• 제목/요약/키워드: LASER

검색결과 14,336건 처리시간 0.033초

생쥐 수정란의 보조부화술에 있어서 Non-Contact Type인 Diode Laser의 이용 (Use of Non-Contact Type Diode Laser on Assisted Hatching of Mouse Embryos)

  • 김동훈;이명섭;강희규;한성원;김묘경;박원일;이훈택;정길생;이호준
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제26권2호
    • /
    • pp.185-192
    • /
    • 1999
  • The present study was performed to investigate the efficacy and safety of laser assisted hatching (AH) on mouse embryos. Non-contact $1.48{\mu}m$ diode laser system used to create a precise hole on zona pellucida. 2-cell embryos were collected from the mice (ICR) that had the coitus vaginal plug confirmed at 48 hours after hCG injection. Collected 2-cell embryos were cultured in the HTF medium supplemented with 0.4% BSA. For experiments, embryos at 8-cell stage were used after 18-22 hours in culture. After assisted hatching, the embryos were further cultured in HTF medium containing 0.1% PVP (anti-hatching system) for 3 days. For evaluate efficiency of laser on mouse embryo hatching, the effect of AH methods (acidic tyrode, pronase and laser), the number of artificial holes (1, 2 and 3 hole) and the irradiation time of laser (2, 4, 6, 8 and 10 ms) were examined. Hatching rates of laser AH group (95.2%) was significantly higher than that of control group (50.8%), but there was no differences among the laser (95.2%), acidic tyrode (100%) and pronase (98.5%) groups. Hatching rates of the number of zona pellucida opening by laser, there were no differences among the 1 hole (87.5%),2 hole (92.1%) and 3 hole (85.9%) groups. Developmental and hatching rates of embryos according to laser irradiation time were similar in the treatment groups. Therefore, these results suggest that laser AH using non-contact $1.48{\mu}m$ diode laser is a simple and accurate and effective procedure for AH. Based on these results, laser AH could be use safely for human ART program.

  • PDF

세슘 원자에 대한 레이저 냉각 및 온도 측정 (Laser cooling and temperature measurement of cesium atoms)

  • 권택용;이호성;양성훈
    • 한국광학회지
    • /
    • 제11권6호
    • /
    • pp.379-384
    • /
    • 2000
  • 레이저 냉각법을 이용하여 세슘 원자의 온도를 도플러 냉각 한계온도 보다 낮은 온도까지 냉각하였다. 자기-광 포획된 원자를 더 냉각하기 위해서는 냉각용 레이저의 주파수를 더 적색편이 시켜야 하는데, 이를 위해 본 연구에서는 세슘 원자 흡수선의 Zeeman 이동을 이용하였다. 이 방법으로 레이저 주파수 안정화를 유지하면서 레이저의 주파수를 약 40MHz 만큼 이동시킬수 있었다. 비행시간 방법으로 측정한 레이저 냉각된 세슘원자의 최저온도는 $2.2\muK$\pm$0.5$\muK$이었다. 냉각된 원자의 온도를 레이저의 주파수 및 세기에 따라 측정하였는데, 이광자 냉각 이론에 의한 계산결과와 잘 일치한다는 것을 알았다.

  • PDF

Proposal and Analysis of Distributed Reflector-Laser Diode Integrated with an Electroabsorption Modulator

  • Kwon, Oh Kee;Beak, Yong Soon;Chung, Yun C.;Park, Hyung-Moo
    • ETRI Journal
    • /
    • 제35권3호
    • /
    • pp.459-468
    • /
    • 2013
  • A novel integrated laser, that is, a distributed reflector laser diode integrated with an electroabsorption modulator, is proposed to improve the output efficiency, single-mode stability, and chirp. The proposed laser can be realized using the selective metalorganic vapor phase epitaxy technique (that is, control of the width of the insulating mask), and its fabrication process is almost the same as the conventional electroabsorption modulated laser (EML) process except for the asymmetric coupling coefficient structure along the cavity. For our analysis, an accurate time-domain transfer-matrix-based laser model is developed. Based on this model, we perform steady-state and large-signal analyses. The performances of the proposed laser, such as the output power, extinction ratio, and chirp, are compared with those of the EML. Under 10-Gbps NRZ modulation, we can obtain a 30% higher output power and about 50% lower chirp than the conventional EML. In particular, the simulation results show that the chirp provided by the proposed laser can appear to have a longer wavelength side at the leading edge of the pulse and a shorter wavelength side at the falling edge.

The Waveform Model of Laser Altimeter System with Flattened Gaussian Laser

  • Ma, Yue;Wang, Mingwei;Yang, Fanlin;Li, Song
    • Journal of the Optical Society of Korea
    • /
    • 제19권4호
    • /
    • pp.363-370
    • /
    • 2015
  • The current waveform model of a laser altimeter is based on a Gaussian laser beam of fundamental mode, while the flattened Gaussian beam has many advantages such as nearly constant energy distribution on the center of the cross-section. Following the theory of the flattened Gaussian beam and the waveform theory of the laser altimeter, some of the primary parameters of the received waveform were derived, and a laser altimetry waveform simulator and waveform processing software were programmed and improved under the circumstance of a flattened Gaussian beam. The result showed that the bias between theoretical and simulated waveforms was less than 3% for every order mode, the waveform width and range error would increase as target slope or order number rose. Under higher order mode, the shapes of the received waveforms were no longer Gaussian, and could be fitted more precisely as a generalized Gaussian function with power bigger than 2. The flattened beam got much better performance for a multi-surface target, especially when the small surface is far from the center of the laser footprint. This article provides the waveform theoretical basis for the use of a flattened Gaussian beam in a laser altimeter.

적외선 레이저 다이오드가 콜라겐 형성에 미치는 영향 (The effect of infrared rays diode irradiation on collagen formation)

  • 김태곤;김영표;이호식;박용필;천민우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.411-411
    • /
    • 2009
  • Low level laser therapy has various therapy effects. This paper performed the basic study for developing the Low Level Laser Therapy Equipment for medical treatment. The apparatus has been fabricated using the laser diode and microprocessor unit. This equipment was fabricated using a micro-controller and a laser diode, and designed to enable us to control light irradiation time, frequency and so on. In this study, the designed device was used to find out how infrared laser diode affected the collagen formation. For in-vivo test, a round wound 1cm in diameter was cut from the test animal whose epidermal and dermal layers were removed. Test animals were relieved for 24 hours after wounds had been excised and then the infrared laser irradiation group was given irradiation therapy over 9 days one 20 min per day. As a result, More collagenosis occurred in the order of infrared laser irradiation and non-irradiation group. Collagenosis is closely related to wound repair and it was found that infrared laser irradiation groups had more collagenosis and was quicker to recover from wound than non-irradiation group.

  • PDF

CO2 레이저 보조가공에 의한 세라믹재료의 가공성에 관한 기초 연구 (The Basic Study on Machinability of Ceramics in CO2 Laser Assisted Machining)

  • 김종도;이수진;박서정
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권2호
    • /
    • pp.322-329
    • /
    • 2009
  • Machinability of LAM(Laser Assisted Machining) has been studied for ceramics such as $Al_2O_3$, $Si_3_N4$ and $ZrO_2$ by $CO_2$ laser. It was possible to remove ceramics by PCBN tool because material became softening and deterioration by local laser beam irradiation. The advantage of LAM is the ability to produce larger material removal rates and tool life. But, for cutting of $Al_2O_3$ and $ZrO_2$, stage of laser power control was needed owing to thermal shock with high temperature of workpiece by laser power. And when $Si_3N_4$ was machined by LAM, $N_2$ gas spouted from surface of one cause of high temperature. Characteristics of LAM were analyzed using pyrometer, dynamometer, SEM and EDS to measure temperature of workpiece surface, cutting force, variation of machining surface and structure of lattice respectively. As the result of this study, it was found that machinability of LAM for ceramics in $CO_2$ laser and mechanism of LAM was different according to the kind of ceramics because of properties of materials.

ZCS공진형 컨버터를 적용한 고반복 대출력 펄스형 Nd:YAG 레이저 전원장치 개발 (Development of high repetition rate and high power pulsed Nd:YAG laser power supply using ZCS resonant converter)

  • 조기연;김은수;변영복;김희제;박점문;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.514-517
    • /
    • 1996
  • Zero current switching(ZCS) series resonant converter is used to control laser power density in a pulsed Nd:YAG laser power supply. The high power and high repetition rate paused Nd:YAG laser is designed and fabricated to control current pulse width and pulse repetition rate in the double elliptical laser oscillator. In order to find out operational characteristics of pulsed Nd:YAG laser, the electrical properties of driving power supply and laser output power are investigated and experimented by changing of the current pulse width from 200uS to 350uS(step 50uS) and pulse repetition rate range of 500pps(pulse per second) to 1150pps. From that result, we obtaind maximum efficiency of 1.83% and maximum laser output or 220W at the condition of 350 uS and 1150pps with one Nd:YAG rod), and obtained that of more than 400W with two laser head connecting series.

  • PDF

아르곤 레이저의 소아치과에서의 임상적 적용 (CLINICAL APPLICATION OF ARGON LASER IN PEDIATRIC DENTISTRY)

  • 이미나;이상훈;김종철
    • 대한소아치과학회지
    • /
    • 제24권1호
    • /
    • pp.139-147
    • /
    • 1997
  • Argon laser used in this case report, is special in having two wavelength of 488, 514nm blue-green visible light spectrum. Blue light is used for composite resin polymerization and caries detection. Green light is used for soft tissue surgery and coagulation. Maximum absorption of this laser light occurs in red pigmentation such as hemoglobin. The argon laser may be well-suited for selective destruction of blood clots and hemangioma with minimal damage to adjacent tissues. Argon laser light penetrates tissue to the 1 mm depth, so its thermal intensity is lower than $CO_2$ laser light. Also, due to its short wavelength it can be focused in a small spot and even single gene can be excised by this laser and microscopy. After applicating argon laser to 4 patient for surgical procedure and to 1 patient for curing the composite resin, following results were obtained. 1. Improved visibility were gained due to hemostasis and no specific technique were needed according to easy recontouring of the tissue. 2. Ability to use by contact mode, tactile sense was superior but tissue dragability and accumulation of tissue on the tip needed sweeping motion. 3. Additive local anesthetic procedure was needed. 4. No suture and less curing time reduced chair time, this made argon laser available in pediatric dentistry.

  • PDF

고출력 연속파형 Nd:YAG 레이저를 이용한 CSP 1N 냉연강판 절단시 절단공정변수의 절단폭에 미치는 영향 (Influence of process parameters on the kerfwidth for the case of laser cutting of CSP 1N sheet using high power CW Nd:YAG laser)

  • 안동규;김민수;이상훈;박형준;유영태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.910-915
    • /
    • 2004
  • The objective of this study is to investigate the influence of process parameters, such as power of laser, travel speed of laser and material thickness, on the practical cutting region and the kerfwidth for the case of cutting of CSP 1N sheet using high power Nd:YAG laser with continuous wave(CW). In order to find the practical cutting region and the relationship between process parameters on the kerfwidth, several laser cutting experiments are carried out. The effective heat input is introduced to consider the influence of power and travel speed of laser on the kerfwidth together. From the results of experiments, the allowable cutting region and the relationship between the effective heat input and kerfwidth for the case of cutting of CSP 1N sheet using high power CW Nd:YAG laser have been obtained to improve the dimensional accuracy of the cut area.

  • PDF

광섬유를 이용한 레이저섬광의 균일분포 증진효과에 따른 열확산계수 측정에 관한 고찰 (A Study on Thermal Diffusivity Measurement by Improvement of Laser Flash Uniformity Using an Optical Fiber)

  • 이원식;배신철
    • 대한기계학회논문집B
    • /
    • 제22권8호
    • /
    • pp.1073-1082
    • /
    • 1998
  • When thermal diffusivity is measured by laser flash method, the thermal diffusivity call be calculated front the assumption of the uniformly heated whole surface of the specimen. It has been known that the approximate 5% error is made by the non-uniform energy distribution on the specimen surface of laser pulse heat source. In this study, to obtain the highly-uniformed laser beam, which has both the low non-uniform heating error from non-uniform laser beam and the energy loss, research was carried out on no transmitting loss by optical fiber and high repetitions. In addition, heating error and thermal diffusivity were measured as the measuring positions were varied and compared with the results using the uniform and the non-uniform laser beams. In addition, dole to using the uniformalized laser beam, the whole surface of the specimen was heated uniformly and as a result, it was the thought that this was very effective to reduce the variations of the errors of the thermal diffusivity as the measuring positions were varied. It can be obtained that when the thermal diffusivity of POCO-AXM-5Q1 of SRM in NBS was measured with both the uniform and the non-uniform laser beams, the dispersion error of the former was from 2 to 2.5%, which was more improved than that of the latter.