• Title/Summary/Keyword: Labview S/W

Search Result 11, Processing Time 0.024 seconds

Development and Application of A Computer-Based Integrated Data-Acquisition System for PV System Monitoring (태양광발전용 컴퓨터기반의 집속화된 데이터 취득 시스템의 개발 및 적용)

  • Yoo, H.C.;Song, J.Y.;Hwang, M.K.;Huh, C.S.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.67-76
    • /
    • 2002
  • Data-Acquisition systems are widely used in Photovoltaic(PV) system application in order to analyze and optimize the performance of PV systems. In this paper, the development of a computer-based data-acquisition system and its application are described. The proposed Computer-based data-acquisition System consists of a set of sensors for measuring both environmental and electrical parameters. The collected data are first conditioned and then interfaced to PC using a data-acquisition card. The Labview program was used to further process, display on the monitor at real time and store on the hard disk. We designed and installed two stand-alone PV systems to supply different loads, which in this case a Low Pressure Sodium(LPS) 55 [W] lamp and a electrodless 55 [W] lamp. When the proposed data acquisition system is applied on the designed PV systems, Optimized system operation methods are investigated to confirm a stable load availability and extend battery life time.

Implementation of the Monitoring Program for the Analysis of Electric Consumption Characteristics in Home Appliances (가정용 전력소비형태 분석을 위한 모니터링 프로그램 구현)

  • Yoo, W.H.;Kwon, H.D.;Choi, J.H.;Ko, S.H.;Jeon, C.H.;Lee, S.R.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.547-549
    • /
    • 2008
  • This paper presents a implementation of the monitoring program for the analysis of electric consumption characteristics in home appliances, which uses a Labview program from National Instruments Corporation. It is can provide to be easy for small-scale researcher, development groups or individual researcher to analyze electric power consumption characteristics. Also, this paper apply to actual private home and then, analyze result of monitoring and a database result of power quality etc, like the power consumption form, power factor and harmonic which follow season, and time zone. For this measured the apartment where the family which is four lives in the object.

  • PDF

Study of Radiation Mapping System for Water Contamination in Water System (방사능 수치 오염 지도 작성을 위한 방사선 계측 시스템 연구)

  • Na, Teresa W.;Kim, Han Soo;Yeon, Jei Won;Lee, Rena;Ha, Jang Ho
    • Journal of Radiation Industry
    • /
    • v.5 no.2
    • /
    • pp.185-189
    • /
    • 2011
  • As nuclear industry has been developed, a various types of radiological contamination has occurred. After 9.11 terror in U.S.A., it has been concerned that terrorists' active area has been enlarged to use nuclear or radioactive substance. Recently, the most powerful earth-quake stroke, which triggered a massive tsunami in Japan and then Fukushima nuclear power plant reactor has suffered from a serious accident in history. The Fukushima reactor accident has occurred an anxiety of radiation leaks and about 170,000 people have been evacuated from the accidental area near the nuclear power plant. For these reasons, a social chaos can be occurred if radiological contamination occurs to the supply system for the drinking water. As such, the establishment of the radiation monitoring system for the city main water system is compelling for the national security. In this study, a feasibility test of radiation monitoring system which consists of unified hybrid-type radiation detectors was experimented for multi detection system by using gamma-ray imaging. The hybrid-type radiation sensors were fabricated with CsI(Tl) scintillators and photodiodes. A preamplifier and amplifier was also fabricated and assembled with the sensor in the shielding case. For the preliminary test of detection of radiological contamination in the river, multi CsI(Tl)-PIN photodiode radiation detectors and $^{137}Cs$ gamma-ray source were used. The DAQ was done by Linux based ROOT program and NI DAQ system with Labview program. The simulated contamination was assumed to be occurred at Gapcheon river in Daejeon city. Multi CsI(Tl)-PIN photodiode radiation detectors were positioned at the Gapcheon river side. Assuming that the radiological contaminations flows in the river the $^{137}Cs$ gamma-ray source has been moved and then, the contamination region was reconstructed.

Implementation of Battery Management System for Li-ion Battery Considering Self-energy Balancing (셀프에너지 밸런싱을 고려한 리튬이온전지의 Battery Management System 구현)

  • Kim, Ji-Myung;Lee, Hu-Dong;Tae, Dong-Hyun;Ferreira, Marito;Park, Ji-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.585-593
    • /
    • 2020
  • Until now, 29 fire accidents have occurred; 22 of them were caused by the interconnection of renewable energy sources that occurred during the rest period after the lithium-ion battery had been fully charged regardless of the seasons. The fire accidents of ESS were attributed to thermal runaway due to the overcharging of a few cells with the phenomenon of self-energy balancing, which is unintentional current flow from cells with a high SOC to the low cells if the SOC condition of each cell connected in parallel is different. Therefore, this paper proposes a novel configuration and operation algorithm of the BMS to prevent the self-energy balancing of ESS and presents a hybrid SOC estimation algorithm. From the test results of the self-energy balancing phenomenon between aging and normal cells based on the proposed algorithm and BMS, it was confirmed the possibility of self-energy balancing, which is unintentional current flow from cells with a high SOC to cells with a low SOC. In addition, the proposed configuration of the BMS is useful and practical to improve the safety of lithium-ion batteries because the BMS can reliably disconnect a parallel connection of the cells if the self-energy balancing current becomes excessively high.

The Effect of Pervious Pavement on Reducing the Surface Runoff (투수성 포장재의 우수 표면유출 저감 효과)

  • Lee, Chun-Seok;Ryu, Nam-Hyung;Han, Seung-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.6
    • /
    • pp.26-37
    • /
    • 2008
  • The purpose of the study was to evaluate the effect of pervious pavements on reducing the surface runoff caused by rainfall. The surface runoff from twelve steel experimental beds with different pavement had been recorded every minute from May to September 2008, by the measuring system of tipping buckets(0.1mm/count) and data aquisition systems(National Instrument's Labview and DAQ boards & Autonics PR12-4). The dimension of the experimental bed was $1.5m(W){\times}2.0m(L){\times}0.6m(D)$ and eleven different kinds of vegetational(grass, grass+cubic stone, grass+hole brick), modular(brick, cubic stone, small cubic stone, wood block, interlocking block, clay brick, granular clay brick) and granular(naked soil, gravel) paving materials and concrete were applied for the comparison. Six rain events with depth over 30mm were selected and compared. The maximum depth of the rainfall selected was 137.5mm for 28 hours, and the minimum 30mm for 5 hours. The maximum rainfall per hour was 23mm/hr and the minimum 11.4mm/hr. The major findings were as follows; 1. All pervious pavement applied reduced over 75% of the surface runoff compared with concrete pavement. The grassy and porous pavements were relatively efficient in reducing surface runoff. 2. The grass was the more efficient as intercepting average 69.5mm of initial surface runoff, and maximum 77.8mm at the condition of 13.5mm/hr rainfall. The next was gravel intercepting maximum 65.5mm at the condition of 13.5mm/hr and the 40.9mm at 19.1mm/hr, average 55.7mm. 3. The modular pavements common in urban area were not good in intercepting the runoff except the 'clay granular brick' compared with others. The 'clay granular brick' showed relatively efficient intercepting average 14.1mm, which was the bigger amount than the 'grass+hole brick'. 4. The 'naked soil' were more effective than the 'concrete', 'brick', and 'interlocking block' in reducing the surface runoff, but less efficient than other materials. The capacity of the 'naked soil' to intercept the initial rainfall was similar to the 'brick'. As summary, the more grassy and porous pavement shows more effective in reducing surface runoffs.

Development of State of Charge and Life Cycle Evaluation Algorithm for Secondary Battery (이차전지의 상태 감시 및 수명 예측 알고리즘 개발)

  • Park, Jaebeom;Kim, Byeonggi;Song, Seokhwan;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.369-377
    • /
    • 2013
  • This paper deals with the state of charge(SOC) and life cycle evaluation algorithm for lead-acid battery, which is essential factor of the electric vehicle(EV) and the stabilization of renewable energy in the smart grid. In order to perform the effective operation of the lead-acid battery, SOC and life cycle evaluation algorithm is required. Specific gravity with the change of electrolyte temperature inside battery case should be obtained to evaluate the SOC of lead-acid battery, however it is difficult to measure the electrolyte temperature of sealed type lead-acid battery. To overcome this problem, this paper proposes the equation of thermal transmission to compensate internal temperature of the lead-acid battery. Also, it is difficult to exactly evaluate the life cycle of battery, depending on the operation conditions of lead-acid battery such as charging and discharging state, self discharging rate and environmental issue. In order to solve the problem, this paper presents the concept for gravity accumulation of charge and discharge cycle, which is the value converted at $20^{\circ}C$. By using the proposed algorithm, this paper propose the test device based on the Labview software. The simulation results show that it is a practical tool for the maintenance of lead-acid battery in the field of industry.

Implementation and Economic Evaluation of Movable Power Supply Device for Electric Vehicle (EV용 이동형 전원공급장치의 구현 및 경제성 평가에 관한 연구)

  • Choi, Sung-Moon;Han, Byeong-Gill;Lee, Hu-Dong;Kim, Mi-Young;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.77-86
    • /
    • 2020
  • Power quality problems caused by feeder voltage drop and extension construction cost problems can occur with the increasing utilization rates of the existing fixed-type EV (electric vehicle) charger. Moreover, EV users might not be able to access the EV charger due to a lack of EV charging facilities. Therefore, this paper proposes an MPSD (movable power supply device) for EVs to overcome user inconvenience caused by the insufficient number of chargers and extension cost issues. The proposed MPSD was mainly composed of a PV (photovoltaic) system, ESS (energy storage system), EV charging system, and monitoring and control system. Furthermore, there are three operation modes available to enhance the flexibility of the MPSD application, depending on the situation. This paper also presents an economical evaluation modeling using the present worth method to consider the cost and benefit elements. The simulation results based on proposed modeling showed that MPSD is more economical than the existing EV charger. Moreover, its profit can be increased significantly depending on the distance to the installation point.

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.