• Title/Summary/Keyword: Lamellar phase

Search Result 105, Processing Time 0.026 seconds

The Study of Bone Formation around Titanium Implants Placed in Adrenalectomized Rat's Tibia (부신 제거 백서에 티타늄 임플랜트 매식후 주위 골형성에 관한 연구)

  • Choi, Kab-Lim;Kim, Jong-Ryoul;Park, Bong-Soo;Sung, Iel-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.274-287
    • /
    • 2000
  • The use of dental implants has increased tremendously in recent years and is expected to increase even more in the future. The successful outcome of any implant procedure is surely dependent on interrelationship of the various components of an equation that includes biocompatibility of implant material, macroscopic and microscopic nature of the implant surface, the status of implant bed, surgical technique, undisturbed healing phase and subsequent prosthetic design and long-term loading phase. The purpose of this study was to clarify the effects of adrenalectomy on the osseointegration of pure titanium implants. Seventy rats, 11 weeks of age, were divided into two groups : an adrenalectomized group and a control group. Titanium screw implant(diameter, 2.0mm; length, 3.5mm) was placed into left tibia of 70 rats, 35 in control group and 35 in the experimental group. The rats were sacrificed at different time interval (1, 2, 3, 4, 6, 8, and 12 weeks after implantation) for histopathologic observation, histomorphometric analysis and immunohistochemistry with fibronectin and CD44 antibody. The results obtained from this study were as follows: 1. Histopathogically, findings, newly formed bone was seen at 3 weeks control group and became lamellar bone at 12 weeks. At 6 weeks, lipocytes were observed in bone marrow space. Thickness of regenerated trabecular bone increased till 6 weeks after then, that decreased gradually. 2. By histomorphometric analysis, marrow bone density and contact ratio of marrow bone to implant decreased significantly from 8 to 12 weeks in experimental group compared to control group and also total bone to implant contact ratio decreased significantly from 4 to 12 weeks in experimental group compared to control group. 3. Fibronectin immunoreactivity was very strong at 3 and 4 weeks control group. And after that reduced gradually. But it was continuously strong from 1 to 12 weeks experimental group. 4. CD44 immunoreactivity was very strong in the newly formed osteoblasts at 3 and 4 weeks control group. But it reacted minimally later. However, it reacted continuously strong from 3 to 12 weeks experimental group. From these results, bone to implant contact ratio decreased gradually from 4 weeks in adrenalectomized group compared to control group. CD44 and fibronectin immunoreactivities were strong at all times in adrenalectomized rats. Therefore, it could be stated that immature bone remained continuously for a long time and not readily proceeded into mature status.

  • PDF

A Study on the Moisturizing Effect and Preparation of Liquid Crystal Structures Using Sucrose Distearate Emulsifier (슈크로오스디스테아레이트를 사용한 액정구조의 생성과 보습효과에 관한 연구)

  • Kwak, Myeong-Heon;Kim, In-Young;Lee, Hwan-Myung;Park, Joo-Hoon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2016
  • This study is to make the liquid crystalline structure using sucrose distearate (Sucro-DS) emulsifier to create the hydrophilic type oil-in-water (O/W) emulsion, the droplets of the emulsion having a structure of a multi-lamellar structure. We have studied the physicochemical properties of Sucro-DS using those techniques. And it has been studied in the emulsion performance. In order to form the liquid crystalline structure applying 3 wt% of Sucro-DS, 5 wt% of glycerin, 5 wt% of squalane, 5 wt% of capric/caprylic triglyceride, 3wt% of cetostearyl alcohol, 1wt% of glyceryl mono-stearate, 78 wt% of pure water in mixture having the lamellar structure of stable multi-layer system was found to formed. By applying them, they were described how to create an unstable active material encapsulated cream. Further, the moisturizing cream was studied using this technique. It reported the results to the skin improvement effect by the human clinical trials. The pH range to produce a stable liquid crystal phase using a Sucro-DS was maintained in 5.2~7.5. In order to increase the stability of the liquid crystal, it was when behenyl alcohol containing 3 wt%, the hardness at this time was 13 kg/mm,min. Viscosity of the same amount was 25,000mPas/min. After a test for the effects of the emulsions, the concentration of 6 wt% Sucro-DS is that was appropriate, the particle size of the liquid crystal was 4~6mm. It was observed through a microscope analysis, reliability of the liquid crystal changes for 3 months was found to get stable at each $4^{\circ}C$, $25^{\circ}C$ and $45^{\circ}C$. In clinical trial test, before applying a moisturizing effect it was $13.4{\pm}7%$. Moisturizing cream liquid crystal was not formed in $14.5{\pm}5%$. Therefore, applying than ever before could see the moisture about 8.2% was improved. On the other hand, it was the moisturizing effect of the liquid cream is $19.2{\pm}7%$. The results showed that 43.3% improvement than that previously used. Applications fields, Sucro-DS emulsifier used liquid cream, lotion, eye cream and a variety of formulations can be developed, as well as the cosmetics industry is expected to be wide fields in the application of the external preparation for skin emulsion technology in the pharmaceutical industry and pharmaceutical industry.

The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal (도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구)

  • Kim, Hee-Jin;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.32 no.3
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

Formation of Provitamin-$B_5$ Liquid Crystal with Hydrogenated Lecithin and Its Effectiveness of Moisturizing Activity (HL에 의한 프로비타민-$B_5$ 액정의 형성과 보습효과)

  • Kim, In-Young;Zhoh, Choon-Koo;Ryoo, Hee-Chang
    • Journal of the Korean Applied Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.101-109
    • /
    • 2003
  • Provitamin $B_5$ liquid crystal ($PVB_5$-LC) was the new emulsion system to enhance moisturizing activity on the skin. In this study, it should be mentioned that PVB5-LC could be prepared with the main compound of hydrogenated lecithin (HL) in oil-in water (O/W) emulsion. The key ingredient of humectants was contained 2% of provitamin $B_5$ ($PVB_5$) into the $PVB_5$-LC. The best suitable compositions of $PVB_5$-LC were made from 4.0 wt% of HL, 4.0 wt% of cetostearyl alcohol (CSA) as emulsifier and gelling agent, 3.0 wt% of 1,3-butylene glycol (1,3-BG) and 2.0 wt% of glycerin as moisturizers, 3.0 wt% of cyclomethicone (CMC), 3.0 wt% of isononanoate (ININ), 3.0 wt% of capric/caprylic triglyceride (CCTG), 3.0 wt% of macadamia nut oil (MNO) as emollients. As the analytical result of $PVB_5$-LC, it could know that the distribution range of particle size was 0.14 to 12.37 m level (mean size 3.24 m). It was certified the multi lamellar phase around the droplet of liquid crystal when observed the droplet particles through a polarization microscope. And it clinically was tested the effectiveness of moisturizing activity (in-vivo) compared with control sample (O/W emulsion). The effectiveness of moisturizing activity of $PVB_5$-LC with Skincon-200EX after 6 hours went up 49.0% (p<0.05, n=20) whereas the effectiveness of moisturizing activity of generally O/W emulsion cream was 25.7% (p<005, n=20). Also, in case of Comeometer CM-825, the moisturizing activity of $PVB_5$-LC after 6 hours rose 36.6% (p<0.05, n=20) whereas the effectiveness of moisturizing activity of generally O/W emulsion cream was 10.8%. Therefore, it was known that the effectiveness moisturizing activity of $PVB_5$-LC with HL was remarkably superior compared with O/W emulsion cream.

The Study of Nano-vesicle Coated Powder (나노베시클 표면처리 분체의 개발연구)

  • Son, Hong-Ha;Kwak, Taek-Jong;Kim, Kyung-Seob;Lee, Sang-Min;Lee, Cheon-Koo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.32 no.1 s.55
    • /
    • pp.45-51
    • /
    • 2006
  • In the field of makeup cosmetics, especially, powder-based foundations such as two-way cake, pact and face powder, the quality of which is known to be strongly influenced by the properties of powder, surface treatment technology is widely used as a method to improve the various characteristics of powder texture, wear properties, dispersion ability and so on. The two-way cake or pressed-powder foundation is one of the familiar makeup products in Asian market for deep covering and finishing purpose. In spite of the relent progress in surface modification method such as composition of powders with different characteristics and application of a diversity of coating ingredient (metal soap, amino acid, silicone and fluorine), this product possess a technical difficulty to enhance both of the adhesion power and spreadability on the skin in addition to potential claim of consumer about heavy or thick feeling. This article is covering the preparation and coating method of nano-vesicle that mimic the double-layered lipid lamellar structure existing between the corneocytes of the stratum corneum in the skin for the purpose of improving both of two important physical characteristic of two-way cake, spreadability and adhering force to skin, and obtining better affinity to skin. Nano-vesicle was prepared using the high-pressure emulsifying process of lecithin, pseudo ceramide, butylene glycol and tocopheryl acetate. This nano-sized emulsion was added to powder-dispersed aqueous phase together with bivalent metal salt solution and then the filtering and drying procedure was followed to yield the nano-vesicle coated powder. The amount of nano-vesicle coated on the powder was able to regulated by the concentration of metal salt and this novel powder showed the lower friction coefficient, more uniform condition of application and higher adhesive powder comparing with the alkyl silane treated powder from the test result of spreadability and wear properties using friction meter and air jet method. Two-wav cake containing newly developed coated powder with nano-vesicle showed the similar advantages in the frictional and adhesive characteristics.