• Title/Summary/Keyword: LC filter

Search Result 277, Processing Time 0.023 seconds

Design of Digital Controller for Output Voltage Control of LC Filter in 3-Phase UPS (UPS용 인버터의 LC필터 출력 전압제어를 위한 디지털 제어기 설계)

  • 조준석;이승요;최규하;목형수;신우석;한석우
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.75-80
    • /
    • 1998
  • This paper presents an observer filter algorithm to estimated the load currents in the output voltage control of 3-phase uninterruptible power supply with deadbeat controller. As the result of the proposed algorithm, the sensors to measure the load currents is not required. The comparison of output voltage controls according to the methods of measuring the load currents is also presented in this paper. The results of comparison are shown by the simulation.

  • PDF

LC Filter Design Limiting Voltage Slew Rate (전압 상승률을 기반으로 하는 인버터의 출력 필터 설계)

  • Choi, Young-Hyun;Choi, Hyeon-Gyu;Ha, Jung-Ik
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.331-332
    • /
    • 2016
  • 본 논문에서는 PWM 슬루율을 제한하기 위한 LC 필터 설계를 제안한다. 기존의 연구에서는 PWM 입력전압과 필터링된 출력 전압에 대한 주파수 분석을 통해 출력단에 나타나는 슬루율을 제한하였다. 하지만 이러한 분석은 순시 출력 슬루율을 정량적으로 분석하기 어렵다. 본 논문에서는 LC필터의 출력 슬루율을 시간 영역에서 분석하고, 이를 제한하는 LC 필터의 정량적인 설계법을 제시한다.

  • PDF

Output LC Filter Design of Three Phase Voltage Source Inverter Considering the Performance of Controller (제어기 응답을 고려한 삼상 전압형 인버터의 출력 LC필터 설계)

  • 최재호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.748-751
    • /
    • 2000
  • in this paper the design procedure of three phase voltage source inverter output filter is described. The 'd' axis transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant including the controller. This means that the relation between the filter capacitor value and the system time constant is given as the closed form. By using the above closed form the capacitor value can be calculated with the system time constant is given as the closed,. form the capacitor value can be calculated with the system time constant which can be implemented practically not using the try and error method. And as the effect of the load is connected.

  • PDF

Output LC Filter Design of Voltage Source Inverter Considering the Performance of Controller (제어기응답을 고려한 전압형 인버터의 출력 LC필터 설계)

  • Kim, Jae-Sig;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1077-1079
    • /
    • 2000
  • In this paper. the design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant including the controller. This means that the relation between the filter capacitor value and the system time constant is given as the closed form. By using the above closed form. the capacitor value can be calculated with the system time constant which can be implemented practically not using the try and error method. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it can be verified how much the voltage distortion is effected when the nonlinear load is connected.

  • PDF

A Study on compensation of Frequency Distortion of SCF by Using Prewarping Procedure (Prewarping법을 이용한 SCF의 주파수 #곡 보상에 관한 연구)

  • 최민호;김도현
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.5
    • /
    • pp.69-74
    • /
    • 1985
  • In this paper five-order Butterworth Low pass active RC filter is designed by using FDNR (Frequency Dependent Ncgative Resistor) Method from LC ladder filter having the lowest sensitivity. In process of Transformation to SCF (Switched Capacitor Filter) from active RC filter, Bilinear Z Transfomation method is utilized. By the design of SCF using the bilinear Z transform method the problem of aliasing can be avoided, but the frequency distortion is generated. The transformation from analog filter to digital filter is not equal in the region of the cut off frequency caused by this effect. Avoiding the problem of this effect, we use prewarping method. The result shows that the prewarped SCF makes more remarkable improvement in the frequency distortion than SCF which is transformed by using bilinear Z transform.

  • PDF

Simple High Power Factor Three Phase Rectifier with Elimination of DC Link LC Filter (DC 링크의 LC 필터를 제거한 3상 고역률 정류기)

  • Kim, J.H.;Kim, Y.C.;Koo, H.G.;Lee, H.W.;Song, D.I.;Cho, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2237-2239
    • /
    • 1997
  • The conventional three phase rectifier with Bulk LC output filter has been widely used in the industry because of simple circuit, low cost and high power factor (90%). One of the biggest drawback of this rectifier is bulky and havy. This is serious especially for aerospace applications. To solve this problem a new simple rectifier is presented. Operation of the proposed rectifier is illustrated and verifyed by PSpice simulation.

  • PDF

Two-Stage Surge Protection Device with Varistor and LC Filter. (바리스터와 LC필터를 사용한 2단 서지보호장치)

  • Lee, B.H.;Kim, J.H.;Lee, K.O.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.279-281
    • /
    • 1996
  • This paper deals with the two stage surge protection device by using varistor and LC low pass filter. Recently varistor alone has been used with overvoltage protection devices for the AC power mains and has same problems associated with high remnant voltage and noise. In this work, in order to improve the cutoff performance of surge protection device, the lightning surge protection device having two stage hybrid circuit for an AC single phase mains was designed and fabricated. Operation characteristics and surge clamping performance of the surge protection device in an $8/20{\mu}s$ surge current are investigated. As a consequence, it is found that the proposed two stage surge protective device for AC power mains has a variety of advantages such as a smaller clamping voltage, high frequency noise reduction and large clamping capacity.

  • PDF

A Voltage Inverter Switch With a New Clocking Scheme and its Application to Switched Capacitor Filter Design (새로운 Clocking 방식에 의한 Voltage Inverter Switch 및 Switched Capacitor Filter 설계에의 응용)

  • 이방원;박송배
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.4
    • /
    • pp.1-11
    • /
    • 1981
  • This paper proposes a method of generalizing the clocking scheme in the Switched Capacitor Filter(SCF) design using Voltage Inverter Switches (VIS's). Parallel RC and RL elements, and parallel LC resonators can be implemented by the proposed clocking schemes Applying these new elements and the generalized clocking schemes to the SCF design, the total number of required operational amplifiers and capacitors can be reduced. Experimental results of a band- stop filter and a low-pass filter using a new type grounded VIS show good agreements with t he theoretical characteristics.

  • PDF

High Power Factor Three Phase Rectifier for High Power Density AC/DC Conversion Applications

  • Cho, J.G.;Jeong, C.Y.;Baek, J.W.;Song, D.I.;Yoo, D.W.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.648-653
    • /
    • 1998
  • The conventional three-phase rectifier with bulky LC output filter has been widely used in the industry because of its distinctive advantages over the active power factor correction rectifier such as simple circuit, high reliability, and low cost. Over than 0.9 power factor can be achieved, which is acceptable in most of industry applications. This rectifier, however, is not easy to use for high power density applications since the LC filter is bulky and heavy. To solve this problem, a new simple rectifier is presented in this paper. By eliminating the bulky LC filter from the conventional diode rectifier without losing most of the advantages of the conventional rectifier, very high power density power conversion with high power factor can be achieved. Operation principle and design considerations are illustrated and verified by Pspice simulation and experimental results from a prototype of 3.3 kW rectifier followed by 100KHz zero voltage switching full bridge PWM converter

  • PDF

Droplet Size Distribution Effect on the Electro-Optical Properties of Emulsion Type Polymer Dispersed Liquid Crystal (에멀전 방식의 고분자 분산형 액정의 전기 광학 특성에 미치는 액적 크기 분포의 영향)

  • Yoo, Hee Sang;Oh, Nam-Seok;Yan, Jin;Kwon, Soon-Bum
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.7
    • /
    • pp.439-445
    • /
    • 2015
  • We established the emulsion method using membrane filter with precise control of LC droplet distribution in PDLC. PDLC cells with various LC droplet size distributions such as single droplet sizes of $1.0{\mu}m$, $1.9{\mu}m$ and $3.5{\mu}m$, the mixture of two different LC droplet sizes and the mixture of three different LC droplet sizes were fabricated and the electro-optical properties of the emulsion type PDLC cells with various droplet size distribution were investigated. In the appropriate droplet size range, the PDLCs with the single droplet sizes distributions have good electro optical properties than those with the mixture of three different LC droplet sizes. In addition, the PDLC cells with the mixture of two different LC droplet sizes have the better electro optical properties than those with single droplet sizes distribution. The PDLC cell with dual droplet size distribution of $1.0+1.9{\mu}m$ shown the best electro optical properties than the PDLC cells with other size distributions. This method enabled us to find the proper LC droplet size distribution for achieving both high transmittance and contrast ratio.