• Title/Summary/Keyword: LED검사

Search Result 234, Processing Time 0.04 seconds

Diffuse Large B-Cell Lymphoma Manifesting as Miliary Nodules in the Lung: A Case Report (폐의 좁쌀 결절로 발현된 림프종 사례: 증례 보고)

  • Hyo Ju Na;Hyeyoung Kwon;Song Soo Kim;Hyung Kyu Park
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1391-1396
    • /
    • 2023
  • Malignant lymphoma has various pulmonary manifestations on chest CT, including nodules, masses, areas of consolidation, and ground-glass opacity. These presentations can pose a diagnostic challenge, as they mimic other disease patterns. Herein, we report a case of diffuse large B-cell lymphoma (DLBCL) manifesting as miliary nodules in a 67-year-old male initially presenting with dyspnea and fever. Radiologic findings included diffuse, bilateral, multiple tiny nodules consistent with metastasis, miliary tuberculosis, and fungal infection. However, further investigations, including laboratory tests, imaging, and biopsies, led to the diagnosis of DLBCL involving the lungs. Herein we reported a rare case of lymphoma involvement of the lung presenting as miliary nodules. Accurate diagnosis relies on a comprehensive evaluation of the clinical history, physical features, laboratory test results, and imaging findings.

An automated visual inspection of solder joints using 2D and 3D features (2차원 및 3차원 특징값을 이용한 납땜 시각 검사)

  • 김태현;문영식;박성한
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.11
    • /
    • pp.53-61
    • /
    • 1996
  • In this paper, efficient techniques for solder joint inspection have been described. Using three layers of ring shaped LED's with different illumination angles, three frames of images are sequentially obtained. From these images the regions of interest (soldered regions) are segmented, and their characteristic features including the average gray level and the percentage of highlights - refereed to as 2D features - are extracted. Based on the backpropagation algorithm of neural networks, each solder joint is classified intor one of the pre-defined types. If the output value is not in the confidence interval, the distribution of tilt angles-referred to as 3D features - is claculated, and the solder joint is classified based on the bayes classfier. The second classifier requires more computation while providing more information and better performance. The proposed inspection system has been implemented and tested with various types of solder joints in SMDs. The experimental results have verified the validity of this scheme in terms of speed and recognition rate.

  • PDF

Development of Real-Time Inspection System for Foods Packaging Film using MMX Technology (MMX기술을 이용한 식품 포장용 투명필름의 실시간 검사시스템 개발)

  • Yoo, Joo-Hyun;Lee, Jae-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.156-158
    • /
    • 2004
  • Film printing companies have many problems during a printing process. Most of all, even an insect or dirt stick to the transparent film may cause severe errors until the end of printing job, which means big economic damage to the company. To prevent some insect-dots or dirt-dots, we have to Inspect the total area of film. However, it is very difficult to inspect the film in real-time due to the high-speed of printing that usually more than 150 m/min. A hardware based approach, for example DSP-based approach can be the one of solution candidates, but the total cost and the complexity increases the very high-level. In this paper, we suggest a software based approach, using MMX technology, to inspect the film in real-time. By Many real-plant experiments, we can see the suggest approach is applicable for the inspection of food packaging film in real-time.

  • PDF

Asian Quality Assurance Survey Program for Clinical Laboratory (아시아 임상검사실 정도관리 프로그램)

  • Lee, Gap-No
    • Journal of Korea Association of Health Promotion
    • /
    • v.4 no.1
    • /
    • pp.60-67
    • /
    • 2006
  • Purpose : Asian Quality Assurance Survey program(AQuAS) is and activity of Asian Network for Clinical Laboratory Standardization and Harmonization(ANCLS) which had begun her first colloquium in 1999 in Jakarta, Indonesia by laboratory physicians led by Professors Noriyuki Tatsumi and Yoshinori Funahara with themes of standardization and harmonization of clinical laboratories in Asia. Methods : AQuAS had begun its first survey in July. 2001 and done November and March, three times per year in the fields of Chemistry, Hematology. Coagulation and Urinalysis. As of June 2006 the 15th survey have been completed. Korean Association of Health Promotion(KAHP) had participated in it since July, 2004 in the fields of chemistry, hematology and urinalysis.ゝ⨀

  • PDF

Placement inspection of the SMT components using 3-D vision (시각센서를 이용한 SMT 부품장착상태 검사)

  • 손영탁;오형렬;윤한종
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.605-608
    • /
    • 1996
  • The aim of this thesis is to develop a SMT-components placement inspection system equipped with a visual sensor. The visual sensor, which consists of a camera and 2-layer LED illuminator, developed to inspect the component placement state such as missing, shift, flipping, polarity and tomb-stone. on PCB in the reflow-process. In practical applications, however, it is too hard to classify component from images mixed pad on PCB, cream solder paste and component. To overcome the problem, this thesis proposes the 2-layer illumination method and the heuristic image processing algorithms according to inspection type. To show the effectiveness of the proposed approach, a series of experiments on the inspection were conducted. The results show that the proposed method is robust to visual noise and variations in component conditions.

  • PDF

Development of Inspection System of Welded Nuts on Support Hinge using Machine Vision (비전을 이용한 자동차 Support Hinge의 너트용접 검사 시스템 개발)

  • Kim Seong-Min;Lee Young-Choon;Lee Seong-Cheol
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.307-308
    • /
    • 2006
  • This paper is about the development of automatic inspection system of welded nuts on Support hinge using machine vision for the improvement of working condition. Until now, projection welding process was performed by operator. Also, inspection of welded nuts is performed manually and recorded by the operator's naked eye. So these processes caused the produce of poorly-made articles. To improve this manual operation, inspection system using machine vision is introduced. Test algorithm, lighting system and program showed good results to the designed inspection system and led to the increment of productivity.

  • PDF

Current Trends and Future Development in Pharmacologic Stress Testing (약물부하 검사법의 현재와 미래)

  • Bae, Jin-Ho;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.107-113
    • /
    • 2005
  • Pharmacologic stress testing for myocardial perfusion imaging is a widely used noninvasive method for the evaluation of known or suspected coronary artery disease. The use of exercise for cardiac stress has been practiced for over 60 years and clinicians are familial with its using. However, there are inevitabe situations in which exorcise stress is inappropriate. A large number of patients with cardiac problems are unable to exercise to their full potential due to comorbidity such as osteoarthritis, vascular disease and pulmonary disease and a standard exercise stress test for myocardial perfusion imaging is suboptimal means for assessment of coronary artery disease. This problem has led to the development of the pharmacologic stress test and to a great increase in its popularity. All of the currently used pharmacologic agents have well-documented diagnostic value. This review deals the physiological actions, clinical protocols, safety, nuclear imaging applications of currently available stress agents and future development of new vasodilating agents.

A Study on Utilization of Nondestructive Inspection Method for Defects Evaluation in Electric Multiple Units (도시철도차량 결함평가를 위한 비파괴검사 기법의 적용방안)

  • Pyun, Jang-Sik;Chung, Jong-Duk
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.673-679
    • /
    • 2009
  • Nondestructive inspection(NDI) is a testing procedure used to easily inspect an object for internal defects, abnormalities, shape, and structure, etc. without destroying it. Typical candidates for NDI include buildings, railways, aircraft, bridges, underground pipelines and various types of factory equipment. Recent advances in nondestructive evaluation(NDE) technologies have led to improved methods for quality control and in-service inspection, and the development of new options for material diagnostics. This paper introduces the methods of a survey and assessment on NDI applications in Electric Multiple Units(EMU). The main objective of this paper was to obtain information on various applications of NDI technology in EMU.

  • PDF

Usefulness of Image Registration in Brain Perfusion SPECT (Brain Perfusion SPECT에서 Image Registration의 유용성)

  • Song, Ho-June;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.60-64
    • /
    • 2011
  • Purpose: The brain perfusion SPECT is the examination which is able to know adversity information related brain disorder. But brain perfusion SPECT has also high failure rates by patient's motions. In this case, we have to use two days method and patients put up with many disadvantages. We think that we don't use two days method in brain perfusion SPECT, if we can use registration method. So this study has led to look over registration method applications in brain perfusion SPECT. Materials and Methods: Jaszczak, Hoffman and cylindrical phantoms were used for acquiring SPECT image data on varying degree in x, y, z axes. The phantoms were filled with $^{99m}Tc$ solution that consisted of a radioactive concentration of 111 MBq/mL. Phantom images were acquired through scanning for 5 sec long per frame by using Triad XLT9 triple head gamma camera (TRIONIX, USA). We painted the ROI of registration image in brain data. So we calculated the ROIratio which was different original image counts and registration image counts. Results: When carring out the experiments under the same condition, total counts differential was from 3.5% to 5.7% (mean counts was from 3.4% to 6.8%) in phantom and patients data. In addition, we also run the experiments in the double activity condition. Total counts differential was from 2.6% to 4.9% (mean counts was from 4.1% to 4.9%) in phantom and patients data. Conclusion: We can know that original and registration data are little different in image analysis. If we use the image registration method, we can improve disadvantage of two days method in brain perfusion SPECT. But we must consider image registration about the distance differences in x, y, z axes.

  • PDF

Ductal carcinoma in situ arising within a fibroadenoma of breast (유방의 섬유선종에서 발생한 관상피내암)

  • Won, Tae Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.454-458
    • /
    • 2017
  • Fibroadenoma are one of the most common benign tumors of the breast in young women. Fibroadenoma may be associated with fibrocystic change, proliferative epithelial changes, and extremely rarely with carcinoma. We report here two cases of malignancy arising from a breast fibroadenoma. The patients were 19 and 51 years old and presented with a lump of recent onset. A 19-year-old female patient was diagnosed with mass excision at another hospital, and re-excision was performed at the hospital. Ultrasonography and cytologic examination revealed fibroadenoma and malignancy in a 51-year-old female patient, who was treated with wide excision. The pathological report of the two cases was revealed as DCIS in a fibroadenoma. Because carcinoma arising within a fibroadenoma is so rare, there are few reports of its characteristics or guidelines for treatment. Careful analysis of the unusual carcinoma arising within a fibroadenoma of the breast led to appropriate diagnosis and treatment of various types of lesions. Herein, we report two cases of DCIS arising within a fibroadenoma of the breast and provide a review of the literature.