• 제목/요약/키워드: Large Transformer

검색결과 335건 처리시간 0.019초

변형된 SOM을 이용한 유입변압기 열화진단 (Diagnosis of Power Transformer Using Modified Self Organizing Map)

  • 이종필;지평식;임재윤;김성수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.578-580
    • /
    • 2004
  • Substation facilities have become large and complex in the electric power systems. Development of condition monitoring and diagnosis techniques have been very important to improve the security of substation transformers. This paper presents a method to analyze the cause and the degree of aging of power transformers by Self organizing map(SOM). Dissolved gas data were non-linearly transformed by sigmoid function to make determination of SOM close to that of human. Potential of a failure and the degree of aging of a normal transformer are identified by using the proposed quantitative criterion. Furthermore, transformer aging is monitored by the proposed criterion for a set of transformers. To demonstrate the validity of the proposed method, a case study is performed and its results are presented.

  • PDF

변압기 보호용 수정 전류차동 계전방식 (A Modified Current Differential Relay for Transformer Protection)

  • 강용철;김은수;원성호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권2호
    • /
    • pp.80-86
    • /
    • 2004
  • During magnetic inrush or over-excitation, saturation of the core in a transformer draws a large exciting current, which can cause mal-operation of a differential relay. This paper proposes a modified current differential relay for transformer protection. The relay calculates core-loss current from the induced voltage and the core-loss resistance; the relay calculates the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss and the magnetizing currents from the conventional differential current. Comparison study with the conventional differential relay with harmonic blocking is also shown. The proposed technique not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the speed of the conventional relay.

AR 모델 및 LSQ 기반 변류기 2차 전류 복원 기법 (AR Model and LSQ Based Compensation Method for the Saturated Secondary Current of a Current Transformer)

  • 장수영;이동규;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권6호
    • /
    • pp.221-226
    • /
    • 2006
  • The current flowing though a power line is measured by a current transformer (CT). Since a CT is a kind of transformer, saturation of magnetic flux in the core may occur when a large primary current flows. This saturation makes the secondary current of a CT distorted and causes problems in the protection point of view. Because of the current distortion, a protection relay cannot collect the correct information showing how the primary power system changed. Consequently, the current distortion may cause the mal-operation or operation time delay of protective relay. In this paper, an algorithm based on AR model and LSQ is proposed to compensate the saturated CT secondary currents. Various test results indicate that the proposed algorithm can accurately compensate a severely distorted secondary current and is not affected by remanence.

무접점 베터리 충전 장치용 Half-Bridge 직렬 공진 컨버터 분석 및 설계 (Analysis and Design of Half-Bridge Series Resonant Converter for Non-Contact Battery Charger)

  • 김창균;유정식;박종후;조보형;서동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2508-2511
    • /
    • 1999
  • A non-contact battery charger which transfers energy using magnetic field without any electrical contacts is designed using half-bridge series resonant converter. This converter utilizes series resonance to reduce the undesirable effect of large leakage inductance of the non-contact transformer and ZVS operation can reduce switching losses. In this paper. analysis and design procedure of half-bridge series resonant converter with non-contact transformer is presented. Input voltage is 85VAC ${\sim}$ 270VAC, output voltage and current is 4.1V and 800mA, respectively. Furthermore, a method for calculating the secondary current of the transformer to control battery charging current in constant current charging mode which is required for litium-ion battery is proposed and the performance is verified from experiments.

  • PDF

Islanding Prevention Method for Photovoltaic System by Harmonic Injection Synchronized with Exciting Current Harmonics of Pole Transformer

  • Yoshida, Yoshiaki;Fujiwara, Koji;Ishihara, Yoshiyuki;Suzuki, Hirokazu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권3호
    • /
    • pp.331-338
    • /
    • 2014
  • When large penetration of the distributed generators (DGs) such as photovoltaic (PV) systems is growing up in grid system, it is important to quickly prevent islanding caused by power system fault to ensure electrical safety. We propose a novel active method for islanding prevention by harmonic injection synchronized with the exciting current harmonics of the pole transformer to avoid mutual interference between active signals. We confirm the validity of the proposed method by performing the basic tests of islanding by using a current source superimposed the harmonic active signal. Further, we carry out the simulation using PSCAD/EMTDC, and verify the fast islanding detection.

UPFC 이상변압기 모델을 사용한 유연송전장치 일차민감도 해석 (First-Order Sensitivities for FACTS Devices using UPFC Ideal Transformer Model)

  • Thomas W. Gedra;Seung-Won An
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.837-846
    • /
    • 2004
  • This paper presents a screening technique for greatly reducing the computation involved in determining the optimal location and types of Flexible AC Transmission System (FACTS) devices in a large power system. The first-order sensitivities of the generation cost for various FACTS devices are derived. This technique requires solving only one optimal power flow (OPF) to obtain sensitivities with respect to FACTS device control variables for every transmission line To implement a sensitivity-based screening technique, we used a new UPFC model, which consists of an ideal transformer with a complex turns ratio and a variable shunt admittance. A S-bus system based on the IEEE 14-bus system was used to illustrate the technique.

A New Parallel Hybrid Filter Configuration Minimizing Active Filter Size

  • Park, Sukin;Sung, Jeong-hyoun;Nam, Kwanghee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.894-897
    • /
    • 1998
  • A conventional parallel hybrid active filter has an inherent problem of large current ratings of devices used in inverter. In general, this problem has been solved by adjusting turn ratio of a matching transformer. However, making the transformer with high turn ratio may be not available for high power system due to its requirement for high voltage insulation. In this paper, a new configuration is proposed for parallel hybrid active filter. In the proposed hybrid active filter, the active filter is connected to the passive filter inductor in parallel through a matching transformer for the aim of reducing the size of inverter. Through computer simulations, we have shown the outstanding performances of the proposed topology.

  • PDF

사파이어 실리콘 결정 성장용 80kW 10kA PWM 컨버터 시스템 개발 (Development of PWM Converter System for Sapphire Silicon Ingot Glowing of 80kW 10kA)

  • 김민회;박영식
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.33-41
    • /
    • 2014
  • This paper is research result for a development of sapphire silicon ingot glowing(SSIG) PWM converter system for 80kW 10kA. The system include 3-phase AC-DC diode rectifier of input voltage AC 380V and 60Hz, DC-AC single phase full bridge PWM inverter of high frequency, AC-DC single-phase full wave rectifier using center-tapped of transformer for low voltage 8.0V and large current 10,000A of output specification, tungsten resistor load 0.1[$m{\Omega}$]. PWM switching frequency for IGBT inverter control set 30kHz. The suggested researching contents are designed data sheets of power converter system, PSIM simulation, operating characteristics and analysis results of developed SSIG system. This paper propose

진동신호 분석을 위한 On-Line 시스템 개발 (Developement of On-Line System for Vibration Signal Analysis)

  • 김언석;임성정;김영식;이영길;김재철;정찬수;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.616-619
    • /
    • 1995
  • This paper describes developement of on-line system for vibration signal analysis. In the power system, the main reason of transformer fault is due to a large amount of current by a short-circuit and a ground-fault. The electromagnetic force caused by fault-current deforms transformer windings and results in vibration pattern change. Therefore if the continuous on-line vibration monitoring on transformer is performed, an incipient failure can be detected. The developed system is composed of data acquisition devices, user interface program, signal processing program, diagnosis and trend analysis program, self diagnosis program and communication program.

  • PDF

전력용 변압기에서 권선방식과 벡터그룹에 따른 보호계전기 동작원리의 그래픽 표현 (Graphical Presentation on Operational Principle of Pretective Relay According to Winding Type and Vector Group in Transformer)

  • 이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.226-233
    • /
    • 1999
  • Protective relay for transformer operates in general by comparing with the differential current and the restraint current. These kinds of currents are changed on magnitude and phasor during the fault according to winding type and vector group. This paper presents the differential and restraint currents and operational principle of differential protective relay for two-winding and three-winding transformer with graphical mode. It is developed using MATLAB for and educational purpose on engineer related in power system and protection in university and power utility including large factory.

  • PDF