• Title/Summary/Keyword: LAMP

Search Result 2,684, Processing Time 0.036 seconds

A Study of High Efficiency Electrodeless lamp Properties (고효율 신광원 시스템의 특성에 관한 연구)

  • Kim, H.S.;Lee, S.H.;Shin, S.W.;Lim, J.M.;Huh, S.K.;Hwang, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1717-1720
    • /
    • 2002
  • Electrodeless discharge lamps have been objects of interest and research for several decades, mainly because of their potential for extremely long life, high lamp efficacies and smaller than standard fluorescent lamps size. A series of measurements and observations concerning variables has yielded optical and electrical characteristics for electrodeless discharge lamp like incandescent lamp and circular lamp feature. Last experiment were carried out to determine the lamp temperature at several surface points during operation. Light output levels in excess over 60,000 cd/$m^2$ have been measured in electrodeless discharge lamp for a general of conditions. At lamp surface temperatures have been measured over $80^{\circ}C$, and starting current have been measured over ${\sim}A$.

  • PDF

A Study for Optimal filling Condition in Outer Enclosure of Metal Halide Lamp (메탈 할라이드 램프 외관의 최적 봉착조건에 관한 연구)

  • Chee, Chol-Kon;Lee, Sung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.296-299
    • /
    • 1987
  • The purpose of this paper is to increase the lamp efficacy by filling the optimal Nitrogen gas pressure in the outer enclosure of metal halide lamp. This study presents a new model of Langmuir in the outer enclosure of discharge lamp. In this paper, in the first place, the diameter of Langmuir sheath and the total gab loss were calculated. Secondly, the each gas loss was computed if the arbitrary gas pressure is filled, With the calculated data, flash over which affects the lamp efficacy, lamp life and color rendering was considered. In case of the established discharge lamp, the gab pressure has been filled by experience only roughly. The gas loss is converted into the radiation output. Therefore, the lamp efficacy is improved by reducing the gas loss.

  • PDF

The Prevention of Melting Contact in Accordance Relay of Controller for Turn on/off High Pressure Sodium Vapor Lamp (고압 나트륨램프의 점등과 소등을 위한 제어기의 릴레이 접점의 융착 방지)

  • Han, Tae-Hwan;Woo, Chun-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.3
    • /
    • pp.148-151
    • /
    • 2004
  • For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in electric discharge tube, So accelerative electron collide against vapor atom and second electron is generated, And rapidly the current flow to electric discharge tube. This starting voltage is high voltage and source for melting contact that relay is according as turn on/off high pressure sodium vapor lamp. Consequently, This paper propose that the prevention of melting contact in accordance relay of controller for turn on/off high pressure sodium vapor lamp.

Comparison of Polymerase Chain Reaction, Real-time Polymerase Chain Reaction, and Loop-Mediated Isothermal Amplification for the Detection of Cronobacter sakazakii in Milk Powder (분유에 오염된 Cronobacter sakazakii 검출을 위한 중합효소연쇄반응, 실시간중합효소연쇄반응, 등온검출법의 비교)

  • Kim, Young-Joo;Seo, Sheungwoo;Wang, Xiaoyu;Seo, Dong Joo;Lee, Min Hwa;Son, Na Ry;Lee, Bog-Hieu;Choi, Changsun
    • Food Science of Animal Resources
    • /
    • v.33 no.5
    • /
    • pp.610-616
    • /
    • 2013
  • Loop-mediated isothermal amplification (LAMP) is an emerging detection technology for the amplification of DNA under isothermal conditions. The aim of this study was to develop a rapid and reliable LAMP technique for the detection of Cronobacter sakazakii in milk powder. In order to enhance the sensitivity and specificity, LAMP primers targeting outer membrane protein A (ompA) gene of C. sakazakii were designed using Explorer V4 software. Thirty seven C. sakazakii strains and 13 pathogenic microorganisms were used for comparative detection of C. sakazakii using polymerase chain reaction (PCR), real-time PCR, and LAMP. LAMP developed in this study could specifically detect C. sakazakii strains without cross-reactivity with other foodborne pathogens. LAMP products amplified from ompA gene of C. sakazakii were digested with with HhaI and NruI enzyme. The specificity of LAMP was confirmed by restriction fragment length polymorphism (RFLP) analysis. LAMP could detect C. sakazakii within 1 h without bacterial culture and its detection limit was as low as 1 CFU/mL C. sakazakii in milk. In the comparison of the sensitivity, LAMP showed 10,000- and 100-times higher detection limit than PCR or real-time PCR, respectively. Therefore, this study can conclude that LAMP is a rapid and reliable detection technique for C. sakazakii contaminated in powdered milk.

Transmittance Characteristics by candlepower of Incandescent Lamp (백열등의 광력에 따른 수중 투과특성)

  • 박성욱;배봉성;안희춘;이정우;서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.4
    • /
    • pp.293-299
    • /
    • 2002
  • The anchovy scoop net fishery is one of the important in the South sea and coastal of Jeju of Korea. They are using incandescent lamp as a fishing lamp at night to gather anchovy shoals in the water surface. Fishing lamp (AC 100 V 500 W$\times$2~3 or AC 100 V 1 ㎾$\times$1) was installed at 1 m ahead of the prow and 1.5 m height from the water surface. The fishing lamp let anchovy shoals rise to the water surface and are attracted to bag net. On this study, the distribution of submarine illumination of 1㎾ and 2 ㎾ incandescent lamp were analyzed and discussed to investigate the ability of fishing lamp which can gather anchovy shoals effectively. The submarine illumination of incandescent lamp showed peak in wave length 690 nm. The relationship between submarine illumination (L) and water depth (Z) of 1 ㎾ and 2 ㎾ incandescent lamp in vertical light is 1 ㎾ : L = 3851. 9 $e^{-1.4587Z}$ $R^2$=0.9952 2 ㎾ : L= 8211.9 $e^{-1.2852Z}$ $R^2$=0.9977 The submarine illumination of 2 ㎾ incandescent lamp of 0~4 m layers appeared to be 3 to 4 times higher than 1 ㎾ incandescent lamp, and in more deep layers than 6 m appeared to be equal value of each lamp. The light of incandescent lamp (1 ㎾) pass through much better into vertical direction than horizontal, and submarine illumination of 20 m layers was 1.0 l$\chi$. Therefore, fishing lamp power is thought that 1 ㎾ incandescent lamp is more efficient than 2 ㎾ to gather anchovy shoals in depth of 15~20 m to water surface.

The Study of Characteristic of Induced Erythema and Safety by UVB Lamp (UVB조사기의 홍반 발생 특성과 안전성에 관한 연구)

  • Park, Rae-Joon;Cho, Yong-Ho;Park, So-Hyun;Lee, Yoon-Mi
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.3
    • /
    • pp.79-87
    • /
    • 2006
  • Purpose: The present study purposed to examine induced characteristic or erythema and safety by medium wave ultra violet(UVB) lamp. Methods: We compared sunshine and UVB lamp using spectroradiometer and UV radiometer. For measuring sunshine irradiation, we used spectoradiometer and detected from 8 to 18 o'clock every each hour on the beach, playground and rooftop of a 5 story building. The subjects for erythema examination were 5 healthy subjects who have no pathologic history of photosensitivity reaction, psoriasis and vitiligo. They were exposed to UVB radiation at the abdominal area for 2 hours and after irradiation, we observed the change of skin color every 12 hours over a period of 1 week. Results: Between sunshine and UVB lamp, sunshine had higher data on the chromaticity coordinates, dominant and peak wavelength, bandwidth and purity than the UVB lamp but on the color temperature, brightness the UVB lamp had higher data than the sunshine. In comparison of sunshine and UVB lamp, UVB lamp irradiated constantly such as $3.9-4.4{\mu}W/cm^2$ at a distance of 100cm between bed and lamp which was same as early morning irradiation on the sunshine. The erythema didn't appear to any subject. Conclusion: This results suggest that the UVB lamp has lower irradiance as much as early sunshine. Therefore the UVB lamp had no influence of inducing erythema at a distance of 100cm between bed and lamp.

  • PDF

Development of an Improved Loop-Mediated Isothermal Amplification Assay for On-Site Diagnosis of Fire Blight in Apple and Pear

  • Shin, Doo-San;Heo, Gwang-Il;Son, Soo-Hyeong;Oh, Chang-Sik;Lee, Young-Kee;Cha, Jae-Soon
    • The Plant Pathology Journal
    • /
    • v.34 no.3
    • /
    • pp.191-198
    • /
    • 2018
  • Fast and accurate diagnosis is needed to eradicate and manage economically important and invasive diseases like fire blight. Loop-mediated isothermal amplification (LAMP) is known as the best on-site diagnostic, because it is fast, highly specific to a target, and less sensitive to inhibitors in samples. In this study, LAMP assay that gives more consistent results for on-site diagnosis of fire blight than the previous developed LAMP assays was developed. Primers for new LAMP assay (named as DS-LAMP) were designed from a histidine-tRNA ligase gene (EAMY_RS32025) of E. amylovora CFBP1430 genome. The DS-LAMP amplified DNA (positive detection) only from genomic DNA of E. amylovora strains, not from either E. pyrifoliae (causing black shoot blight) or from Pseudomonas syringae pv. syringae (causing shoot blight on apple trees). The detection limit of DS-LAMP was 10 cells per LAMP reaction, equivalent to $10^4$ cells per ml of the sample extract. DS-LAMP successfully diagnosed the pathogens on four fire-blight infected apple and pear orchards. In addition, it could distinguish black shoot blight from fire blight. The $B{\ddot{u}}hlmann$-LAMP, developed previously for on-site diagnosis of fire blight, did not give consistent results for specificity to E. amylovora and on-site diagnosis; it gave positive reactions to three strains of E. pyrifoliae and two strains of P. syringae pv. syringae. It also, gave positive reactions to some healthy sample extracts. DS-LAMP, developed in this study, would give more accurate on-site diagnosis of fire blight, especially in the Republic of Korea, where fire blight and black shoot blight coexist.

Stability of hair-tail angling fishing boat according to the induction fishing lamp installation (인덕션 집어등을 설치한 갈치채낚기 어선의 복원성능)

  • Seongjae JEONG;Seongwook PARK;Myongkok JEONG;Geumcheol JEONG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • In this study, the stability of fishing boat inducing the change of fishing lamp in accordance with the installation of induction lamp in comparison with metal halide lamp was investigated. Inclining test for 8.55 ton class of hair-tail angling fishing boat was performed in order to find a GM and light weight. A stability calculation of the target fishing boat on the basis of KST-SHIP program was evaluated. The stability of the fishing boat with a metal halide lamp such as induction lamp according to the result obtained by the inclining test is slightly different, and the stability is not so much affected. Due to the induction lamp installation, the wind area increased by about 3.178 m2. Before installing the induction fishing lamp, G0M was found to be 0.209 at full load departure and 0.296 at departure from fishing ground. After installing the induction lamp, the full load departure condition is 0.178 and the fishing ground departure condition is 0.260. The G0M value before and after installation of the induction fishing lamp shows a difference of about 3% at the full load departure condition. The value of the critical angle of inclination definition showed a difference of about 16%. Despite these differences, it is lower than the regulations; it was confirmed that there will be no significant difference unless it is in an overloaded state.

Development of Multi LED type Door Status Indication Lamp for rolling stock (Multi LED를 이용한 철도차량용 Door Status Indication Lamp)

  • Seo, Bum-Won;Choi, Jae-Sung;Kim, Dong-Il
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1668-1674
    • /
    • 2011
  • Door Inside Lamp of railway rolling stock is installed on interior of the side doors and illuminated at door opening and closing, isolation and fault. So drivers or passengers can notice the door status visually. In the past, a single color or Bi-color LED Lamps have been using and one ~ multiple lamp was used to implement the feature according to client's requirements. (Example: Total of between 2 and 4 lamps are required for the Warning / Emergency operation / Isolation / Fault.) However these design is not easy to apply if there is the mounting space restrictions and the problems such as rising costs can be caused. In addition, it has vulnerability from point of view aesthetic aspects. Therefore the lamp type has been required that has small size and number of colors in order to resolve these problems. Recently multi LED type door status indication lamp have been developed that can meet the requirements and this lamp has been applied in many railway projects. In this study, I'll introduce the general characteristics and mechanical & electrical characteristics of multi LED type door status indication lamp to help development of this kinds of lamp.

  • PDF

Development of Multi LED type Door Status Indication Lamp for rolling stock (Multi LED를 이용한 철도차량용 Door Status Indication Lamp)

  • Seo, Bum-Won;Choi, Jae-Sung;Kim, Dong-Il
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1466-1472
    • /
    • 2011
  • Door Inside Lamp of railway rolling stock is installed on interior of the side doors and illuminated at door opening and closing, isolation and fault. So drivers or passengers can notice the door status visually. In the past, a single color or Bi-color LED Lamps have been using and one ~ multiple lamp was used to implement the feature according to client's requirements. (Example: Total of between 2 and 4 lamps are required for the Warning / Emergency operation / Isolation / Fault.) However these design is not easy to apply if there is the mounting space restrictions and the problems such as rising costs can be caused. In addition, it has vulnerability from point of view aesthetic aspects. Therefore the lamp type has been required that has small size and number of colors in order to resolve these problems. Recently multi LED type door status indication lamp have been developed that can meet the requirements and this lamp has been applied in many railway projects. In this study, I'll introduce the general characteristics and mechanical & electrical characteristics of multi LED type door status indication lamp to help development of this kinds of lamp.

  • PDF