• Title/Summary/Keyword: Large dynamic range

Search Result 286, Processing Time 0.027 seconds

A Dynamic Variational-Asymptotic Procedure for Isotropic Plates Analysis (등방성 판의 동적 변분-점근적 해석)

  • Lee, Su-Bin;Lee, Chang-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.72-79
    • /
    • 2021
  • The present paper aims to set forth a two-dimensional theory for the dynamics of plates that is valid over a large range of excitation. To construct a dynamic plate theory within the long-wavelength approximation, two dimensional-reduction procedures must be used for analyzing the low- and high-frequency behaviors under the dynamic variational-asymptotic method. Moreover, a separate and logically independent step for the short-wavelength regime is introduced into the present approach to avoid violation of the positive definiteness of the derived energy functional and to facilitate qualitative description of the three-dimensional dispersion curve in the short-wavelength regime. Two examples are presented to demonstrate the capabilities and accuracy of all of the formulas derived herein by using various dispersion curves through comparison with the three-dimensional finite element method.

Frequency range expansion of pneumatic exciter by using dual-chamber (이중챔버를 이용한 공압 가진기의 주파수 범위 확장)

  • Park, Young-woo;Kim, Kwang-joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.815-824
    • /
    • 2013
  • Pneumatic exciters can be good replacements of electrodynamic, piezoelectric and hydraulic exciters owing to simple structure and large exciting force. One problem to be solved is a slow response caused by compressibility of air. Desirable frequency response characteristics of exciter are constant magnitude and zero degree phase, because users want no time delay between input signal and output force. For this reason, frequency range of pneumatic exciters is limited about 0~1 Hz. Therefore, expansion of frequency range is an important issue when designing the pneumatic exciter. In this paper, the pneumatic exciter which has same structure with active pneumatic isolator is dealt with. The dynamic characteristics are presented, and its limitation of expanding frequency range is shown based on analytical studies. Then the pneumatic exciter with dual-chamber is suggested to overcome this problem. Based on simulation study, a design method is presented.

  • PDF

Size Verification of Small and Large Bubbles in a Bubble Column (기포탑에서 작은기포와 큰기포의 크기 구별)

  • Seo, Myung Jae;Jin, Hae-Ryong;Lim, Dae Ho;Lim, Ho;Kang, Yong;Jun, Ki-Won
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.304-309
    • /
    • 2012
  • Size verification of small and large bubbles in a bubble column was investigated by employing the dynamic gas disengagement (DGD) method and dual electrical resistivity probe (DRP) method, simultancously. The holdups of large and small bubbles in the bubble column in a given operating condition were obtained by means of the DGD method by measuring the pressure drop variation in the column with a variation of time after stopping the gas input into the column. The size and frequency of bubbles were measured by the DRP method in the same operating condition, from which the bubble holdup of each range of size was obtained. The verification of size in determining the large or small bubbles was decided by comparing the holdups of large or small bubbles measured by the DGD method with that measured by the DRP method. Filtered compressed air and tap water were used as a gas and a continuous liquid medium. The diameter and height of the bubble column were 0.102 m and 1.5 m, respectively. The demarcation size between the large and the small bubbles in the bubble column was 4.0~5.0 mm; the demarcation size was about 5.0 mm when the gas velocity was in the relatively low range, but about 4.0 mm when the gas velocity was in the relatively high range, within this experimental conditions.

Dual Stage Servo Controller for Image Tracking System (듀얼 스테이지 서보 시스템을 이용한 영상 추적장치의 안정화 제어)

  • Choi Y.J.;Kang M.S.;Ryu K.H.;Lee S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.45-46
    • /
    • 2006
  • In this paper, a dual stage servo mechanism has been developed for image tracking system to improve transient control performances such as small rise time, small overshoot, small settling time, etc. A secondary stage, a platform, actuated by a pair of electro-magnets is mounted on a conventional elevation gimbal. In this mechanism, the gimbal provides large range but slow motion and the platform provides small range but fast positioning. A sliding mode control is applied to the platform positioning to attain robust performances and stability in the presence of the disturbance related to dynamic coupling of the gimbal and the platform. Results from experiments illustrate that the suggested dual stage mechanism controlled by the sliding mode control is effective in improving transient responses and attenuating the disturbance related with dynamic coupling.

  • PDF

Effects of traffic-induced vibrations on bridge-mounted overhead sign structures

  • Kim, Janghwan;Kang, Jun Won;Jung, Hieyoung;Pack, Seung-woo
    • Structural Engineering and Mechanics
    • /
    • v.55 no.2
    • /
    • pp.365-377
    • /
    • 2015
  • Large-amplitude vibration of overhead sign structures can cause unfavorable psychological responses in motorists, interfere with readability of the signs, and lead to fatigue cracking in the sign structures. Field experience in Texas suggests that an overhead sign structure can vibrate excessively when supported within the span of a highway bridge instead of at a bent. This study used finite element modeling to analyze the dynamic displacement response of three hypothetical sign structures subjected to truck-passage-induced vertical oscillations recorded for the girders from four actual bridges. The modeled sign bridge structures included several span lengths based on standard design practices in Texas and were mounted on precast concrete I-girder bridges. Results revealed that resonance with bridge girder vertical vibrations can amplify the dynamic displacement of sign structures, and a specific range of frequency ratios subject to undesirable amplification was identified. Based on these findings, it is suggested that this type of sign structure be located at a bridge bent if its vertical motion frequency is within the identified range of bridge structure excitation frequencies. Several alternatives are investigated for cases where this is not possible, including increasing sign structure stiffness, reducing sign mass, and installing mechanical dampers.

A study of SMOS line driver with large output swing (넓은 출력 범위를 갖는 CMOS line driver에 관한 연구)

  • 임태수;최태섭;사공석진
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.5
    • /
    • pp.94-103
    • /
    • 1997
  • It is necesary that analog buffer circuit should drive an external load in the VLSI design such as switched capacitor efilter (SCF), D/A converter, A/d converter, telecommunicatin circuit, etc. The conventional CMOS buffer circuit have many probvlems according as CMOS technique. Firstly, Capacity of large load ar enot able to opeate well. The problem can be solve to use class AB stages. But large load are operated a difficult, because an element of existing CMOS has a quadratic functional relation with inptu and outut voltage versus output current. Secondly, whole circuit of dynamic rang edecrease, because a range of inpt and output voltages go down according as increasing of intergration rate drop supply voltage. In this paper suggests that new differential CMOS line driver make out of operating an external of large load. In telecommunication's chip case transmission line could be a load. It is necessary that a load operate line driver. The proposal circuit is planned to hav ea high generation power rnage of voltage with preservin linearity. And circuit of capability is inspected through simulation program (HSPICE).

  • PDF

A Study on the Rail Pone of Transition Curve Track to Speed Up of Tilting train (틸팅차량 완화곡선 증속 주행시 궤도작용력 검토)

  • Shin, Tae-Hyoung;Choi, Jung-Youl;Eum, Ki-Young;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.529-538
    • /
    • 2009
  • A trial run of locally-developed tilting train has been in process on Chungbuk line since the test vehicle was first produced. For the system stabilization, interface verification among the systems including track, structure, catenary and signaling system, not to mention the rolling stock, is very crucial. Therefore, in this study, the dynamic rail force of the tilting (Hanvit 200), high-speed (KTX) and general (Mugunghwa) vehicle caused by driving in transition curve track was measured. And, it compared the tilting response with the other by using the measured wheel load data in transition curve track, and then evaluated probability the range of wheel load fluctuation for the variable dynamic vertical and lateral wheel load. As a result, a range of wheel load by occured a change of cant from the high-speed and general vehicle which had fixed bogie structure was distributed throughout small deviation (${\Delta}8{\sim}13kN$). Otherwise, in case of the tilting train which was consisted of the pendulum bogie structure was distributed wide range about large deviation (${\Delta}25{\sim}28kN$) by changed of cant.

  • PDF

Control of nonlinear production-distribution process with limited decision policy (최대구매 제한을 갖는 비선형 생산분배계의 제어)

  • 정상화;정상표;오용훈
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.3
    • /
    • pp.156-165
    • /
    • 1997
  • In the practical control systems, the dynamic range of actuatiors is limited(or saturated) when actuators are driven by sufficiently large signals. This gives rise to a nonlinearity as a result of actuator saturation. For example, the upper limit is imposed on productive capability by available factory space and capital equipment. Other examples of those kinds of actuator saturations are a maximum torque of the actua- ting motors and a throttle position in an aircraft speed control A saturating actuator may lead not only to a large overshoot during start-up and shut-down, but also to deterioration of the performance due to the uncertainties. That is, the speed of response is decreased and, possibly, the system output may not follow the lalrge reference inputs. The large-overshoot may be accompanied by rest wind-up(or called by integra- tor wind-up) which comes from controllers with integral action in saturation operation regions. Eventually, as the overshoot increases, the system has a limit cycle or becomes oscillatorily unstable. Due to these cir- cumstances, many studies are focused on the stability and robustness of the nonlinear systems with satu- rating actuator in the time-domain as well as in the frequency-domain.

  • PDF

Effects of Interaction Range on the Behavior of Opinion Consensus

  • Lee, Seungjae;Cho, Young Sul;Hong, Hyunsuk
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1406-1409
    • /
    • 2018
  • We have frequently encountered the rapid changes that prevalent opinion of the social community is toppled by a new and opposite opinion against the pre-exiting one. To understand this interesting process, mean-field model with infinite-interaction range has been mostly considered in previous studies S. A. Marvel et al., Phys. Rev. Lett. 110, 118702 (2012). However, the mean-field interaction range is lack of reality in the sense that any individual cannot interact with all of the others in the community. Based on it, in the present work, we consider a simple model of opinion consensus so-called basic model on the low-dimensional lattices (d = 1, 2) with finite interaction range. The model consists of four types of subpopulations with different opinions: A, B, AB, and the zealot of A denoted by $A_c$, following the basic model shown in the work by S. A. Marvel et al.. Comparing with their work, we consider the finite range of the interaction, and particularly reconstruct the lattice structure by adding new links when the two individuals have the distance < ${\sigma}$. We explore how the interaction range ${\sigma}$ affects the opinion consensus process on the reconstructed lattice structure. We find that the critical fraction of population for $A_c$ required for the opinion consensus on A shows different behaviors in the small and large interaction ranges. Especially, the critical fraction for $A_c$ increases with the size of ${\sigma}$ in the region of small interaction range, which is counter-intuitive: When the interaction range is increased, not only the number of nodes affected by $A_c$ but also that affected by B grows, which is believed to cause the increasing behavior of the critical fraction for $A_c$. We also present the difference of dynamic process to the opinion consensus between the regions of small and large interaction ranges.

Out-of-Band Measurement of LED-based Solar Blind UV Filters

  • Cui, Muhan;Zhou, Yue;Chen, Xue;Yan, Feng;Zhang, Mingchao;Yang, Huaijiang
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.244-250
    • /
    • 2014
  • Due to the difficulty in measuring very low out-of-band cutoff depths of solar blind UV filters, we propose a cutoff depth adjustable measurement system (CDAM) to test deep cutoff filters with a large dynamic range. The CDAM utilizing the substitution method is elaborately composed of several parts, including narrow-band LED light sources, standard reflective neutral attenuators with known attenuation coefficients, and a photomultiplier (PMT). This paper also presents an attenuator combination method ensuring that the PMT works within its linear response range. In addition, numerical simulation testifies to the method, and experiment shows that the CDAM system can achieve an extension of dynamic range from 0-6 OD to 0-10 OD, which is sufficient for the measurement of out-of-band cutoff depths of solar blind UV filters. Above all, the CDAM system, being easily implemented, of wide dynamic range, and highly precise, could be widely used in the measurement of filter cutoff depth.