• Title/Summary/Keyword: Laboratory Chamber test

Search Result 100, Processing Time 0.027 seconds

A Laboratory Study on Low Frequency Noise Assessment based on Noise Acceptability Limits (소음 수응 한계(Noise Acceptability Limits)를 고려한 저주파 소음평가에 대한 실험적 연구)

  • Hong, Seung-Ki;Kim, Jae-Hwan;Kim, Kyu-Tae;Lee, Soo-Gab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.127-131
    • /
    • 2007
  • A laboratory study on low frequency noise assessment was carried out to determine the acceptability limits in the frequency range between 20 and 200 Hz. The acceptability limits were tested in the anechoic chamber to minimize the background noise. A total of 30 test subjects, who were aged between 19 to 33 years, participated in this study. They were exposed to various stimuli for about 1 hour by supra-aural earphone. The experiment consisted of two listening sessions; hearing threshold and the acceptability limits session. The results showed that the trend of the acceptability limits curve was approximately equal to C-weighting curve which had been found to be superior to A-weighting curve in low frequency noise assessment.

  • PDF

A Low-Cost Method to Evaluate Absorber Reflectivity Using an Antenna with a Small Radiating Aperture and Frequency-Domain Instrument

  • Oh, Soon-Soo;Lee, Young Hwan
    • ETRI Journal
    • /
    • v.35 no.6
    • /
    • pp.1148-1151
    • /
    • 2013
  • We propose a way to measure the absorber reflectivity at a low cost. Only one simple antenna with a small radiating aperture and a frequency-domain instrument are utilized. The previously used equation for calculating the reflectivity of an absorber is inaccurate, and, therefore, a new equation is derived based on multiple reflection analysis and three test models. Notably, the reflection coefficient of the antenna is included in the derived equation. The accuracy of the proposed method is proven through simulation and measurements. It can be easily applied to a product examination by absorber manufacturers and customers owing to its advantages of simplicity, cost effectiveness, and non-cutting examination.

Repellency test of aroma insect repellent against insect vectors (아로마 해충기피제의 기피력 테스트)

  • 이종권;윤화경
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.4
    • /
    • pp.279-281
    • /
    • 2004
  • The pulp fabric impregnanted 100% natural insect repellent was evaluated in an environmental chamber (laboratory, mongsanpoo beach, taejo Mt, naksan and seolak beach) for their repellent efficacy against insects. The results showed significant average repellency of 91%, 78%, 90%, and 93% of laboratory, mongsanpoo beach, taejo Mt, naksan and seolak beach, respectively, during the 1hour of exposure period.

  • PDF

Corrosion Performance of Cu Bonded Grounding-Electrode by Accelerated Corrosion Test

  • Choi, Sun Kyu;Kim, Kyung Chul
    • Corrosion Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.211-217
    • /
    • 2018
  • Natural degradation of grounding-electrode in soil environment should be monitored for several decades to predict the lifetime of the grounding electrode for efficient application and management. However, long-term studies for such electrodes have many practical limitations. The conventional accelerated corrosion test is unsuitable for such studies because simulated soil corrosion process cannot represent the actual soil environment. A preliminary experiment of accelerated corrosion test was conducted using existing test standards. The accelerated corrosion test that reflects the actual soil environment has been developed to evaluate corrosion performances of grounding-electrodes in a short period. Several test conditions with different chamber temperatures and salt spray were used to imitate actual field conditions based on ASTM B162, ASTM B117, and ISO 14993 standards. Accelerated degradation specimens of copper-bonded electrodes were made by the facile method and their corrosion performances were investigated. Their corrosion rates were calculated to $0.042{\mu}m/day$, $0.316{\mu}m/day$, and $0.11{\mu}m/day$, respectively. These results indicate that accelerated deterioration of grounding materials can be determined in a short period by using cyclic test condition with salt spray temperature of $50^{\circ}C$.

Measurement of Small-Strain Shear Modulus Using Pressuremeter Test (공내재하시험기를 이용한 미소변형 전단탄성계수 측정)

  • Kim, Dong-Su;Park, Jae-Yeong;Lee, Won-Taek
    • Geotechnical Engineering
    • /
    • v.13 no.4
    • /
    • pp.109-120
    • /
    • 1997
  • In the working stress conditions, the strain level in a soil mass experienced by existing structures and during construction is less than about 0.1-1%. In order to analyse the deformational behavior accurately, the in-situ testing technique which provides the reliable deformational characteristics at small strains, needs to be developed. The purpose of this paper is to measure the small-strain shear modulus of soils by using pressuremeter test(PMT). PMT is a unique method for assessing directly the in-situ shear modulus of soils with strain amplitude. For the accurate small strain measurements without initial disturbance effect, the unloading-reloading cycle was used and the measured modulus was corrected in view of the relevant stress and strain levels around the PMT probe during testing. Not only in the calibration chamber but in the field, PMT tests were performed on the cohesionless soils. The variation in shear modulus with strain amplitude ranging from 10-2% to 0.5% was reliably determined by PMT PMT results were also compared with other in-situ and laboratory test results. Moduli obtained from different testing techniques matched very well if the effect of strain amplitude was considered in the com pall son.

  • PDF

LCD Cell Aging Tester

  • Son, Hyuk;Baek, Sung-Sik;Oh, Hyeong-Geun;Choi, Byoung-Deog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1383-1385
    • /
    • 2009
  • This paper suggests that testing method and equipment structure to detect potential failures of LCD cells. LCD Cell Aging Tester is the unique process to detect failures related with ASG circuits. This system consists of four components that is Aging chamber, work table, probe contact unit, and pattern generator. The key factor of the concept is temperature aging and HVS driving. Complicated combination of test parameters including voltage, temperature and frequency provided practical burn-in conditions eligible for prediction of mass production.

  • PDF

Analytical method for analyzing formaldehyde using 2, 4-DNPH and gas chromatography/FID, NPD (2,4-DNPH와 가스크로마토그래프를 이용한 포름알데히드 분석방법)

  • Jeong, Jee Yeon;Park, Seung Hyun;Yi, Gwang Yong;Oh, Se Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.126-146
    • /
    • 2000
  • To develop and evaluate formaldehyde measurement method using 2,4-dinitro-phenylhydrazine (2,4-DNPH) coated sampler and gas chromatography, laboratory test and field test were conducted. Results of this study are as follows. Limit of detection(LOD) of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is $0.008{\mu}g/m{\ell}$ $0.060{\mu}g/m{\ell}$, $0.472{\mu}g/m{\ell}$ respectively. Coefficiency of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is 0.008, 0.009, 0.020 respectively. Desorption efficiency of sep-pak xposure aldehyde sampler and sorbent sample tube is 1.05(range : 0.99 - 1.12), 1.02(range : 0.99 - 1.06) respectively. Samples of sorbent sample tube and sep-pak xposure aldehyde sampler turned out to be stored at refrigerator, according to storage test results. Measurement methods of HPLC-UVD, GC-NPD, GC-FID, according to results of precision for the combined sampling and analytical procedure, became acceptable to OSHA evaluation standard. Field test using exposure chamber met the NIOSH overall uncertainty recommendation(less than 25%). Overall uncertainty of Sepak-HPLC(UVD), Tube-GC(NPD), Tube-GC(FID) is 11.0% - 17.0%. Consequently gas chromatography(GC-NPD, GC-FID) and high performance liquid chromatography(EPA TO-11) using 2,4-DNPH coated sampler for formaldehyde measurement turned out to be suitable to measure personal formaldehyde exposure at workplaces.

  • PDF

Effect of Fabrication Methods on Static Strength of Polymer Based Composites under the Low Temperature Range (적층 방법에 따른 복합재의 저온 영역 하에서 정적 강도 변화)

  • Eom, Su-Hyeon;Dutta, Piyush K.;Gwon, Sun-Cheol;Kim, Guk-Jin;Kim, Yun-Hae
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.7-12
    • /
    • 2003
  • When the wind turbine is used in cold regions, the mechanical properties and dimension stability of the blade will be changed. The proposal of this paper is to test the durability of the blade for wind turbine. It is necessary to select the most comfortable materials and fabrication processes for more stable wind turbine blade in cold regions. To select the most comfortable materials and processes, the static strength has to know through the tensile static tests at the severe condition as cold regions. First, the tensile static specimens made by RIM (Resin injection molding) process & vacuum bagging process with reinforcement materials and resin. Tensile static tests were carried out on three laminate lay-ups (carbon prepreg, carbon fiber dry fabric and glass fiber dry fabric) at different test temperature($24^{\circ}$, $-30^{\circ}$), determining properties such as the mechanical strength, stiffness and strain to failure. At different test temperature, in order to test the tensile strengths of these specimens used the low temperature chamber. Next, the results of this test were compared with each other. Finally, the most comfortable materials and fabrication processes can select based on these results. The results show the changes in the static behavior of three laminate lay-ups at different test temperatures. At low temperatures, the static strengths are higher than the ones at room temperature.

  • PDF

Vacuum Characteristics of KSTAR ICRF Antenna during RF Operation (고주파 인가시의 KSTAR ICRF 안테나의 진공특성)

  • Bae, Young-Dug;Kwak, Jong-Gu;Hong, Bong-Geon
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.314-324
    • /
    • 2006
  • The vacuum characteristics of the KSTAR ICRF antenna were experimentally investigated. The fabricated antenna was installed in the RF Test Chamber(RFTC) which has a vacuum system with an effective pumping speed of 1015 l/s. The time variations of RFTC pressure, total gas load and ultimate pressure were measured before the RF test. RF conditioning effect was studied by repeating RF pulses at low power level. A time variation of the RFTC pressure was measured during a RF power was applied to the antenna. Threshold pressure at which a RF breakdown occurs was investigated. Whenever the pressure was higher than $10^{-4}$ mbar, the RF breakdown occurred. During a long pulse testing, the temperature of the antenna and RFTC pressure were measured to investigate long pulse limitation of the maximum available voltage without any cooling, which were compared with testing results with a water cooling of the antenna.

Effects of Vacuum Pressure in The Laboratory Horizontal Drain Test for Dredged Clay (준설매립토에 대한 실내 수평배수재 실험에서 진공압의 효과)

  • Yang, Won-June;Jang, Yeon-Soo;Park, Jung-Yong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.1
    • /
    • pp.17-25
    • /
    • 2004
  • A horizontal drain method, which applies vacuum pressure at the end of a horizontal drain for discharging pore water, is used often for improving surface reclaimed clay in the field. In this study, to examine the effectiveness of improving consolidation or shear strength depends by varying vacuum pressure, laboratory chamber horizontal drain test using vacuum pressure is performed and the results is compared with that of self-weight consolidation. The results show that water content reduces with the increase of soil depth in case of self-weight consolidation, while it reduces near the horizontal drain and increases with the increase of the distance from the horizontal drain in case of applying vacuum pressure. The shear strength of dredged soil was improved as well, when the vacuum pressure is applied. The optimized consolidation was achieved at the vacuum pressure range of 30 to 50kPa in the laboratory box test of 50cm wide, considering the range of drain interval in the field was between 0.7 and 1.2m.

  • PDF