• 제목/요약/키워드: LED (Light-Emitting Diode)

검색결과 851건 처리시간 0.026초

Nanopatterned Surface Effect on the Epitaxial growth of InGaN/GaN Multi-quantum Well Light Emitting Diode Structure

  • Kim, Keun-Joo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권2호
    • /
    • pp.40-43
    • /
    • 2009
  • The authors fabricated a nanopatterned surface on a GaN thin film deposited on a sapphire substrate and used that as an epitaxial wafer on which to grow an InGaN/GaN multi-quantum well structure with metal-organic chemical vapor deposition. The deposited GaN epitaxial surface has a two-dimensional photonic crystal structure with a hexagonal lattice of 230 nm. The grown structure on the nano-surface shows a Raman shift of the transverse optical phonon mode to $569.5\;cm^{-1}$, which implies a compressive stress of 0.5 GPa. However, the regrown thin film without the nano-surface shows a free standing mode of $567.6\;cm^{-1}$, implying no stress. The nanohole surface better preserves the strain energy for pseudo-morphic crystal growth than does a flat plane.

악관절잡음 환자의 하악운동양상 (Patterns of Mandibular Movement of Patients with TMJ Noise)

  • Sung Chang Chung;Young Ok Lee
    • Journal of Oral Medicine and Pain
    • /
    • 제11권1호
    • /
    • pp.19-27
    • /
    • 1986
  • Registration of the mandibular movement in patients with temporomandibular joint noise (clicking and/or crepitus) was performed using one of mandibular tracking devices(SAPHON VISI-TRAINER CII,Tokyo Shizai-sha Inc.,Japan). The obtained results were follows : 1. In many cases, the movement pattern of light emitting diode(LED) attached on the mandibular midline showed lateral deviation from a vertical reference line which was pronounced in association with TMJ noise during opening and closing. 2. In patients with unilateral TMJ noise the mandibular midline usually towards the side demonstrating TMJ noise during opening. 3. A distinct V-shaped discontinuity in the trace of velocity of mandibular movement was found at the point of the TMJ noise. 4. In patients with TMJ noise the velocity of mandibular movement at the point of the TMJ noise was decreased rapidly. 5. In several cases, TMJ noise could be eliminated by traning of Rocabado`s control of TMJ rotations.

  • PDF

Indian Railways: Recent Trends in Control Accidents and Safety Measures for Passengers

  • Kumar, Katta Ashok
    • 동아시아경상학회지
    • /
    • 제2권4호
    • /
    • pp.48-55
    • /
    • 2014
  • Indian railways has been regularly in the news albeit for the wrong reasons. The frequency with which train accidents have been taking place has led to serious doubts in the public mind about the safety of rail travel and also the health of the network. Against this background, an attempt is made in this paper to assess the trends in railway accidents for the period from 2000-01 to 2009-10. The paper also highlighted the various measures taken by IR to prevent accidents to ensure safety to the public.

발광다이오드를 이용한 초정밀 변위 측정용 마이크로 엔코더 칩 제작 (Fabrication of Optical Micro-Encoder Chips for Sub-Micron Displacement Measurements)

  • 김근주;김윤구
    • 한국정밀공학회지
    • /
    • 제16권2호통권95호
    • /
    • pp.74-81
    • /
    • 1999
  • The integrated chip of optical micro-encoder was fabricated and the feasibility as displacement measurement device was confirmed. The geometry of micro-encoder was designed to utilize the optical interference effect on the second order of diffracted beams. The hybrid-type micro-encoder consisted with light emitting diode, photodiode, polyimide wave-guide and micro-lens provides stable micro-encoding results for high speed displacements. The measurement shows the resolution of displacement of 1.00 +/- 0.02 ${\mu}m$ for the grating with scale pitch of 2.0${\mu}m$.

  • PDF

Photodynamic Therapy for Methicillin-resistant Staphylococcus aureus with High-level Mupirocin Resistance using 630 nm Light-emitting Diode

  • Kwon, Pil-Seung;Kim, Jin-Kyung
    • 대한의생명과학회지
    • /
    • 제16권4호
    • /
    • pp.331-339
    • /
    • 2010
  • This study aims to evaluate the effect of Photodynamic Therapy (PDT) against methicillin-resistant Staphylococcus aureus with high-level mupirocin resistance (Hi-Mup MRSA). To examine the antimicrobial effect of photogem-mediated PDT against Hi-Mup MRSA, CFU quantifications, bacteria cell viability tests, and disk diffusion antimicrobial susceptibility tests were evaluated. In addition, one of PDT mechanisms was investigated by accumulating photogem ($10\;{\mu}g/ml$) in Hi-Mup MRSA. Photogem-mediated PDT properly inhibited the colony formation of Hi-Mup MRSA. Viable bacteria decreased greatly after a PDT application with photogem $10\;{\mu}g/ml$ at energy density $15\;J/cm^2$. The diameter of the inhibition zone around susceptible disks increased after PDT. In addition, we confirmed the accumulation of photogem in bacteria through fluorescent images. These results demonstrated that excellent photosensitization of Hi-Mup MRSA can be achieved using photogem with 630 nm LED irradiation. Thus, PDT may make survival Hi-Mup MRSA inactive.

PCS 대역용 안테나 내장형 단말기의 성능 분석 (Performance Analysis of Mobile Station with Built-in Antenna for PCS Band)

  • 공성신;오종대;양운근
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.560-564
    • /
    • 2003
  • In this paper, we carried out performance analysis of mobile station with built-in antenna for PCS(Personal Communication System) band. The radiation patterns for antenna and mobile phone were simulated by using 3D simulation program, HFSS(High Frequency Structure Simulator) and SEMCAD(Simulation Platform for Electromagnetic Compatibility Antenna Design Dosimetry). We observed radiation pattern variation according to installation of LED(Light Emitting Diode) circuit and ground pattern. The radiation pattern of prototype mobile phone was measured, and the radio sensitivity was measured by using Agilent E5515C and chamber. The measured maximum antenna gain at 1.87GHz was 0.21dBi. The measured radio sensitivity of prototype mobile phone shows proper performances comparable to other models with external antennas.

  • PDF

The Implementation of The Multi-Subject, Multi-Channel Optical Telemetry System for Physiological Signals

  • 박차훈;박종대;서희돈
    • 센서학회지
    • /
    • 제9권6호
    • /
    • pp.448-454
    • /
    • 2000
  • This paper describes the implementation of a multi-subject, multi-channel optical telemetry system for the short range measurement of electrocardiograms (EKGs) a system which receives command signals and transmits physiological signals to the external system using LED (Light Emitting Diode) and PD (Photodiode). This system decreases the dependency of power supply voltage to the CMOS IC chips and a new enforced synchronization technique using infrared bi-directional communication has also been proposed. The telemetry IC with the size of $5.1{\times}5.1mm^2$ has the following functions: receiving of command signal, initialization of internal state of all functional blocks, decoding of subject selection signal, time division multiplexing of 4-channel modulated physiological signals, transmission of modulated signals to external system, and auto power down control.

  • PDF

ITO 박막의 연마특성과 마찰력 신호와의 상관관계 (Relationship between Frictional Signal and Polishing Characteristics of ITO Thin Film)

  • 장원문;박기현;박범영;서헌덕;김형재;정해도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.479-480
    • /
    • 2006
  • The purpose of this paper is to investigate the relationship between CMP(Chemical Mechanical Polishing) characteristics of ITO thin film and friction signal by using the CMP monitoring system. Suba 400 pad and MSW2000 slurry of the Rohm & Haas Co. was used in this experiment to investigate the charateristics of ITO CMP. From this experiment, it is proven that the coefficient of friction is related to uniformity of the removal rate of the ITO thin film. Therefore, the prediction of polishing result would be possible by measuring friction signal.

  • PDF

Determination of temperature and flux variations during ultra-thin InGaN quantum well growth on a 2" wafer for GaN Green LED

  • 김효정;김민호;정훈영;이현휘
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.149-149
    • /
    • 2010
  • The origin of the inhomogeneous distribution of photoluminescence (PL) peak wavelength on a commercial 2" GaN wafer for green light emitting diode has been investigated by wide momentum transfer (Q) range x-ray diffraction (XRD) profile of InGaN/GaN multiple quantum wells. Near the GaN (0004) Bragg peak, wide-Q range XRD (${\Delta}Q$ > $1.4{\AA}-1$) was measured along the growth direction. Wide-Q XRD gives precise and direct information of ultra-thin InGaN quantum well structure. Based on the QW structural information, the variation of PL spectra can be explained by the combined effect of temperature gradient and slightly uneven flow of atomic sources during the QW growth. In narrow variations of indium composition and thickness of QW, an effective indium composition can be a good character to match structural data to PL spectra.

  • PDF