• Title/Summary/Keyword: Lab. Test

Search Result 1,788, Processing Time 0.029 seconds

Development of Proportional Valve Actuator Controller for Industrial Site (산업용 밸브 액추에이터 비례제어 컨트롤러 개발)

  • Park, Han Young;Kim, Jin Young;Ahn, Sung Soo;Kang, Joonhee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.269-274
    • /
    • 2013
  • To proportionally control the electronic valve position of the actuator, we designed and fabricated PCU, CPT, and rotary absolute optical encoder for the detection of absolute angular position in the actuator. We also designed and constructed the test system by using DAQ hardware and Labview. We designed PCU to convert 1-5 V, 0-5 V, 0-10 V, 2-10 V voltage signals and 4-20 mA current signals to the voltage signals in the common 0.5-2.5 V range. We designed CPT to output 4-20 mA current signals corresponding to the valve positions based on the PWM signal input from the MCU. We also designed 20 bit optical encoder by using infrared LED and infrared transistor and made the serial communication with the main board possible. When we tested PCU and CPT with DAQ hardware and Labview software, they operated correctly with the small errors within ${\pm}0.003$ V and ${\pm}0.01$ mA, respectively, showing that our actuator has the excellent performance to employ as the industrial proportional-valve-actuator. The resolution of the encoder was $11.25^{\circ}$ and the maximum revolution to detect was 32,768.

Development of Automatic Sorting System for Black Plastics Using Laser Induced Breakdown Spectroscopy (LIBS) (LIBS를 이용한 흑색 플라스틱의 자동선별 시스템 개발)

  • Park, Eun Kyu;Jung, Bam Bit;Choi, Woo Zin;Oh, Sung Kwun
    • Resources Recycling
    • /
    • v.26 no.6
    • /
    • pp.73-83
    • /
    • 2017
  • Used small household appliances have a wide variety of product types and component materials, and contain high percentage of black plastics. However, they are not being recycled efficiently as conventional sensors such as near-infrared ray (NIR), etc. are not able to detect black plastic by types. In the present study, an automatic sorting system was developed based on laser-induced breakdown spectroscopy (LIBS) to promote the recycling of waste plastics. The system we developed mainly consists of sample feeder, automatic position recognition system, LIBS device, separator and control unit. By applying laser pulse on the target sample, characteristic spectral data can be obtained and analyzed by using CCD detectors. The obtained data was then treated by using a classifier, which was developed based on artificial intelligent algorithm. The separation tests on waste plastics also were carried out by using a lab-scale automatic sorting system and the test results will be discussed. The classification rate of the radial basis neural network (RBFNNs) classifier developed in this study was about > 97%. The recognition rate of the black plastic by types with the automatic sorting system was more than 94.0% and the sorting efficiency was more than 80.0%. Automatic sorting system based on LIBS technology is in its infant stage and it has a high potential for utilization in and outside Korea due to its excellent economic efficiency.

Charge-Discharge Characteristics of Lithium Metal Polymer Battery Adopting PVdF-HFP/(SiO2, TiO2) Polymer Electrolytes Prepared by Phase Inversion Technique (상반전 기법으로 제조한 PVdF-HFP/(SiO2, TiO2) 고분자 전해질을 채용한 리튬금속 고분자 2차전지의 충방전 특성)

  • Kim, Jin-Chul;Kim, Kwang-Man
    • Korean Chemical Engineering Research
    • /
    • v.46 no.1
    • /
    • pp.131-136
    • /
    • 2008
  • Silica- or titania-filled poly (vinylidene fluoride-co-hexafluoropropylene)-based polymer electrolytes were prepared by phase inversion technique using N-methyl-2-pyrrolidone and dimethyl acetamide as solvent and water as non-solvent. The polymer electrolytes were adopted to the lithium metal polymer battery using high-capacity cathode $Li[Ni_{0.15}Co_{0.10}Li_{0.20}Mn_{0.55}]O_2$ and lithium metal anode. After the repeated charge-discharge test for the cell, it was proved that the cell adopting the polymer electrolyte based on the phase-inversion membrane containing 40~50 wt% silica showed the highest discharge capacity (180 mAh/g) until 80th cycle and then abrupt capacity fade was just followed. The capacity fade might be due to the deposition of lithium dendrite on the polymer electrolyte, in which the capacity retention was no longer sustainable.

Performance Enhancement of Virtual War Field Simulator for Future Autonomous Unmanned System (미래 자율무인체계를 위한 가상 전장 환경 시뮬레이터 성능 개선)

  • Lee, Jun Pyo;Kim, Sang Hee;Park, Jin-Yang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.10
    • /
    • pp.109-119
    • /
    • 2013
  • An unmanned ground vehicle(UGV) today plays a significant role in both civilian and military areas. Predominantly these systems are used to replace humans in hazardous situations. To take unmanned ground vehicles systems to the next level and increase their capabilities and the range of missions they are able to perform in the combat field, new technologies are needed in the area of command and control. For this reason, we present war field simulator based on information fusion technology to efficiently control UGV. In this paper, we present the war field simulator which is made of critical components, that is, simulation controller, virtual image viewer, and remote control device to efficiently control UGV in the future combat fields. In our information fusion technology, improved methods of target detection, recognition, and location are proposed. In addition, time reduction method of target detection is also proposed. In the consequence of the operation test, we expect that our war field simulator based on information fusion technology plays an important role in the future military operation significantly.

The Difference of Efficacy for Oral Hypoglysemic Pharmacotherapy Based on Sasang Constitutional Medicine Among Type II Diabetes Mellitus Patients in Korea (제 2형 당뇨병 환자에서 사상체질에 따른 경구 혈당강하요법의 치료 반응성 및 사용 패턴 평가)

  • Kim, Ji Yeon;Lee, Myung Koo;Kim, Jung Tae;Lim, Sung Cil
    • YAKHAK HOEJI
    • /
    • v.58 no.1
    • /
    • pp.71-79
    • /
    • 2014
  • Although Korean patients with type 2 diabetes mellitus (T2DM) are generally treated by western medicine, many of them strongly believe in the traditional oriental Sasang constitutional classification and depend on it for food, health supplements, and oriental medicines decision making. Sasang constitutional classification is a part of traditional Korean medicine that divides people into four constitutional types (Tae-Yang: TY, Tae-Eum: TE, So-Yang: SY, and So-Eum: SE), which differ in inherited characteristics such as appearance, personality traits, susceptibility to diseases, and drug responses. It is recommended for T2DM patients to control their blood glucose very well from early stages with drugs and diet. However, many T2DM patients respond differently to their drugs, even though they receive the same medicine. Therefore, the present study investigated whether Sasang constitutional type can explain the therapeutic differences between oral hypoglycemic agents (OHAs) therapy (mono, dual and triple drug therapy). Patients of 618 with T2DM diagnosis and Sasang constitutional type known who received both western and oriental medicine treatment in a hospital between April 2006 and April 2013 retrospectively studied. HbA1c (%) and blood glucose (mg/dl) levels before OHAs therapy and 3 month after were collected for metformin (MET) or sulfonylurea (SU) monotherapy, MET+SU dual therapy, MET+except SU (where was either alpha-glucosidase inhibitor, dipeptidyl peptidase-4 inhibitor, meglitinide or thiazolidinedione) dual therapy, and triple therapy, according to Sasang constitutional type. For statistical analysis, ANOVA was used and paired t-test by SPSS 19.0 where P values less than 0.05 were considered statistically significant. Pattern was similar levels of HbA1c and blood glucose and which was decreased in order of mono, MET+SU dual, MET+except SU dual and triple therapy. In all patients comparison, for the So-yang (SY) constitutional type, either monotherapy was less effective; for Te-eum (TE) type, MET+SU dual therapy was less effective while MET+except SU dual therapy was more effective and the triple therapy was less effective; and for So-eum (SE) type, the triple therapy was more effective. For the management of TE type it is recommended to use drugs except SU when dual therapy is needed, restrict triple therapy and consider dual and insulin therapy; for SY type it is recommended to follow current guidelines; and for SE type it is advisable to skip dual therapy and start the triple therapy early. Finally, the therapeutic response to OHAs is different among Korean T2DM patients with different Sasang constitutional types. Taken together, the choice of effective OHAs therapy for each type is necessary in order to minimize the poor control of blood glucose level, the risk of complications, and the costs from a failure of therapy.

An Electrophysiologic Study on the Ulnar Digital Nerves (척골 지단 신경의 전기생리학적 연구)

  • Kim, Jong-Soon;Lee, Hyun-Ok;Ahn, So-Youn;Koo, Bong-Oh;Nam, Kun-Woo;Kim, Ho-Bong;Ryu, Jae-Kwan;Ryu, Jae-Moon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.11 no.2
    • /
    • pp.13-18
    • /
    • 2005
  • The ulnar nerve extends down the arm, across the elbow, and into the hand. It provides sensation to the little and ring fingers and activates many of the small muscles in the hand. The determination of peripheral nerve conduction velocity is an important part of ulnar nerve evaluation. The electrodiagnostic value as neurophysiologic investigative procedure has been known for many years but normal value of digital nerve was not reported in Korea. The purpose of this investigation was to measure the digital nerve conduction velocity of ulnar nerve for obtain clinically useful reference value and compare difference in each fingers and then compare with the other countries. 71 normal Korean volunteers (age, 19-65 years; 142 hands) examined who has no history of peripheral neuropathy, diabetic mellitus, chronic renal failure, endocrine disorders, anti-cancer medicine, anti-tubercle medicine, alcoholism, trauma, radiculopathy. Nicolet Viking II (EMG machine) was use for detected conduction velocity and amplitude of digital nerves in ulnar nerve. Data analysis was performed using SPSS. Descriptive analysis was used for obtain mean and standard deviation and independent t-test was used to compare with ring and little finger. Conduction velocity of the right ring finger was 57.44m/sec and little finger was 55.32msec. The left ring finger was 55.55msec and little finger was 54.11msec. Amplitude of the right ring finger was $30.28{\mu}V$ and little finger was $48.36{\mu}V$. The left ring finger was $30.67{\mu}V$ and little finger was $52.76{\mu}V$. There were significantly difference between ring and little in amplitude (p<.05) but there were no statistically difference between conduction velocity of ring and little finger (p>.05). The amplitude of little finger are greater than ring finger. The present results revealed that electodiagnosis can easily perform in little finger for digital nerve of ulnar nerve study.

  • PDF

Effect of metal conditioner on bonding of porcelain to cobalt-chromium alloy

  • Minesaki, Yoshito;Murahara, Sadaaki;Kajihara, Yutaro;Takenouchi, Yoshihisa;Tanaka, Takuo;Suzuki, Shiro;Minami, Hiroyuki
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the efficacy of two different metal conditioners for non-precious metal alloys for the bonding of porcelain to a cobalt-chromium (Co-Cr) alloy. MATERIALS AND METHODS. Disk-shaped specimens ($2.5{\times}10.0mm$) were cast with Co-Cr alloy and used as adherend materials. The bonding surfaces were polished with a 600-grid silicon carbide paper and airborne-particle abraded using $110{\mu}m$ alumina particles. Bonding specimens were fabricated by applying and firing either of the metal conditioners on the airborne-particle abraded surface, followed by firing porcelain into 5 mm in diameter and 3 mm in height. Specimens without metal conditioner were also fabricated. Shear bond strength for each group (n=8) were measured and compared (${\alpha}=.05$). Sectional view of bonding interface was observed by SEM. EDS analysis was performed to determine the chemical elements of metal conditioners and to determine the failure modes after shear test. RESULTS. There were significant differences among three groups, and two metal conditioner-applied groups showed significantly higher values compared to the non-metal conditioner group. The SEM observation of the sectional view at bonding interface revealed loose contact at porcelain-alloy surface for non-metal conditioner group, however, close contact at both alloy-metal conditioner and metal conditioner-porcelain interfaces for both metal conditioner-applied groups. All the specimens showed mixed failures. EDS analysis showed that one metal conditioner was Si-based material, and another was Ti-based material. Si-based metal conditioner showed higher bond strengths compared to the Ti-based metal conditioner, but exhibited more porous failure surface failure. CONCLUSION. Based on the results of this study, it can be stated that the application of metal conditioner is recommended for the bonding of porcelain to cobalt-chromium alloys.

Flow behavior characteristics according to superficial gas velocity of NiO/MoO3/MoS2 (NiO/MoO3/MoS2의 공탑속도에 따른 유동화 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Lee, Kwan-Young;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.79-85
    • /
    • 2017
  • This study identified the loss of minimum fluidization velocity and pressure in accordance with the superficial velocity of $NiO/MoO_3/MoS_2$, a rare metallic oxide and high value-added material in the lab-scale fluidized bed reactor (L=0.25 m, D=0.05 m). The average pressure loss in L/D 1, 2, and 3 of $NiO/MoO_3/MoS_2$ within the scope of superficial gas velocity between 0.07 and 0.45 m/s based on the L/D 1, 2, and 3 of the specimen was shown to be 290~1952 Pa at decreasing flux and 253~1925 Pa at increasing flux. The comparison between the theoretical value proposed by Wen and the test data showed a difference between 0.021~0.36 magnification. Based on these results, this study was able to determine the operation conditions where rare metallic oxides could be applied in real phenomena.

Estimation of PM2.5 Correction Factor for Optical Particle Counter in Ambient Air (대기환경에서 광산란 미세먼지 측정기의 PM2.5 보정계수 산정)

  • Kim, Jong Bum;Kim, Danbi;Noh, Sujin;Yoon, Kwan Hoon;Park, Duckshin;Lee, Jeong Joo;Kim, Jeongho
    • Particle and aerosol research
    • /
    • v.16 no.2
    • /
    • pp.49-59
    • /
    • 2020
  • Various devices have been developed to the measurement of particulate matter pollutants, and Optical Particle Counter (OPC) that can be easily and quickly measured is widely used lately. The measured value by OPC is converted to weight concentration using the correction factor (CF). The calculation of CF is very important to improve the reliability and accuracy of OPC. In this study, the CF calculation study of light scattering laser photometer (model 8533, TSI) was carried out to measure in the atmospheric environment using 2 gravimetric devices and 3 light scattering laser photometer devices. Regression analysis and Tukey tests were used to significance the test of measurement devices. Measurements were carried out twice. There was a comparative analysis of measurement data between light scattering laser photometer and gravimetric devices in 1st measurement, and then the Evaluation of PM2.5 concentration corrected by CF performed in 2nd measurement. As a result of the significance analysis between light scattering laser photometer and gravimetric devices, the correlation between the same method was high, but the correlation between different methods was low. CF was calculated as 0.4258 based on the measurement results, and it is a similar level to previous studies at home and abroad. It is expected that these results can be used as basic data in the future study for air quality measurement research using light scattering laser photometer. Also, in order to improve the accuracy of the measurement techniques and the development of technology in the atmospheric environment, CF calculation research should be conducted continuously.

Concentration of Polycyclic Aromatic Hydrocarbons in Cereals, Pulses, Potatoes, and their Products (곡류, 두류, 서류 및 그 가공품 중 다환 방향족 탄화수소 (polycyclic aromatic hydrocarbons) 화합물 함량)

  • Kim, Hee-Yun;Chung, So-Young;Sho, Yo-Sub;Park, Seong-Soo;Lee, Eun-Ju;Suh, Jung-Hyuk;Lee, Yun-Dong;Choi, Woo-Jeong;Kim, Jung-Soo;Eom, Ji-Yoon;Park, Hui-Og;Jin, Myeong-Sig;Kim, Dong-Sul;Ha, Sang-Chul;Lee, Jong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.537-541
    • /
    • 2005
  • Estimation of concentrations of PAHs [benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene, indeno(1,2,3-c,d)pyrene] in cereals, pulses, potatoes, and their products available in Korean markets gave mean levels of 0.13, 0.08, 0.06, 0.03, 0.08, 0.15, 0.45, and $0.14{\mu}g/kg$, respectively, with recoveries between 82.6-106.6%. Methodology involved saponification and extraction with n-hexane, purification on Sep-Pak Florisil cartridges, and high performance liquid chromatography using a fluorescence detector.