• Title/Summary/Keyword: LabView control system

Search Result 164, Processing Time 0.019 seconds

Greenhouse Control with PV System

  • Kim, Kee Hwan
    • International Journal of Advanced Culture Technology
    • /
    • v.1 no.1
    • /
    • pp.6-10
    • /
    • 2013
  • The greenhouse control system for educational purpose is designed by personal computer. This system should observe and control the growth conditions for crops in both plastic film and glass greenhouses. In this contribution puts emphasis on construction of greenhouse control system by personal computer under the aim of creating safer, more effective and more economical services. This system is developed for the requirements of the intelligent greenhouse control system and is powered by solar energy. A photovoltaic system with sun tracking module is used for the greenhouse control system.

  • PDF

Development of an Embedded Solar Tracker using LabVIEW (LabVIEW 적용 임베디드 태양추적장치 개발)

  • Oh, Seung-Jin;Lee, Yoon-Joon;Kim, Nam-Jin;Oh, Won-Jong;Chun, Won-Gee
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.128-135
    • /
    • 2010
  • This paper introduces step by step procedures for the fabrication and operation of an embedded solar tracker. The system presented consists of application software, compactRIO, C-series interface module, analogue input module, step drive, step motor, feedback devices and other accessories to support its functional stability. CompactRIO that has a real-tim processor allows the solar tracker to be a stand-alone real time system which operates automatically without any external control. An astronomical method and an optical method were used for a high-precision solar tracker. CdS sensors are used to constantly generate feedback signals to the controller, which allow a solar tracker to track the sun even under adverse conditions. The database of solar position and sunrise and sunset time was compared with those of those of the Astronomical Applications Department of the U.S. Naval Observatory. The results presented here clearly demonstrate the high-accuracy of the present system in solar tracking, which are applicable to many existing solar systems.

Development of LabVIEW-based Data Storage and Monitoring Program for a Condensed Hydrogen Liquefaction System (응축형 수소 액화 시스템에 대한 LabVIEW 기반 데이터 저장 및 모니터링 프로그램 개발)

  • DONG WOO HA;HYUN WOO NOH;YOUNG MIN SEO;TAE HYUNG KOO;ROCK KIL KO
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.5
    • /
    • pp.456-464
    • /
    • 2023
  • In this study, a compact hydrogen liquefaction system was constructed with the aim of creating a data storage and monitoring program for liquid hydrogen production. This program was designed to receive and record signals from diverse control equipment through the LabVIEW software. A range of measurement instruments were devised to collect data, encompassing variables such as flow rate, pressure, temperature, and liquid level. As a result, it was possible to directly check the production of liquid hydrogen by obtaining various data of condensed liquid hydrogen. In addition, it was confirmed that long-term storage of liquid hydrogen is possible by developing automatic ON/OFF through the LabVIEW program.

Feasibility Study of Data Acquisition System based on Oscilloscope for Radiation Detector (방사선 검출기용 데이터획득장치로서의 오실로스코프 활용 가능성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1804-1809
    • /
    • 2017
  • A data acquisition (DAQ) system based on oscilloscope was developed and evaluated for radiation detector. The dedicated LabVIEW program that perform the oscilloscope control and the data process was developed. Triggered events for each analog channel were acquired and the output signals were subsequently digitized and recorded for offline processing. Radiation pulse generation circuit was developed to evaluate the intrinsic characteristics of DAQ system. Energy linearity and energy resolution performances were assessed by voltage-peak channels and FWHM obtained from Gaussian fit, respectively. Radiation detector consists of LYSO and GAPD array. The 16 output signals were multiplexed by the RCD networks, and they were fed into the custom-made preamplifiers. Voltage-peak channels was linearly changed as a function of input voltage and the estimated coefficient of determination ($R^2$) was 0.999. No considerable changes in voltage resolution were observed. All 16 crystals were clearly identifiable on the resulting flood image and the mean energy resolution was ~15.1%. This study demonstrated that it is feasible to develop the DAQ system based on oscilloscope and LabVIEW program for radiation detector and the proposed approach offers opportunities to build simple DAQ system in various radiation measurement field.

Air detector using the change of dielectric constant for medical applications (의료분야 응용을 위한 유전상수 변화를 이용한 공기감지 장치)

  • Kim, Kyung-Hwa;Shim, Joon-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.864-870
    • /
    • 2010
  • Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity. To solve the problem, we developed the air detector using relative dielectric constant change, which is expected to be used broadly in industrial circles. We designed air detection system with air control equipment, detection circuit and LabVIEW system for air sensing. In experiments with a mock system, the proposed system showed a signal difference depending on the amount of air in the Tygon tube of the mock system.

Development of LabVIEW Program for Lock-In Infrared Thermography (위상잠금 열화상장치 제어용 랩뷰 프로그램 개발)

  • Min, Tae-Hoon;Na, Hyung-Chul;Kim, Noh-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.127-133
    • /
    • 2011
  • A LabVIEW program has been developed together with simple infrared thermography(IRT) system to control the lock-in conditions of the system efficiently. The IR imaging software was designed to operate both of infrared camera and halogen lamp by synchronizing them with periodic sine signal based on thyristor(SCR) circuits. LabVIEW software was programmed to provide users with screen-menu functions by which it can change the period and energy of heat source, operate the camera to acquire image, and monitor the state of the system on the computer screen. In experiment, lock-in IR image for a specimen with artificial hole defects was obtained by the developed IRT system and compared with optical image.

A Study on Manufacture and Control of a Self Manufacturing Hybrid Electric Vehicle (자작형 하이브리드카의 제작 및 제어에 관한 연구)

  • Kim, Hack-Sun;Jeong, Chan-Se;Yang, Soon-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.8-13
    • /
    • 2012
  • In this paper, Hybrid Electric Vehicle is directly designed and manufactured for base study of HEV's system and Green Car. Foundation design consists of power train design and the frame design. The power train concept includes motor, engine, generator and battery. And the concept of the frame is the single-seat of this self-made HEV. A frame installed in hybrid system contains suspension, steering wheel, seat, accelerating pedal, brake pedal, clutch handle and various chassis parts with bearings. Electromagnetic clutch is equipped to transmit engine power to drive axle. The control algorism make using LabVIEW to control of an engine and a motor depending on drive condition. A parallel type hybrid system is manufactured to control operation of a motor and an engine depending on vehicle speed.

Development and Flight Test of Unmanned Autonomous Rotor Navigation System Based on Virtual Instrumentation Platform (Virtual Instrumentation 플랫폼 기반 무인 자율 로터 항법시스템 개발 및 비행시험)

  • Lee, Byoung-Jin;Park, Sang-Jun;Lee, Seung-Jun;Kim, Chang-Joo;Lee, Young-Jae;Sung, Sang-Kyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.8
    • /
    • pp.833-842
    • /
    • 2011
  • The objectives of this research are development of guidance, navigation and control system for RUAV on virtual instrumentation and real flight test. For this research, the system is divided to DAQ (data acquisition) section, actuator section and controller section. And the hardware and software on each sections are realized on LabVIEW base. Waypoint guidance and control of auto flight are realized using PID gain tuning and waypoint vector tracking guidance algorism. For safe flight test, auto/manual switching module isolated from FCS (Flight Control System) is developed. By using the switch module, swift mode change was achieved during emergency flight case. Consequently, a meter level error of flight performance is achieved.

Advanced measurement system of amperometry and temperature monitoring by using LabVIEW (LabVIEW를 이용한 Amperometry 측정 정밀도 개선과 측정시간 단축 및 실시간 온도 측겅시스템 구성)

  • Choi, Myung-Ki;Park, Jung-Il;Pak, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.144-145
    • /
    • 2007
  • 본 논문은 LabVIEW를 이용하여 온도측정과 amperometry 측정을 동시에 하며, amperometry 측정오차와 구동전압의 세팅 시간을 줄일 수 있는 시스템을 설계한 내용을 담고 있다. Amperometry는 구동전압을 인가하여, 전류를 측정하는 방법인데, 정확한 측정을 위해서는 구동전압을 균일하게 인가해야 한다. 또한 바이오 분야에서의 amperometry 측정은 온도에 따라 측정 결과가 다르게 나타날 수 있기 때문에 온도의 측정과 amperometry 측정이 동시에 이루어져야 측정오차를 줄일 수 있다. 본 논문에서는 이상(異常) 구동전압의 배제 알고리즘을 통하여 전류측정의 오차를 ${\pm}$70pA에서 ${\pm}$50pA이내로 줄였으며, proportional control을 응용한 알고리즘을 사용하여 307초의 측정시간을 105초로 단축하였다. 또한 amperometry 측정 과정에서 온도를 실시간으로 측정함으로써 측정상태를 보다 정확히 파악하는 시스템을 구성하였다.

  • PDF

A Study on Robot Arm Control System using Detection of Foot Movement (발 움직임 검출을 통한 로봇 팔 제어에 관한 연구)

  • Ji, H.;Lee, D.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.1
    • /
    • pp.67-72
    • /
    • 2015
  • The system for controlling the robotic arm through the foot motion detection was implemented for the disabled who not free to use of the arm. In order to get an image on foot movement, two cameras were setup in front of both foot. After defining multiple regions of interest by using LabView-based Vision Assistant from acquired images, we could detect foot movement based on left/right and up/down edge detection within the left/right image area. After transferring control data which was obtained according to left/right and up/down edge detection numbers from two foot images of left/right sides through serial communication, control system was implemented to control 6-joint robotic arm into up/down and left/right direction by foot. As a result of experiment, we was able to get within 0.5 second reaction time and operational recognition rate of more 88%.

  • PDF