• Title/Summary/Keyword: LVDT sensor

Search Result 70, Processing Time 0.026 seconds

Development of Wireless Measurement System for Bridge Using PDA and Fiber Optical Sensor (PDA와 광섬유 센서를 이용한 교량의 무선계측 시스템 개발)

  • Kwak, Kae-Hwan;Hwang, Hae-Sung;Jang, Hwa-Sup;Kim, Woo-Jong;Kim, Hoi-OK
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.88-96
    • /
    • 2009
  • This study proposes a wireless measurement system that is a new safety management system by using an FBG sensor and a PDA. The sensor part has many advantages of implementing a wireless measurement system, and the study emploies an FBG-LVDT sensor, FBG-STRAIN sensor, FBG-TEMP sensor, and FBG-ACC sensor, using FBG sensors. Also, the study show a configuration of a signal process system for operating a wireless transmission system of FBG sensors applied to the signal process system, and engrafted the cutting edge information technology industry in order to display from a remote distance using a PDA. In order to verify the applicability of the developed FBG sensors and wireless measurement monitoring system to the field, their accuracy, and usability, the study has conducted a static and dynamic test to a bridge in the field. The study made an assessment of service for the vibration of the bridge by applying dynamic data measured by an FBG-LVDT sensor and FBG-ACC sensor to Meister's curve and prepared methods for assessing the vibration of the bridge by proposing a standard of vibration limitation given the service of vibration of the bridge. As a follow up for this study, it would be necessary to set up an overall model for the standard of service assessment established in this study.

Development of Contact-Type Thickness Measurement Machine using LVDT Sensors (LVDT센서를 이용한 접촉식 두께자동측정기 개발)

  • Shin, Ki-Yeol;Hwang, Seon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.4
    • /
    • pp.151-159
    • /
    • 2015
  • In this study, we developed an automated contact-type thickness measurement machine that continuously and precisely measures the thickness of a PCB module product using multi-LVDT sensors. The system contains a measurement part to automatically measure the thickness in real time according to the set conditions with an alignment supply unit and unloading unit to separate OK and NG products. The sensors were calibrated before assembly in the measuring machine, and precision and accuracy performance tests were also performed to reduce uncertainty errors in the measurement machine. In the calibration test, the precision errors of the LVDT sensor were determined to be $1-3{\mu}m$ as 0.1% at the measuring range. A measurement error of 0.8 mm and 1.0 mm thickness test standards were found to be $1{\mu}m$ and $4{\mu}m$, and the standard deviations of two 1.0 mm products were measured as $14{\mu}m$ and $8{\mu}m$, respectively. In the measurement system analysis, the accuracies of test PCB standards were found to be $2{\mu}m$ and $3{\mu}m$, respectively. From the results of gage repeatability and reproducibility (R & R) crossed, we found that the machine is suitable for the measurement and process control in the mass production line as 7.92% of total gage R & R and in seven distinct categories. The maximum operating speed was limited at 13 pcs/min, showing a value good enough to measure.

Development of LVDT-Based Measuring System of the Cylinder Liner Wear for Marine Diesel Engines and Its Performance Evaluation (LVDT를 이용한 선박용 디젤 엔진의 실린더 라이너 마모 계측시스템 개발 및 성능평가)

  • Ha, Yun-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.829-834
    • /
    • 2011
  • This paper introduces a new system which measures abrasion quantity of cylinder liners of large-scale marine diesel engines. The proposed system consists of three parts; measurement part where an LVDT, a temperature sensor, a camera and LED for lighting control are installed, monitoring part which accomplishes measurement command transmission and monitoring based on PC or notebook, and master control part which controls the measurement part and transfers measurement data to the monitoring part. The accuracy of the developed system is compared with that of an internal micrometer with 1/100 mm accuracy.

Feasibility Study of Structural Behavior Monitoring Using GPS and Accelerometer (GPS와 가속도계를 이용한 구조물 거동모니터링의 타당성 연구)

  • Han, Jung Hun;Ryu, Sung Chan;Cho, Doo Yong;Park, Sun Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.11-22
    • /
    • 2012
  • In this study, problems of RTK (Real Time Kinematic)-GPS (Global Positioning System) and an accelerometer sensor when applied to structures were experimentally identified through a comparison between results of the displacement measurement using the RTK-GPS, the accelerometer, and LVDT (Linear variable differential transformer). Integrated displacement was calculated by the improved RTK-GPS and accelerometer on the frequency of observation and positioning accuracy. This integrated displacement was also compared with that of LVDT to check the validity of application and feasibility.

Design of Capacitive Sensor for Measuring the Position of the Piston in Hydraulic Cylinder (유압 실린더 내 피스톤 위치측정을 위한 정전용량 센서 설계)

  • Lee, Soeng-hwi;Lee, Jae-gun;Kang, Yong-joo;Hong, Ic-pyo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.509-512
    • /
    • 2015
  • In this paper, several capacitive sensors for measuring the position of the piston in hydraulic cylinder was studied and designed. The inductive LVDT sensor has been widely used to measure the position of the piston because of its high accuracy, but this type of sensor is very expensive and has difficulty in use because of its complexity. To overcome these disadvantages, we studied the optimized non-contact capacitive sensors and designed several capacitive sensors for accurate measuring the location of piston in hydraulic cylinder. The proposed capacitive sensor has the possibility of practical use for hydraulic cylinder through experiments.

  • PDF

Development of 3-D. Displacement Measurement System for Critical Pipe of Fossil Power Plant (화력발전소 주배관 3차원 변위측정시스템 개발)

  • Song, G.W.;Hyun, J.S.;Ha, J.S.;Cho, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1198-1205
    • /
    • 2003
  • Most domestic fossil power plant have exceeded 100,000 hours of operation with the severe operating condition. Among the critical components of fossil power plant, high temperature steam pipe system have had a many problems and damage from unstable displacement behavior because of frequent start up and shut down. In order to prevent the serious damage and failure of the critical pipe system in fossil power plant, 3-dimensional displacement measurement system were developed for the on-line monitoring system. 3-D Measurement system was developed with using the LVDT type sensor and rotary encoder type sensor, this system was installed and operated on the real power plant successfully. In the future time, network system of on-line diagnosis for critical pipe will be designed.

  • PDF

A Study on the out-diameter measuring machine by the LVDT sensors (LVDT 센서를 이용한 외경 측정 방안에 대한 연구)

  • Hwang J.H.;Roh J.H.;Park Ki-Hong
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.291-292
    • /
    • 2006
  • Currently A demand of high precision workpiece is increasing in industry. At present, roundness measuring machine using Air bearing, coordinate measuring machine that are used from measurement station. but these machines will not be able to apply to In-line process. because of like these machine's price are very expensive and measurement time is long. also, the complexity of conventional roundness measurement method based on fourier transform, it makes difficult to development analysis program. This work present new architecture of a Out-diameter measuring system fur analysis of roundness of product. In this system, the influence of table motion errors is minimize by using two LVDT sensor and knife edge contact tip. We are produce a test machine and make an experimenter on Out-diameter of test bearing. The measurement result compared with roundness measuring machine.

  • PDF

A Study on Calibrations of health monitoring system installed in Railway bridge (철도교 상시계측시스템의 센서교정방안 연구)

  • Lee Hyun Suk;Lee Jun Suk;Choi Il Yoon;Yim Myoung Jae
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.483-488
    • /
    • 2003
  • Calibration and gauge factor readjustment process made for the health monitoring system installed in the railway bridges is reviewed and some findings are explained in this study: specifically, the calibrators made for this purpose are illustrated and the regression processes of the calibration on long-term displacement using water level sensor, longitudinal displacement using LVDT sensor, instantaneous displacement using LVDT sensors and accelerometer are described in details. Based on the regression results, new gauge factors are obtained from regression equation and another verification is made by performing another calibration again with new factors. From the second calibration, it was found that the suggested regression curves and their factors are appropriate and much better results are expected. Future work will be concentrated on the long-term analysis of the measurement data and on the database structures so that the assessment of the structure such as damage detection and remaining life estimation is possible.

  • PDF

Calibration of Health Monitoring System installed in the Railway Bridges (철도교 상시계측시스템의 교정 및 교정상수 설정에 관한 연구)

  • 박준오;이준석;최일윤;민경주
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.3
    • /
    • pp.148-157
    • /
    • 2002
  • A health monitoring system becomes a useful tool to obtain information on long term behavior of the important railway structures such as very long span and special type bridges. The health monitoring system not only gives the direct measurement data of the railway bridges but also provides the basic data on the maintenance of the structures. Therefore, periodic calibrations of the health monitoring system will be a necessary step toward precise and accurate assessment of the railway bridges. In this study, the calibration and gauge factor readjustment process made for the health monitoring system installed in the railroad bridges is reviewed and some findings are explained in detail: specifically, the calibrators made for this purpose are illustrated and the regression processes of the calibration on long-term displacement using water level sensor, longitudinal displacement using LVDT sensor, instantaneous displacement using LVDT sensors and accelerometer are described in full length. Based on the regression results, it was found that the gauge factors need to be readjusted according to the regression equation but, since the deviation or shift is not serious so far, long-term observation on each sensor is also recommended. Future work will be concentrated on the long-term analysis of each sensor and on the database creation so that the assessment of the structures is possible.

Development of the High_frequency and Low_strain Vibration Stimulation System for Stimulating Bone (고주파 저스트레인 골자극 인가용 진동 시스템 개발)

  • Yoo, Ju-Yeon;Park, Guen-Chul;Jeon, Ah-Young;Kim, Yun-Jin;Ro, Jung-Hoon;Jeon, Gye-Rok
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.177-184
    • /
    • 2011
  • In this study, the system for application of the bone stimulation was implemented using high frequency and low strain method. The whole system consists of the high frequency and low strain vibration stimulation system 177 for stimulating bone, LVDT sensor, and wireless sensor based on tri-axial accelerometer. To evaluate the usefulness of the system, the frequencies and accelerations from function generator were applied to the vibration stimulation system. The range of frequency was 17 Hz, 30 Hz, 45 Hz, 50 Hz and the range of acceleration was set 0.3 g, 0.6 g, 1g, and 2 g. The measured frequencies and acceleration using LVDT (linear variable difference transformer) sensor and 3-axial accelerometer were estimated and compared. The range of frequencies average difference was from 0.0 to 0.004 Hz. As the standard deviation of frequencies estimated by LVDT sensor and accelerometer was below 0.03 Hz and the output frequencies of function generator were similar: Also the results of t-test were satisfied with conditions of p > 0.05. And the acquired frequencies and acceleration from vibration measuring device module were estimated and analyzed. As the mean of accelerations was similar to the acceleration applied from function generator. And the standard deviation of acceleration estimated from vibration measuring device module was ranged from 0.019 g to 0.038 g. Also the results of t-test were satisfied with conditions of p > 0.05. Therefore, these results were airy similar to the acceleration applied from function generator. As a result, the usefulness of the system was confirmed. n a further study, clinical experiment will be carried out with the authorization of IRB (institutional review board) so that appropriate frequency and strain would be investigated in clinical field.