• Title/Summary/Keyword: LEAD TIME

Search Result 3,628, Processing Time 0.027 seconds

Accuracy and Precision according to Optimal Preparation by Analysis of Urine Lead (뇨중 연 분석의 정확성 및 정밀성에 미치는 최적 전처리법)

  • 장봉기;정은희;박종안;손부순;이종화
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.91-101
    • /
    • 2001
  • In order to propose a optimum method increasing accuracy and reproducibility in analysis of urine lead levels, we compared matrix modifier addition method and microwave digestion method. The results were as follows ; 1. Where the concentration of $Pd(NO_3)_2$(matrix modifier) was $50mg/{\ell}$, and ashing temperature was $900^{\circ}C$, the results were optimum. In case of matrix modifier addition method, the average coefficient of variation (CV) of normal man was 24.1%, and lead worker was 7.9%. The average urine lead levels of standard were $10.42\mu{g}/{\ell}$ and $19.89\mu{g}/{\ell}$ , the accuracies compared to reference values were 97.0% and 92.6%, respectively. 2. Microwave digestion temperature($160~180^{\circ}C$), time(15~25min) and the ratio of urine/ashing acid(1:1~4:1) did not significantly affect lead absorbance and background absorbance. Therefore we set up a optimum analytical conditions as follows: temperature, $160^{\circ}C$; time, 15min; the ratio of urine/ashing acid, 4:1. after samples were digested by the above analytical conditions, lead absorbance and background absorbance was measured at $450^{\circ}C$ as ashing temperature. The average coefficient of variation (CV) of normal man was 12.4%, and lead worker was 6.2%. The average urine lead levels of standard urine were $10.66\mu{g}/{\ell}$ and $23.31\mu{g}/{\ell}$, the accuracies compared to reference values were 99.3% and 103.9%, respectively. From the results, we suggest that microwave digestion method is a more favorable method than matrix modifier addition method because of easiness to reduce organic matter, possibility to analysis at low temperature and accuracy.

  • PDF

Identification of Pb-Zn ore under the condition of low count rate detection of slim hole based on PGNAA technology

  • Haolong Huang;Pingkun Cai;Wenbao Jia;Yan Zhang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1708-1717
    • /
    • 2023
  • The grade analysis of lead-zinc ore is the basis for the optimal development and utilization of deposits. In this study, a method combining Prompt Gamma Neutron Activation Analysis (PGNAA) technology and machine learning is proposed for lead-zinc mine borehole logging, which can identify lead-zinc ores of different grades and gangue in the formation, providing real-time grade information qualitatively and semi-quantitatively. Firstly, Monte Carlo simulation is used to obtain a gamma-ray spectrum data set for training and testing machine learning classification algorithms. These spectra are broadened, normalized and separated into inelastic scattering and capture spectra, and then used to fit different classifier models. When the comprehensive grade boundary of high- and low-grade ores is set to 5%, the evaluation metrics calculated by the 5-fold cross-validation show that the SVM (Support Vector Machine), KNN (K-Nearest Neighbor), GNB (Gaussian Naive Bayes) and RF (Random Forest) models can effectively distinguish lead-zinc ore from gangue. At the same time, the GNB model has achieved the optimal accuracy of 91.45% when identifying high- and low-grade ores, and the F1 score for both types of ores is greater than 0.9.

Analysis of R&D Time Lag in impacting Firm Value: GMM- PVAR Study (GMM Panel VAR를 이용하여 R&D가 기업 가치에 영향을 미치기까지의 시간 측정 연구)

  • Yang, Insun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.63-76
    • /
    • 2016
  • Most previous studies found a positive relationship between the value of a firm and its R&D investments. This research measures the impact of the timescale of the R&D investment of a firm on its value using panel vector autoregression. By measuring the time required for R&D to impact the value of a firm, this study demonstrates that the lead time is an essential factor in the analysis of the effect of R&D investment on a firm's value. Our study finds that the length of the lead time varies according to the firm's size, industry concentration, and book to market ratio. Firms with a higher industry concentration show a shorter lead time. Also, firms with a larger size and higher book to market ratio generally show a shorter lead time.

International Multimodal Transport Route Development from Korea to Mongolia

  • Nyamjav, Tsenskhuu;Ha, Min-Ho
    • Journal of Navigation and Port Research
    • /
    • v.46 no.5
    • /
    • pp.419-426
    • /
    • 2022
  • This study aimed to identify new routes for transporting automobiles from Korea to Mongolia by comparing them with the existing route. At present, a route from the Incheon Port through the Tianjin Port to Zamiin-Uud is commonly used to transport containerized cargo from Korea to Mongolia. This study examined five possible logistics routes from Korea to Mongolia using a time/cost-distance methodology based on real data. Through consecutive discussions with importers and freight forwarders in Mongolia, the potential routes were selected and costs, distance, and lead time were evaluated to provide additional route options for automobile logistics from Korea to Mongolia. The results indicated that each route could be ranked in terms of the total cost while the lead time for all options in the present COVID-19 period is 2 - 4 months, with no difference among the routes. In addition, although the confidence index of all routes was not impressive, route 3 was the most preferred option, followed by route 1. However, the study results cannot provide the answer to the question of "which route is more attractive for transporting automobiles from Korea to Mongolia." This limitation notwithstanding, this study provides real information on the critical factors of distance, cost, and lead time in terms of the selected transportation routes so that importers and exporters can compare the routes in terms of the priority of each factor in uncertain logistics environment.

The Effects of Multi-minerals on Susceptibility to Lead Toxicity in Rats

  • Lu, Jing;Zhang, Jun;Zhang, Lili;Cui, Tao;Xie, Guangyun;He, Xiwen
    • Toxicological Research
    • /
    • v.17
    • /
    • pp.135-138
    • /
    • 2001
  • Female Wistar rats were randomly divided into 5 groups: Control, received distilled water; Low lead, received 0.5 g/ιlead (as acetate) in drinking water; High lead, received 2.0 g/ιlead; Low lead + Minerals, received 0.5 g/ιlead in drinking water and received minerals (Ca$^{2+}$, 25 mg/kg/day; Fe$^{3+}$, 0.47 mg/ kg/day; Zn$^{2+}$, 0.33 mg/kg/day; Se, 0.83 $\mu\textrm{g}$/kg/day) by gavage; High lead + Minerals, received 2.0 g/ιlead and received the same minerals. Animals exposure to lead was from 10 days before mating till postnatal day 21; and the minerals was administered from the first day of pregnancy and during lactation. No statistical difference was found either in body weights or in blood lead levels between the pups received minerals and those only exposed to lead at the same dose. The developmental and behavioral teratological effects of lead on pups, such as time-lag of eye opening, pinna detachment, fur developing, incisor eruption, ear unfolding, and surface righting were observed in this study; and the minerals decreased the toxicity of lead either in low or in high lead exposure pups. The numbers of step-down were significantly increased in lead exposed animals, and the effect of intervention by the minerals was appeared only in the pups exposed to low lead. The ChAT activity and levels of glutamate and aspartate in hippocampus decreased in treated animals compared to control animals, no effect of intervention by the minerals was found. The results of this study indicate that the applied multi-minerals can alter the outcome of develop-mental lead poisoning in rats.s.s.s.

  • PDF

Effects of Various Anions on Absorption and Toxicity of Lead in Plants (식물체의 연(Pb) 흡수 및 유해성에 미치는 음이온의 영향)

  • 성민웅
    • Journal of Plant Biology
    • /
    • v.20 no.1
    • /
    • pp.7-14
    • /
    • 1977
  • The seeds of bean(Glycine max M.) and corn(Zea mays L.) soaked in 5000ppm lead solution for 24 hours were sowed in the flowerpots being placed sandy-clay soil under the field condition. The fixed concentrations of various anions and 2000 ppm lead were supplied alternately in the sandy-clay soi of the flowerpots at two days interval from May to July in 1976. After the plants were harvested prior to the flowering stage, the lead contents of plnat and soil were analyzed by atomic absorption spectrophotometer. The lead contents absorbed by the plant roots showed the highest in an weak acid soil of the best suitable condition of plant growth. The absorption of lead by the plant roots was inhibited by the various anions, especially divalent anions of the soil. Some phosphate anions inhibited lead absorption more than otehr various anions in the soil. The more various anions were in the soil, the more plants could be protected from the lead toxicity. In the case of lead supply in the soil, 99.5% of lead was accumulated in the upper layer of the soil(0-10cm), and 0.5% of lead accumulated in the lower layer (10-20cm). Therefore, the yellow-brown and white symptoms on the leaves and the inhibition of root growth by lead toxicity was increased in the early stage of the germination, however decreased in accordance with the progress of the growing stage becuase of the root growth toward beneath the lower layer of the soil. In spite of the contents of 3773ppm lead in the soil, the symptoms of lead toxicity was not found in the grown plants. At that time the lead contents of the plants absorbed from the soil were minimum 0.78ppm and maximum 3.64ppm through the growing stage.

  • PDF

A Repair-Time Limit Replacement Model with Imperfect Repair (불완전 수리에서의 수리시간한계를 가진 교체모형)

  • Chung, Il Han;Yun, Won Young
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.39 no.4
    • /
    • pp.233-238
    • /
    • 2013
  • This article concerns a profit model in a repair limit replacement problem with imperfect repair. If a system fails, we should decide whether we repair the failed system (repair option) or replace it by new one (replacement option with a lead time). We assume that repair times are random variables and can be estimated before repair with estimation error. If the estimated repair time is less than the specified limit (repair time limit), the failed unit is repaired but the unit after repair is different from the new one (imperfect repair). Otherwise, we order a new unit to replace the failed unit. The long run average profit (expected profit rate) is used as an optimization criterion and the optimal repair time limit maximizes the expected profit rate. Some special cases are derived.

Lead Ion Selective Solid Contact Electrode based on Tetramethylthiuram monosulfide ionophore (Tetramethylthiuram monosulfide를 ionophore로 이용한 납 이온 선택성 poly(aniline) 고체 접촉 전극)

  • Han, Won-Sik;Park, Woon-Suk;Kwon, Hye-Yeong;Lee, Young-Hoon;Hong, Tae-Kee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.356-361
    • /
    • 2013
  • Lead (II) ion selective poly(aniline) solid contact electrode based on Tetramethylthiuram monosulfide ionophore as a sulfur containing sensing material is successfully developed. The electrode exhibits good linear response of 25.6 mV / decade (at $20{\pm}0.2^{\circ}C$, r2=0.995) within the concentration range of $1.0{\times}10^{-1}{\sim}4.0{\times}10^{-7}$ M Pb (II). The composition of this electrode was Ionophore : PVC : dioctylphthalate : potassiumtetrakis(4-chlorophenyl)borate : Oleic acid = 5.0 : 20.0 : 25.0 : 4.0 : 5.0. When we consider the results of using different composition electrodes based on only one potassiumtetrakis(4-chlorophenyl)borate or Oleic acid liphophlic additive, poly(aniline) solid contact electrode based on Tetramethylthiuram monosulfide ionophore with potassiumtetrakis(4-chlorophenyl)borate and Oleic acid liphophlic additive had the best result in response characteristics. The electrode shows good selectivity for lead (II) ion in comparison with alkali, alkaline earth, transition and heavy metal ions. This electrode is suitable for use with aqueous solutions of pH 3.0 ~ 7.0 and their standard deviation in the measured emf differences was ${\pm}2.94$ mV at Tris buffered lead sample solution of $1.0{\times}10^{-2}$ M and ${\pm}2.82$ mV at Tris buffered lead sample solution of $1.0{\times}10^{-3}$ M. Their stabilization time was less than 710 s. and response time was less than 16 s.

Implementation of Smart Companion Dog Lead Line Integration Module using Heterogeneous Sensor Signal Monitoring (이기종 센서 신호 모니터링을 적용한 스마트 반려견 리드줄 통합 모듈 구현)

  • Cho, Joon-Ho;Kim, Bong-Hyun
    • Journal of Digital Convergence
    • /
    • v.17 no.11
    • /
    • pp.183-188
    • /
    • 2019
  • As social perceptions of pets change, cultural attitudes toward pets are becoming more friendly. In particular, dogs have been living familiarly and closely with humans for a long time. In the changing times, various services are being used to improve the understanding of dogs and to prevent companion dogs and increase awareness of respect for life. Therefore, in this paper, we implemented a smart lead line in which IoT service and application technology are linked to the walking dog's automatic lead line. To do this, we developed a smart dog lead line by designing and implementing an integrated module in connection with heterogeneous sensors and linking it with a dog lead line. Finally, a smart dog lead line was used to collect the dog's biological signals in real time, identify the location of the dog, and provide a notification system. Through this, we believe that the culture of dog culture can be further grown.

Practical Application of Lead-free Solder in Electronic Products

  • Cho Il-Je;Chae Kyu-Sang;Min Jae-Sang;Kim Ik-Joo
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2004.09a
    • /
    • pp.93-99
    • /
    • 2004
  • At present, LG Electronics pushes ahead to eliminate the Pb(Lead) -a hazardous material- from all products. Especially, we have performed to select the optimum standard composition of lead free alloy for the application to products for about 3 years from 2000. These days, we have the chance for applying to the mass-production. This project constructed the system for applying the lead free solders on consumer electronic products, which is one of the major products of the LG Electronics. To select the lead free solders with corresponding to the product features, we have passed through the test and applied with Sn-3.0Ag-0.5Cu alloy system to our products, and for the application to the high melting temperature composition, we secured the thermal resistance of the many parts and substrate and optimized the processing conditions. We have operated the temperature cycling test and the high temperature storage test under the standards to confirm the reliability of the products. On these samples, we considered the consequence of our decision by the operating test. For the long life time of the product, we have operated the temperature cycling test at $-45^{\circ}C-+125^{\circ}C$, 1 cycle/hour, 1000 cycles. Also we have tested the tin whisker growth about lead free plating on lead finish. We have analyzed with the SEM, EDS and any other equipment for confirming the failure mode at the joint and the tin whisker growth on lead free finish.

  • PDF