• Title/Summary/Keyword: L-C filter combination

Search Result 16, Processing Time 0.019 seconds

LC Filter Design Considering Voltage Control Performance and PWM Inverter Size for Dynamic Voltage Restorers (동적전압보상기(DVR)의 전압제어특성과 인버터 용량을 고려한 출력필터 설계방법)

  • Kim Hyosung;Kim Jang-Hwan;Sul Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.117-123
    • /
    • 2005
  • The cutoff frequency of a LC output filter for Dynamic Voltage Restorers (DVR) limits the control bandwidth of a DVR system while it attenuates the inverter switching ripples. For a selected cutoff frequency of a LC output filter, infinite number of L-C combinations is possible. Although different L-C combination has different filter characteristics, the filter design on L-C combination has been depended on field experiences without clear analysis. This paper proposes a design criterion and design examples for the L-C filter combination considering the control characteristics and the size of DVRs. An experimental DVR system based on the proposed LC output filter design methodology is built and tested.

LC Filter Design for Direct Voltage Restorers Considering Voltage Control Performance and PWM Inverter Size (PWM 인버터의 전압제어특성과 인버터 용량을 고려한 순시전압보상기(DVR)의 출력필터 설계방법)

  • Kim, Hyo-Sung;Kim, Jang-Hwan;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.118-121
    • /
    • 2004
  • The cutoff frequency of a LC output filter for Dynamic Voltage Restorers (DVR) limits the control bandwidth of a DVR system and the attenuation factor against the inverter switching ripples. For a selected cutoff frequency of a LC output filter, infinite number of L-C combinations is possible. Although different L-C combination has different filter characteristics, the filter design on L-C combination has been depended on field experiences without clear analysis. This paper proposes a design criterion and design examples for the L-C filter combination considering the control characteristics and the size of DVRs. An experimental DVR system based on the proposed LC output filter design methodology is built and tested.

  • PDF

A Study on the Diatomaceous Earth Filtration of Settling Basin Effluent (정수장 침전지 유출수의 규조토 여과에 관한 연구)

  • Shin Dae-Yewn;Ji Sung-Nam;Moon Ok-Ran;Kim Ji-Yeong;Suh Dong-Woo;Cho Young-Kwan
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.410-416
    • /
    • 2004
  • The objective of this investigation was to evaluate applicability of precoat filtration that can be substituted for rapid sand filter of conventional water treatment system(CWTS). Precoat filter used in this experiment are candle filter. Element disk of candle are pore size $10{\mu}m(R),\;20{\mu}m(B)$ And diatomaceous earth are cake pore size $3.5{\mu}m$(Standard Super- Cel; A), $7{\mu}m$(Hyflo Super-Cel; B) and $17{\mu}m$(Celite 545RV; C). $2kg/m^2$ diatomaceous earth is used for precoating, it coated candle in $5{\sim}6mm$ thickness. 1. Al adsorption dosages by diatomaceous earth used in experimental we Hyflo Super-Cel 0.843mg/g, Standard Super-Cel 0.782 mg/g and Celite 545RV 0.766 mg/g. 2. Filtrate of precoat filter during 60min are R-C combination 20.7($m^3/m^2$)>B-C 18.3($m^3/m^2$)>B-B 15.0($m^3/m^2$)> R-B 12.9($m^3/m^2$)> R-A 11,093($l/m^2$). 3. Water quality of precoat filter effluent are thus. $KMnO_4$ consumption are $1.10{\sim}2.20mg/l$, removal rate are $30.9{\sim}65.6\%$. They are R-A 1.10(mg/l)(removal rate $65.6\%$). R-C(2.20 mg/l)(removal rate $30.9\%$). 4. $Al^{3+}$ are not detected with all combination, removal rate $100\%$. 5. Considering water quality and flux, continued running time of R-A combination is 7 hr. Accumulated filtrate are $74.4 m^3/m^2$, average flux is $177.2 l/m^2{\cdot}min$. And filtrate per diatomaceous earth 1g are 37.2 l. 6. R-A effluent's water quality are $KMnO_4$ Consumption 1.10(mg/l), DOC 1.161 mg/1, Al 0.0 mg/1, $UV_{254}$ 0.016/cm, Turbidity 0.1(NTU). R-A combination is suitable to precoat filtration for the settling basin effluent treatment.

A Novel Filter Design for Output LC Filters of PWM Inverters

  • Kim, Hyo-Sung;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.74-81
    • /
    • 2011
  • The cutoff frequency of the output LC filters of PWM inverters limits the control bandwidth of the converter system while it attenuates voltage ripples that are caused by inverter switching activities. For a selected cutoff frequency of an output LC filter, an infinite number of L-C combinations is possible. This paper analyses the characteristics of output LC filters for PWM inverters terms of the L-C combinations. Practical circuit conditions such as no-loads, full resistive-loads, and inductive-load conditions are considered in the analysis. This paper proposes a LC filter design method for PWM inverters considering both the voltage ynamics and he inverter stack size. An experimental PWM inverter system based on the proposed output LC lter design uideline is built and tested.

Design and Fabrication of a Surge Protective Device for Electrical Mains on Shipboard (전원회로용 서지방호장치의 설계 및 제작)

  • Moon, Seung-Bo;Park, Dae-Won;Song, Jae-Yong;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1035-1040
    • /
    • 2005
  • This paper deals with the design rule and performance results of the surge protective devices (SPDs) for low-voltage mains on shipboard. The proposed SPDs consists of a metal oxide varistors (MOV) and a L-C filter to improve noise-elimination performance. Three kinds of SPDs are fabricated and tested by using a combination surge generator which produce the standard impulse current of 8/20${\mu}s$ 2.1kA. As a results, the proposed SPDs with series L-C filter have more excellent transient blocking and noise reduction performance than the conventional ones.

  • PDF

Design and Fabrication of a Transient Voltage Stocking Device for Electrical Mains (전원회로용 과도전압 차단장치의 설계 및 제작)

  • 이종혁;송재용;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.486-489
    • /
    • 1999
  • This paper deals with the design rule and performance results of the transient voltage blocking devices (TBD) for low-voltage mains on shipboard. The proposed TBD consists of metal oxide varistors (MOV) and L-C filter to improve noise-elimination performance. Three kinds of TBDs are fabricated and tested by using a combination surge generator which can produce the standard impulse current of 8/20${\mu}$s 2.1kA. As a reults, the proposed TBD with series L-C filter has more excellent transient blocking and noise reduction performance than the conventional TBDs.

  • PDF

Preparation of Minimally Processed Mulberry (Morus spp.) Juices (최소가공기술을 이용한 오디 과실주스의 제조)

  • Kim, In-Sook;Lee, Jun-Young;Rhee, Soon-Jae;Youn, Kwang-Sup;Choi, Sang-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.321-328
    • /
    • 2004
  • Raw mulberry (Morus spp.) juice was prepared by minimal processing using several filter aids, fining agents, and clarifying enzymes, followed by filtration, centrifugation, and membrane filtration. Control of browning in minimally processed mulberry juices by anti-browning agents, sodium hydrosulfite, L-ascorbic acid, citric acid, and NaCl, was investigated using quantitative measurements of color changes during storage. Clarification of mulberry juice was improved by adding several filter aids, fining agents, and enzymes, followed by filtration and centrifugation. Several fining agents, including chitosan, chitin, PVPP, gelatin, and casein at a concentration of 1%, and combination of ultrafiltration and centrifugation at 8,000 rpm were not suitable for clarification of juice owing to strong adsorption of anthocyanin pigment. Combination of $0.01\;{\mu}m$ membrane filtration and centrifugation at 8,000 rpm was effective for clarification of mulberry juice. Browning of minimally processed mulberry juice was inhibited significantly by adding 200 ppm sodium hydrosulfite, and 0.1% L-ascorbic acid (L-AsA) and 0,1% citric acid (CA) also showed considerable browning inhibition. Combination of L-AsA and CA, which was moderately effective for browning inhibition of juice, may be useful as a sulfite alternative for mulberry juice. Optimum sugar ($^{\circ}Brix$)/acid ratio and commercial sterilization of minimally processed mulberry juice were approximately 40 and 10 min at $85-90^{\circ}C$, respectively.

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Combination of Hydrophobic Filtration and Enrichment Methods for Detecting Bacillus cereus in Fresh-Cut Cabbage

  • Lee, Sujung;Choi, Yukyung;Lee, Heeyoung;Kim, Sejeong;Lee, Jeeyeon;Ha, Jimyeong;Oh, Hyemin;Lee, Yewon;Kim, Yujin;Yoon, Yohan;Lee, Soomin
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.5
    • /
    • pp.325-329
    • /
    • 2018
  • This study developed a rapid detection method for Bacillus cereus in fresh-cut cabbages. Fresh-cut cabbage samples were inoculated at 1-, 2- and 3-Log CFU/g, and pathogens were enriched in tryptic soy broth containing 0.15% polymyxin B at $30^{\circ}C$, $37^{\circ}C$, and $42^{\circ}C$ to determine the detection limit and appropriate enrichment temperature for multiplex PCR detection. Enriched bacterial cells in enrichment broth were collected in a hydrophobic filter prior to DNA extraction for multiplex PCR. Filters were resuspended in distilled water, and DNA was extracted from the suspension. DNA samples were further analyzed by multiplex PCR. Detection limit of multiplex PCR was 5-Log CFU/mL. B. cereus cell counts were higher (P < 0.05) at $42^{\circ}C$ than other temperatures. Detection rate of 1-, 2-, and 3-Log CFU/g inoculated samples were 60%, 80%, and 100% after enrichment respectively. However, when enriched samples were filtered with hydrophobic membrane filter, detection rates became 100%, regardless of inoculation level. Results indicate a combination of enrichment with hydrophobic filtration improves rapid detection efficiency of B. cereus in fresh-cut cabbage by multiplex PCR.

Reducing Methods of Patient's Exposed Dose Using Auto Exposure Control System in Digital Radiography (디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안)

  • Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • This study was carried out to reduce patient dose through focus-detector distance, kilovoltage, and a combination of copper filters. In the C, L-spine lateral, Skull AP views were obtained by making changes of 60-100 kV in tube voltage and of 100-200 cm in focus-detector distance and by adding a copper filter when using an auto exposure control device in the digital radiography equipment. The incident dose showed 90 kV, 0.3 mmCu in C-spine lateral with 0.06 mGy under the condition of 200 cm; 100 kV, 0.3 mmCu with 0.40 mGy under the condition of 200 cm and 90 kV 0.3 mmCu in Skull AP with the lowest value of 0.24 mGy under the condition of 140 cm. It was observed that entrance surface dose decreased the most when was increased by 150 cm, 70 kV (C-spine lateral), 81 kV (L-spine lateral). It was also found out that as the between the focus-detector increased in the expansion of the video decreased but the difference was not significant when the distance was 180 cm or more. Skull AP showed the most reduction in the entrance surface dose when the tube voltage was changed by 80 kV, 0.1 mmCu, and 120 cm. Therefore, when using the automatic exposure control device, it is recommended to use the highest tube voltage if possible and to increase focus-detector distance at least by 150~200 cm in wall and 120~140 cm in table in consideration of the radiotechnologist's physical conditions, and to combine 0.1~0.3 mmCu and higher filters. It is thus expected to reduce patient dose by avoiding distortion of images and reducing the entrance surface dose.