• 제목/요약/키워드: Laboratory test and field test

검색결과 1,079건 처리시간 0.03초

Wavelength Division Multiplexing-Passive Optical Network Based FTTH Field Trial Test

  • Kim, Geun-Young;Kim, Jin-Hee
    • Journal of the Optical Society of Korea
    • /
    • 제11권3호
    • /
    • pp.101-107
    • /
    • 2007
  • In this paper, we have presented the results of Wavelength Division Multiplexing-Passive Optical Network (WDM-PON) based fiber-to-the-home (FTTH) field trial test which was held in the city of Gwangju. We have implemented an injection locked Fabry-Perot Laser Diode (FP-LD) based WDM-PON system and reliably delivered Internet Protocol TV (IP-TV), networked Personal Video Recorder (N-PVR), High-Definition Video on Demand (HD-VoD), Education on Demand (EoD) and Internet service as FTTH service through the system during the field trial test. We have also verified that the WDM-PON system worked well to provide quality of service (QoS) guaranteed 100Mbps bandwidth per subscriber. Furthermore, we have presented network designing issues in Outside Plant (OSP) and Customer Premises Network (CPN) that should be overcome to efficiently deploy FTTH service. Finally, based on the field trial test results, we proposed FTTH service deployment strategies.

연약지반에 대한 현장시험 적용에 관한 연구 (A STUDY ON THE APPLICATION OF FIELD TESTS TO WEAK GROUND)

  • 이승래;정한중;김준석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1992년도 가을학술발표회 논문집
    • /
    • pp.145-148
    • /
    • 1992
  • This paper reports the application of field tests to weak ground. In this study, field and laboratory tests were performed in the west seashore of KOREA(Ildo, Sore, Kunsan, Youngam). Applied tests are standard penetration test, cone penetration test, dilatometer test, field vane test, unconsolidated undrained test, oedometer test and other fundametal material properties tests. The results of in-situ test are used to estimate soil types and undrained shear strengths of five clay local deposits. SPT results showed low reliability and FVT war also demonstrated the best field test to weak clayey deposits.

  • PDF

중온아스팔트 혼합물의 현장 적용성 및 실내 공용성 평가 (A Study on Field Application and Laboratory Performance Evaluation of Warm Mix Asphalt)

  • 양성린;백철민;정규동;김영민;김용주;황성도
    • 한국도로학회논문집
    • /
    • 제14권4호
    • /
    • pp.9-18
    • /
    • 2012
  • PURPOSES : This study evaluated the field applicability and laboratory performance of warm-mix asphalt (WMA) as an alternative technology in asphalt pavement. METHODS : The pilot road using two different types of WMA mixture and one HMA mixture was constructed in Waegwan-Seokjeok road construction site and the mixtures were sampled at the asphalt plant for laboratory testings. The field applicability was assessed in environmental aspects, such as $CO_2$ emission, and in aspects of constructibility using the existing equipment and procedure, i.e., thickness and density measurement. The laboratory testings included the moisture susceptibility test by AASHTO T283, dynamic modulus test, triaxial repeated load permanent deformation test, and the fatigue test. RESULTS : The temperatures for production and compaction of WMA were $20{\sim}30^{\circ}C$ lower than those for HMA and therefore, the noxious gas emission were significantly reduced. The field density of WMA pavements was similar or better than that of HMA pavement. From the laboratory testings, it was found that WMA mixtures exhibit comparable performance to HMA mixture in moisture susceptibility, permanent deformation, and fatigue performance. CONCLUSIONS : With these results, it would be concluded that WMA could replace the existing HMA technology without any significant issue. To support this conclusion, it is necessary to track the long-term performance of WMA in pilot road.

연약지반에 대한 더치콘과 피에조콘 관입시험 비교 연구 (Comparative Study of Dutch Cone and Piezocone Penetration Test on Soft Ground)

  • 원정윤;장병욱;우철웅;윤상묵
    • 한국농공학회지
    • /
    • 제45권2호
    • /
    • pp.96-106
    • /
    • 2003
  • 134 Dutch cone (mechanical cone) and 9 piezocone (electronic cone) penetration tests have been performed in the southwestern part of Korea. In general, Dutch cone results may be different from that of piezocone due to the difference in structure of the cones. 6 Dutch cone and piezocone test data which were obtained at the same point respectively, were analyzed and plotted in soil classification chart proposed by Robertson et. al.(1986, 1990). Cone factors of Dutch cone and piezocone test empirically have been determined using laboratory and field vane test results. Using this cone factors, it was shown that there was good correlation between shear strength estimated using cone resistance and that of laboratory test and field vane tests. It was found that there was a good correlation between cone resistance from Dutch cone and that from piezocone. Relationship formula was also suggested. Dutch cone test provides a useful means for stratigraphic profiling in large project and has some advantage over piezocone in particular situations, such as very soft clay ground and dredged area.

CAC를 이용한 긴급도로 보수재의 현장 적용성 (Field Applicability Of Emergency Road Repair Material Using the CAC)

  • 현지수;김진만;최홍범;이하나;구자술
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.154-155
    • /
    • 2015
  • This study was to review the basic characteristics in order to evaluate field application of the emergency road repair materials for development of CAC(Calcium Aluminate Composite) usage. The experiment was conducted with two phases of field and laboratory conditions and the laboratory experiment consisted indoor and outdoor tests for compressive and flexural strength. In the result of an experiment, for the compressive strength test, the specimens that cured in the laboratory conditions were not satisfied the requirement of standards, while the specimens that cured in the field conditions were well satisfied with those. For flexural strength test, the result value was satisfied with the requirement on the standards only in outdoor curing condition of laboratory experiment. Based on these results, it is expected that the CAC can be used as an emergency road repair material for field conditions.

  • PDF

국내 현장가열재생아스팔트 시공 혼합물 시험평가 (A Case Study of Hot In-Place Recycling Asphalt Mixture in Korea)

  • 권수안;양성린;이재준;홍재청;임재규
    • 한국도로학회논문집
    • /
    • 제15권1호
    • /
    • pp.57-63
    • /
    • 2013
  • PURPOSES: This study is to investigate the Hot In-Place recycling asphalt mixture in Korea using field produced materials. METHODS: Hot In-Place reclaimed asphalt mixture was investigated to evaluate the mixture properties based on various test results such as Marshall Test, Indirect Tensile Test, TSR, and Wheel Tracking Test. These test values were compared with domestic standard specification. RESULTS: The result of the laboratory experiment indicates that the Hot In-Place Reclaimed(HIR) asphalt mixture produced at the field constrution site was satisfied all of the test criteria such as Indirect tensile test, Marshall and TSR test, and wheel tracking test. During the test, the research team found that current HIR system is required an extention of mixing time to improve quality and to reduce variation of sample to sample. Although the current HIR mixture was passed the test criteria, there is a potential capability to enhance the mixture properties as extend mixting time. CONCLUSIONS: Based on these laboratory test results, It would be concluded that domestic HIR mixture's properties were satisfied all standard specification related with evaluation of recycling asphalt mixtures. Based on this case study result, there is a chance to save construction cost and increase the usage of reclaimed asphalt concrete in the future.

모래 치환법을 이용한 흙의 밀도 시험에 관한 고찰 (Evaluation of Sand-Cone Method for Determination of Density of Soil)

  • 박성식;최현석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.23-29
    • /
    • 2009
  • A sand-cone method is commonly used to determine the density of the compacted soils. This method uses a calibration container to determine the bulk-density of the sand for use in the test. The density of the test or compacted soil is computed on the assumption that the calibration container has approximately the same size or volume and allows the sand to fall approximately the same height as a test hole in the field. However, in most cases the size or shape of test hole is not exactly the same as the calibration container. There is certain discrepancy between sand particle settlement or arrangement in the laboratory calibration and in the field testing, which may cause an erroneous determination of in-situ density. The sand filling process is simulated in the laboratory and its effect on the determination of density is investigated. Artificially-made holes with different heights and bottom shapes are prepared to simulate various shapes of the test hole in the field. The sands with different gradations are used in the testing to examine how sand grain size influences the determination of density in the field.

  • PDF

FIELD DATA를 이용한 진동시험 규격화 방안 (Packaging Vibration Specification Based on Field Data)

  • 김응주;이수근
    • 한국포장학회지
    • /
    • 제4권2호
    • /
    • pp.39-44
    • /
    • 1998
  • We used recording device(EDR-3) to monitor the packages and the vehicle during shipment. Provided we did this enough times, we began to gain statistically valid information which could be used to describe the particular channel of distribution. The event was obviously changed from trip to trip, but in general we could have an idea of what to expect. Considerable amount of time and money were invested to record field data. Although not ideal, it was the best suited approach to gain information regarding a specific distribution channel. Based on the recorded field data, we could make our own packaging vibration testing specification through MIL-STD-810D(Guidance for development of laboratory dynamic test specification). This test specification was proved several times through field tests. As a result, we gained confidence in this revised vibration specification and come to know the development procedures of a laboratory dynamic test specification.

  • PDF

현장인발시험을 통한 섬유형 쏘일네일의 거동특성 평가 (Evaluation of Behavior Characteristics of Geosynthetic Fiber Nail System from the Field Pull-Out Tests)

  • 김홍택;박시삼;조병국;정성필
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.342-347
    • /
    • 2004
  • Excavation nearby the existing structures is being performed vigorously to get the greatest use of land along with fast economic growth in the downtown area. The application of soil nailing system gradually increases because of an advantage of soil nailing system adjacently constructed in the existing structures. In this study, friction resistance by pull-out is considered as main resistance except resistance formed by flexural rigidity of nail observing that resistance of flexural rigidity is about $0{\sim}15\;%$ of whole safety factor according to degree of flexural rigidity in general soil nail wall and application of geosynthetic fiber soil nailing system is evaluated through laboratory tensile strength test and field pull-out test.

  • PDF

개인용 혈당측정기의 신뢰성 보증시험 개발 (Development of Reliability Demonstration Test for Personal Blood Glucose Meters)

  • 김기영;박호준;박찬수;함중걸;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제13권4호
    • /
    • pp.299-307
    • /
    • 2013
  • The value of blood sugar is measured by a personal blood glucose meter which consists of two parts: a glucose strip and a blood glucose meter. A personal blood glucose meter makes use of electric media which are composed of glucose oxidase and electron. This study is to propose a method of reliability demonstration test derived from field data analysis and FMEA(Failure Mode and Effect Analysis). Detailed Conditions for reliability demonstration test are selected from the comparison of various failure mechanisms. The most dominant failure mechanism is wear-out which is caused by strip insertion/extraction. The testing device that can reproduce the failure mechanism of strip insertion/extraction is made to conduct reliability demonstration test. Using the testing device, it is confirmed that target lifetime of selected devices is more than 2 years.