• 제목/요약/키워드: LENGTH FREQUENCY

검색결과 3,069건 처리시간 0.026초

사각 기판의 길이진동을 이용하는 초소형 공진자에 있어서 사각 기판의 세변의 길이비가 공진특성에 미치는 영향 (Effects of Three Side Ratios of the Rectangular Substrate on the Resonant Characteristics of the Ultra-small Size Resonator Using Its Length Extensional Vibration)

  • 이개명;한성훈;김병효
    • 한국전기전자재료학회논문지
    • /
    • 제13권11호
    • /
    • pp.932-937
    • /
    • 2000
  • The length extensional vibration mode of a piezoelectric ceramic substrate is used in fabricating the ultra-small size resonators and filters. In general, the three side ratios of the rectangular substrate affect the resonant characteristics of the resonator using its length extensional vibration. In this paper, their relationships are studied. We know that changing the ratio of its length to its width makes possible to change the resonant frequency of the width vibration without degrading the length extensional vibration. And frequency constant for length extensional vibration becomes slightly small as the substrate thickness becomes thin, but it does not change as its length changes. Electro-mechanical coupling factor for length extensional vibration, k$\_$31/ does not change as its length changes within length/width$\geq$4, but it becomes small as its width increases.

  • PDF

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

인버터 열펌프의 주파수 및 모세관 길이 변화에 따른 시스템 성능특성의 실험적 연구 (An experimental study on the performance of inverter heat pump with a variation of frequency and capillary size)

  • 최종민;김용찬;김종엽;배영돈
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.64-72
    • /
    • 1997
  • An experiment study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4141W(3550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of 1000mm which was optimum size for the frequency of 60Hz and ARHRAE Test condition A was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycle was invesigated by varying the length of capillary tube at each frequency levels of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency levels. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher EER, while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

Double Gate MOSFET의 RF특성분석 (Analysis of Radio Frequency characteristics for Double Gate MOSFET)

  • 김근호;고석웅;정학기
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.690-692
    • /
    • 2003
  • 본 논문에서는 main gate 50nm를 갖는 double gate MOSFET에서 side gate의 길이변화에 따른 주파수 특성을 조사하였다. side gate길이가 감소할수록 컷오프 주파수는 증가하는 것을 볼 수 있었다. 결과적으로 side gate 길이가 70nm일 때 최적의 동작 특성을 보였으며, 이때 컷오프 주파수는 41.4GHz로 매우 높은 컷오프 주파수를 갖음을 알았다.

  • PDF

이중주파수 가진이 후향계단 유동에 미치는 영향 (Effect of Two-Frequency Forcing on Flow Behind a Backward-Facing Step)

  • 유정열;진송완;김성욱;최해천;김사량
    • 대한기계학회논문집B
    • /
    • 제26권3호
    • /
    • pp.423-431
    • /
    • 2002
  • An experimental study is conducted to investigate the effect of two-frequency forcing on turbulent flow behind a backward-facing step at the Reynolds number of 27000 based on the step height. The forcing is provided from a thin slit located at the edge of the backward-facing step to increase mixing behind the backward-facing step and consequently to reduce the reattachment length. With single frequency forcing, the minimum reattachment length is obtained at the non-dimensional forcing frequency (F) of St$\_$h/ = 0.29. With two-frequency forcing, a subharmonic frequency (F/2) or biharmonic frequency (2F) is combined with the fundamental frequency (F), i.e. (F, F/2) or (F, 2F) forcing is applied. In the case of (F, F/2) forcing, the reattachment length is not much sensitive to the phase difference between F and F/2. However, the reattachment length significantly depends on the phase difference between F and 2F in the case of (F, 2F) forcing. At a certain range of the phase difference, the reattachment length becomes smaller than that of the single frequency forcing.

화염거동을 통한 이중선회 가스터빈 모델 연소기에서 연소실 길이에 따른 연소 불안정성 이해 (Combustion Instability Comprehension with Combustion Chamber Length in Dual Swirl Gas Turbine Model Combustor from Flame Behaviors)

  • 장문석;이기만
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.233-235
    • /
    • 2015
  • This study is to investigate the combustion instability of the variation of combustion chamber length in dual swirl gas turbine model combustor. When equivalence ratio was fixed at 1.1, as the length of the combustion chamber increases the value of the frequency decreased in 7kW while the value of the frequency was constant in 4kW. The analysis of flame behaviors by high speed camera was conducted to identify such trend.

  • PDF

적출 유두근에서 근육길이에 따른 계단현상 및 칼슘 수축력의 변화 (Length-dependent Staircase Phenomenon and Calcium Inotropisn in Isolated Rabbit Papillary Muscle)

  • 김기환;엄융의;남기용
    • The Korean Journal of Physiology
    • /
    • 제14권2호
    • /
    • pp.7-16
    • /
    • 1980
  • The effects of various inotropic interventions on the shape of the steady state length tension relation and the length-dependent activation process in cardiac muscle were studied. The influence of inotropic interventions upon the action potential was also observed. The range of varying muscle length was from the optimal length$(l_{max})$, where the active tension production is maximal, to 0.85 $l_{max}$. Changes in stimulus frequency or in external bathing Ca concentration constituted the inotropic interventions in this experiment. The papillary muscles were isolated from the rabbit right ventricles and perfused with $HCO-_3\;-buffered$ normal Tyrode solution which was aerated with $3%\;CO_2-97%\;O_2$ mixed gas and kept at $35^{\circ}C$. Resting Passive tension at $l_{max}$ was approximately 30% of the total tension and appeared from the muscle length of 0.90 $l_{max}$. The effect of stimulus frequency on the steady state level of developed tension was: As the stimulus frequency was increased from 0.1 to 0.5 Hz, there was little change in developed tension. As the frequency was increased further, to a value of about 3 Hz, tension increased steeply. Further increase of the frequency to 5 Hz had little additional effect on the developed tension. The length-tension curves for isometric peak tension became more steeper with the degree of potentiation by inotropic interventions. The relative steepness of the normalized length-tension curves where tension production was expressed as a percentage of maximal tension developed at $l_{max}$, varied inversely with the level of inotropic state and these curves were not superimposable one another. Thus at the stimulus frequency of 2 Hz or at the external Ca concentration of 8 mM, the relative decline in the developed tension for a given change in muscle length was considerably less than the decline observed at the frequency of 0.5 Hz or at the concentration of 2 mM Ca. Action potential duration was prolonged significantly as the frequency increased from 0.2 to 2 Hz, and this change in action potential duration was not observable on the changes in muscle length. There was a tendency of the hyperpolarization of membrane potential when the muscle length was shortened from $l_{max}$ to 0.95 $l_{max}$. These results support the hypothesis that there is a length-dependence of the activation process.

  • PDF

하이힐을 자주 착용하는 20대 여성의 허리, 무릎, 발목 및 발가락 통증, 다리 길이 그리고 족저압과의 상관분석 (An Analysis of the Correlation between High Heels and Pain in the Low Back, Knee, Ankle and Toe, Length of Legs, and Plantar Pressure among Women in Their Twenties.)

  • 이민우;정연우
    • 대한정형도수물리치료학회지
    • /
    • 제26권2호
    • /
    • pp.11-18
    • /
    • 2020
  • Background: The purpose of this study is to examine the correlation between high heels and body imbalance among female college students in their twenties who mainly wear high heels and prevent associated problems. Methods: The subjects included 89 female college students in their twenties. They were measured in plantar pressure with a gait analyzer. Their legs were measured in length with a tape measure. Their pain intensity and pain frequency were measured in visual analog scale and in pain rating score. Results: There were statistically positive correlations between right leg length and low back pain frequency (p<.05) and negative correlations between the left hindfoot and low back pain frequency (p<.05). There were statistically positive correlations between right leg length and knee pain frequency (p<.05) and positive correlations between the ankle pain intensity and right leg length (p<.05). Conclusion: The stronger the pain was in the ankle, the stronger and more frequent their lumber pain was. When the pressure of the left heel was lower, the frequency of lumbar pain increased.

접지임피던스의 변동이 최소가 되는 동축형 탄소접지전극의 길이의 산정 (Determination of the Length of Coaxial Type Carbon Grounding Electrode to Minimize the Fluctuation of Grounding Impedance)

  • 이강수;김종호;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.164-170
    • /
    • 2010
  • For the surge currents like lightning or ground fault currents containing high frequency components which cause the electromagnetic interferences for the electronic devices and communication equipment, the grounding impedances give the significantly composite characteristics which are dependent on the frequency of surge currents. In this paper, the analytical model and method for determining the optimal length of the newly developed coaxial type carbon ground electrode which has a little fluctuation in grounding impedance with frequency. The length of minimizing the fluctuation of grounding impedance by changing frequency from 100[Hz] to 1[MHz] was determined, and the validity of this proposed method was confirmed by comparing with the simulated and measured data.

음성인식을 위한 성도 길이 정규화 (Vocal Tract Length Normalization for Speech Recognition)

  • 지상문
    • 한국정보통신학회논문지
    • /
    • 제7권7호
    • /
    • pp.1380-1386
    • /
    • 2003
  • 화자들 사이의 성도의 길이의 변이에 의하여 음성 인식기의 성능이 저하된다. 본 연구에서는 입력 음성에서 추출한 단구간 스펙트럼의 주파수축을 확대하거나 축소하여 음성인식기에 미치는 화자사이의 성도 길이의 영향을 최소화하는 방법을 사용한다 성도의 길이를 정규화하기 위한 주파수 변환 함수로서, 선형의 주파수 변환 함수와 조각적 선형적인 변환 함수를 고려하였다. 또한, 커다란 성도길이의 변이에 따른 주파수축의 척도변화를 보다 효과적으로 모의할 수 있는 가변구간 조각적 선형함수를 제안한다. TIDIGITS 연결 숫자음 음성자료에 대하여 제안한 방법을 적용한 결과, 단어의 오인식률을 2.15%에서 0.53%로 크게 감소시킴으로서, 성도 길이 정규화가 화자 독립 음성인식기의 성능 향상에 필수적임을 알 수 있었다.