • pp.23-32
    • /
    • 2024
  • Large-scale fires and their consequential damages are becoming increasingly common, but confidence in fire detection systems is waning. Recently, widely-used chemical fire detectors frequently generate lots of false alarms, while video-based deep learning fire detection is hampered by its time-consuming and expensive nature. To tackle these issues, this study proposes a fire detection model utilizing an autoencoder approach. The objective is to minimize false alarms while achieving swift and precise fire detection. The proposed model, employing an autoencoder methodology, can exclusively learn from normal data without the need for fire-related data, thus enhancing its adaptability to diverse environments. By amalgamating data from five distinct sensors, it facilitates rapid and accurate fire detection. Through experiments with various hyperparameter combinations, the proposed model demonstrated that out of 14 scenarios, only one encountered false alarm issues. Experimental results underscore its potential to curtail fire-related losses and bolster the reliability of fire detection systems.