• Title/Summary/Keyword: LIF

Search Result 224, Processing Time 0.034 seconds

Hydroxyl Radical Measurements in the Flame Using LIF (레이저유도 형광법을 이용한 화염내 OH 농도분포 계측)

  • Lee, Byeong-Jun;Gil, Yong-Seok;Jeong, Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.2
    • /
    • pp.710-719
    • /
    • 1996
  • Laser applied combustion diagnostic techniques-laser induced fluorescence (LIF) and coherent anti-Stokes Ramann spectroscopy (CARS)-are demonstrated. The profiles of hydroxyl radical (OH) and temperature in the counterflow burner are measured and compared with the numerical results. OH radical is excited on the Q$_1$(6) line of the $A^2$$\sum^+$$\leftarrow$$X^2{\prod}$(1, 0) band transition (281.1 nm) and LIF signal is measured at the the bands of (0, 0) and (1, 1) transition (306~326 nm). Absolute OH radical is obtained by using the laser absorption technique. The quenching effects are considered. Temperature is measured using broadband CARS system. Two dimensional OH radical profile is also obtained. The profiles of OH radical and temperature are found to agree well with those of numerical calculation.

Quantitative Visualization of Oxygen Transfer in Micro-channel using Micro-LIF Technique (마이크로 레이저 형광 여기법을 이용한 미세채널 내부에서의 산소 확산에 대한 정량적 가시화)

  • Chen, Juan;Kim, Hyun-Dong;Kim, Kyung-Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.1
    • /
    • pp.34-39
    • /
    • 2012
  • In the present study, oxygen transfer process across gas-liquid interface in a Y-shape micro-channel is quantitatively visualized using the micro laser induced fluorescence (${\mu}$-LIF) technique. Diffusion coefficient of Oxygen ($D_L$) is estimated based on the experimental results and compared to its theoretical value. Tris ruthenium (II) chloride hexahydrate was used as the oxygen quenchable fluorescent dye. A light-emitting diode (LED) with wavelength of 450 nm was used as the light source and phosphorescence images of fluorescent dye were captured by a CMOS high speed camera installed on the microscope system. Water having dissolved oxygen (DO) value of 0% and pure oxygen gas were injected into the Y-shaped microchannel by using a double loading syringe pump. In-situ pixel-by-pixel calibration was carried out to obtain Stern-Volmer plots over whole flow field. Instantaneous DO concentration fields were successfully mapped according to Stern-Volmer plots and DL was calculated as $2.0675{\times}10^{-9}\;m^2/s$.

Flow Visualization of Flowfield Structures around an Aerospike Nozzle using LIF and PSP

  • NIIMI Tomohide;MORI Hideo;TANIGUCHI Mashio
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.75-80
    • /
    • 2004
  • Aerospike nozzles have been expected to be used for an engine of a reusable space shuttle to respond to growing demand for rocket-launching and its cost reduction. In this study, the flow field structures in any cross sections around clustered linear aerospike nozzles are visualized and analyzed, using laser induced fluorescence (LIF) of nitrogen monoxide seeded in the carrier gas of nitrogen. Since flow field structures are affected mainly by pressure ratio, the clustered linear aerospike nozzle is set inside a vacuum chamber to carry out the experiments in the wide range of pressure ratios from 75 to 200. Flow fields are visualized in several cross-sections, demonstrating the complicated three-dimensional flow field structures. Pressure sensitive paint (PSP) of PtTFPP bound by poly- IBM -co-TFEM is also applied to measurement of the complicated pressure distribution on the spike surface, and to verification of contribution of a truncation plane to the thrust. Finally, to examine the effect of the sidewalls attached to the aerospike nozzle, the flow fields around the nozzle with the sidewalls are compared with those without sidewalls.

  • PDF

Effect of GM-CSF on the Embryonic Development and the Expression of Implantation Related Genes of Mouse Embryos (Granulocyte-Macrophage Colony Stimulating Factor (GM-CSF)의 첨가가 생쥐 수정란의 발생과 착상관련 유전자 발현에 미치는 영향)

  • Kim, Dong-Hoon;Ko, Duck-Sung;Lee, Hoi-Chang;Lee, Ho-Joon;Kang, Hee-Gyoo;Kim, Tai-Jeon;Park, Won-Il;Kim, Seung-Samuel
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.29 no.2
    • /
    • pp.83-90
    • /
    • 2002
  • Objective : The purpose of the current series of experiments were to assess the effect of GM-CSF, as a medium supplement, on the development of mouse embryos and the expression of LIF and IL-1? mRNA. Materials and Methods: Mouse 2-cell embryos were collected from the oviducts of 6 weeks old ICR mice at 48 hours after hCG injection. Embryos were cultured in P-1 medium supplemented with mouse GM-CSF (0, 1, 5, 10 ng/ml). The embryo development to blastocysts and hatching blastocysts was assessed and the cell number in blastocyst was also examined. Using RT-PCR, the expressions of LIF and IL-1? mRNA in blastocyst were evaluated in the GM-CSF supplemented group and control group. Results: In mouse, the addition of GM-CSF increased the percentage of blastocysts (65.5%, 68.6%, 73.0% and 76.1% for control and 1, 5 and 10 ng/ml, respectively), and increased the proportion of hatching blastocysts (35.2%, 36.4%, 43.2% and 53.0% for control and 1, 5 and 10 ng/ml, respectively). The mean cell numbers in blastocyst were significantly increased in GM-CSF supplemented groups compared to control group. LIF and IL-1? expression in blastocyst were significantly higher in GM-CSF supplemented group than in control group. Conclusion: The results of experiment by mouse embryos showed beneficial effects of GM-CSF as a medium supplement. Furthermore, the addition of GM-CSF significantly increased the expression of LIF and IL-1? in mouse embryos. These results suggest that GM-CSF might be a important molecule in embryo implantation.

A Study on the Development of Measurement Techniques for Thermal Flows in MEMS

  • Ko Han-Seo;Yang Sang-Sik;Yoo Jai-Suk;Kim Hyun-Jung
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.387-395
    • /
    • 2006
  • A review on advanced flow visualization techniques is presented particularly for applications to micro scale heat and mass transport measurements. Challenges, development and applications of micro scale visualization techniques are discussed for the study of heating/evaporating thin films, a heated micro channel, and a thermopneumatic micro pump. The developed methods are (1) Molecular Tagging Fluorescence Velocimetry (MTFV) using 10-nm caged seeding molecules (2) Micro Particle Velocimetry (MPIV) and (3) Ratiometric Laser Induced Fluorescence (LIF) for micro-resolution thermometry. These three methods are totally non-intrusive techniques and would be useful to investigate the temperature and flow characteristics in MEMS. Each of these techniques is discussed in three-fold: (1) its operating principle and operation, (2) its application and measurement results, and (3) its future challenges.

Nanometer-Scale Surface Analysis of Polymers Using Laser Ablation Spectroscopy (레이저 애벌레이션 분광을 이용한 고분자 표면의 나노미터 스케일 표면 분석)

  • Kim, Min-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1334-1336
    • /
    • 2001
  • In this study, laser ablation atomic fluorescence (LAAF) spectroscopy has been applied for a nanometer-scale surface analysis of Na-doped polymethyl methacrylate (PMMA). LAAF spectroscopy is a new sensitive element detection technique which involves atomizing of a sample by the laser ablation and detection of ablated plume by laser-induced fluorescence (LIF) spectroscopy. Using this technique in the detection of Na atoms with Na-doped PMMA, a detection limit is obtained as 36 fg for single laser shot. Further, the depth distribution in the sample is measured with a very high spatial resolution using a two-layer PMMA sample by observing the shot-by-shot LIF intensity from the Na atoms.

  • PDF

A New Convolutional Weighting Function Method for Continuous-time Parameter Identification

  • Park, Hyun-Seob;Park, Poo-Gyeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.26.5-26
    • /
    • 2001
  • This paper proposes a new approach to identifying the unknown parameters of continuous LTI systems. For parameter identification in continuous-time systems, the Linear Integral Filter (LIF) method generally has been used in the beginning. Especially, one of the most efficient LIF methods in the literature is to use a weighting function satisfying specific three constraints. In high order systems, even though the weighting function satisfies the three constraints, it is impossible to identify the exact parameters of the systems because of information loss arising from a great amount of magnitude differences among the weighting function and its high-order derivatives. This paper, using an LMI technique, shows the limitation in designing the weighting function of the existing methods, and ...

  • PDF

Experimental Study on the Natural Convection in an Enclosure with an Adiabatic Body Using the Two-Color LIF Method (Two-color LIF 기법을 이용한 단열체가 있는 밀페계 내에서의 자연대류에 관한 실험적 연구)

  • Kwo S. H.;Jeong E. H.;Min Y. U.;Kim K. C.
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.90-96
    • /
    • 2005
  • Most of the previous studies on natural convection were based on the numerical analysis, and some experimental studies considered the classic case of thermal convection. In this study, an adiabatic square body was located at the center of an enclosure between the bottom hot and top cold walls. And the measurement of the detailed temperature fields was conducted by the method of two-color Laser Induced Fluorescence using a Nd:Yag laser. As a result, heat transfer characteristics of natural convection with an adiabatic body was estimated as a function of time over a range of Rayleigh numbers.

  • PDF