• Title/Summary/Keyword: L.W.O.S.T

Search Result 96, Processing Time 0.028 seconds

Current Transport Characteristics of 22.9 kV High Temperature Superconducting Cable System (22.9 kV 초전도케이블 시스템의 통전특성)

  • Sohn, S.H.;Lim, J.H.;Ryoo, H.S.;Yang, H.S.;Choi, H.O.;Ma, Y.H.;Kim, D.L.;Ryu, K.W.;Sung, T.H.;Hyun, O.B.;Lim, S.W.;Hwang, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.398-399
    • /
    • 2008
  • Enhanced performances of high temperature superconducting (HTS) cable attract tremendous interests of the power utility. However, the reliability issue as the power system is still in controversy. To verify the reliability of HTS cable, 22.9 kV HTS cable system with the specification of 100 m length, 50 MVA capacity, and open refrigeration cooling system was laid on Gochang power testing center of KEPCO in 2006. During the test period, the current transport characteristics, the fundamental function of power cable, have been monitored and investigated precisely. In this paper, the heat loss and AC loss measured at various current load conditions are described and discussed.

  • PDF

Flood control analysis of the sea dike at estuary. (하구방조제의 홍수조절 해석)

  • 서승덕
    • Water for future
    • /
    • v.10 no.2
    • /
    • pp.113-124
    • /
    • 1977
  • Alone the southwesten coast of Korean peninsula, the extensive available arable acreages suited for forming are found in the development of tidal flats in the geographically curved bays with a motable tidal emplitude. It was found that the developments of these tidal flats cover an estimated area more than 276,000ha. In this paper, a flood control system by Pul's Storage Indication Method and Pul's Graphical Method at Return Periods-50 yrs, design rainfall-267mm per 48hrs and design flood-926c.m.s. and at 0.2meter control height above the High Water Ordinary Spring Tide Level (+11.0m) was studied. At the result, the flood demage in the reservoir at Return Periods-50 yrs and the tidal level at H.W.O.S.T.L. were satisfied to the below E.L. 11.20m (Flood Level in the reservoir). Well skilled flood control technique and management and control of draining sluice gate should be required for the disaster prevention from the flood and tide damage.

  • PDF

Prediction of Micro-Bubble Releasing Concentration with the Retention Time of a Micro-Bubble Generating Pump (미세기포 발생펌프 내 체류시간에 따른 미세기포의 발생 농도 예측)

  • Ambrosia, Matthew Stanley;Lee, Chang-Han
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.829-837
    • /
    • 2016
  • The mechanism of micro-bubble generation with a pump is not clarified yet, so the design of water treatment systems with a micro-bubble generating pump is based on trial and error methods. This study tried to explain clearly quantitative relationships of experimental micro-bubble concentration ($C_{air}$) of continuous operation tests with a micro-bubble generating pump and theoretical air solubility. Operation parameters for the tests were discharge pressure ($P_g$), water ($Q_{w0}$) and air ($q_0$) flow rates, orifice diameter ($D_o$), and retention time (t). The experimental micro-bubble concentrations ($C_{air}$) at 4.8 atm of discharge pressure ($P_g$) were in the range of 21.04 to 25.29 mL/L. When the retention time (t) by changing the pipe line length ($L_p$) increased from 1.22 to 6.77s, the experimental micro-bubble concentrations ($C_{air}$) increased from 25.86 to 30.78 mL air/L water linearly. The dissolved and dispersed micro-bubble concentrations ($C_{air}$) are approximately 4 times more than the theoretical air solubility.

Effect of Garlic Oil on Fatty Acid Accumulation and Glycerol-3-Phosphate Dehydrogenase Activity in Differentiating Adipocytes

  • He, M.L.;Yang, W.Z.;You, J.S.;Chaves, A.V.;Mir, P.S.;Benchaar, C.;McAllister, T.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.12
    • /
    • pp.1686-1692
    • /
    • 2009
  • Garlic oil (GAR, Allium sativum L.) has been studied as a feed additive to improve animal production performance and decrease methane emission in ruminants. The present study was designed to determine the possible effect of GAR on fatty acid composition and accumulation in animal fat tissue using a cell model. 3T3-L1 preadipocytes at $2{\times}10^{4}\;mL^{-1}$ were seeded to 24-well plates and allowed to proliferate to reach confluence. The cells were then treated with media containing 0, 2.5, 5, 10, 20 and 40 $\mu{g}$ $mL^{-1}$ of GAR during the differentiation period for 8 days. Media containing dexamethasone, methyl-isobutylxanthine and insulin was applied during the first 2 days of the early differentiation period. On day 8 sub-sets of the wells were stained with oil red-O and the remaining cells were harvested for determination of glycerol-3-phosphate dehydrogenase [EC 1.1.1.8] (GPDH) activity (n = 6) and cellular fatty acid concentration (n = 6). It was found that supplementation of GAR increased (p<0.05) the ratio of monounsaturated fatty acids/saturated fatty acids in the adipocytes and showed inhibitory effect (p<0.05) on the post-confluent proliferation. With relative low dosage, GAR (5-20 $\mu{g}$ $mL^{-1}$) increased (p<0.05) the GPDH activity without affecting the cellular fatty acid concentration, while a high dosage (40 $\mu{g}$ $mL^{-1}$) inhibited (p<0.05) fatty acid accumulation and decreased GPDH activity. Supplementation of GAR had an effect on cell post-confluent proliferation, differentiation and fatty acid accumulation. However, the effect may be diverse and depends on the dose applied.

A study on stress corrosion cracking of weld zone in 304-stainless steel (304 스테인레스鋼 熔接部의 응력부식구열에 관한 硏究)

  • 김경일;강인찬
    • Journal of Welding and Joining
    • /
    • v.5 no.2
    • /
    • pp.35-43
    • /
    • 1987
  • The effect of post weld heat treatment (P.W.H.T) on the propagation rate of stress corrosion cracking(S.C.C) and threshold stress intensity factor ($K_{IC}.c.c$) for stress corrosion cracking of 304 stainless steel has been investigated in boiling 45% $MgCl_2$ solutions with W.O.L specimens. Specimens were precracked by turning a pair of Cr-Mo steel bolts into a machined slot at the end of the specimen. The fracture surface was examined fractographically by Scanning Electron Microscope(S.E.M.)

  • PDF

Electrochemical Generation of Chlorine Dioxide from Sodium Chlorite Using Un-Divided Electrochemical Cell: Effect of Anode Materials (아염소산나트륨의 무격막 전기분해에 의한 이산화염소 생성: 양전극 재질에 따른 영향)

  • Kwon, Tae Ok;Park, Bo Bae;Roh, Hyun Cheul;Moon, Il Shik
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.275-282
    • /
    • 2010
  • A characteristic study of aqueous chlorine dioxide generation from sodium chlorite($NaClO_2$) by an undivided electrochemical cell with different anode materials were performed. $IrO_2$-coated Ti, $RuO_2$-coated Ti and DSA were used as anode materials and Pt-coated Ti electrode was used as cathode. Various electrochemical cell operating parameters such as cell residence time($t_R$), initial feed solution pH, sodium chlorite and sodium chloride(NaCl) concentration and applied current for the generation of chlorine dioxide in an un-divided cell were investigated and optimized. Estimated optimal cell residence times in $IrO_2$-coated Ti, $RuO_2$-coated Ti and DSA anode material systems were around 2.27, 1.52 and 1.52 sec, respectively. Observed optimum initial feed solution pH was around 2.3 in all anode material systems. Optimum sodium chlorite concentrations in $IrO_2$-coated Ti, $RuO_2$-coated Ti and DSA anode systems were around 0.43, 0.43 and 0.32 g/L, respectively. Optimum electrolyte concentration and applied current were around 5.85 g/L and 0.6 A in all anode systems. Current efficiencies of $IrO_2$-coated Ti, $RuO_2$-coated Ti and DSA anode systems under optimum conditions were 79.80, 114.70 and 70.99%, respectively. Obtained energy consumptions for the optimum generation of chlorine dioxide were 1.38, 1.03 and $1.61W{\cdot}hr/g-ClO_2$, respectively.

EFFICACY EVALUATION OF THE WHITENING COSMETICS USING IN VITRO TYROSINASE INHIBITION ASSAY

  • Lee, J. P.;Kim, Y. O.;J. Y. Jang;K. H. Son;S. J. Yang;Lee, K. S.;Kim, W. H.;J. T. Hong;Park, S. S.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.479-479
    • /
    • 2003
  • We investigated the tyrosinase inhibitory effect using whitening materials such as arbutin, ethyl ascorbyl ether, glabridin, kojic acid, magnesium ascorbyl phosphate and ascorbic acid. Tyrosinase inhibition rate were determined varying the enzyme concentration, reaction time, reaction temperature and pH. The optimal conditions to measure the inhibitory efficacy were as follows. : enzyme concentration 1,500 or 2,000IU/mL, reaction time 15min(for the enzyme concentration 1,500 IU/mL) and l0min(for the enzyme concentration 2,000IU/mL), reation temperature 42$^{\circ}C$, pH 6.5. Under these conditions $IC_{50}$/ of arbutin, ethyl ascorbyl ether, glabridin, kojic acid, magnesium ascorbyl phosphate and ascorbic acid were calculated. In the case of magnesium ascorbyl phosphate, the inhibitory effect of tyrosinase was very low and the $IC_{50}$/ of magnesium ascorbyl phosphate could not be calculated. Other five materials showed good inhibitory effect of tyrosinase and can be used for the whitening materials.

  • PDF

The Numerical Modeling on the I-t Characteristic of the Fuse Element (휴즈 엘리먼트의 용단특성에 대한 수치해석적 모델링)

  • Jeong, K.H.;Lee, S.H.;Park, D.K.;Kim, Y.L.;Lee, J.C.;Koo, K.W.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1187-1189
    • /
    • 1995
  • The paper is concerned with the pre-arcing behavior of rapid current limiting fuselink using copper as a melting element. The phenomenon is faced by a numerical simulation(especially, FDM is applicated) of the melting element. Through the results, we can know the trends of the I-t characteristics and temperature distribution along the x axis for different fuselink shapes with circular, rectangular, and skew restriction type respectively, to be good for designing the optimal element.

  • PDF

A Development of the High Performance IGBT type Auxiliary Power Supply for Railways. (전동차용 고성능 IGBT형 보조전원장치 개발)

  • 김태완;서광덕
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.500-506
    • /
    • 1999
  • This paper presents the h밍h performance [GBT type auxiliary jXlWer supply designt.'Cl by new concept. For t the simplification and higher performance, the direct :3 level PWlVl inverter using the high capacity IGBT and t the 32bit DSP are adopted. The cost as well as bulk and weight is appreciably reduced about 40% lower than t those of conventional one. the electrical efficiency above 94~) o and the audible noise level is less than 65dB. In a addition, the TIID(Total lIannonic Distortion) factor is below 5% an이 the voltage fluctuation on a transient s state is below 10%.w 10%.

  • PDF

Photodegradation of Halogen Derivatives of Aliphatic Hydrocarbon in Aqueous Photocatalytic Suspensions (지방족 탄화수소의 할로겐 유도체 수용액의 광촉매-광분해)

  • Jun, Jin;Jung, Hak-Jin;Kim, Hae-Jin;Kim, Sam-Hyeok
    • Journal of Environmental Science International
    • /
    • v.6 no.1
    • /
    • pp.75-88
    • /
    • 1997
  • The rates of photodegradation, reactivities, and mechanisms of photooxidation for the aqueous solution containing with halogen derivatives of aliphatic hydrocarbons have been discussed with respect to the kinds of photocatalysts, concentration of photocatalytlc suspensions, strength of radiant power, time of illumination, changes of pH of substrate solution, wavelength of radiation, and pressure of oxygen gas saturated In the solution. These aqueous solutions suspended with 0.5 $gL^{-1}$ $TiO_2$ powder have been photodecomposed in the range of 100 and 93.8% per 1 hour if it is illuminated with wavelength (λ $\geq$ 300nm) produced from Xe-lamp(450W). The photocatalytic abilities have been increased In the order of $Fe_2O_3$ < CdS < $CeO_2$ < Y_2O_3$ <$TiO_2$, and rates of photodegradation for the solution have maldmum values in the condition of pH 6 ~ 8 and 3 psi-$O_2$ gL^{-1}$. These rates for the Photoolddation Per 1 hour were dependent on the size of molecular weight and chemical bonding for organic halogen compounds and the rates of photodegadation were increased in the order of $C_2H_5Br$ < CH_2Br_2$ < C_5H_11Cl C_2H_4Cl_2$ < tracts-$C_2H_2Cl_2$ < cis-C_2H_2Cl_2$ The T_{1/2}$ and t99% for these solutions were 5~21 and 40~90 minutes. respectively, and these values were coincided with Initial reaction kinetics(ro). It was found that reaction of photodegradation has the pseudo first-order kinetics controlled by the amount of $h^+_{VB}$ diffused from a surface of photocatalysts.

  • PDF