• 제목/요약/키워드: Labview S/W

검색결과 11건 처리시간 0.025초

태양광발전용 컴퓨터기반의 집속화된 데이터 취득 시스템의 개발 및 적용 (Development and Application of A Computer-Based Integrated Data-Acquisition System for PV System Monitoring)

  • 유형철;송정용;황명근;허창수
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.67-76
    • /
    • 2002
  • Data-Acquisition systems are widely used in Photovoltaic(PV) system application in order to analyze and optimize the performance of PV systems. In this paper, the development of a computer-based data-acquisition system and its application are described. The proposed Computer-based data-acquisition System consists of a set of sensors for measuring both environmental and electrical parameters. The collected data are first conditioned and then interfaced to PC using a data-acquisition card. The Labview program was used to further process, display on the monitor at real time and store on the hard disk. We designed and installed two stand-alone PV systems to supply different loads, which in this case a Low Pressure Sodium(LPS) 55 [W] lamp and a electrodless 55 [W] lamp. When the proposed data acquisition system is applied on the designed PV systems, Optimized system operation methods are investigated to confirm a stable load availability and extend battery life time.

가정용 전력소비형태 분석을 위한 모니터링 프로그램 구현 (Implementation of the Monitoring Program for the Analysis of Electric Consumption Characteristics in Home Appliances)

  • 유원호;권혁대;최재혁;고성훈;전칠환;이성룡
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.547-549
    • /
    • 2008
  • This paper presents a implementation of the monitoring program for the analysis of electric consumption characteristics in home appliances, which uses a Labview program from National Instruments Corporation. It is can provide to be easy for small-scale researcher, development groups or individual researcher to analyze electric power consumption characteristics. Also, this paper apply to actual private home and then, analyze result of monitoring and a database result of power quality etc, like the power consumption form, power factor and harmonic which follow season, and time zone. For this measured the apartment where the family which is four lives in the object.

  • PDF

방사능 수치 오염 지도 작성을 위한 방사선 계측 시스템 연구 (Study of Radiation Mapping System for Water Contamination in Water System)

  • 나원경;김한수;연제원;이레나;하장호
    • 방사선산업학회지
    • /
    • 제5권2호
    • /
    • pp.185-189
    • /
    • 2011
  • As nuclear industry has been developed, a various types of radiological contamination has occurred. After 9.11 terror in U.S.A., it has been concerned that terrorists' active area has been enlarged to use nuclear or radioactive substance. Recently, the most powerful earth-quake stroke, which triggered a massive tsunami in Japan and then Fukushima nuclear power plant reactor has suffered from a serious accident in history. The Fukushima reactor accident has occurred an anxiety of radiation leaks and about 170,000 people have been evacuated from the accidental area near the nuclear power plant. For these reasons, a social chaos can be occurred if radiological contamination occurs to the supply system for the drinking water. As such, the establishment of the radiation monitoring system for the city main water system is compelling for the national security. In this study, a feasibility test of radiation monitoring system which consists of unified hybrid-type radiation detectors was experimented for multi detection system by using gamma-ray imaging. The hybrid-type radiation sensors were fabricated with CsI(Tl) scintillators and photodiodes. A preamplifier and amplifier was also fabricated and assembled with the sensor in the shielding case. For the preliminary test of detection of radiological contamination in the river, multi CsI(Tl)-PIN photodiode radiation detectors and $^{137}Cs$ gamma-ray source were used. The DAQ was done by Linux based ROOT program and NI DAQ system with Labview program. The simulated contamination was assumed to be occurred at Gapcheon river in Daejeon city. Multi CsI(Tl)-PIN photodiode radiation detectors were positioned at the Gapcheon river side. Assuming that the radiological contaminations flows in the river the $^{137}Cs$ gamma-ray source has been moved and then, the contamination region was reconstructed.

셀프에너지 밸런싱을 고려한 리튬이온전지의 Battery Management System 구현 (Implementation of Battery Management System for Li-ion Battery Considering Self-energy Balancing)

  • 김지명;이후동;태동현;페레이라 마리토;박지현;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권3호
    • /
    • pp.585-593
    • /
    • 2020
  • 현재까지 총 29건의 전기저장장치의 화재가 발생되었는데, 이 중 22건이 신재생에너지 연계용이며, 완전충전 이후, 운전대기 상태인 휴지기간 동안에 계절과 무관하게 화재사고가 발생되었다. 이것은 병렬로 연결된 셀들의 SOC 상태가 서로 다른 경우, 의도하지 않게 SOC가 높은 셀에서 낮은 셀로 전류가 이동하는 셀프에너지 밸런싱 현상으로, 일부 셀이 과충전되어 열폭주로 인한 화재의 원인으로 평가되고 있다. 따라서, 본 논문에서는 전기저장장치의 셀프에너지 밸런싱을 방지하는 새로운 BMS의 회로구성과 운용 알고리즘 그리고 SOC 평가알고리즘을 제안한다. 제안한 알고리즘과 구현한 BMS를 바탕으로 리튬이온전지의 열화 특성과 열화 및 정상 셀 간의 셀프에너지 밸런싱 특성을 분석한 결과, 정상 셀 대비 열화 셀의 방전 용량 비율은 91.75[%]이며, 열화율이 8.25[%]임을 알 수 있었고, SOC가 높은 정상 셀에서 SOC 낮은 열화 셀로 전류가 이동하는 셀프에너지 밸런싱 현상이 발생함을 확인하였다. 또한, 셀프에너지 밸런싱 전류가 과도하게 높아지는 경우, BMS가 확실하게 셀들의 병렬연결을 분리하여, 리튬이온전지의 안전성을 향상시킬 수 있어, 본 논문에서 제안한 BMS의 유용성을 확인하였다.

투수성 포장재의 우수 표면유출 저감 효과 (The Effect of Pervious Pavement on Reducing the Surface Runoff)

  • 이춘석;류남형;한승호
    • 한국환경복원기술학회지
    • /
    • 제11권6호
    • /
    • pp.26-37
    • /
    • 2008
  • The purpose of the study was to evaluate the effect of pervious pavements on reducing the surface runoff caused by rainfall. The surface runoff from twelve steel experimental beds with different pavement had been recorded every minute from May to September 2008, by the measuring system of tipping buckets(0.1mm/count) and data aquisition systems(National Instrument's Labview and DAQ boards & Autonics PR12-4). The dimension of the experimental bed was $1.5m(W){\times}2.0m(L){\times}0.6m(D)$ and eleven different kinds of vegetational(grass, grass+cubic stone, grass+hole brick), modular(brick, cubic stone, small cubic stone, wood block, interlocking block, clay brick, granular clay brick) and granular(naked soil, gravel) paving materials and concrete were applied for the comparison. Six rain events with depth over 30mm were selected and compared. The maximum depth of the rainfall selected was 137.5mm for 28 hours, and the minimum 30mm for 5 hours. The maximum rainfall per hour was 23mm/hr and the minimum 11.4mm/hr. The major findings were as follows; 1. All pervious pavement applied reduced over 75% of the surface runoff compared with concrete pavement. The grassy and porous pavements were relatively efficient in reducing surface runoff. 2. The grass was the more efficient as intercepting average 69.5mm of initial surface runoff, and maximum 77.8mm at the condition of 13.5mm/hr rainfall. The next was gravel intercepting maximum 65.5mm at the condition of 13.5mm/hr and the 40.9mm at 19.1mm/hr, average 55.7mm. 3. The modular pavements common in urban area were not good in intercepting the runoff except the 'clay granular brick' compared with others. The 'clay granular brick' showed relatively efficient intercepting average 14.1mm, which was the bigger amount than the 'grass+hole brick'. 4. The 'naked soil' were more effective than the 'concrete', 'brick', and 'interlocking block' in reducing the surface runoff, but less efficient than other materials. The capacity of the 'naked soil' to intercept the initial rainfall was similar to the 'brick'. As summary, the more grassy and porous pavement shows more effective in reducing surface runoffs.

이차전지의 상태 감시 및 수명 예측 알고리즘 개발 (Development of State of Charge and Life Cycle Evaluation Algorithm for Secondary Battery)

  • 박재범;김병기;송석환;노대석
    • 한국산학기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.369-377
    • /
    • 2013
  • 현재 전기자동차와 신재생에너지전원의 출력안정화에 필수적인 2차전지가 개발되고 있고, 2차전지의 효율적인 운용을 위하여 상태감시 기술과 수명예측 기술이 요구되고 있다. 기존의 2차전지 상태감시 방법으로는 전압과 비중에 의한 충전상태평가 방법 등이 있으나, 이 방법은 온도에 따라 변화되는 전압과 비중의 특성을 고려할 수 없는 한계점을 가지고 있다. 즉, 2차전지의 SOC를 평가하기 위해서는 전지 케이스 내부의 전해액 온도에 따라 달라지는 비중 값을 측정해야 하지만, 대부분의 2차전지는 밀폐형으로 보급되고 있어서 전해액의 상태를 파악하기 어려운 실정이다. 따라서 본 논문에서는 전지내부의 온도를 보정하는 열전달식을 유도함으로 정확한 SOC평가 알고리즘을 제시하였다. 또한 2차전지의 수명 예측 방법으로는 내부저항 측정 또는 잔존 용량 측정 등의 수명 예측 방법들이 있으나, 충 방전상태와 충전 후 방치시간, 사용 환경 등 여러 가지 요인에 의해 2차전지의 수명을 정확하게 판단하기 어렵다. 따라서 상기의 문제점을 해결하기 위해 $20^{\circ}C$로 환산된 비중 값에 대하여 전지의 충 방전에 대한 비중누적 값을 계산함으로 충 방전 사이클을 판정하는 수명예측 알고리즘을 제시하였다. 상기에서 제시한 알고리즘을 바탕으로 시험 장치를 제작하여 다양한 시뮬레이션을 수행한 결과, 기존의 방법에 비하여 본 논문에서 제안한 알고리즘이 정확한 연축전지의 상태감시 및 수명예측에 대한 결과를 얻을 수 있음을 확인하였다.

EV용 이동형 전원공급장치의 구현 및 경제성 평가에 관한 연구 (Implementation and Economic Evaluation of Movable Power Supply Device for Electric Vehicle)

  • 최성문;한병길;이후동;김미영;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.77-86
    • /
    • 2020
  • 기존의 고정형 EV(electric vehicle) 충전기는 이용률이 증가하게 되면 충전 인프라 설비 부족으로 인해 사용자의 충전 대기시간이 길어지는 불편함이 발생할 수 있고, EV 충전기를 증설하는 경우, 배전선로(지중) 증설비용 및 선로의 전압강하로 인한 전력품질 문제가 발생할 수 있다. 따라서, 본 논문에서는 상기의 문제점을 해결하고, EV 충전기 부족으로 인한 불편함을 해결할 수 있는 EV용 이동형 전원공급장치(movable power supply device, MPSD)를 제안한다. 제안한 MPSD는 태양광전원부, 에너지저장부, EV용 충전기부, 감시제어부로 구성되고, 사용자의 환경요소에 따라 MPSD를 유연하게 이용할 수 있도록 3가지 운용모드로 나눌 수 있다. 또한, 경제성 평가 모델링을 비용요소와 편익요소로 구분한다. 여기서, MPSD의 비용요소로는 태양광전원부, 에너지저장부, EV 충전기부, 감시제어부의 설비비용과 기존의 EV 충전기 설비비용, 배전선로 증설비용, 기존의 EV 충전기 운용비용등의 편익요소로 구성되며, 이를 바탕으로 현재 가치 환산법을 사용하여 경제성을 평가한 결과, MPSD가 기존의 고정형 EV 충전기보다 유리함을 알 수 있었고, 설치지점의 거리에 따라 편익이 크게 좌우함을 확인하였다.

통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향 (The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제40권5호
    • /
    • pp.100-108
    • /
    • 2012
  • 통풍과 차양이 하절기 옥외공간에서 인간이 느끼는 온열쾌적성에 어떤 영향을 미치는지를 객관적으로 검증하기 위하여 통풍과 차양을 달리한 실험구를 조성하고 흑구온도와 기온 및 풍속을 측정하여 평균복사온도를 환산하여 비교 분석하였다. 미기후 측정을 위하여 개방된 잔디밭에 철제 각관을 이용하여 가로${\times}$세로${\times}$높이가 각각 $3m{\times}3m{\times}1.5m$인 프레임을 구성하고, 투명 폴리에틸렌 필름과 농업용 차광막을 이용하여 통풍과 차양의 조건을 달리한 네 가지의 실험구를 조성하였다. 각 실험구 내 중심부 지면으로부터 1.2m 높이에서 베인형 풍속계와 흑구, 측온저항체(PT-100)를 이용하여 2011년 5월 1일부터 동년 9월 30일까지 풍속과 기온, 흑구온도를 매 분 단위로 계측하였다. 기상조건과 계측자료의 유효성 등을 고려하여 총 44일 동안의 13,262건의 자료를 바탕으로 실험구별 일중 시계열적 변화를 분석하였으며, 낮 시간에 해당되는 오전 7시부터 오후 8시까지의 7,172건의 자료를 바탕으로 실험구에 따른 통계적 차이를 해석하였다. 아울러 햇볕이 가장 강렬한 시간대인 오전 11시부터 오후 4시까지의 자료를 바탕으로 평균복사온도와 풍속 및 일사량과의 관계를 분석하였다. 평균복사온도를 기준으로 해석했을 때, 통풍이 차단된 노지에서의 측정기간 중 최고값이 $58.84^{\circ}C$까지 상승한 반면, 차양이 적용되고 통풍이 원할한 실험구의 최고값은 $42.94^{\circ}C$였다. 시험결과를 종합하면, 하절기 옥외공간에서 낮 동안의 평균복사온도에 있어서 차양에 의해서는 최대 $13^{\circ}C$, 평균 $9^{\circ}C$의 냉각효과가 발생한 반면, 방풍에 의해서는 반대로 평균 약 $3^{\circ}C$의 가열효과가 있는 것으로 정리되어, 통풍이 되지 않는 태양직사광 지역은 바람이 원활하게 통하는 그림자 지역 보다 최대 $16^{\circ}C$까지 높은 것으로 나타났다. 결론적으로 본 연구를 통해서 하절기 옥외공간의 열쾌적성을 개선하는데 차양이 가장 중요하며, 그 다음이 통풍이라는 사실을 파악할 수 있었다. 따라서 옥외공간에 더 많은 녹음수와 숲을 조성하여 그림자 지역을 증가시킴으로써 인간의 하절기 옥외활동에 많은 제약을 주고 있는 불필요한 열에너지를 현격하게 저감시켜 쾌적한 미기후를 효과적으로 조성할 수 있으며, 나아가 정교하게 조성된 바람길이나 통풍 시스템을 적용한다면 도시 전체의 열환경도 효과적으로 개선할 수 있을 것이다.