• Title/Summary/Keyword: LENGTH FREQUENCY

Search Result 3,083, Processing Time 0.031 seconds

Effects of Three Side Ratios of the Rectangular Substrate on the Resonant Characteristics of the Ultra-small Size Resonator Using Its Length Extensional Vibration (사각 기판의 길이진동을 이용하는 초소형 공진자에 있어서 사각 기판의 세변의 길이비가 공진특성에 미치는 영향)

  • 이개명;한성훈;김병효
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.11
    • /
    • pp.932-937
    • /
    • 2000
  • The length extensional vibration mode of a piezoelectric ceramic substrate is used in fabricating the ultra-small size resonators and filters. In general, the three side ratios of the rectangular substrate affect the resonant characteristics of the resonator using its length extensional vibration. In this paper, their relationships are studied. We know that changing the ratio of its length to its width makes possible to change the resonant frequency of the width vibration without degrading the length extensional vibration. And frequency constant for length extensional vibration becomes slightly small as the substrate thickness becomes thin, but it does not change as its length changes. Electro-mechanical coupling factor for length extensional vibration, k$\_$31/ does not change as its length changes within length/width$\geq$4, but it becomes small as its width increases.

  • PDF

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

An experimental study on the performance of inverter heat pump with a variation of frequency and capillary size (인버터 열펌프의 주파수 및 모세관 길이 변화에 따른 시스템 성능특성의 실험적 연구)

  • Choi, J.M.;Kim, Y.C.;Kim, J.Y.;Bae, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.64-72
    • /
    • 1997
  • An experiment study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4141W(3550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of 1000mm which was optimum size for the frequency of 60Hz and ARHRAE Test condition A was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycle was invesigated by varying the length of capillary tube at each frequency levels of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency levels. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher EER, while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

Analysis of Radio Frequency characteristics for Double Gate MOSFET (Double Gate MOSFET의 RF특성분석)

  • 김근호;고석웅;정학기
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.690-692
    • /
    • 2003
  • In this paper, we have investigated characteristics of radio frequency for double gate MOSFET with 50nm main gate in according to variation of side gate length. We could know the increasement of cut-off frequency as the side gate length is lower. As a result, we could know the most optimum performance characteristics when side gate length was 70nm. In this time, the DG MOSFET of side gate with 70nm has very high cut-off frequency like 41.4GHz.

  • PDF

Effect of Two-Frequency Forcing on Flow Behind a Backward-Facing Step (이중주파수 가진이 후향계단 유동에 미치는 영향)

  • Yu, Jeong-Yeol;Jin, Song-Wan;Kim, Seong-Uk;Choe, Hae-Cheon;Kim, Sa-Ryang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.423-431
    • /
    • 2002
  • An experimental study is conducted to investigate the effect of two-frequency forcing on turbulent flow behind a backward-facing step at the Reynolds number of 27000 based on the step height. The forcing is provided from a thin slit located at the edge of the backward-facing step to increase mixing behind the backward-facing step and consequently to reduce the reattachment length. With single frequency forcing, the minimum reattachment length is obtained at the non-dimensional forcing frequency (F) of St$\_$h/ = 0.29. With two-frequency forcing, a subharmonic frequency (F/2) or biharmonic frequency (2F) is combined with the fundamental frequency (F), i.e. (F, F/2) or (F, 2F) forcing is applied. In the case of (F, F/2) forcing, the reattachment length is not much sensitive to the phase difference between F and F/2. However, the reattachment length significantly depends on the phase difference between F and 2F in the case of (F, 2F) forcing. At a certain range of the phase difference, the reattachment length becomes smaller than that of the single frequency forcing.

Combustion Instability Comprehension with Combustion Chamber Length in Dual Swirl Gas Turbine Model Combustor from Flame Behaviors (화염거동을 통한 이중선회 가스터빈 모델 연소기에서 연소실 길이에 따른 연소 불안정성 이해)

  • Jang, Munseok;Lee, Keeman
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.233-235
    • /
    • 2015
  • This study is to investigate the combustion instability of the variation of combustion chamber length in dual swirl gas turbine model combustor. When equivalence ratio was fixed at 1.1, as the length of the combustion chamber increases the value of the frequency decreased in 7kW while the value of the frequency was constant in 4kW. The analysis of flame behaviors by high speed camera was conducted to identify such trend.

  • PDF

Length-dependent Staircase Phenomenon and Calcium Inotropisn in Isolated Rabbit Papillary Muscle (적출 유두근에서 근육길이에 따른 계단현상 및 칼슘 수축력의 변화)

  • Kim, Ki-Whan;Earm, Yung-E;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.14 no.2
    • /
    • pp.7-16
    • /
    • 1980
  • The effects of various inotropic interventions on the shape of the steady state length tension relation and the length-dependent activation process in cardiac muscle were studied. The influence of inotropic interventions upon the action potential was also observed. The range of varying muscle length was from the optimal length$(l_{max})$, where the active tension production is maximal, to 0.85 $l_{max}$. Changes in stimulus frequency or in external bathing Ca concentration constituted the inotropic interventions in this experiment. The papillary muscles were isolated from the rabbit right ventricles and perfused with $HCO-_3\;-buffered$ normal Tyrode solution which was aerated with $3%\;CO_2-97%\;O_2$ mixed gas and kept at $35^{\circ}C$. Resting Passive tension at $l_{max}$ was approximately 30% of the total tension and appeared from the muscle length of 0.90 $l_{max}$. The effect of stimulus frequency on the steady state level of developed tension was: As the stimulus frequency was increased from 0.1 to 0.5 Hz, there was little change in developed tension. As the frequency was increased further, to a value of about 3 Hz, tension increased steeply. Further increase of the frequency to 5 Hz had little additional effect on the developed tension. The length-tension curves for isometric peak tension became more steeper with the degree of potentiation by inotropic interventions. The relative steepness of the normalized length-tension curves where tension production was expressed as a percentage of maximal tension developed at $l_{max}$, varied inversely with the level of inotropic state and these curves were not superimposable one another. Thus at the stimulus frequency of 2 Hz or at the external Ca concentration of 8 mM, the relative decline in the developed tension for a given change in muscle length was considerably less than the decline observed at the frequency of 0.5 Hz or at the concentration of 2 mM Ca. Action potential duration was prolonged significantly as the frequency increased from 0.2 to 2 Hz, and this change in action potential duration was not observable on the changes in muscle length. There was a tendency of the hyperpolarization of membrane potential when the muscle length was shortened from $l_{max}$ to 0.95 $l_{max}$. These results support the hypothesis that there is a length-dependence of the activation process.

  • PDF

An Analysis of the Correlation between High Heels and Pain in the Low Back, Knee, Ankle and Toe, Length of Legs, and Plantar Pressure among Women in Their Twenties. (하이힐을 자주 착용하는 20대 여성의 허리, 무릎, 발목 및 발가락 통증, 다리 길이 그리고 족저압과의 상관분석)

  • Lee, Min-woo;Jeong, Yeon-woo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.26 no.2
    • /
    • pp.11-18
    • /
    • 2020
  • Background: The purpose of this study is to examine the correlation between high heels and body imbalance among female college students in their twenties who mainly wear high heels and prevent associated problems. Methods: The subjects included 89 female college students in their twenties. They were measured in plantar pressure with a gait analyzer. Their legs were measured in length with a tape measure. Their pain intensity and pain frequency were measured in visual analog scale and in pain rating score. Results: There were statistically positive correlations between right leg length and low back pain frequency (p<.05) and negative correlations between the left hindfoot and low back pain frequency (p<.05). There were statistically positive correlations between right leg length and knee pain frequency (p<.05) and positive correlations between the ankle pain intensity and right leg length (p<.05). Conclusion: The stronger the pain was in the ankle, the stronger and more frequent their lumber pain was. When the pressure of the left heel was lower, the frequency of lumbar pain increased.

Determination of the Length of Coaxial Type Carbon Grounding Electrode to Minimize the Fluctuation of Grounding Impedance (접지임피던스의 변동이 최소가 되는 동축형 탄소접지전극의 길이의 산정)

  • Lee, Kang-Soo;Kim, Jong-Ho;Lee, Bock-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.164-170
    • /
    • 2010
  • For the surge currents like lightning or ground fault currents containing high frequency components which cause the electromagnetic interferences for the electronic devices and communication equipment, the grounding impedances give the significantly composite characteristics which are dependent on the frequency of surge currents. In this paper, the analytical model and method for determining the optimal length of the newly developed coaxial type carbon ground electrode which has a little fluctuation in grounding impedance with frequency. The length of minimizing the fluctuation of grounding impedance by changing frequency from 100[Hz] to 1[MHz] was determined, and the validity of this proposed method was confirmed by comparing with the simulated and measured data.

Vocal Tract Length Normalization for Speech Recognition (음성인식을 위한 성도 길이 정규화)

  • 지상문
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.7
    • /
    • pp.1380-1386
    • /
    • 2003
  • Speech recognition performance is degraded by the variation in vocal tract length among speakers. In this paper, we have used a vocal tract length normalization method wherein the frequency axis of the short-time spectrum associated with a speaker's speech is scaled to minimize the effects of speaker's vocal tract length on the speech recognition performance In order to normalize vocal tract length, we tried several frequency warping functions such as linear and piece-wise linear function. Variable interval piece-wise linear warping function is proposed to effectively model the variation of frequency axis scale due to the large variation of vocal tract length. Experimental results on TIDIGITS connected digits showed the dramatic reduction of word error rates from 2.15% to 0.53% by the proposed vocal tract normalization.