• Title/Summary/Keyword: Lamp type

Search Result 424, Processing Time 0.027 seconds

Plasma Diagnosis of Ne:Xe, Ne:Ar Mixed Gases by Single Langmuir Probe in Inductively Coupled Plasma Light Source System (ICP 광원 시스템의 Ne:Xe, Ne:Ar 혼합가스의 단일탐침법을 이용한 플라즈마 진단)

  • Choi, Yong-Sung;Lee, Woo-Ki;Moon, Jong-Dae;Lee, Kyung-Sup;Lee, Sang-Heon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.91-95
    • /
    • 2006
  • In whole world consciousness of environment maintenance have increased very quickly for the end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mechanism is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by Langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe.

  • PDF

The Electron temperature and Density properties of Mixing gas in ICP Lighting system(Ne:Xe, Ne:Ar) (ICP 광원 시스템의 Ne:Xe Ne:Ar 혼합가스의 전자온도 및 전자밀도의 특성 연구)

  • Choi, Gi-Seung;Lee, Jonh-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2424-2426
    • /
    • 2005
  • In whole world consciousness of environment maintenance have increased very quickly for he end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe and Ne:Ar mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe and Ne:Ar plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe and Ne:Ar.

  • PDF

Characteristic improvement of the forward type high voltage pulse power supply for Lamp Type Ozonizer (램프형 오존발생기용 Foward형 고압 펄스전원장치의 특성개선)

  • Kim, Kyung-Sik;Won, Jae-Sun;Kim, Dong-Hee;Ro, Chae-Gyun;Nam, Seung-Sik;Sim, Kwang-Yeal
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1117-1119
    • /
    • 2001
  • This paper describes the forward type pulse power supply using a Power-MOSFET in the view of commercialization. The principle of basic operating and the operating characteristics of the forward type pulse power supply are estimated by the switching frequency, coupling factor and duty ratio. It is shown that theoretical and experimental results are in good agreement by comparing simulation and experimental results when a lamp type ozonizer can be used as a load. Also, experimental results indicate that the discharge and ozone concentration characteristics of the manufactured pulse power supply is more improved compare to the conventional pulse power supply[5]. This proposed supply show that it can be practically used as a pulse power supply in various environment improvement facilities.

  • PDF

Simulation of undewater irradiance distribution in coastal squid jigging vessel using the LED and metal halide fishing lamp combination (LED와 메탈헬라이드 집어등을 겸용한 연안 오징어채낚기 어선의 수중 방사조도 분포 시뮬레이션)

  • Bae, Jae-Hyun;An, Heui-Chun;Kim, Mi-Kyung;Park, Hae-Hun;Jung, Mee-Suk
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.4
    • /
    • pp.511-519
    • /
    • 2014
  • This study is aimed to analyze the three-dimensional underwater irradiance using an optical simulation software and to clarify the propriety and operation method under considering luminous intensity distribution of the luring lamp and penetrability in the seawater, when we use the light diffuser type 300W high powered LED and the metal halide lamp (MHL) on a coastal squid jigging vessel in the 10-ton class, simultaneously. For their attenuation characteristics of each wavelength in relation to the sea, LED lamp was to be effective in the 1.9-fold at 50 m depth and 2.1-fold at 80 m for underwater irradiance more than MHL according to the power consumption. In addition, the underwater irradiance distribution using the LED and MHL combination was rather increased even when reducing total power usage up to 20% depending on the simulation with changing the configuration and lighting angle of the lamp. These results can be utilized as an evaluation method of the operation and performance of the LED lamp according to adjusting its arrangement and lighting angle.

Electronic Ballast Design for Ceramic MHL by using Its Conductance Model (세라믹 MHL의 컨덕턴스 모델을 이용한 전자식 안정기 설계)

  • Park, Chong-Yeon;Shin, Dong-Seok
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.117-122
    • /
    • 2008
  • This paper presents the conductance model at high frequency of the Ceramic Metal Halide Lamp and the designing method of the electronic ballast with the LCC resonant tank type by using that model. Conductance model is based on a physical phenomenon in the discharge tube of the lamp and model constants of conductance model are obtained by Least Squares Method. After equivalent impedances are determined by the conductance model, The LCC resonance tank is designed by using the equation of the lamp power. Simulation result using PSpice software and experimental results show that the conductance model in this paper is very useful to design the electronic ballast at high frequency for the Ceramic Metal Halide Lamps.

  • PDF

Study on Spectrum Properties by Frequency in Xe DBD lamp (제논 DBD 광원의 주파수에 따른 스펙트럼 특성 연구)

  • Pack, Gwang-Hyeon;Choi, Young-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.122-124
    • /
    • 2005
  • The flat panel lamp is used as back light. It is perceived the best type for the wide size LCD of back light system. However, the flat panel lamp has high value of heat. So it need to improve efficiency. Therefore, more researches are requested for the back light of the flat panel lamp. In this paper, the properties of spectrum is investigated according to change in frequency from 30kHz to 60kHz using power supplies voltage with changing from 500V to 700V. As a result, main spectrum peak of plasma showed in 450[nm], 630[nm], 750[nm] and spectrum peak of 750nm is the highest.

  • PDF

A study on reducing the harmonics in inverter system for fluorescent lamp (형광등용 인버터 시스템의 고조파 저감에 관한 연구)

  • Park, Chan-Kun;Kim, Jong-Yun;Jeon, Nae-Suck;Park, Jeung-Hwan;Lee, Sung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1199-1201
    • /
    • 2000
  • This paper proposes a harmonics reducing circuit for fluorescent lamp inverters using hybrid type smoothing circuit with pumping and smoothing capacitors. A waveform of full-wave rectification used as a direct current power supply at fluorescent lamp inverters contains a lot of harmonic wave from inrush current which is generated near the maximum of input voltage with purse shape when voltage smoothing capacitor is charged. Therefore, in order to suppress inrush current which will result in harmonic wave. this paper proposes a method to control abrupt charging current by use of charging voltage at pumping capacitor. The suppression of harmonics generation at lamp current is confirmed through simulations.

  • PDF

High Frequency Modulation Electronic Ballast for The Metal Halide Lamp (메탈 할라이드 램프용 고주파 변조 방식 전자식 안정기)

  • Moon Tae Hwan;Oh Duk Jin;Cho Kyu Min;Kim Hee Jun
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.589-593
    • /
    • 2001
  • This paper presents a high frequency modulation electronic ballast for the metal halide lamp. As the proposed ballast operates in high frequency ranges (20kHz - 100kHz) and it can start up the lamp using the LC resonant circuit without external igniter, the proposed ballast is very compact. The proposed ballast is controlled with the modulated frequency in the range of 20kHz to 100kHz, and it has variable modulating frequencies between 200Hz and 2kHz in order to avoid the acoustic resonance phenomenon. In this paper, a new realtime acoustic resonance detection method is described and the experimental results with the proto-type ballast of 150W metal halide lamp with the dimming function are discussed.

  • PDF

Electrical and Optical properties of Xe EEFL by mixed gas (Xe EEFL의 혼합가스에 따른 전기 광학적 특성)

  • Kim, Nam-Goon;Lee, Seong-Jin;Yang, Jong-Kyung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1568-1569
    • /
    • 2007
  • TFT-LCD used in display area is not a light-emissive device itself but TFT-LCD can overcome through the employ of the backlight unit (BLU). BLU is very important device in TFT-LCD system. However, the old-fashion BLU of CCFL type is crucible to the health due to the contained material, mercury (Hg). Moreover, strong temperature dependency of lamp employed with Hg becomes the other disadvantage in practical usage. To solve these problems, Hg-Free lamp with strong thermal resistance property is required to displace the Hg lamp. We studied optical and electrical properties of Xe-Ne-He mixed gas that is dependent on change of mixed ratio and pressure. In our results, the designed lamp without the phosphorescent material has the lowest firing voltage at xe 50%(Ne:He=9:1).

  • PDF

A Study on the Development of a pub level Silica Measuring Technology by the Split-beam Type System (스플리트빔 형태의 고정도 단위 실리카 측정기술 개발에 관한 연구)

  • 정경열;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.382-388
    • /
    • 2002
  • Dissolved silica is one of fatal components at a boiler facility Therefore, a dissolved silica measurement system should be equipped for managing efficiently the boiler facility. Most of silica measurement systems are composed of a sensor module of single-beam type structure, and silica density is measured with a infrared spectrometry using the Lambert-beer method. However, such a system occurs measuring error of large range and inconsistency of a light source, because of measuring a standard sample and a measuring sample alternatively. This paper introduces a method that the sensor module has a split-beam type structure and a tungsten lamp. The proposed system can measure silica density quickly and precisely more than those composing of a single-beam type structure, because of measuring and comparing with two samples at a same time. And examination results are shown to compare efficiencies of the system and existing commercial products, and for an ammonia influence.