• 제목/요약/키워드: Lamp

검색결과 2,685건 처리시간 0.032초

고효율 신광원 시스템의 특성에 관한 연구 (A Study of High Efficiency Electrodeless lamp Properties)

  • 김현숙;이세현;신상욱;임종민;허성국;황명근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1717-1720
    • /
    • 2002
  • Electrodeless discharge lamps have been objects of interest and research for several decades, mainly because of their potential for extremely long life, high lamp efficacies and smaller than standard fluorescent lamps size. A series of measurements and observations concerning variables has yielded optical and electrical characteristics for electrodeless discharge lamp like incandescent lamp and circular lamp feature. Last experiment were carried out to determine the lamp temperature at several surface points during operation. Light output levels in excess over 60,000 cd/$m^2$ have been measured in electrodeless discharge lamp for a general of conditions. At lamp surface temperatures have been measured over $80^{\circ}C$, and starting current have been measured over ${\sim}A$.

  • PDF

메탈 할라이드 램프 외관의 최적 봉착조건에 관한 연구 (A Study for Optimal filling Condition in Outer Enclosure of Metal Halide Lamp)

  • 지철근;이성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.296-299
    • /
    • 1987
  • The purpose of this paper is to increase the lamp efficacy by filling the optimal Nitrogen gas pressure in the outer enclosure of metal halide lamp. This study presents a new model of Langmuir in the outer enclosure of discharge lamp. In this paper, in the first place, the diameter of Langmuir sheath and the total gab loss were calculated. Secondly, the each gas loss was computed if the arbitrary gas pressure is filled, With the calculated data, flash over which affects the lamp efficacy, lamp life and color rendering was considered. In case of the established discharge lamp, the gab pressure has been filled by experience only roughly. The gas loss is converted into the radiation output. Therefore, the lamp efficacy is improved by reducing the gas loss.

  • PDF

고압 나트륨램프의 점등과 소등을 위한 제어기의 릴레이 접점의 융착 방지 (The Prevention of Melting Contact in Accordance Relay of Controller for Turn on/off High Pressure Sodium Vapor Lamp)

  • 한태환;우천희
    • 전기학회논문지P
    • /
    • 제53권3호
    • /
    • pp.148-151
    • /
    • 2004
  • For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in electric discharge tube, So accelerative electron collide against vapor atom and second electron is generated, And rapidly the current flow to electric discharge tube. This starting voltage is high voltage and source for melting contact that relay is according as turn on/off high pressure sodium vapor lamp. Consequently, This paper propose that the prevention of melting contact in accordance relay of controller for turn on/off high pressure sodium vapor lamp.

분유에 오염된 Cronobacter sakazakii 검출을 위한 중합효소연쇄반응, 실시간중합효소연쇄반응, 등온검출법의 비교 (Comparison of Polymerase Chain Reaction, Real-time Polymerase Chain Reaction, and Loop-Mediated Isothermal Amplification for the Detection of Cronobacter sakazakii in Milk Powder)

  • 김영주;서승우;왕효우;서동주;이민화;손나리;이복희;최창순
    • 한국축산식품학회지
    • /
    • 제33권5호
    • /
    • pp.610-616
    • /
    • 2013
  • 본 연구에서는 영유아에게 치명적인 감염을 일으키는 C. sakazakii에 대하여 LAMP 검출법을 개발하였다. LAMP법에 의한 C. sakazakii의 검출율은 100%였으며 13개의 음성 지표군에 대해서는 모두 음성 반응을 보여 특이도가 매우 높은 것으로 판단되었다. 또한, HhaI과 NruI 두 개의 제한 효소를 LAMP product에 반응시킨 결과, 유전자의 특정 염기서열이 절단되는 것을 확인하였으며, 이를 통해 LAMP 검출법에 의해 증폭된 DNA가 C. sakazakii-specific ompA임을 확인하였다. 조제분유에 오염 된 C. sakazakii를 LAMP법으로 검출 시 검출한계는 $10^0$ CFU/mL이었으며 이는 기존의 PCR법이나 real-time PCR법에 비해 100-10,000배 높은 수준으로 민감도가 매우 높은 것으로 판단되었다. 이와 같이 높은 특이도와 민감도를 가진 LAMP 검출법은 C. sakazakii와 같은 급성 기회 감염균이나 병원성 미생물에 의한 식중독 발생시 현장에서 병원체를 간편하고 신속하게 검출할 수 있는 기술로 기대된다.

백열등의 광력에 따른 수중 투과특성 (Transmittance Characteristics by candlepower of Incandescent Lamp)

  • 박성욱;배봉성;안희춘;이정우;서두옥
    • 수산해양기술연구
    • /
    • 제38권4호
    • /
    • pp.293-299
    • /
    • 2002
  • 초망어업에 있어서 멸치군을 집어하기 위한 집어등의 광량을 구명하기 위한 기초연구로서 1 ㎾ 와 2 ㎾ 백열등의 방사조도 특성을 계측하였으며, 그 결과를 요약하면 다음과 같다. 1. 백열등의 수중방사조도는 파장 690 nm에서 최대치를 보였고, 2가지 백열등의 수중 방사조도 L(W/$\textrm{cm}^2$/nm)와 섬도 Z(m)와의 관계식은, 1 ㎾ : L = 3851.9 $e^{-1.4587Z}$ $R^2$=0.9952 2 ㎾ : L= 8211.9 $e^{-1.2852Z}$ $R^2$=0.9977이었다. 2. 2 ㎾ 백열등의 수중 방사조도는 섬도 4m 층보다 얕은 수층에서는 1 ㎾ 백열등보다 3~4배 높게 나타났지만 심도 6m보다 깊은 수층부터는 동일한 밝기를 나타내었다. 3. 1 ㎾ 백열등의 빛은 정횡방향보다 연직방향쪽으로 많이 투과되었으며, 집어등의 연직방향에 있어서 심도 20m층의 수중방사조도는 0.1 l$\chi$이었다.

UVB조사기의 홍반 발생 특성과 안전성에 관한 연구 (The Study of Characteristic of Induced Erythema and Safety by UVB Lamp)

  • 박래준;조용호;박소현;이윤미
    • The Journal of Korean Physical Therapy
    • /
    • 제18권3호
    • /
    • pp.79-87
    • /
    • 2006
  • Purpose: The present study purposed to examine induced characteristic or erythema and safety by medium wave ultra violet(UVB) lamp. Methods: We compared sunshine and UVB lamp using spectroradiometer and UV radiometer. For measuring sunshine irradiation, we used spectoradiometer and detected from 8 to 18 o'clock every each hour on the beach, playground and rooftop of a 5 story building. The subjects for erythema examination were 5 healthy subjects who have no pathologic history of photosensitivity reaction, psoriasis and vitiligo. They were exposed to UVB radiation at the abdominal area for 2 hours and after irradiation, we observed the change of skin color every 12 hours over a period of 1 week. Results: Between sunshine and UVB lamp, sunshine had higher data on the chromaticity coordinates, dominant and peak wavelength, bandwidth and purity than the UVB lamp but on the color temperature, brightness the UVB lamp had higher data than the sunshine. In comparison of sunshine and UVB lamp, UVB lamp irradiated constantly such as $3.9-4.4{\mu}W/cm^2$ at a distance of 100cm between bed and lamp which was same as early morning irradiation on the sunshine. The erythema didn't appear to any subject. Conclusion: This results suggest that the UVB lamp has lower irradiance as much as early sunshine. Therefore the UVB lamp had no influence of inducing erythema at a distance of 100cm between bed and lamp.

  • PDF

Development of an Improved Loop-Mediated Isothermal Amplification Assay for On-Site Diagnosis of Fire Blight in Apple and Pear

  • Shin, Doo-San;Heo, Gwang-Il;Son, Soo-Hyeong;Oh, Chang-Sik;Lee, Young-Kee;Cha, Jae-Soon
    • The Plant Pathology Journal
    • /
    • 제34권3호
    • /
    • pp.191-198
    • /
    • 2018
  • Fast and accurate diagnosis is needed to eradicate and manage economically important and invasive diseases like fire blight. Loop-mediated isothermal amplification (LAMP) is known as the best on-site diagnostic, because it is fast, highly specific to a target, and less sensitive to inhibitors in samples. In this study, LAMP assay that gives more consistent results for on-site diagnosis of fire blight than the previous developed LAMP assays was developed. Primers for new LAMP assay (named as DS-LAMP) were designed from a histidine-tRNA ligase gene (EAMY_RS32025) of E. amylovora CFBP1430 genome. The DS-LAMP amplified DNA (positive detection) only from genomic DNA of E. amylovora strains, not from either E. pyrifoliae (causing black shoot blight) or from Pseudomonas syringae pv. syringae (causing shoot blight on apple trees). The detection limit of DS-LAMP was 10 cells per LAMP reaction, equivalent to $10^4$ cells per ml of the sample extract. DS-LAMP successfully diagnosed the pathogens on four fire-blight infected apple and pear orchards. In addition, it could distinguish black shoot blight from fire blight. The $B{\ddot{u}}hlmann$-LAMP, developed previously for on-site diagnosis of fire blight, did not give consistent results for specificity to E. amylovora and on-site diagnosis; it gave positive reactions to three strains of E. pyrifoliae and two strains of P. syringae pv. syringae. It also, gave positive reactions to some healthy sample extracts. DS-LAMP, developed in this study, would give more accurate on-site diagnosis of fire blight, especially in the Republic of Korea, where fire blight and black shoot blight coexist.

인덕션 집어등을 설치한 갈치채낚기 어선의 복원성능 (Stability of hair-tail angling fishing boat according to the induction fishing lamp installation)

  • 정성재;박성욱;정명국;정금철
    • 수산해양기술연구
    • /
    • 제59권1호
    • /
    • pp.1-8
    • /
    • 2023
  • In this study, the stability of fishing boat inducing the change of fishing lamp in accordance with the installation of induction lamp in comparison with metal halide lamp was investigated. Inclining test for 8.55 ton class of hair-tail angling fishing boat was performed in order to find a GM and light weight. A stability calculation of the target fishing boat on the basis of KST-SHIP program was evaluated. The stability of the fishing boat with a metal halide lamp such as induction lamp according to the result obtained by the inclining test is slightly different, and the stability is not so much affected. Due to the induction lamp installation, the wind area increased by about 3.178 m2. Before installing the induction fishing lamp, G0M was found to be 0.209 at full load departure and 0.296 at departure from fishing ground. After installing the induction lamp, the full load departure condition is 0.178 and the fishing ground departure condition is 0.260. The G0M value before and after installation of the induction fishing lamp shows a difference of about 3% at the full load departure condition. The value of the critical angle of inclination definition showed a difference of about 16%. Despite these differences, it is lower than the regulations; it was confirmed that there will be no significant difference unless it is in an overloaded state.

Multi LED를 이용한 철도차량용 Door Status Indication Lamp (Development of Multi LED type Door Status Indication Lamp for rolling stock)

  • 서범원;최재성;김동일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1668-1674
    • /
    • 2011
  • Door Inside Lamp of railway rolling stock is installed on interior of the side doors and illuminated at door opening and closing, isolation and fault. So drivers or passengers can notice the door status visually. In the past, a single color or Bi-color LED Lamps have been using and one ~ multiple lamp was used to implement the feature according to client's requirements. (Example: Total of between 2 and 4 lamps are required for the Warning / Emergency operation / Isolation / Fault.) However these design is not easy to apply if there is the mounting space restrictions and the problems such as rising costs can be caused. In addition, it has vulnerability from point of view aesthetic aspects. Therefore the lamp type has been required that has small size and number of colors in order to resolve these problems. Recently multi LED type door status indication lamp have been developed that can meet the requirements and this lamp has been applied in many railway projects. In this study, I'll introduce the general characteristics and mechanical & electrical characteristics of multi LED type door status indication lamp to help development of this kinds of lamp.

  • PDF

Multi LED를 이용한 철도차량용 Door Status Indication Lamp (Development of Multi LED type Door Status Indication Lamp for rolling stock)

  • 서범원;최재성;김동일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1466-1472
    • /
    • 2011
  • Door Inside Lamp of railway rolling stock is installed on interior of the side doors and illuminated at door opening and closing, isolation and fault. So drivers or passengers can notice the door status visually. In the past, a single color or Bi-color LED Lamps have been using and one ~ multiple lamp was used to implement the feature according to client's requirements. (Example: Total of between 2 and 4 lamps are required for the Warning / Emergency operation / Isolation / Fault.) However these design is not easy to apply if there is the mounting space restrictions and the problems such as rising costs can be caused. In addition, it has vulnerability from point of view aesthetic aspects. Therefore the lamp type has been required that has small size and number of colors in order to resolve these problems. Recently multi LED type door status indication lamp have been developed that can meet the requirements and this lamp has been applied in many railway projects. In this study, I'll introduce the general characteristics and mechanical & electrical characteristics of multi LED type door status indication lamp to help development of this kinds of lamp.

  • PDF