• Title/Summary/Keyword: LC material

Search Result 544, Processing Time 0.025 seconds

Liquid Crystal Alignment Effects on Nitrogen-doped Diamond like Carbon Layer by Ion Beam Alignment Method

  • Han, Jeong-Min;Choi, Sung-Ho;Kim, Byoung-Yong;Han, Jin-Woo;Kim, Jong-Hwan;Kim, Young-Hwan;Hwang, Jeoung-Yeon;Lee, Sang-Keuk;Ok, Chul-Ho;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.46-50
    • /
    • 2007
  • We have studied the nematic liquid crystal (NLC) alignment effects on a nitrogen-doped diamond-like carbon (NDLC) thin film layer with ion beam irradiation. The pretilt angle for NLC on the NDLC surface with ion beam exposure was observed below 1 degree. Also, we had the good LC alignment characteristics on the NDLC thin films with ion beam exposure of 1800 eV. In thermal stability experiments, the alignment defect of the NLC on the NDLC surface with ion beam irradiation above annealing temperature of $250^{\circ}C$ can be observed. Therefore, the good thermal stability and LC alignment for NLC by ion beam aligned NDLC thin films can be achieved.

Study on the Antimicrobial Substances of Lactic Acid Bacteria Isolated from Pig's intestine (돼지의 장에서 불리한 유산균의 항시균 활성물질에 관한 연구)

  • Seo, Jeong-Yong;Chung, Myung-Hee;Kim, Young-Jun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.4
    • /
    • pp.59-65
    • /
    • 2009
  • The antimicrobial activity-possessing materials were screened in the cell free supernatant (CFS) of fourteen lactic acid-fermenting strains isolated from pig's intestine. Each cell free supernatant of cultured strains was treated with various proteinases, heat, and/or alkali (NaOH). The antimicrobial activities were remained even after the enzyme and heat treatment but disappeared after neutralization with 1M NaOH, implying that the materials would be organic acids rather than proteins. Further purification of CFS through solid phase extraction using Sep-pak $C_{18}$ Cartridges and high performance anion exchange chromatography using Bio-LC system revealed that four organic acids, such as oxalic acid, citric acid, lactic acid, and acetic acid, were the main materials for the activity. Lactic acid was the highest amount in all organic acids, ranging from 54% to 77%. This strongly implies that the lactic acid would be the primary material for the antimicrobial activity in all tested strains.

  • PDF

Analytical trend of perfluorinated compounds in environmental and biota samples (환경 및 생체시료 중 과불화 화합물의 분석 동향)

  • Lee, Won-Woong;Chang, Won-Hee;Pyo, Hee-Soo;Kang, Tae-Seok;Hong, Jong-Ki
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.331-346
    • /
    • 2010
  • Perfluorinated compounds have characteristics of resistance to heat, acidic, basic conditions and also resist water, oil, grease, pollutant. Futhermore they are used by various industrial material, nowadays, they produced in large scale for indutrial and commercial areas. However, they also resist metabolizing and degrading in environmental system (plant, animal, even human body). Moreover, in animal's bodies, PFCs can be accumulated in organ (eg; liver) and lead to liver cell necrosis even oncogenesis. Perfluorinated compounds are newly registered as new persistent organic pollutants (POPs) on Stockholm convention in 2009. Therefore necessity for analytical methodology for determination of PFCs in various environmental samples is even more increased. This study discussed sample preparation and instrumental conditions for the analysis of PFCs in environmental and biota samples.

Evaluation of ginsenoside bioconversion of lactic acid bacteria isolated from kimchi

  • Park, Boyeon;Hwang, Hyelyeon;Lee, Jina;Sohn, Sung-Oh;Lee, Se Hee;Jung, Min Young;Lim, Hyeong In;Park, Hae Woong;Lee, Jong-Hee
    • Journal of Ginseng Research
    • /
    • v.41 no.4
    • /
    • pp.524-530
    • /
    • 2017
  • Background: Panax ginseng is a physiologically active plant widely used in traditional medicine that is characterized by the presence of ginsenosides. Rb1, a major ginsenoside, is used as the starting material for producing ginsenoside derivatives with enhanced pharmaceutical potentials through chemical, enzymatic, or microbial transformation. Methods: To investigate the bioconversion of ginsenoside Rb1, we prepared kimchi originated bacterial strains Leuconostoc mensenteroides WiKim19, Pediococcus pentosaceus WiKim20, Lactobacillus brevis WiKim47, Leuconostoc lactis WiKim48, and Lactobacillus sakei WiKim49 and analyzed bioconversion products using LC-MS/MS mass spectrometer. Results: L. mesenteroides WiKim19 and Pediococcus pentosaceus WiKim20 converted ginsenoside Rb1 into the ginsenoside Rg3 approximately five times more than Lactobacillus brevis WiKim47, Leuconostoc lactis WiKim48, and Lactobacillus sakei WiKim49. L mesenteroides WIKim19 showed positive correlation with b-glucosidase activity and higher transformation ability of ginsenoside Rb1 into Rg3 than the other strains whereas, P. pentosaceus WiKim20 showed an elevated production of Rb3 even with lack of b-glucosidase activity but have the highest acidity among the five lactic acid bacteria (LAB). Conclusion: Ginsenoside Rg5 concentration of five LABs have ranged from ${\sim}2.6{\mu}g/mL$ to $6.5{\mu}g/mL$ and increased in accordance with the incubation periods. Our results indicate that the enzymatic activity along with acidic condition contribute to the production of minor ginsenoside from lactic acid bacteria.

A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base (광중합형 이장재와 금속의치상 간의 결합력에 관한 연구)

  • Park, In-Chae;Lee, Joon-Kyu;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.3
    • /
    • pp.211-220
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recommendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univesal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strength than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strength of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base (광중합형 이장재와 금속의치상 간의 결합력에 관한 연구)

  • Park, In-Chae;Lee, Joon-Kyu;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.161-170
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recomendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univasal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strengths than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strengths of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

A STUDY ON THE RADIOPACITY OF GLASS IONOMER CEMENTS (Glass Ionomer Cement의 방사선 불투과성에 관한 연구)

  • Park, Soo-Kyeong;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.122-132
    • /
    • 1993
  • The aim of this study was to investigate the level of radiopacity of glass ionomer cements and to determine the optimum level of radiopacity that is the most compatible with the radiographic diagnosis of secondary caries. The experiments were performed in two parts. In the first part, the radiopacities of 9 glass ionomer cements (FI, FII, FI-LC, FII-LC, SI, SII, Vit, B-VLC, AC) and base materials(Ultra-Blend, Zinc phoaphate cements, Cavitec, Dycal) were measured by densitometer. Then all experimental materials were divided into 5 groups based on the level of radiopacity of enamel and dentin. In the second part, class III cavities with or without secondary caries were prepared in extracted anterior teeth. The representative materials of each group with different radiopacities were inserted into each cavity. The radiographs were interpreted by 15 dentists and seconsary caries were diagnosed according to a five-point confidence rating. Sensitivity and ROC analysis were used to compare observer performance. The following results were obtained : 1. The radipacity of glass ionomer cements varied between 1.111mm Al and 6.011mm Al equivalent. 2. Among experimental materials, three materials in group I had lower radiopacity than that of dentin. The radiopacity of two materials in group II slightly exeeded that of dentin. Three materials in group III had slightly lower radiopacity than that on enamel. The radiopacity of one material in group W was slightly higher than that of enamel. Four materals in group V had the radiopacity that exeeded over 2.0mm AI equivalent to that of enamel. 3. The group IV was the highest for sensitivity and the group V was the highest for ROC area. However, no significant differences were obtained among group II, III, IV and V (P<0.05) but only group I was significantly lower(P<0.01). 4. In comparison with the observer performance for the radiographic diagnosis of secondary caries, the group II, III, IV, and V were superior to the group I (P<0.01). And so the optimum level of radiopacity to detect the secondary caries was the radiopacity that is higher than that of dentin.

  • PDF

Quantification of cholesterol in human serum by isotope dilution liquid chromatography/mass spectrometry (동위원소희석 액체크로마토그래피/질량분석법에 의한 혈청 내 콜레스테롤의 정량)

  • Shin, Hyesun;Lee, Hwashim;Lee, Gaeho
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.502-509
    • /
    • 2008
  • An ID LC/MS (isotope dilution liquid chromatography/mass spectrometry) was used as a primary method for the quantitative analysis of cholesterol in human serum. The separation of cholesterol was carried out by Thermo ODS hypersil $C^{18}$ column. The mobile phase was 100% methanol, and flow rate was $0.3m{\ell}/min$. Cholesterol and cholesterol-$3,4-13C_2$ were monitored at m/z 369.4 and 371.3, which correspond to $[M-H_2O+H]^+$ respectively. In order to verify the measurement method, NIST SRM 909b was analyzed. The results agreed well with certified values within uncertainty. The four kinds of serum certified reference material were prepared and certified. The repeatabilities of measurement were ranged from 0.1 to 0.8% (RSD), which were relatively good. The reproducibility between independent measurement run was below 0.24% (RSD). The expanded uncertainty was about 1.43% within the 95% confidence interval.

LC-MS Analysis According to the Combined Treatment of Paenibacillus yonginensis DCY84T and Silicon in Rice

  • Yo-Han Yoo;Mee Youn Lee;Yeon-Ju Kim;Eok-Keun Ahn;Ki-Hong Jung
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.232-232
    • /
    • 2022
  • We reported in our recent studies that the combined treatment of Paenibacillus yonginensis DCY84T (DCY84T) and Silicon (Si) promotes initial plant growth and increases resistance to biotic and abiotic stress. To understand the molecular background of these phenotypes, Liquid Chromatography Mass Spectrometry (LC-MS) analysis was performed, and it was confirmed that unsaturated fatty acid metabolites such as oleic acid and linoleic acid decreased in response to the combined treatment of DCY84T and Si. The stearoyl-acyl carrier protein desaturase (SACPD) introduces the cis double bond into the acyl-ACPs at C9, resulting in the production of unsaturated fatty acid. We identified OsSSI2 encoding SACPD in rice and found that the expression of OsSSI2 was reduced under DCY84T and Si treatment. Furthermore, qRT-PCR analysis revealed that the expression of OsWRKY45, which is downstream of OsSSI2, was upregulated in response to DCY84T and Si treatment. These results enable the speculation that activation of the salicylic acid (SA)-responsive gene, OsWRKY45, may contribute to enhancing biological stress resistance. Based on this, we propose a probable model for the rice defense pathway following DCY84T and Si treatment. This model retains a WRKY45-dependent but NH1(NPR1)-independent SA signaling pathway.

  • PDF

Noninvasive measuring;Detections of materials and quantities on eddy current testing

  • Obayashi, Koji;Tamura, Muneyoshi;Zhang, X.;Aoyama, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1555-1560
    • /
    • 2004
  • We made a simplified eddy-current-tester, and observed some materials for the ingredients and mass and locations. The tester detects the current as frequency shifts of a LC-resonance circuit, which are caused by the eddy currents. Using air-wick coil and a multi-piled ceramic capacitor, we made a resonance system whose frequency was 100KHz. The shift quantity is few; so, to detect it, we used a frequency counter, and counted the shift. We can detect 10Hz order's shift.

  • PDF