• 제목/요약/키워드: LC material

검색결과 544건 처리시간 0.026초

Liquid Crystal Alignment Effects on Nitrogen-doped Diamond like Carbon Layer by Ion Beam Alignment Method

  • Han, Jeong-Min;Choi, Sung-Ho;Kim, Byoung-Yong;Han, Jin-Woo;Kim, Jong-Hwan;Kim, Young-Hwan;Hwang, Jeoung-Yeon;Lee, Sang-Keuk;Ok, Chul-Ho;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권1호
    • /
    • pp.46-50
    • /
    • 2007
  • We have studied the nematic liquid crystal (NLC) alignment effects on a nitrogen-doped diamond-like carbon (NDLC) thin film layer with ion beam irradiation. The pretilt angle for NLC on the NDLC surface with ion beam exposure was observed below 1 degree. Also, we had the good LC alignment characteristics on the NDLC thin films with ion beam exposure of 1800 eV. In thermal stability experiments, the alignment defect of the NLC on the NDLC surface with ion beam irradiation above annealing temperature of $250^{\circ}C$ can be observed. Therefore, the good thermal stability and LC alignment for NLC by ion beam aligned NDLC thin films can be achieved.

돼지의 장에서 불리한 유산균의 항시균 활성물질에 관한 연구 (Study on the Antimicrobial Substances of Lactic Acid Bacteria Isolated from Pig's intestine)

  • 서정용;정명희;김영준
    • 유기물자원화
    • /
    • 제17권4호
    • /
    • pp.59-65
    • /
    • 2009
  • 돼지의 장 및 분변에서 분리한 14종의 유산균으로부터 항세균 활성물질을 분석하였다. 각 균주의 세포배양액을 대상으로 여러 종류의 단백질 분해효소와 열, 알칼리 처리 등을 수행한 후 활성도를 조사한 결과, 효소 및 열처리 시료에서는 활성도가 유지되었으나, 1M의 NaOH로 중화 처리한 시료에서는 활성도가 사라짐에 따라, 항세균 활성물질이 단백질성이라기보다 유기산일 가능성이 큰 것으로 나타났다. Sep-pak $C_{18}$ Cartridges을 이용한 음이온 추출실험과 Bio-LC system을 이용한 high performance anion exchange chromatography를 실시하여 물질을 정제한 결과, 주요 활성물질로 옥살산, 구연산, 젖산 및 초산 등, 4종류의 유기산이 검출되었다. 이중 젖산은 각 균주에 따라 전체 유기산의 54~77%를 차지하는 것으로 나타나 유기산 중에서도 일차적인 항세균 활성물질일 것으로 추정된다.

  • PDF

환경 및 생체시료 중 과불화 화합물의 분석 동향 (Analytical trend of perfluorinated compounds in environmental and biota samples)

  • 이원웅;장원희;표희수;강태석;홍종기
    • 분석과학
    • /
    • 제23권4호
    • /
    • pp.331-346
    • /
    • 2010
  • 과불화 화합물(perfluorinated compounds, PFCs)은 열과 산성, 염기 등과 같은 화학적 조건에 높은 안정성을 갖고 있을 뿐만 아니라 발수성, 발유성, 방오성과 제품 친화적인 특징 때문에 다양한 산업소재로 활용되고 있으며, 근래에 이르러서는 대규모로 생산되고 있는 산업제품이다. 그러나 난분해성으로 인하여 환경 내에 잔류하여 전세계적으로 널리 분포하고 있을 뿐만 아니라 인체나 동식물에 이르는 생물체에 이르기까지 오염되어 분포하고 있다. 또한 인체를 비롯한 생물체에 장기적으로 축적될 시 암등을 유발할 가능성이 있다고 보고됨에 따라 이에 대한 관심이 증가하고 있다. 최근 스톡홀름 협약에서 과불화 화합물을 새로운 환경지속성오염물질(persistent organic pollutants, POPs)로 규정함에 따라 이에 대한 분석법의 중요성이 대두되고 있다. 본 연구에서는 다양한 환경 및 생체 시료 내에서 과불화 화합물의 분석법에 대한 연구의 중요성 및 문제점과 더불어 최근 연구 동향을 소개하였다.

Evaluation of ginsenoside bioconversion of lactic acid bacteria isolated from kimchi

  • Park, Boyeon;Hwang, Hyelyeon;Lee, Jina;Sohn, Sung-Oh;Lee, Se Hee;Jung, Min Young;Lim, Hyeong In;Park, Hae Woong;Lee, Jong-Hee
    • Journal of Ginseng Research
    • /
    • 제41권4호
    • /
    • pp.524-530
    • /
    • 2017
  • Background: Panax ginseng is a physiologically active plant widely used in traditional medicine that is characterized by the presence of ginsenosides. Rb1, a major ginsenoside, is used as the starting material for producing ginsenoside derivatives with enhanced pharmaceutical potentials through chemical, enzymatic, or microbial transformation. Methods: To investigate the bioconversion of ginsenoside Rb1, we prepared kimchi originated bacterial strains Leuconostoc mensenteroides WiKim19, Pediococcus pentosaceus WiKim20, Lactobacillus brevis WiKim47, Leuconostoc lactis WiKim48, and Lactobacillus sakei WiKim49 and analyzed bioconversion products using LC-MS/MS mass spectrometer. Results: L. mesenteroides WiKim19 and Pediococcus pentosaceus WiKim20 converted ginsenoside Rb1 into the ginsenoside Rg3 approximately five times more than Lactobacillus brevis WiKim47, Leuconostoc lactis WiKim48, and Lactobacillus sakei WiKim49. L mesenteroides WIKim19 showed positive correlation with b-glucosidase activity and higher transformation ability of ginsenoside Rb1 into Rg3 than the other strains whereas, P. pentosaceus WiKim20 showed an elevated production of Rb3 even with lack of b-glucosidase activity but have the highest acidity among the five lactic acid bacteria (LAB). Conclusion: Ginsenoside Rg5 concentration of five LABs have ranged from ${\sim}2.6{\mu}g/mL$ to $6.5{\mu}g/mL$ and increased in accordance with the incubation periods. Our results indicate that the enzymatic activity along with acidic condition contribute to the production of minor ginsenoside from lactic acid bacteria.

광중합형 이장재와 금속의치상 간의 결합력에 관한 연구 (A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base)

  • 박인채;이준규;정재헌
    • 구강회복응용과학지
    • /
    • 제16권3호
    • /
    • pp.211-220
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recommendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univesal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strength than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strength of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

광중합형 이장재와 금속의치상 간의 결합력에 관한 연구 (A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base)

  • 박인채;이준규;정재헌
    • 구강회복응용과학지
    • /
    • 제16권2호
    • /
    • pp.161-170
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recomendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univasal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strengths than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strengths of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

Glass Ionomer Cement의 방사선 불투과성에 관한 연구 (A STUDY ON THE RADIOPACITY OF GLASS IONOMER CEMENTS)

  • 박수경;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.122-132
    • /
    • 1993
  • The aim of this study was to investigate the level of radiopacity of glass ionomer cements and to determine the optimum level of radiopacity that is the most compatible with the radiographic diagnosis of secondary caries. The experiments were performed in two parts. In the first part, the radiopacities of 9 glass ionomer cements (FI, FII, FI-LC, FII-LC, SI, SII, Vit, B-VLC, AC) and base materials(Ultra-Blend, Zinc phoaphate cements, Cavitec, Dycal) were measured by densitometer. Then all experimental materials were divided into 5 groups based on the level of radiopacity of enamel and dentin. In the second part, class III cavities with or without secondary caries were prepared in extracted anterior teeth. The representative materials of each group with different radiopacities were inserted into each cavity. The radiographs were interpreted by 15 dentists and seconsary caries were diagnosed according to a five-point confidence rating. Sensitivity and ROC analysis were used to compare observer performance. The following results were obtained : 1. The radipacity of glass ionomer cements varied between 1.111mm Al and 6.011mm Al equivalent. 2. Among experimental materials, three materials in group I had lower radiopacity than that of dentin. The radiopacity of two materials in group II slightly exeeded that of dentin. Three materials in group III had slightly lower radiopacity than that on enamel. The radiopacity of one material in group W was slightly higher than that of enamel. Four materals in group V had the radiopacity that exeeded over 2.0mm AI equivalent to that of enamel. 3. The group IV was the highest for sensitivity and the group V was the highest for ROC area. However, no significant differences were obtained among group II, III, IV and V (P<0.05) but only group I was significantly lower(P<0.01). 4. In comparison with the observer performance for the radiographic diagnosis of secondary caries, the group II, III, IV, and V were superior to the group I (P<0.01). And so the optimum level of radiopacity to detect the secondary caries was the radiopacity that is higher than that of dentin.

  • PDF

동위원소희석 액체크로마토그래피/질량분석법에 의한 혈청 내 콜레스테롤의 정량 (Quantification of cholesterol in human serum by isotope dilution liquid chromatography/mass spectrometry)

  • 신혜선;이화심;이계호
    • 분석과학
    • /
    • 제21권6호
    • /
    • pp.502-509
    • /
    • 2008
  • 혈청 내 콜레스테롤을 정량분석하기 위한 일차분석법으로 동위원소희석 액체크로마토그래피/질량분석법(isotope dilution liquid chromatography/mass spectrometry)을 사용하였다. 콜레스테롤은 Thermo ODS hypersil $C^{18}$ 칼럼을 사용하여 분리하였고, 이동상은 100% 메탄올, 유속은 0.3 mL/min으로 하였다. 콜레스테롤과 콜레스테롤-$3,4-13C_2$$[M-H_2O+H]^+$이온에 해당하는 m/z 369.4와 371.3에서 모니터링하여 정량에 합당한 크로마토그램을 얻을 수 있었다. 방법의 유효성을 증명하기 위해서 NIST SRM 909b를 분석한 결과 인증값과 불확도 범위 내에서 일치하는 것을 확인하였다. 이 방법을 바탕으로 혈청 인증표준 물질 4 종류를 제조하여 인증을 실시하였다. 인증 결과, 반복성의 상대표준오차는 0.1~0.8%, 재현성의 경우 0.24%이하, 확장 불확도는 95% 신뢰도구간에서 약 1.43%로 나타났다.

LC-MS Analysis According to the Combined Treatment of Paenibacillus yonginensis DCY84T and Silicon in Rice

  • Yo-Han Yoo;Mee Youn Lee;Yeon-Ju Kim;Eok-Keun Ahn;Ki-Hong Jung
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2022년도 추계학술대회
    • /
    • pp.232-232
    • /
    • 2022
  • We reported in our recent studies that the combined treatment of Paenibacillus yonginensis DCY84T (DCY84T) and Silicon (Si) promotes initial plant growth and increases resistance to biotic and abiotic stress. To understand the molecular background of these phenotypes, Liquid Chromatography Mass Spectrometry (LC-MS) analysis was performed, and it was confirmed that unsaturated fatty acid metabolites such as oleic acid and linoleic acid decreased in response to the combined treatment of DCY84T and Si. The stearoyl-acyl carrier protein desaturase (SACPD) introduces the cis double bond into the acyl-ACPs at C9, resulting in the production of unsaturated fatty acid. We identified OsSSI2 encoding SACPD in rice and found that the expression of OsSSI2 was reduced under DCY84T and Si treatment. Furthermore, qRT-PCR analysis revealed that the expression of OsWRKY45, which is downstream of OsSSI2, was upregulated in response to DCY84T and Si treatment. These results enable the speculation that activation of the salicylic acid (SA)-responsive gene, OsWRKY45, may contribute to enhancing biological stress resistance. Based on this, we propose a probable model for the rice defense pathway following DCY84T and Si treatment. This model retains a WRKY45-dependent but NH1(NPR1)-independent SA signaling pathway.

  • PDF

Noninvasive measuring;Detections of materials and quantities on eddy current testing

  • Obayashi, Koji;Tamura, Muneyoshi;Zhang, X.;Aoyama, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1555-1560
    • /
    • 2004
  • We made a simplified eddy-current-tester, and observed some materials for the ingredients and mass and locations. The tester detects the current as frequency shifts of a LC-resonance circuit, which are caused by the eddy currents. Using air-wick coil and a multi-piled ceramic capacitor, we made a resonance system whose frequency was 100KHz. The shift quantity is few; so, to detect it, we used a frequency counter, and counted the shift. We can detect 10Hz order's shift.

  • PDF