• Title/Summary/Keyword: LED검사

Search Result 234, Processing Time 0.043 seconds

The Self-regulating Fire Prevention System in Korea: with the Focus on the Role of Insurance System (자율예방체계의 구축 -규제개혁의 차원에서 보험의 역할을 중심으로-)

  • 김태윤
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.55-65
    • /
    • 2001
  • This paper's purpose is three-folded: modeling the self-regulating fire prevention system, developing a packet of practical fire prevention measures and regulations, and reviewing the applicability of fire insurance system in Korea as a main components of the self-regulating fore prevention system. The so called self-regulating fire prevention system is defined as a grand national fire prevention framework based on and promoted by the vitality and creativeness of the market (or private sector). This drastically contrasts with the existing government-led fire prevention system in Korea. The self-regulating fire prevention system has three grounds: the principle of self-responsibility, the redefinition of the fire service as a public goods, and the principle of self-selection. It seems natural that the self-regulating fire prevention system requires the function of fire insurance institution as a pivoting mechanism providing individual decision makers with a system of incentives, resulting in rational behaviors in the part of each individuals and in the well-balanced fire prevention network in the part of the overall public. In this regard, this pilfer examines the institutions and performance of the fire insurance industry in Korea and reviews the limitation of the industry as an instant replacement mechanism of the current government-led fire prevention system in Korea.

  • PDF

A study on the Quality Characteristics of Rice Bread Containing Trehalose (트레할로스를 첨가한 쌀식빵의 품질특성)

  • Bae, Dae Seok;Lee, Jin Shik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.568-577
    • /
    • 2018
  • This study was conducted to evaluate the quality characteristics. Trehalose was used to manufacture rice bread in two ways: one was to substitute trehalose for sugar by (0, 25, 50, and 75%) trehalose in each sample and the other was to analyze the temporal changes in rice bread on Day 0, on Day 2, and on Day 4. The results concerning the characteristics of specific volumes, water content, water activity, variation in weight and height, physical property test, and sensory test and measurements of the temporal changes are as follows: First, as for variation in specific volumes, rice bread containing trehalose had the content and temporal changes decrease significantly (p<0.001). Second, as for texture, a higher trehalose content led to a slightly lower level of hardness. As for the temporal changes, addition of trehalose is generally effective in decreasing hardness of rice bread. the sample containing trehalose showed an almost similar value. The control group not containing trehalose showed the significantly lowest level of cohesiveness, springiness, Chewiness. Finally, the sensory evaluations revealed that the taste, Flavor, and Sweetness was at a significantly higher level in the group with trehalose substituted for sugar than in the control group. An increase in the trehalose content led to an increase in overall eating quality.

Development of the Internet-Based Educational Software Package for the Design and Virtual Experiment of the Digital Logic Circuits (디지탈 논리회로 설계 및 모의 실험 실습을 위한 인터넷 기반 교육용 소프트웨어 패키지 개발)

  • Ki Jang-Geun;Ho Won
    • Journal of Engineering Education Research
    • /
    • v.2 no.1
    • /
    • pp.10-16
    • /
    • 1999
  • In this paper, we developed the internet-based educational software package (DVLab) for design and virtual experiment of the digital logic circuits. The DVLab consists of the LogicSim module for design and simulation of digital combinational/sequantial logic circuits, micro-controller application circuits and the BreadBoard module for virtual experiment and the Theory module for lecture and the Report/ReportChecker module and some other utility modules. All developed modules can be run as application programs as well as applets in the Internet. The LogicSim and the BreadBoard support real time clock function, output verification function on the designed circuits, trace function of logic values, copy-protection function of designed circuits and provide various devices including logic gates, TTLs, LED, buzzer, and micro-controller. The educational model of digital logic circuit design and experiment using the DVLab is also presented in this paper.

  • PDF

Development of a Smartphone-based Total Bilirubin Measuring System for Screening of Jaundice (황달 선별검사를 위한 스마트폰 기반의 총빌리루빈 측정시스템의 개발)

  • Kim, Won-Jung;Song, Eunji;Rhee, Joowon
    • Journal of Appropriate Technology
    • /
    • v.7 no.2
    • /
    • pp.206-210
    • /
    • 2021
  • Hyperbilirubinemia is the most common neonatal disease and is observed in about 80% of newborns worldwide in neonatal period within a week after birth. Untreated infant hyperbilirubinemia may lead to brain damage and even death, so it is very important to diagnose it quickly and accurately. In this study, a total bilirubin measurement system was developed that is portable and easy to use without pre-processing using a commercial smartphone. This system measures using the LED and camera of the smartphone without the need for additional devices, and because a small amount of blood is injected without pre-treatment, anyone can easily measure it in the field. In a comparative study with Cobas c111 results, accuracy meets CLIA guidelines with 94% (17/18) within ±0.4 mg/dL below 3 mg/dL and 98% within ±20% above 3 mg/dL (276/282). This system offers a simple, fast and accurate diagnosis for jaundice in infants and young children in low-resource settings.

Evaluation of Reliability about Short TAT (Turn-Around Time) of Domestic Automation Equipment (Gamma Pro) (국산 자동화 장비(Gamma Pro)의 결과보고시간 단축에 대한 유용성 평가)

  • Oh, Yun-Jeong;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.197-202
    • /
    • 2010
  • Purpose: Recently, many hospitals have been tried to increase the satisfaction of the outpatients through blood-gathering, exam, result notice and process in a day. Each laboratory has been used the automatic equipment for the rapid requests of the result notice and the increase of the reliability and efficiency. Current automatic equipments that have been limited short TAT(Turn-Around Time)because of the restricted batch lists and 1 tip-5 detectors. The Gamma Pro which is made in Korea to improve the shortcomings of existing automation equipment, complemented with capacity to perform a wide range of domestic automation equipment. In this study, we evaluated the usefulness and reliability of short TAT by comparing Gamma Pro with current automatic equipment. Materials and Methods: We studied the correlation between Gamma Pro and RIA-mat 280 using the respective 100 specimens of low or high density to the patients who were requested the thyroid hormone test (Total T3, TSH and Free T4) in Samsung Medical Center Sep. 2009. To evaluate the split-level Gamma Pro, First, we measured accuracy and carry over on the tips. Second, the condition of optimal incubation was measured by the RPM (Revolution Per Minute) and revolution axis diameter on the incubator. For the analysis for the speed of the specimen-processing, TAT was investigated with the results in a certain time. Result: The correlation coefficients (R2) between the Gamma Pro and RIA-mat 280 showed a good correlation as T3 (0.98), TSH (0.99), FT4 (0.92). The coefficient of variation (C.V) and accuracy was 0.38 % and 98.3 % at tip 1 and 0.39 % and 98.6 % at tip 2. Carry over showed 0.80 % and 1.04% at tip 1 and tip 2, respectively. These results indicate that tips had no effect on carry over contamination. At the incubator condition, we found that the optimal condition was 1.0mm of diameter at 600RPM in 1.0mm and 1.5mm of at 500RPM or 1.0mm and 1.5 mm of diameter at 600 RPM. the Gamma Pro showed that the number of exam times were increased as maximum 20 times/day comparing to 6 times/day by current automatic equipment. These results also led to the short TAT from 4.20 hour to 2.19 hours in whole processing. Conclusion: The correlation of between the Gamma Pro and RIA-mat 280 was good and has not carry over contamination in tips. The domestic automation equipment (Gamma Pro) decreases the TAT in whole test comparing to RIA-280. These results demonstrate that Gamma Pro has a good efficiency, reliability and practical usefulness, which may contribute to the excellent skill to process the large scale specimens.

  • PDF

Consolidative Bronchioloalveolar Carcinoma Presenting as Pneumonia, and This Led to a Late Diagnosis due to the Improvement after Antibiotic Therapy (항생제 치료 후 호전을 보여 진단이 늦어진 폐선암/세기관지폐포암 1예)

  • Jeong, Ina;Heo, Eun Young;Lee, Jae Seok;Yoon, Ho Il;Lee, Jae Ho;Lee, Choon-Taek;Kang, Young Ae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.2
    • /
    • pp.147-151
    • /
    • 2008
  • Non-resolving or slowly resolving pulmonary infiltrates in spite of administering adequate antimicrobial therapy are a clinical diagnostic challenge for physicians. The rate of radiographic resolution varies with the patients' age, the underlying comorbidities, the extent of radiographic involvement, the functional status and the causal pathogens. It is important to differentiate non-resolving or slowly resolving bacterial pneumonia from other uncommon infectious pneumonias or malignancies that require invasive diagnostic techniques to confirm the diagnosis. Bronchioloalveolar carcinoma can present with various clinical and radiographic features. Unfortunately, the radiographic similarity of consolidative BAC to pneumonia often leads to an incorrect diagnosis of pneumonia and possibly significant delays in obtaining appropriate diagnostic studies. We describe here a case of a mixed adenocarcinoma and bronchioloalveolar carcinoma that was initially diagnosed as pneumonia due to the consolidation pattern on the radiography and the patient's initial improvement with antibiotic treatment.

CTX-M-14 Producing Enterobacteriaceae Isolated from Chickens at Gyeongsang Provinces (경북지역의 닭으로부터 CTX-M-14 생성 장내세균 분리동정)

  • Sung, Ji Youn;Kwon, Taek Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.118-123
    • /
    • 2016
  • Antimicrobial agents have been used in poultry for treatment of bacterial infections or additives over the past half century. However, increasing antimicrobial resistance has led to selective pressure for therapeutic use in humans and made treatment of bacterial infection more difficult. In this study, we examined the prevalence of plasmid mediated antimicrobial resistant determinants for resistance to ${\beta}-lactam$, quinolone, and aminoglycoside in Enterobacteriaceae isolates obtained from chickens in Gyeongsang provinces, and correlation between the resistant genes and antimicrobial resistance rate was also assessed. A total of 43 Enterobacteriaceae isolates were recovered from 40 chickens at Gyeongsang provinces in Korea. Antimicrobial susceptibility was determined by disk diffusion method. PCR and DNA sequencing were performed to characterize the antimicrobial resistant genes. Of the 43 Enterobacteriaceae isolates tested, 2 isolates harbored $bla_{CTX-M-14}$ gene, and 2 and 5 strains contained qnrS and aac(6')-Ib-cr genes, respectively. A total of 43 isolates displayed a relatively lower susceptible rate ranging between 0.0 and 23.3% to most of the antimicrobial agents, except cefepime, ceftazidime, and cefaclor. We confirmed that plasmid mediated antimicrobial resistant determinants were distributed in Enterobacteriaceae isolates from chickens. Investigation of the genes and monitoring of antimicrobial resistance rate is required to prevent further spreading of antimicrobial resistant genes among Enterobacteriaceae isolates.

Labeling Efficiency of $^{99m}Tc$-Labeled RBC Due to Labeling Time Change (표지시간 변화에 의한 $^{99m}Tc$과 적혈구 표지효율)

  • Dong, Kyeong-Rae;Kim, Ho-Seong;Choi, Seong-Kwan
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.259-263
    • /
    • 2007
  • For the preparation of $^{99m}Tc$-labeled RBC, $10{\sim}20\;{\mu}g/kg$ of Stannous(II) chloride and $10{\sim}40\;min$ of preparation was used. For finding out the effect of contrast agent, the blood samples were collected in three days, seven days, and 1 months after the diagnostic procedure. In the normal volunteer, the concentration of reducing agent and preparation time did not effect on the radiochemical yield. But in the patients, 10 mg of Stannous(II) chloride and 60 min incubation times was shown high radiochemical yield. Contrast agent has a significant effect on the radiochemical yield. Although the blood samples which were collected after seven days of diagnostic procedure did not effect on the radiochemical yield of $^{99m}Tc$-labeled RBC, but the radiochemical yield of $^{99m}Tc$-labeled RBC which was prepared with a sample of high concentration of contrast agent in blood led to low radiochemical yield. For these samples, the modified method showed high radiochemical yield than previous in vivo preparation method. The recommended method is followed. Blood collecting was performed at 30 minutes after injection of reducing agent, and it is centrifuged for removal of plasma. After addition of $^{99m}TcO^-_4$, sample reservoir was rotated. After addition of normal saline, and it is centrifuged for separation of saline. Then $^{99m}Tc$-labeled RBC was obtained after removal of saline.

  • PDF

Evaluation of the Method for Total Homocysteine in Plasma Using LC-MS/MS (LC-MS/MS를 이용한 Homocysteine 측정과 그 유용성 평가)

  • Jun, Sun-Hee;Lim, Mi-Suk;Jung, Yong-Sun;Song, Jung-Han
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.22-26
    • /
    • 2005
  • Total homocysteine is now considered a risk factor for cardiovascular diseases. I increased interest has led to a multitude of studies requiring the determination of total homocysteine in conjunction with other factor. There are various methods for measuring total homocysteine, including HPLC, FPIA, GC-MS and LC-MS/MS. The most recent method for measuring total homocysteine uses a deuterium-labelled internal standard and tandem mass spectrometry. This development requires no derivatization and therefore leads to an increase in sample throughput compared to other techniques. We have evaluated the method for homocysteine by the LC-MS/MS method, and the correlation between the FPIA method and the LC-MS/MS method. The standard curve (0, 5, 10, 20, 50, 100 uM) was linear over the range examined (up to 100 uM). The lower limit of quantification (CV < 10 %) was 0.5 uM/L and the lower limit of detection (S/N >3) was 0.1 uM/L. Intra-assay variation and inter-assay variation were both <6 %. The comparision study for homocysteine concentration showed good correlation (r=0.9684) between the FPIA method and LC-MS/MS methods. Our conclusion is that the method showed relatively good precision, and was rapid and accurate.

  • PDF

Imaging of the Brachial Plexus (상완신경총의 영상)

  • Suh, Kyung-Jin;Lee, Jeong-Hyun;Lee, Gyung Kyu
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.119-126
    • /
    • 2007
  • MR (magnetic resonance) imaging of the brachial plexus is challenging because of the complex and tangled anatomy of the brachial plexus and the multifariouness of pathologies that can put on it. Improvements in imaging techniques, including the availability of high resolution MR image systems and high channels multidetector computed tomography (CT), have led to more accurate diagnoses and improved serve for treatment planning. For the purpose of imaging and treatment of the brachioplexopathy, it is considerate to divide traumatic and nontraumatic diseases affecting the brachial plexus. MRI is the current gold standard imaging modality for nontraumatic brachial plexopathy. CT myelography is the preferred for the diagnosis of nerve root avulsions affecting the brachial plexus. Other modalities, such as CT, ultrasonography and positron emission tomography, have a limited role in the evaluation of brachial plexus pathology. High-quality, high-resolution MRI remains the main tool for imaging the brachial plexopathy.

  • PDF