• Title/Summary/Keyword: Lamps

Search Result 1,057, Processing Time 0.075 seconds

Position Estimation Using Neural Network for Navigation of Wheeled Mobile Robot (WMR) in a Corridor

  • Choi, Kyung-Jin;Lee, Young-Hyun;Park, Chong-Kug
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1259-1263
    • /
    • 2004
  • This paper describes position estimation algorithm using neural network for the navigation of the vision-based wheeled mobile robot (WMR) in a corridor with taking ceiling lamps as landmark. From images of a corridor the lamp's line on the ceiling in corridor has a specific slope to the lateral position of the WMR. The vanishing point produced by the lamp's line also has a specific position to the orientation of WMR. The ceiling lamps have a limited size and shape like a circle in image. Simple image processing algorithms are used to extract lamps from the corridor image. Then the lamp's line and vanishing point's position are defined and calculated at known position of WMR in a corridor. To estimate the lateral position and orientation of WMR from an image, the relationship between the position of WMR and the features of ceiling lamps have to be defined. But it is hard because of nonlinearity. Therefore, data set between position of WMR and features of lamps are configured. Neural network are composed and learned with data set. Back propagation algorithm(BPN) is used for learning. And it is applied in navigation of WMR in a corridor.

  • PDF

A Research on the Actual Conditions of the Electric Shock Hazard of a Guard Lamp (보안등의 감전 위험성에 관한 실태조사)

  • Jang, Tae-Jun;Jung, Yeon-Ha;Roh, Young-Su;Kwak, Hee-Ro;Choi, Chung-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.32-38
    • /
    • 2005
  • In this paper, guard lamps at three areas have been investigated to understand the actual conditions of the electric shock hazard of the guard lamps. Upon the basis of the obtained data, the actual conditions of the guard lamps were precisely analyzed in terms of the electric shock hazard. As a result of the investigation, it was turned out that many guard lamps were not installed in organized ways due to the lack of legal regulations, resulting in the increase of electric shock hazard. Therefore, it is necessary, from a point of electric shock protection view, to establish the regulations of equipment installation and management, which can be specifically applied to guard lamps.

A Study on Accelerated Life Test of Halogen Lamps for Medical Device (의료용 할로겐램프의 가속수명시험에 관한 연구)

  • Jung, Jae Han;Kim, Myung Soo;Lim, Heonsang;Kim, Yong Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.41 no.4
    • /
    • pp.659-672
    • /
    • 2013
  • Purpose: The purpose of this study was to estimate life time of halogen lamps and acceleration factors using accelerated life test. Methods: Voltage was selected as an accelerating variable through the technical review about failure mechanism. The test was performed at 14.5V, 15.5V and 16.5 for 4,471 hours. It was assumed that the lifetime of Halogen lamps follow Weibull distribution and the inverse power life-stress relationship models. Results: Mean lifetimes of pin and screw types were 19,477 hours and 6,056 hours, respectively. In addition, acceleration factor of two items are calculated as 4.8 and 2.2 based on 15.5V, respectively. Conclusion: The life-stress relationship, acceleration factor, and MTTF at design condition are estimated by analyzing the accelerated life test data. These results suggest that voltage was very important factor to accelerate life time in the case of halogen lamps and the life time of pin type is three times longer than screw type lamps.

Electrical Characteristics Analysis of LED Lamps using Internal Converter for Road and Street Lighting (컨버터 내장형 LED 가로등 및 보안등의 전기적 특성 분석)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.238-244
    • /
    • 2010
  • In this paper, we studied electrical characteristics of internal converter type of LED lamps for road and street lighting. We surveyed electro-technical regulations and KS(Korean industrial standards) about LED luminairs. Waveforms of voltage and current, thermal distributions, insulation resistances between live parts and exposed conductive parts, and flame test of cover of LED lamps were experimented and analyzed. In regulations, insulation resistance between live conductors and exposed conductive parts should be greater than $0.2M{\Omega}$ in case nominal voltage of wiring is 220V. In KS codes, the value of insulation resistance should be greater than $2M{\Omega}$ while applying DC 500V or DC 100V. In the result of this study, waveforms of primary voltage and current were distorted. There was difference in waveforms of secondary voltage and current according to composition of converter. Mostly, insulation resistances were measured high more than regulation and code value but some measured points were measured badly($0.0M{\Omega}$). Cover of LED lamps was ignited easily. We expect that the results of this study would be helpful for revision of regulations and national codes for the electrical safety of LED road and street lighting.

A Study on the Emergency and Recovery AC/DC Combination Lamps in the Electric Substations (변전소의 AC/DC 겸용 비상 및 복구 등에 관한 연구)

  • Park, Joon-Yeol;An, Youn-Ki;Kim, Jong-Soo;Shin, Hye-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.27-34
    • /
    • 2010
  • This study is for the improvement in the equipment environment of the emergency and recovery lamps in electric substations. To solve problem about the weak illuminance of existing emergency lamps, the AC/DC combination lamps and switches are reviewed. And the improved illuminance standards that are divided each room's purpose are suggested. It is based on a nuclear power plant's Illuminance Standards and a safety lamp's Illuminance Standards of Illuminance Standards Korean Industrial Standards - KS A 3011 -, not just 5~10[%] in according with normal lamp's illuminance. Lastly, The experiments are conducted to prove the suggested contents on this study. Consequently, a battery capacity is not increased, but illuminance of emergency and recovery lamps can be increased.

The New Thick-Film Hybrid Converters For Halogen and Fluorescent Lamps

  • Gondek, J.;Dzialek, K.;Kocol, J.;Kawa, B.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.2
    • /
    • pp.43-48
    • /
    • 2001
  • Economical consumption of energy, longer life of lamps, higher lighting comfort and new aesthetic of illumination is subject of numerous research and development works. The halogen lamps are an example of positive solution some of above mentioned problems. The electronic transformers are more frequent used for their supply. In comparison with conventional transformers they have less weight, less volume and 60% less power losses. Their advantages are particular visible, when the hybrid technique is applied. The paper presents the results of engineering research and development works carried out in Private Institute of Electronic Engineering, in R. & D. Center for Hybrid Microelectronics and Resistors and in Technical School of Communications in Krakow, in the field of the design and exploitation tests of hybrid converters 220V AC /12V DC (electronic transformers) and electronic ballasts destined for the supply of halogen lamps 20W to 150W and fluorescent lamps respectively. To perform the converters, thick film technology and surface mount technology were used. For the protection of converter electronic circuit the thick film temperature sensor and transistors were applied. Moreover the paper presents the base application circuits of elaborated converters, their technical parameters and exploitation results. The development perspectives of such domain of hybrid circuits are also discussed.

  • PDF

Effects of Security Lighting Lamps on Discomfort Glare to Indoor Occupants

  • Lee, Yoon Jeong;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: Although security lights are used to secure pedestrian visibility and safety at nighttime, they can generate light trespass in the neighboring residential space. To prevent this, standards for acceptance limits on vertical illuminance and light pollution by the windows of residential buildings are presented. Method: This study thus representatively selected three types of lamps and, through an evaluation and analysis of the physical and subjective discomfort glare per lamp, proposed a discomfort glare index for each lamp. The evaluation and analysis according to the lamps were conducted through experiments. The variables were the security lights' lamps (NH 100W, MH 70W, LED 50W), installation angles ($0^{\circ}$, $20^{\circ}$), and installation distances (3m, 5m, 7m, 9m). Result: According to the results of the discomfort glare evaluation depending on the angles and distances of the security lights, the following minimum standards are proposed: for NH 100W, a discomfort glare index of 30 and an installation distance of 4m; for MH 70W, a discomfort glare index of 32 and an installation distance of 4m; and, for LED 50W, a discomfort glare index of 31 and an installation distance of 6m, respectively. In addition, this paper recommends the use of MH 70W, when the road width is 4m-6m, and LED 50W, when the road width is over 6m, respectively.

Fast Lamp Pairing-based Vehicle Detection Robust to Atypical and Turn Signal Lamps at Night

  • Jeong, Kyeong Min;Song, Byung Cheol
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.4
    • /
    • pp.269-275
    • /
    • 2017
  • Automatic vehicle detection is a very important function for autonomous vehicles. Conventional vehicle detection approaches are based on visible-light images obtained from cameras mounted on a vehicle in the daytime. However, unlike daytime, a visible-light image is generally dark at night, and the contrast is low, which makes it difficult to recognize a vehicle. As a feature point that can be used even in the low light conditions of nighttime, the rear lamp is virtually unique. However, conventional rear lamp-based detection methods seldom cope with atypical lamps, such as LED lamps, or flashing turn signals. In this paper, we detect atypical lamps by blurring the lamp area with a low pass filter (LPF) to make out the lamp shape. We also propose to detect flickering of the turn signal lamp in a manner such that the lamp area is vertically projected, and the maximum difference of two paired lamps is examined. Experimental results show that the proposed algorithm has a higher F-measure value of 0.24 than the conventional lamp pairing-based detection methods, on average. In addition, the proposed algorithm shows a fast processing time of 6.4 ms per frame, which verifies real-time performance of the proposed algorithm.

Statistical analysis of social factors and lighting physical quantities to present CPTED guideline (CPTED 기준 제시를 위한 사회적 요인과 조명물리량의 통계 분석)

  • Kim, Kwang Hoon;Oh, Jin Woo;Hwang, Jun Kwon;Jeon, Soo Joeng;Yoon, Geun Young
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.17-22
    • /
    • 2019
  • In recent years, crime has been steadily increasing, causing not only economic damage but also aggravating the social atmosphere. The CPTED(Crime Prevention Through Environmental Design) guideline, which is an environmental crime prevention design technique, reduces the possibility of crime by implementing a proper defensive design plan through appropriate lighting design in the city and reduces the fear of crime. Among the various principles of CPTED, the proper use of street lamps and CCTV is considered to be an important factor in enabling natural surveillance. In this study, the authors identified and quantified the current status of the installation of street lamps and CCTV in each autonomous district of Seoul. The physical quantity of lighting and social factor quantified from light lamps and CCTV data, respectively, were expected to support the guidelines presented by CPTED. Therefore, we conducted statistical analysis based on quantified values and found that street lamps and CCTV had a statistically significant relationship with crime rate. In addition, the correlation between the safety index and the crime rate, calculated by dividing the number of street lamps and CCTVs by area, was also analyzed and an R2 value of 0.647 was confirmed.

THE NEW THICK-FILM HYBRID CONVERTERS FOR HALOGEN AND FLUORESCENT LAMPS

  • Gondek, J.;Dzialek, K.;Kocol, J.;Kawa, B.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.04a
    • /
    • pp.57-65
    • /
    • 2001
  • Economical consumption of energy, longer life of lamps, higher lighting comfort and new aesthetic of illumination is subject of numerous research and development works. The halogen lamps are an example of positive solution some of above mentioned problems. The electronic transformers are more frequent used for their supply. In comparison with conventional transformers they have less weight, less volume and 60% less power tosses. Their advantages are particular visible, when the hybrid technique is applied. The paper presents the results of engineering research and development works carried out ill Private Institute of Electronic Engineering, in R. & D. Center for Hybrid Microelectronics and Resistors and in Technical School of Communications in Krakow, in the field of the design and exploitation tests of hybrid converters 220V AC /12V DC (electronic transformers) and electronic ballasts destined for the supply of halogen lamps 20W to 150W and fluorescent lamps respectively. To perform the converters, thick film technology and surface mount technology were used. For the protection of converter electronic circuit the thick film temperature sensor and transistors were applied. Moreover the paper presents the base application circuits of elaborated converters, their technical parameters and exploitation results. The development perspectives of hybrid domain of hybrid circuits are also discussed.

  • PDF