• Title/Summary/Keyword: LED lights

Search Result 295, Processing Time 0.028 seconds

Hydroponic Nutrient Solution and Light Quality Influence on Lettuce (Lactuca sativa L.) Growth from the Artificial Light Type of Plant Factory System (인공광 식물공장에서 수경배양액 및 광질 조절이 상추 실생묘 생장에 미치는 영향)

  • Heo, Jeong-Wook;Park, Kyeong-Hun;Hong, Seung-Gil;Lee, Jae-Su;Baek, Jeong-Hyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.38 no.4
    • /
    • pp.225-236
    • /
    • 2019
  • BACKGROUND: Hydroponics is one of the methods for evaluating plant production using the inorganic nutrient solutions, which is applied under the artificial light conditions of plant factory system. However, the application of the conventional inorganic nutrients for hydroponics caused several environmental problems: waste from culture mediums and high nitrate concentration in plants. Organic nutrients are generally irrigated as a supplementary fertilizer for plant growth promotion under field or greenhouse conditions. Hydroponic culture using organic nutrients derived from the agricultural by-products such as dumped stems, leaves or immature fruits is rarely considered in plant factory system. Effect of organic or conventional inorganic nutrient solutions on the growth and nutrient absorption pattern of green and red leaf lettuces was investigated in this experiment under fluorescent lamps (FL) and mixture Light-Emitting Diodes (LEDs). METHODS AND RESULTS: Single solution of tomatoes (TJ) and kales (K) deriving from agricultural by-products including leaves or stems and its mixed solution (mixture ration 1:1) with conventional inorganic Yamazaki (Y) were supplied for hydroponics under the plant factory system. The Yamazaki solution was considered as a control. 'Jeockchima' and 'Cheongchima' lettuce seedlings (Lactuca sativa L.) were used as plant materials. The seedlings which developed 2~3 true leaves were grown under the light qualities of FL and mixed LED lights of blue plus red plus white of 1:2:1 mixture in energy ratio for 35 days. Light intensity of the light sources was controlled at 180 μmol/㎡/s on the culture bed. The single and mixture nutrient solutions of organic and/or inorganic components which controlled at 1.5 dS/m EC and 5.8 pH were regularly irrigated by the deep flow technique (DFT) system on the culture gutters. Number of unfolded leaves of the seedlings grown under the single or mixed nutrient solutions were significantly increased compared to the conventional Y treatment. Leaf extension of 'Jeockchima' under the mixture LED radiation condition was not affected by Y and YK or YTJ mixture treatments. SPAD value in 'Jeockchima' leaves exposed by FL under the YK mixture medium was approximately 45 % higher than under conventional Y treatment. Otherwise, the maximum SPAD value in the leaves of 'Cheongchima' seedlings was shown in YK treatment under the mixture LED lights. NO3-N contents in Y treatment treated with inorganic nutrient at the end of the experiment were up to 75% declined rather than increased over 60 % in the K and TJ organic treatment. CONCLUSION: Growth of the seedlings was affected by the mixture treatments of the organic and inorganic solutions, although similar or lower dry weight was recorded than in the inorganic treatment Y under the plant factory system. Treatment Y containing the highest NO3-N content among the considered nutrients influenced growth increment of the seedlings comparing to the other nutrients. However effect of the higher NO3-N content in the seedling growth was different according to the light qualities considered in the experiment as shown in leaf expansion, pigmentation or dry weight promotion under the single or mixed nutrients.

Evaluation of New LED Curing Light on Resin Composite Polymerization (발광 다이오드 광중합기의 복합레진 중합 평가)

  • Kang, Jieun;Jun, Saeromi;Kim, Jongbin;Kim, Jongsoo;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.2
    • /
    • pp.152-156
    • /
    • 2014
  • The purpose of this study is to compare efficiency of broad spectrum LEDs ($VALO^{(R)}$, Ultradent, USA) with conventional LED curing lights ($Elipar^{TM}$ Freelight 2, 3M ESPE, USA) using a microhardness test. The light curing units used were $VALO^{(R)}$ in three different modes and $Elipar^{TM}$ Freelight 2. The exposure time was used according to the manufacturer's instructions. After cured resin specimens were stored in physiological saline at $37^{\circ}C$ for 24 hours, microhardness was measured using Vickers microhardness tester. The microhardness of upper and lower sides of the specimens were analyzed separately by the ANOVA method (Analysis of Variance) with a significance level set at 5%. At upper side of resin specimens, an increased microhardness was observed in the broad spectrum LED curing light unit with a high power mode for 4 seconds and plasma emulation mode for 20 seconds (p < 0.05). However, at the lower side of resin specimens, there were no significant differences in microhardness between broad spectrum LED curing light unit and conventional LED curing light unit.

Improvement of Seed Germination in Rosa rugosa (해당화의 종자 발아 연구)

  • Lee, Ji-Yeon;Lee, Ja-Hyun;Ki, Gwang-Yeon;Kim, Seung-Tae;Han, Tae-Ho
    • Horticultural Science & Technology
    • /
    • v.29 no.4
    • /
    • pp.352-357
    • /
    • 2011
  • Rose seed shows low germination percentages (about 20%) because it has a high amount of substances that inhibit germination in the pericarp. We investigated the effect of orientation of achene, the day after pollination (DAP), and cold storage with or without half-cut in achene for the germination percentage in R. rugosa. Germination percentages of intact or half-cut achenes were investigated in a 16-hour photoperiod at $25^{\circ}C$ room on basal MS medium for two weeks. In germination percentage, maximum 100% was measured within one week when half-cut achenes were cultured on an orientation that the embryos facing to the light. Half-cut achenes at 90 DAP were germinated 100% regardless of cold storage. Various LED lights (red, blue, yellow, green, and white) were illuminated over the half-cut achenes to gain the effect of light color. Germination percentage of R. rugosa seeds under blue LED reached the greatest with 90% within one week of culture and these seedlings were the best with a steady growth rate. It is concluded that half-cut achenes would be an effective method to improve seed germination in R. rugosa without stratification or scarification. This system could be applied to breeding studies in rose cultivars.

Comparison of the Characteristics of Seed Germination and the First Stage of Growth in Cynanchum wilfordii (Maxim.) by Different Light Conditions (광조건별 백수오의 종자 발아 특성 및 초기생육 비교)

  • Yoo, Ji Hye;Seong, Eun Soo;Lee, Jae Geun;Kim, Chul Joong;Choi, Jae Hoo;Lee, Gi Hye;Hwang, In Seong;Hwang, Eun Bee;Lim, Jung Dae;Ahn, Young Sup;Park, Chung Berm;Yu, Chang Yeon
    • Korean Journal of Medicinal Crop Science
    • /
    • v.21 no.5
    • /
    • pp.329-333
    • /
    • 2013
  • This study was carried out to compare the characteristics of seed germination and the first stage of growth in Cynanchum wilfordii (Maxim.) by different light conditions such ass fluorescent light, dark and light emitting diode (LED). There was not much difference from the germination rate of C. wilfordii (Maxim.) in different light conditions for 10 days. The highest of germination rate occurred over 91.11 percentage by LED red condition at $26^{\circ}C$. Also mean germination velocity and promptness index were represented the highest results of 2.3 ea/day and 52.67 under red light, respectively. But mean germination time under both LED red and blue light was represented low data that it takes over three days for germinating of seed. Even though handling both LED red and blue lights, the germination uniformity was not constant. These results may help our understanding of variations in germination characteristics for C. wilfordii (Maxim.) seeds treated under different light conditions.

A Study of Different Sources and Wavelengths of Light on Laying Egg Characteristics in Laying Hens (산란계에 대한 점등 광원 및 파장 차이에 따른 산란 특성에 관한 연구)

  • Kim, Min-Ji;Choi, Hee-Chul;Suh, Ok-Suk;Chae, Hyun-Suk;Na, Jae-Cheon;Bang, Han-Tae;Kim, Dong-Wook;Kang, Hwan-Ku;Park, Sung-Bok
    • Korean Journal of Poultry Science
    • /
    • v.37 no.4
    • /
    • pp.383-388
    • /
    • 2010
  • The chicken eye can discriminate light color, and different light wavelengths may affect reproduction ability. This study was carried out to identify effect of monochromatic light using light emitting diode (LED) in laying hens. Chickens were exposed to white light (WL), blue light (BL), yellow light (YL), green light (GL) and red light (RL) made by using LED as well as incandescent light (IL) (control). All light sources were equalized to a light intensity of 20 lux. The results indicated that the age of first egg laying and 50 % egg laying in laying hens treated under RL is significantly younger than under other lights (P<0.05). And the ovary weight of laying hens reared under RL is significantly heavier than under other at from 16 to 20 wks (P<0.05). The largest number of eggs production was produced in a group with treated with RL by 59 wks of age compared with any other group. The egg weight of YL was greater than other treatment groups from 26 to 45 wks (P<0.05). The egg shell from hens treated with RL was the strongest and thickest at 20 wk (P<0.05). These results suggest that the egg quality of laying hens reared in different spectrum of LED can be different and RL may enhance the laying performance.

In Vitro Quantum Dot LED to Inhibit the Growth of Major Pathogenic Fungi and Bacteria in Lettuce (Quantum Dot LED를 이용한 상추 주요 병원성 곰팡이 및 세균의 생장억제효과 기내실험)

  • Lee, Hyun-Goo;Kim, Sang-Woo;Adhikari, Mahesh;Gurung, Sun Kumar;Bazie, Setu;Kosol, San;Gwon, Byeong-Heon;Ju, Han-Jun;Ko, Young-Wook;Kim, Yong-Duk;Yoo, Yong-Whan;Park, Tae-Hee;Shin, Jung-Chul;Kim, Min-Ha;Lee, Youn Su
    • Research in Plant Disease
    • /
    • v.25 no.3
    • /
    • pp.114-123
    • /
    • 2019
  • QD LED has an ideal light source for growing crops and can also be used to control plant pathogenic microorganisms. The mycelial growth inhibition effect of QD LED light on Rhizoctonia solani, Phytophthora drechsleri, Sclerotinia sclerotiorum, Sclerotinia minor, Botrytis cinerea, Fusarium oxysporum, Pectobacterium carotovorum, and Xanthomonas campestris were investigated. According to the results, BLUE (450 nm) light, suppressed S. sclerotiorum by 16.7% at 50 cm height from the light source, and 94.1% mycelial growth at 30 cm height. Mycelial growth of Sclerotinia minor was inhibited by 80.4% at 50 cm height and 36.3% at 50 cm height in B. cinerea. S. minor, and B. cinerea was inhibited by 100% mycelial growth at a height of 30 cm from the light source. At 15 cm height, all three pathogens (B. cinerea, S. minor, and S. sclerotiorum) was inhibited by 100%. QD RED (M1) and QD RED (M2) light suppressed mycelial growth of S. minor and B. cinerea by 100% at 30 cm and 15 cm height from the light source. For S. sclerotiorum, QD RED (M1) and QD RED (M2) showed 75.2% and 100% inhibition, respectively. Further experiment was conducted to know the suppression effect of lights after inoculating the fungal pathogens on lettuce crop. According to the results, QD RED (M2) suppressed the S. sclerotiorum by 59.9%. In addition, Blue (450 nm), QD RED (M1), and QD RED (M2) light reduce the infestation by 59.9%. In case of B. cinerea, disease reduction was found 84% by BLUE (450 nm) light. Results suggest that the growth inhibition of mycelium increases by Quantum dot LED light.

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.

Design and Implementation of Context Awareness Smart Jewelry Device (상황인식 스마트 주얼리 디바이스 설계 및 구현)

  • Kang, YunJeong;Choi, DongOun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.11
    • /
    • pp.2113-2118
    • /
    • 2016
  • Smart Jewelry is applied to the components of the Internet of Things. The process of obtaining the status information to the input of the sensor. And it controls the light color of the LED. Because to express the beauty of twinkling lights that can be felt in the jewelery and aesthetic functions were applied in order to feel the mystery. Smart Jewelry is capable of communication, interaction, wearable. Smart jewelery was equipped with a color, temperature, ambient light sensor. It was designed to allow interaction with a Bluetooth module. Applying an algorithm so that the light jewelry colors can vary depending on the circumstances of the smart jewelry wearer had been implemented by the mobile application. It can be realized in digital technology and the convergence of life. It presents the orientation development of the smart jewelery device on IoT environment.

Transition-based Data Decoding for Optical Camera Communications Using a Rolling Shutter Camera

  • Kim, Byung Wook;Lee, Ji-Hwan;Jung, Sung-Yoon
    • Current Optics and Photonics
    • /
    • v.2 no.5
    • /
    • pp.422-430
    • /
    • 2018
  • Rolling shutter operation of CMOS cameras can be utilized in optical camera communications in order to transmit data from an LED to mobile devices such as smart-phones. From temporally modulated light, a spatial flicker pattern is obtained in the captured image, and this is used for signal recovery. Due to the degradation of rolling shutter images caused by light smear, motion blur, and focus blur, the conventional decoding schemes for rolling shutter cameras based on the pattern width for 'OFF' and 'ON' cannot guarantee robust communications performance for practical uses. Aside from conventional techniques, such as polynomial fitting, histogram equalization can be used for blurry light mitigation, but it requires additional computation abilities resulting in burdens on mobile devices. This paper proposes a transition-based decoding scheme for rolling shutter cameras in order to offer simple and robust data decoding in the presence of image degradation. Based on the designed synchronization pulse and modulated data symbols according to the LED dimming level, the decoding process is conducted by observing the transition patterns of two sequential symbol pulses. For this, the extended symbol pulse caused by consecutive symbol pulses with the same level determines whether the second pulse should be included for the next bit decoding or not. The proposed method simply identifies the transition patterns of sequential symbol pulses other than the pattern width of 'OFF' and 'ON' for data decoding, and thus, it is simpler and more accurate. Experimental results ensured that the transition-based decoding scheme is robust even in the presence of blurry lights in the captured image at various dimming levels

Shear bond strength between gold alloy and orthodontic metal bracket using light emitting diode curing light (Light emitting diode를 이용한 광중합 시 금합금과 교정용 금속 브라켓의 전단접착강도)

  • Jung, Min-Ho;Chung, Shin-Hye;Shon, Won-Jun
    • The korean journal of orthodontics
    • /
    • v.40 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • Objective: The need to bond orthodontic brackets onto various alloys has increased because of the increasing demand for adult orthodontic treatment. This study tried to evaluate the shear bond strength between gold alloy and metal bracket using light emitting diode (LED) light curing after metal primer and silicoating surface conditioning. Methods: Half of the type III gold alloy plates were treated with sandblasting with aluminum oxide and metal primer containing 4-META. the other half were treated with silica and silane. Metal brackets were bonded with Transbond XT light curing adhesive on these plates and shear bond strength were evaluated 1 hour, 6 hours, and 24 hours later. The differences of shear bond strength between groups were evaluated with two-way ANOVA. Results: The results showed higher bond strength in the silicoating group and a tendency of bond strength increase over time. Conclusions: When using LED curing lights for metal bracket bonding to alloy surfaces, long curing time and silicoating can produce a reliable bonding strength.