• Title/Summary/Keyword: Lamp type

검색결과 424건 처리시간 0.028초

대향형 Xe 플라즈마 평판 램프의 방전 및 발광 특성에 관한 수치적 연구 (Numerical Analysis of the Discharge and Luminous Characteristics of a Planar Type Xe Plasma Flat Lamp)

  • 김혁환;이원종
    • 한국전기전자재료학회논문지
    • /
    • 제24권10호
    • /
    • pp.822-833
    • /
    • 2011
  • A Xe plasma flat lamp, which has been noticed as a new eco-friendly LCD (liquid crystal display) backlight, requires the improvement of the luminance and the luminous efficiency although it has several advantages. To improve the performance of a lamp, it is necessary to understand the effects of discharge variables on the luminous characteristics of the lamp. Since it is difficult to diagnose a lamp discharge experimentally, the numerical analysis can be used instead. In this study, the luminous characteristics of a planar type Xe plasma flat lamp were analyzed with the variation of an input voltage and a pulse frequency. The numerical analysis of a lamp discharge was then performed using a RCT (relaxation continuum) model and a LFA (local field approximation) model. The comparison with the experimental results showed that the RCT model is valid for the numerical analysis of the flat lamp. The numerical analysis also showed that the modifications of a high frequency component and a voltage falling rate in the input voltage waveform could improve the luminous characteristics of the lamp.

High quality tubular field emission lamp using a wire type carbon-nano-structure emitter (CNX)

  • Hiraki, Hirohisa;Harazono, Hideki;Onozawa, Takuya;Nakamoto, Masayuki;Hiraki, Akio
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1591-1593
    • /
    • 2008
  • The tubular field emission lamp (FEL) was developed using a wire type carbon-nano-structure emitter called CNX The luminous efficiency of the tubular FEL (diode type, diameter: ${\varphi}15.5mm$, length: 200mm) has already achieved around 45lm/W and we expect to achieve over 60lm/W within the year.

  • PDF

자동차 LED Head Lamp의 방열을 위한 Heat Sink의 수치해석적 연구 (A Study on the Numerical Analysis of Heat Sink for Radiant Heat of Automotive LED Head Lamp)

  • 최병희;김창오
    • 한국산학기술학회논문지
    • /
    • 제13권10호
    • /
    • pp.4398-4404
    • /
    • 2012
  • 본 논문은 자동차 LED head lamp의 방열을 위한 히트싱크(heat sink)의 설계요소를 변화시켜 방열특성을 알아보고자 수치해석을 수행하였다. 수치해석에 적용한 히트싱크는 LED를 광원으로 사용하는 기존제품(Type 1)을 바탕으로 한정된 내부공간에 적합하도록 설계하여 5가지 Type으로 설계하였다. 설계된 히트싱크의 수치해석은 ANSYS CFD V12.1을 사용하여 히트싱크의 변화에 따른 온도분포와 평균온도, 공기유동특성, 열유속 등을 분석하였다. 수치해석을 통하여 방열판의 구조와 휜 형상에 따른 방열특성의 상관관계를 도출할 수 있었으며, 설계된 히트싱크의 온도분포, 공기의 유동특성, 열유속 등을 분석한 결과, 히트싱크 Type 2가 다른 Type들에 비해 LED head lamp의 방열을 위해 적합한 특성을 나타내었다.

밤재배원에서 유살등 구조 및 램프의 종류가 해충 유인력에 미치는 영향 (Effects of Light Trap Structure and Lamp Type on the Attraction of Chestnut Pests in an Orchard)

  • 김영재;김현경;김길하
    • 한국응용곤충학회지
    • /
    • 제53권3호
    • /
    • pp.217-223
    • /
    • 2014
  • 밤재배원에서 램프광선을 이용한 방제기기(A, B, C형)를 개발하여 램프의 종류에 따라 유인된 곤충의 포획력을 조사하였다. A형 기기에서 수은 램프를 이용하여 포획된 곤충은 125종이었고, 이 중 밤나무 해충은 23종만을 종 동정하였다. B형과 C형의 기기에 컴팩트형광 램프를 부착하여 포획성능을 검정한 결과 B형기기에서는 딱정벌레류(83%), C형 기기에서는 나비류(73%)의 유인효과가 높은 것으로 나타났다. B형 기기를 이용한 밤바구미의 성충에 대한 램프의 유인 포획력을 조사한 결과에서는 수은투명 램프(평균 9.8마리)에서 유인포획 효과가 가장 높았다. C형 기기를 이용한 복숭아명나방의 성충에 대한 유인 포획력을 조사한 결과에서는 컴팩트형광 램프(평균 10.2마리)를 이용한 기기에서 포획수가 가장 많았다.

3자유도 조명로봇 설계 및 구현 (Design and Implementation of a 3 DOF Robotic Lamp)

  • 이윤석;서종태;김희국;이병주
    • 로봇학회논문지
    • /
    • 제5권3호
    • /
    • pp.216-223
    • /
    • 2010
  • Most lamp units at ceilings, walls, and streets are static and no automatic motion capabilities are available at all to adjust lamp tilting angles and its zooming position. This paper proposes a new robotic lamp that creates three degrees of freedom (DOF) motion by using a spherical-type parallel mechanism with a unique forward kinematic position. In the robotic lamp, three motors are placed at the base frame to control two tilting angles and one zoom in-and-out motion for a localized light. The kinematic model of this device is derived and the proto type has been developed. The performance of this device was verified through experiment.

Lamp 형 오존발생기에 관한 연구 (A Study on the Lamp Type Ozonizer)

  • 강천수;송현직;김상구;박원주;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1995년도 추계학술발표회논문집
    • /
    • pp.25-28
    • /
    • 1995
  • This paper describes ozone concenteration(O3con) and ozone generation(O3g) of lamp type ozo-nizer(O-Lamp)which be performed a role of lighting source and ozonizer. O=Lamp is consist of two low pressure mercury lamps. The important conclus-ions obtained from this paper are as follows, The more quality of supplied gas(Q) decrease, the higher O3con rise, The more quality of supplied gas(Q) increase, the higher O3g some rise. The Escherichia coli is reacted on ozone can be sterilized above 99[%]. Also, O-Lamp can confirmed possibility of appli-cation as lighting-source.

  • PDF

0.25 mm 초박형 두께를 가지는 회로기판형 리드프레임 백색 LED 램프 (Super Thin 0.25 mm Thickness White LED Lamp with PCB Type Lead Frame)

  • 유순재;김도형
    • 한국전기전자재료학회논문지
    • /
    • 제23권1호
    • /
    • pp.34-37
    • /
    • 2010
  • 0.25 mm thickness super thin surface mounted device LED Lamp is developed with PCB type lead frame in which BT (Bismaleimide Triazine) resin is used. BT resin is removed by a laser beam in order to reduce the thermal resistance below $1\;^{\circ}C/W$ and transfer molding is used with silicone. Compared to conventional 0.4 mm thickness LED lamp, the developed LED lamp can be derived in high current and the luminance of the LED lamp is increased up to 240 mA.

조명용 LED 램프의 사용 시간에 따른 연색지수 특성변화 (Aging-Time Dependence of Color Rendering Index of a LED Lamp for Lighting)

  • 손민우;이덕희;서정철
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.1-6
    • /
    • 2014
  • We measured color rendering index(CRI) of a LED lamp for lighting for aging-time. We chose bulb type white LED lamp six samples and halogen lamp one sample and applied 220V, 60Hz to all the samples for 1,000hours at ordinary temperature. The CRI was measured every 20hours and the CRI change of the LED lamp was compared with the halogen lamp's CRI change. As time goes, efficiency of the halogen lamp decreased and the CRI maintained uniformly. The other hand, efficiency of the LED lamp decreased but the CRI increased. The CRI of the LED lamp has been stabilized since 600hours. The CRI change of the LED lamp was analyzed with a spectrum, color coordinate and color temperature.

휴대용 방폭형 작업등의 경량화 연구 (Development of a Light Weight Hand Lamp of Explosion-Proof Type)

  • 최상원;이관형;김명섭;임의수
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1997년도 추계 학술논문발표회 논문집
    • /
    • pp.135-142
    • /
    • 1997
  • For lighting of dark and hazardous workplaces such as compartments of ships under construction, workers should use hand lamps of explosion-proof type. However, the heavy weight of such lamps has prevented most impatient workers from using such types of lamps extensively. In this paper, ire developed a light weight hand lamp of intrinsic safety type which reduced the weight a lot while maintaining or improving the lighting and explosion-proof function. We made a Prototype which consisted of lamp fixture and low/high frequency power supply. Testing results show that the hand lamp meets well all the explosion-proof testing requirements of the Korea Industrial Safety Corporation.

  • PDF

24″평판형광램프에 관한 전기적광학적특성연구 (The Research of Electrical and Optical Properties for 24″ Flat Panel-Florescent Lamp)

  • 김수용;박승곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.527-530
    • /
    • 2001
  • In this paper, the basic characteristics of flat fluorescent lamp using ultraviolet generate from gas discharge and powder type electrolyminescent display(P-ELD) using a phenomenon of the light emission eaused by the electrical field applied to phosphor are studied. The lamp is a simple structure with insulator layer, phosphor layer, and gas gap. Current(displacement current + discharge current) in flat fluorescent lamp using.

  • PDF