• Title/Summary/Keyword: Lack of Oxygen

Search Result 131, Processing Time 0.023 seconds

A Study on Asphyxiation Accidents occurred in the confined space, and their Prevention (밀폐공간 질식재해 발생현황 고찰 및 예방에 관한 연구)

  • Kwon, Bu-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.47-54
    • /
    • 2016
  • A confined space means places where the risk of damage to health caused by lack of oxygen or hazardous gases in inadequate ventilation conditions and the risk of fire and explosion caused by flammable substances. Asphyxiation accidents in a confined space occured every year and also occurred more than two people at the same time. In this study, we surveyed the domestic statistical data occurred the lack of oxygen in confined space for the last 10 years(2006-2015) and, analyzed the accident by industries sector, workplace size etc. 17 fatal work accidents that occurred in confined spaces in Korea between 2013 and 2015 were investigated and analyzed using the database of the KOSHA and suggested interventions to minimize asphyxiation accidents in confined spaces. This paper is expected to be used to establish interventions planning and training as a preventive measures in workplace having confined spaces.

Oxygen detection of sensor cells based on YSZ (Yttria-Stabilized Zirconia) thin films (YSZ(yttria-stabilized zirconia) 박막을 이용한 센서 셀의 산소 감응)

  • 박준용;배정운;황순원;김기동;조영아;전진석;최동수;염근영
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4B
    • /
    • pp.507-513
    • /
    • 1999
  • 8mol%-yttria-stabilized zirconia(YSZ) thin films as oxygen ion conductor were deposited by rf-magnetron sputtering, and the oxygen gas sensors with the structure of $SiO_2$ substrate/Ni-NiO mixed reference layer/Pt/YSZ/Pt were fabricated and their oxygen sensing properties were investigated. The steady-state electro-motive force (EMF) values were measured as a function of oxygen partial pressure ($PO_2;form 1.013\times10^3 \textrm{Pa \;to}\; 1.013\times10^5$Pa) and operating temperature ($300^{\circ}C$ to $700^{\circ}C$). The fabricated YSZ oxygen sensor showed the best oxygen sensing properties at 50$0^{\circ}C$. However, oxygen sensing properties were very low at the temperature lower than 30$0^{\circ}C$ due to the lack of oxygen ion mobility and at the temperature higher than $700^{\circ}C$ due 새 intermixing of materials between the layers. Especially, the YSZ sensor operating at $500^{\circ}C$ and oxygen partial pressure above $1.565\times10^4$Pa showed the oxygen sensing properties close to the values predicted by ideal Nernst equation.

  • PDF

The Role of Lattice Oxygen in the Selective Catalytic Reduction of NOx on V2O5/TiO2 Catalysts (V2O5/TiO2 촉매의 선택적 환원촉매반응에서 격자산소의 역할)

  • Ha, Heon-Phil;Choi, Hee-Lack
    • Korean Journal of Materials Research
    • /
    • v.16 no.5
    • /
    • pp.323-328
    • /
    • 2006
  • In situ electrical conductivity measurements on $V_2O_5WO_3/TiO_2$ catalysts were carried out at between 100 and $300^{\circ}C$ under pure oxygen, NO and $NH_3$ to investigate the reaction mechanism for ammonia SCR (selective catalytic reduction) de NOX. The electrical conductivity of catalysts changed irregularly with supply of NO. It was, however, found that the electrical conductivity change with ammonia supply was regular and the increase of electrical conductivity was mainly caused by reduction of the labile surface oxygen. The electrical conductivity change of catalysts showed close relationship with the conversion rate of NOx. Variation of conversion rate in atmosphere without gaseous oxygen also showed that labile lattice oxygen is indispensable in the initial stage of the de NOx reaction. These results suggest that liable lattice oxygen acts decisive role in the de NOx mechanism. They also support that de NOx reaction occurs through the Eley?Rideal type mechanism. The amount of labile oxygen can be estimated from the measurement of electrical conductivity change for catalysts with ammonia supply. This suggests that measurement of the change can be used as a measure of the de NOx performance.

Effects of Electrolytes, pH, Glucose, Acetic acid and Propionic acid on Oxygen Consumption in Clonorchis Sinensis (배양액(培養液)의 성분(成分) 및 배양시간(培養時間)의 변화(變化)에 따른 간흡충(肝吸?)의 산소소비(酸素消費)에 미치는 영향(影響))

  • Kim, Hwa-Woong;Choi, Hyung-Kon;Yun, Byung-Oh;Ha, Young-Ho
    • The Korean Journal of Pharmacology
    • /
    • v.5 no.1
    • /
    • pp.17-22
    • /
    • 1969
  • Oxygen consumption by Clonorchis sinensis (C.S.) was observed in a medium of valuable pH of KRP, lack of certain electrolytes of KRP and of glucose, acetic acid or propionic acid was added to KRP. The results were as follows. 1. In a different solutions, KRP with or without $0.4%-glucose$, $0.9%-saline$ solution, the variation of oxygen consumption by C.S. was not significant. 2. Oxygen consumption by C.S. was inhibited by the solution of KCI, $CaCl_2$, or $MgSO_4$ in a 0.9% solution of saline. 3. Under the acidity, oxygen consumption was enhanced but under the alkality, it was inhibited. 4. Oxygen consumption by C.S. was inhibited by acetic acid or propionic acid in KRP solution. 5. C.S. keeping in KRP solution for a long duration, oxygen cosumption was reduced in the course of time.

  • PDF

A Study on Application of Air-Ventilation System Depending on Oxygen-Density in a Vehicle (자동차 실내 산소농도에 따른 환기설정에 관한 연구)

  • 허성관;박동은;권택진;최종탁
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.4 no.4
    • /
    • pp.154-163
    • /
    • 1999
  • This paper perform the experiment, under the various conditions, for the influence of the lack of O2 to the drivers This study was focus of studying the system of the automatic ventilating system The result of this study can implementation of improving the working environment where the working environment is closed space like vehicle. It is very close relation that the oxygen-density and there consumption between human body. And then assisting this study, recognizing the variable types of the oxygen consumption in a human body. In this system, examination and research the element and density of the oxygen related. And analize the time to take refreshment of drivers.

  • PDF

Electrical Conductivity of Ytterbium Sesquioxide ($Yb_2O_3$) ($Yb_2O_3$의 전기 전도도)

  • 강영환;최재시;윤기현
    • Journal of the Korean Ceramic Society
    • /
    • v.18 no.1
    • /
    • pp.23-26
    • /
    • 1981
  • The electrical conductivity of highly pure polycrystalline $Yb_2O_3$ has been measured from 650 to 105$0^{\circ}C$ under oxygen pressure range of $10^{-5}$ to 102 torr. The conductivity dependence of oxygen pressure in the temperature region from 750 to 105$0^{\circ}C$ is approximated by $\sigma$ $\alpha$ $Po_2^{1/5.3}$. This shows that the conduction mechanism is associated with doubly ionized metal vacancies. Fairly low activation energy and the lack of oxygen pressure dependence are found over the temperature range of 650 to 75$0^{\circ}C$. The conduction mechanism can be explaned by not metal vacancies, but hopping oxygen ions in the oxide.

  • PDF

Study on the Charging Characteristics of a Sealed Type Ni-Cd Cell (밀폐식 Ni-Cd 전지의 충전특성에 관한 연구)

  • Yung Woo Park;Chai Won Kim;Mu Shik Jhon
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.6
    • /
    • pp.347-352
    • /
    • 1971
  • The variations of the positive and negative electrode potentials, and of internal pressure were measured during the charge of the sealed type Ni-Cd cell. Both polarization characteristics of a paste type Cd-electrode as a gas diffusion electrode in 30% KOH solution and the effects of active carbon electrode as an oxygen consuming auxiliary electrode of the Ni-Cd cell on the charging characteristics of the cell were studied. Peak voltage at the end of charge of the cell is ascribed to the peak at the negative electrode potential, which is due to the concentration polarization by the lack of $Cd^{++}$ ion and oxygen concentration. And the recovery of the negative electrode potential is resulted from depolarization by the increasing diffusion limiting current density with the increasing oxygen pressure. The active carbon electrode was effective as an oxygen consuming auxiliary electrode. The internal pressure of the cell could be maintained below 200mmHg even at one hour rate charge and overcharge by the use of active carbon electrode as an auxiliary electrode.

  • PDF

Effect of Amino Acids and Dissolved Oxygen on Expression of Invertase in Recombinant Saccharomyces cerevisiae (재조합 Saccharomyces cerevisiae의 Invertase 발현에 미치는 아미노산과 용존산소의 영향)

  • 신해헌;조정섭;변유량;박혜영
    • Microbiology and Biotechnology Letters
    • /
    • v.20 no.3
    • /
    • pp.348-354
    • /
    • 1992
  • In order to improve the productivity of invertase by recombinant Saccharomyces cerevisiae containing SUC2 gene, the effect of amino acids and dissolved oxygen concentration on the gene expression was investigated. Optimal concentrations of leucine and histidine for cell growth and cloned gene expression were 0.03 gig and 0.04 gig, respectively, expressed as the ratio of amino acid/glucose. The lack or excess of leucine and histidine has inhibitory effect on cell growth and invertase expression. In batch culture, the less aeration was, the higher invertase activity was. In continuous culture at a dilution rate of 0.09 h 1 with controlled dissolved oxygen tension, invertase activity increased dramatically at DOT levels below 5% air saturation, and a maximum activity of 215.54 KUlg cell was obtained under unaerated condition.

  • PDF

Exhaust Emissions Characteristics on the SI Engine according to the Air-Fuel Mixture with Ozone (혼합기 오존 첨가에 따른 SI기관의 배기배출물 특성)

  • Lee, B.H.;Yi, C.S.;Lee, Y.H.;Lee, C.K.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.5-10
    • /
    • 2006
  • In a conventional and lean operating engine, the state of mixture is very important in the combustion and emission characteristics. Lean operation is known to decrease the formation while maintaining a good fuel economy, but the unstable operation due to misfire and erratic combustion prevents engines from being operated at very lean mixtures, so both combustion rates and exhaust emission formation need to be satisfied comparably. In this study, it is designed and experimented the modified engine, and analyzed the combustion and exhaust emission according to the change of engine speed and with adding ozone. The conclusions were drawn out and enumerated as follows. 1. At the experimental result of automobile diesel engine, it has been verified that the formation of particulate matter(PM) gas is able to be lower with the addition of optimum quantities of ozone. 2. Carbon monoxide(CO) was formed by the lack of oxygen and the thermal dissociation in the combustion process. Therefore, with the change of swirl valve's position and addition of oxygen and ozone, CO formation was decreased by the increasing of excessive O2, but it was increased by the temperature of combustion gas growing higher. As a result of the two effects, CO formation was decreased in this study. 3. Hydrocarbon(HC) was formed by the lack of O2, and the flow of mixture in cylinder. According to opening of the swirl valve and adding the oxygen and ozone, hydrocarbon gas was decreased by 20%, 9%, and 27.5%, respectively. 4. Nitric oxides($NO_x$) was strongly affected by the combustion gas temperature. As a result of respectively experimental conditions, $NO_x$ formation was increased about 20% due to (be the) high(er) combustion gas temperature.

  • PDF

Perception of Long-Term Oxygen Therapy for Chronic Lung Diseases May Affect Poor Adherence in Korea

  • Hyo Jin Kim;Hongyeul Lee;Ji Young Yang;Jae Ha Lee;Seung Won Ra;SungMin Hong;Ho Young Lee;Sung Hyun Kim;Mi-Yeong Kim;Hyun-Kyung Lee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.1
    • /
    • pp.100-114
    • /
    • 2024
  • Background: Long-term oxygen therapy (LTOT) improves the survival of patients with hypoxemia due to chronic respiratory diseases. The clinical outcomes of LTOT are strongly associated with patient adherence. To improve the adherence of patients, physicians have focused on the efficacy of LTOT. However, poor adherence may stem from patients' perceptions of LTOT. Herein we evaluated patients' perceptions of LTOT affecting adherence. Methods: We conducted a cross-sectional survey study using descriptive, open, and closed-ended questionnaire. Patients using oxygen therapy (OT) or requiring it but avoiding OT responded to the questionnaires at three university hospitals. Results: Seventy-nine patients responded to the questionnaires. The number of patients using home and portable OT was 69 (93%) and 37 (46.3%), respectively. Patients with good adherence were 22 (30.1%). Among patients with good adherence, 90.9% used oxygen according to physicians' prescriptions whereas only 37.3% of those with poor adherence followed physicians' prescriptions (p<0.01). The reasons for avoiding using home OT were fear of permanent use (50%), unwanted attention (40%), and lack of symptoms (40%). They avoided portable OT because of unwanted attention (39%), heaviness (31.7%), and lack of symptoms (21.6%). Conclusion: Patients on LTOT had the perception of the misunderstanding the effects of OT and of psychosocial barriers to initiate or use LTOT. Considering these findings, health professionals need to provide effective education on the purpose of LTOT to improve patient adherence to OT and provide sufficient support for the management of psychosocial barriers in patients using LTOT.