• Title/Summary/Keyword: LC/MS analysis

Search Result 747, Processing Time 0.04 seconds

Determination of perchlorate in the Gum-River surface water by LC-ESI-MS/MS (금강 지표수에서 LC-ESI-MS/MS에 의한 염소산이온의 극미량 분석)

  • Lee, Young Joon;Lee, Jun Bae;Hong, Seon Haw;Kim, Hyun-Ji;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.435-440
    • /
    • 2012
  • A liquid chromatography-electrospray ionization-tandem mass spectrometry method (LC-ESI-MS/MS) was used for determining perchlorate in the Gum-River surface water. Sample was directly injected into LC-ESI-MS/MS after the filtrations using PTFE filter paper. The coefficient of variation of perchlorate was less than 3% and the limit of quantification was 0.17 ${\mu}g/L$. Water samples were collected from thirty-five basins of Gum-River on February, April and June 2012, respectively. As a result, perchlorate was detected in the concentration range of 0.23-3.73 ${\mu}g/L$ (mean 0.20 ${\mu}g/L$) in the frequency of 15% in general surface water and in the concentration range of 0.36-25.10 ${\mu}g/L$ (mean 1.69 ${\mu}g/L$) in the frequency of 36% in surface water samples near industry area.

Optimization of Solid Phase Extraction Method for Quantitative Analysis of Perfluorooctanoic Acid in Serum using Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Hyun-Seok;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • v.5 no.1
    • /
    • pp.30-33
    • /
    • 2014
  • A solid phase extraction (SPE) method was optimized for the quantitative analysis of perfluorooctanoic acid (PFOA) in serum using hydrophilic-lipophilic balance SPE and LC-MS/MS. Fetal bovine serums spiked with $^{13}C_8$-PFOA before or after SPE were used as test samples for evaluation of the SPE efficiency. Simultaneous evaluation of matrix effects and absolute SPE recovery for $^{13}C_8$-PFOA in serum using different sample pre-treatments and SPE conditions allowed optimization of SPE process efficiency with minimal matrix effect and decent SPE recovery. Introduction of protein precipitation as a sample pre-treatment procedure for serum samples before SPE generally decreased matrix effect in LC-MS/MS analysis and provided more stable recovery of PFOA.

Analysis of Methionine Oxidation in Myosin Isoforms in Porcine Skeletal Muscle by LC-MS/MS Analysis

  • Jeong, Jin-Yeon;Jung, Eun-Young;Jeong, Tae-Chul;Yang, Han-Sul;Kim, Gap-Don
    • Food Science of Animal Resources
    • /
    • v.36 no.2
    • /
    • pp.254-261
    • /
    • 2016
  • The purpose of this study was to analyze oxidized methionines in the myosin isoforms of porcine longissimus thoracis, psoas major, and semimembranosus muscles by liquid chromatography (LC) and mass spectrometry (MS). A total of 836 queries matched to four myosin isoforms (myosin-1, -2, -4, and -7) were analyzed and each myosin isoform was identified by its unique peptides (7.3-13.3). Forty-four peptides were observed from all three muscles. Seventeen peptides were unique to the myosin isoform and the others were common peptides expressed in two or more myosin isoforms. Five were identified as oxidized peptides with one or two methionine sulfoxides with 16 amu of mass modification. Methionines on residues 215 (215), 438 (438), 853 (851), 856 (854), 1071 (1069), and 1106 (1104) of myosin-1 (myosin-4) were oxidized by the addition of oxygen. Myosin-2 had two oxidized methionines on residues 215 and 438. No queries matched to myosin-7 were observed as oxidized peptides. LC-MS/MS allows analysis of the oxidation of specific amino acids on specific residue sites, as well as in specific proteins in the food system.

Establishment of a Method for the Analysis of Diarrhetic Shellfish Poisoning by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS를 이용한 설사성패류독소의 분석조건 확립)

  • Lee, Ka-Jeong;Suzuki, Toshiyuki;Kim, Poong-Ho;Oh, Eun-Gyoung;Song, Ki-Cheol;Kim, Ji-Hoe
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.4
    • /
    • pp.458-463
    • /
    • 2009
  • To establish and validate a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the rapid and accurate quantitation of diarrhetic shellfish poisoning (DSP) toxins, we compared the results from different mobile phases and columns used for their analysis and collision energies for MS/MS experiments. Clear peaks of okadaic acid (OA) and dinophysistoxin-1 (DTX1) were obtained by using a mobile phase comprising aqueous acetonitrile containing 2 mM ammonium formate and 50 mM formic acid. The collision energies were optimized to facilitate the most sensitive detection for each toxin, namely, OA, DTX1, pectenotoxin-2 (PTX2), or yessotoxin (YTX). Further, the maximum ion response was obtained at a collision energy of 48 V for OA and DTX1. We compared the analytical performance of $C_8$ and $C_{18}$ columns. A wide range of toxins namely, OA, DTX1, PTX2, and YTX, except DTX3, were detected by both the columns. Although DTX3 was only detected by the $C_8$ column, we found that the $C_{18}$ column was also suitable for the quantitation of OA and DTX1 the toxins responsible for inducing diarrhea. The limit of detection of OA and DTX1 by the established LC-MS/MS conditions was 1 ng/g, and the limit of quantitation of the toxins under the same conditions was 3 ng/g. The process efficiencies were 91-118% for oysters (Crassostrea gigas) and 96-117% for mussels (Mytilus galloprovincialis) further, we observed no significant effect of matrix during the ionization process in LC-MS/MS. The comparison between mouse bioassay (MBA) and LC-MS/MS yielded varying results because low concentrations of OA and DTX1 were detected by LC-MS/MS in some shellfish samples, which provided positive results on MBA for DSP. The analysis time required by MBA for DSP analysis can be reduced by LC-MS/MS.

Analysis of Gingerol Compounds of Raw Ginger (Zingiber officinale Roscoe) and Its Paste by High Performance Liquid Chromatograph-Mass Spectrometry (LC/MS) (LC/MS에 의한 원료생강 및 생강 페이스트 중의 Gingerol 화합물 분석)

  • 조길석
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.5
    • /
    • pp.747-751
    • /
    • 2000
  • This study was carried out to improve the analysis method of gingerol compounds from ginger (Zingiber officinale Roscoe). Pungent components of ginger were extracted by acetone and lisolated by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC) with LiChrosorb RP-18 column. Three homologues of gingerols were identified by HPLC-mass spectrometry (LC/MS) and nuclear magnetic resonance (NMR). The contents of [6]-, [8]- and [10]-gingerols in three homologues identified were 635.3 mg%, 206.6 mg% and 145.7 mg% in raw ginger, and were 418.2 mg%, 142.6 mg% and 103.3 mg% in ginger paste, respectively.

  • PDF

Identification of Novel Metabolic Proteins Released by Insulin Signaling of the Rat Hypothalmus Using Liquid Chromatography-Mass Spectrometry (LC-MS)

  • Chin, Chur
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.6
    • /
    • pp.470-474
    • /
    • 2007
  • Objective : The brain is dependent on glucose as an energy source. Intricate homeostatic mechanisms have been implicated in maintaining the blood glucose concentration in the brain. The aim of this study is to find the way to identify the metabolic proteins regulating the glucose in rat hypothalamus. Methods : In this study, we analysed the secretome from rat hypothalamus in vivo. We introduced 500 nM of insulin into the rat hypothalamus. The chromatographic patterns of the secretome were identified, after which Mass Spectrometry-Mass Spectrometry (MS-MS) analysis was performed. Results : In Liquid Chromatography-Mass Spectrometry (LC-MS) analysis, 60 proteins were identified in the secretome. Among them, 8 novel proteins were unveiled and were associated with the energy metabolism of insulin signaling in mitochondria of rat hypothalamic neuron. Nineteen other proteins have unknown functions. These ligands were confirmed to be secreting from the rat hypothalmus on insulin signaling by western blotting. Conclusion : The hypothalamus is the master endocrine gland responsible for the regulation of various physiological and metabolic processes. Proteomics using LC-MS analysis offer a efficient means for generating a comprehensive analysis of hypothalamic protein expression by insulin signaling.

Analysis of Carbonyl Compounds using DNPH Cartridge with LC-MS (DNPH cartridge/LC-MS 방법에 의한 카르보닐화합물 분석에 관한 연구)

  • Cho Deok-Hee;Song Il-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.2
    • /
    • pp.201-208
    • /
    • 2006
  • Several carbonyl compounds are important because of their irritant and toxic properties, mutagenicity and carcinogenicity. Therefore, they are regulated in korean odor emission standard. In this study, atmospheric pressure ionization-mass spectrometry(API-MS) is used for the analysis of carbonyl compounds after derivatization with 2, 4-dinitrophenylhydrazine (DNPH) and liquid chromatographic separation. In the negative ion mode, the $[M-H]^-$ pseudomolecular ions are most abundant for the carbonyls. Analytical parameters such as linearity, repeatability and minimum detection limit were evaluated. The linearities ($r^2$) for carbonyls were $0.9977{\sim}0.9999$ when analyte concentration ranges from $25\;to\;250{\mu}g/L$(n=6). The relative standard deviations (%RSD) for carbonyls were $0.55{\sim}3.51%$ for concentration of $100{\mu}g/L$(n=5). The minimum detection limit (MDL) was $1.88{\mu}g/L$(0.27 ppb) for i-valeraldehyde. It was shown that LC-MS method has a great potential for carbonyl compounds analysis.

Determination of Total Aflatoxins in Foods by Parallelism of ELISA and LC/MS/MS (ELISA-LC/MS/MS 병행에 의한 식품 중 aflatoxins 분석)

  • Kim, Kyeong-Yeol;Nam, Min-Ji;Nam, Bo-Ram;Ryu, Hee-Jung;Song, Jeong-Eon;Shim, Won-Bo;Lee, Soo-Hyung;Chung, Duck-Hwa
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.1
    • /
    • pp.52-60
    • /
    • 2010
  • High performance liquid chromatography (HPLC) and liquid chromatography mass spectrometry (LC/MS) have been widely used to quantify aflatoxins in food, but these methods are expensive, time-consuming, unsuitable for analysis of the routine screening of large sample numbers and require derivatization and high level techniques to perform. The objective of this study is to detect aflatoxins in a large number of foods by a high efficient analytical system of combined enzyme linked immunosorbent assay (ELISA) for screening and LC/MS/MS for confirmation. The samples spiked individually with aflatoxin $B_1$ (0.5 and 1.0 ng/g) and total aflatoxins (10 ng/g) were analyzed by ELISA and LC/MS/ MS, and the recoveries for ELISA and LC/MS/MS were 71.8~119.2% and 70.8~135.3%, respectively. A total of 378 samples (grains, nuts, soybean and fermented soybean foods, pepper and fermented pepper foods) were purchased from the six major cities in Korea and analyzed by ELISA-LC/MS/MS system. Twenty two (5.8%; peanut: 11, pistachio: 2, walnut: 6, almond: 1, pepper powder: 1, pepper paste: 1) out of 378 samples were screened as aflatoxin B1 positive by ELISA, but, 4 (1.1%; peanut: 2, pistachio:1, pepper powder: 1) out of the 22 samples screened were confirmed as aflatoxins positive at levels of 1.02~52.79 ng/g by LC/MS/MS. ELISA-LC/MS/MS system provides a more rapid, accurate and cost-effective method for the detection of aflatoxins in large number of samples.

Development Rapid Analytical Methods for Inositol as a Trace Component by HPLC and LC-MS/MS in Infant Formula

  • Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.35 no.4
    • /
    • pp.466-472
    • /
    • 2015
  • A rapid and simple analytical method, using liquid chromatography tandem mass spectrometry (LC-MS/MS), was developed to detect myo-inositol (MI) in infant formulas. For protein removal: acid hydrolysis and lipid removal through organic solvent extraction. The operating conditions for instrumental analysis were determined based on previously reported analogous methods that used LC-MS/MS. Quantitative analysis was used for the detection limit test, infant formula recovery test, and standard reference material (SRM) 1849a to verify the validity of our LC-MS/MS analytical method, which was developed to quantify MI. For validation, the results of our method were compared with the results of quantitative analyses of certified values. The test results showed that the limit of detection was 0.05 mg/L, the limit of quantitation was 0.17 mg/L, and the method detection limit was 17 mg/kg. The recovery test exhibited a recovery between 98.07-98.43% and a relative standard deviation between 1.93-2.74%. Therefore, the result values were good. Additionally, SRM 1849a was measured to have an MI content of 401.84 mg/kg and recovery of 98.25%, which is comparable to the median certified value of 409 mg/kg. From the aforementioned results, we judged that the instrumental analysis conditions and preparation method used in this study were valid. The rapid analytical method developed herein could be implemented in many laboratories that seek to save time and labor.

Analysis of Heterocyclic Amines in Mainstream Cigarette Smoke using by LC-MS/MS (LC-MS/MS를 이용한 담배 연기 중 Heterocyclic Amines의 분석)

  • Kim, Ick-Joong;Jang, Gi-Chul;Ji, Sang-Un;Min, Hye-Jeong;Kim, Hyo-Keun;Hwang, Geon-Jung
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.30 no.1
    • /
    • pp.33-38
    • /
    • 2008
  • This study was carried out to determine the analytical methods for heterocyclic amines(HAs) of the tobacco smoke by LC/MS/MS. HAs have been found in pyrolysate of protein and cooked food including protein, were known the Sugimura compound. HAs content of the smoke were known to exist very low ppb level. Especially, some of HAs are mutagenic and carcinogenic compounds. In according to IARC, the toxicity of N-heterocyclic amines classified IARC class 2A or 2B group. Precursors of these compounds are glutamic acid, protein and free amino acids including tryptophan, therefore, the precursors have been proved in cooked food continuously. This study was investigate multiple analysis methods for HAs and HAs contents of some commercial products. In this study, we used the linear type smoking machine for HAs analysis. At the ISO conditions, mainstream smoke was collected on cambridge filter pad, and then cambridge filter pad was extracted by 0.1% acetic acid. The extracted solution were passed cation exchange SPE cartridge to remove matrix, samples were analyzed using LC/MS/MS on MRM mode. From the result that optimized this methods, the correlation coefficient(R) of the individual compounds were good linearity over 0.999, recovery rate over 96% and the limit of detection were good values between 0.06 to 0.37 ng/mL, In addition, HAs content of some commercial products were in range of 0.02 to 43.8 ng/cig.