• Title/Summary/Keyword: L지수

Search Result 1,452, Processing Time 0.027 seconds

Application of Bivariate Spatial Association for the Quantitative Marine Environment Pattern Analysis (정량적인 해양환경패턴 분석을 위한 이변량 공간연관성 적용)

  • Hwang, Hyo-Jung;Choi, Hyun-Woo;Kim, Tea-Rim
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.1
    • /
    • pp.155-166
    • /
    • 2008
  • The quantitative bivariate spatial pattern analysis was applied for the water quality and nutrients data of Masan Bay, and for this analysis Pearson's r as aspatial correlation measurement, Moran's I as spatial association measurement and L index as integration of aspatial and spatial measurement methods were used. To understand the aspatial and spatial characteristics implicated in L index, Pearson's r as well as Moran's I were classified into 3 types respectively, and Pearson's r and Moran's I were combined with 9 types, and also quantile of L index value was used for each of those 9 types. Finally, these types were defined as 5 groups having not overlapped L index range. According to the application result of L index groups, bivariate water quality and nutrients showed no aspatial correlation regardless of spatial association in February and July, but they showed aspatial correlation having clustered spatial pattern in May and November. The result of this study providing the guideline for the interpretation of aspatial correlation and spatial association using L index is expected to be helpful for the marine environment pattern analysis using quantitative index for further study.

  • PDF

The Changes in the Quality of Life Measure of the Seoul Metropolitan Area (수도권 삶의 질 지수 변동에 관한 연구)

  • Lee, Se-Hyung;Chang, Hoon;Rho, Jin-A
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.1
    • /
    • pp.29-37
    • /
    • 2011
  • The purpose of this research is to measure Quality of Life indices using Factor Analysis and Principle Component Analysis and to analyze the spatial patterns of Quality of life distribution in the Seoul Metropolitan Area in terms of spatial association using spatial statistics and spatial exploratory technique. In order to check the degree of clustering, this study used spatial autocorrelation indices, global Moran's I index. In addition, local scale analysis was conducted using Moran Scatterplot and Local Moran's I to identify the spatial association pattern and the high Quality of life. The analysis based on global statics showed that, in the Seoul Metropolitan Area, QoL Indices had been distributed with positive spatial association. According to the local spatial statistics, the general tendency of clustering H-H clusters which were mainly concentrated on the Seoul, L-H clusters were concentrated on the Kyunggi-Do and L-L Clusters showed the regional extent of lagging behind. However, in case of H-H, L-H Clusters they had been spread out in the Newtown as population increase.

Comparison of Left Ventricular Volume and Function between 46 Channel Multi-detector Computed Tomography (MDCT) and Echocardiography (16 채널 Multi-detector 컴퓨터 단층촬영과 심초음파를 이용한 좌심실 용적과 기능의 비교)

  • Park, Chan-Beom;Cho, Min-Seob;Moon, Mi-Hyoung;Cho, Eun-Ju;Lee, Bae-Young;Kim, Chi-Kyung;Jin, Ung
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.45-51
    • /
    • 2007
  • Background: Although echocardiography is usually used for quantitative assessment of left ventricular function, the recently developed 16-slice multidetector computed tomography (MDCT) is not only capable of evaluating the coronary arteries but also left ventricular function. Therefore, the objective of our study was to compare the values of left ventricular function quantified by MDCT to those by echocardiography for evaluation of its regards to clinical applications. Material and Method: From 49 patients who underwent MDCT in our hospital from November 1, 2003 to January 31, 2005, we enrolled 20 patients who underwent echocardiography during the same period for this study. Left ventricular end-diastolic volume index (LVEDVI), left ventricular end-systolic volume index (LVESVI), stroke volume index (SVI), left ventricular mass index (LVMI), and ejection fraction (EF) were analyzed. Result: Average LVEDVI ($80.86{\pm}34.69mL$ for MDCT vs $60.23{\pm}29.06mL$ for Echocardiography, p<0.01), average LVESVI ($37.96{\pm}24.52mL$ for MDCT vs $25.68{\pm}16.57mL$ for Echocardiography, p<0.01), average SVI ($42.90{\pm}15.86mL$ for MDCT vs $34.54{\pm}17.94mL$ for Echocardiography, p<0.01), average LVMI ($72.14{\pm}25.35mL$ for MDCT vs $130.35{\pm}53.10mL$ for Echocardiography, p<0.01), and average EF ($55.63{\pm}12.91mL$ for MOCT vs $59.95{\pm}12.75ml$ for Echocardiography, p<0.05) showed significant difference between both groups. Average LVEDVI, average LVESVI, and average SVI were higher in MDCT, and average LVMI and average EF were higher in echocardiogram. Comparing correlation for each parameters between both groups, LVEDVI $(r^2=0.74,\;p<0.0001)$, LVESVI $(r^2=0.69,\;p<0.0001)$ and SVI $(r^2=0.55,\;p<0.0001)$ showed high relevance, LVMI $(r^2=0.84,\;p<0.0001)$ showed very high relevance, and $EF (r^2=0.45,\;p=0.0002)$ showed relatively high relevance. Conclusion: Quantitative assessment of left ventricular volume and function using 16-slice MDCT showed high relevance compared with echocardiography, therefore may be a feasible assessment method. However, because the average of each parameters showed significant difference, the absolute values between both studies may not be appropriate for clinical applications. Furthermore, considering the future development of MDCT, we expect to be able to easily evaluate the assessment of coronary artery stenosis along with left ventricular function in coronary artery disease patients.

Los Angeles Abrasion Test for Estimating Engineering Index on the Sedimentary Rocks of Kyeongsang Basin (퇴적암의 공학지수를 추정하기 위한 L. A. 마모율 시험)

  • Min, Tuk-Ki;Moon, Jong-Kyu;Lee, Sang-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.11
    • /
    • pp.15-26
    • /
    • 2007
  • Los Angeles abrasion loss test has usally been applied to the quarry for the purpose of aggregate hardness estimation. 324 blocks from 25 sites of Kyeongsang basin samples of sedimentary rock were examined and tested in laboratary. This paper found that L. A. abrasion loss test is a good method to estimate engineering index such as uniaxial compressive strength, elastic modulus, indirect tensile strength, point load strength index, Schmidt hammer rebound value of sedimentary rocks with high correlation factor. Engineers will prefer L. A. abrasion loss test to the other one for design and construction as this method is quick and easy.

The Characteristic of Swelling Index Evaluated by CRS Consolidation Test (일정변형속도(CRS) 압밀시험에 의한 팽창지수 산정 특성)

  • 한상재;김수삼;김병일;이응준
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.311-317
    • /
    • 2003
  • The swelling index of clayey soil was examined by constant rate of strain(CRS) consolidation test. Four kinds of strain rate were applied during unloading. The strain rates are l/l, l/5, 1/10, l/l 5 of loading. The strain rates during loading are 0.05%/min and 0.03%/min. From the test results using standard consolidometer, the swelling indexes were much similar values in case of 1/5 or 1/10 of the strain rate during loading stage. In the relation between effective stress and excess pore water pressure ratio, it was found that the existence of cross point and the stress level can be separated into two zones according to the swelling index.

The Point Load Index of the Daegu Shale and its Relation to the Uniaxial Compressive Strength (대구지역 셰일의 점재하지수 특성 및 일축압축강도와의 상관성)

  • Lee, Younghuy;Youn, Chanho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.3
    • /
    • pp.37-45
    • /
    • 2009
  • The experimental study was carried out to evaluate the characteristics of the point load index and the uniaxial compressive strength of inherently anisotropic shale in the laboratory. In the testing program the effects of size and the shape on the point load index were investigated both in the axial and diametral direction. In general, the point load index of the shale was constant when the length/diameter (L/D) ratio of the specimen is greater than 1.0 in the diametral direction. The point load index in axial direction shows slight decrease as the L/D ratio is increased and the corner breakage was observed when L/D ratio is greater than unity. The minimum point load index was observed in the bedding angle of $\beta=15^{\circ}{\sim}30^{\circ}$ in the axial point load tests and of $\beta=30^{\circ}$ in the uniaxial compression tests. The relationship between the point load index and the uniaxial compressive strength was linear to ${\sigma}_c=25.0 I_{s(50)}$ for the specimen with the bedding plane angle, $\beta$ at the range of $0^{\circ}{\sim}90^{\circ}$. On the other hand, this relationship was appeared linear to ${\sigma}_c=14.4 I_{s(50)}$ when the bedding angle, $\beta$ is fixed to 90${^{\circ}}$ and this correlation is much different from ${\sigma}c=22 I_{s(50)}, which is generally applied to the rock specimen with no bedding plane in ISRM (1985). The anisotropic strength with different $\beta$ angle shows the shoulder type and this can be suitably modelled by the corrected Ramamurthy'(1993)s equation with the index value of 'n' equal to 3.0.

  • PDF

Harmonization of Hemolysis Index in Clinical Chemistry Laboratory and Its Application as a Result Verification Tool (화학검사 결과의 검증을 위한 용혈 지수 일치화 도구 개발)

  • Pyo, Sang Shin;Nam, Hyun Su;Cha, Young Jong;Lee, Seungkwan;Lee, Hae Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.350-358
    • /
    • 2017
  • The hemolysis index (HI) is semi-quantitative marker for hemolysis. Because the characteristics of the HI vary from one commercial platform to another, no standardization or harmonization of the HI is currently available. Specimens (N=40) randomly selected from clinical patients were artificially hemolyzed in vitro. The serum of the specimens was then diluted with a 20 mg/dL difference between 0~300 mg/dL based on serum hemoglobin measured using the XE-2100 hematology automation equipment (Sysmex, Japan). Diluted serum was measured using the Hitachi-7600 biochemical automation equipment (Hitachi, Japan) to differentiate between HI and serum hemoglobin. The data showed linearity between HI and serum hemoglobin and that HI 1 contained approximately 20 mg/dL of serum hemoglobin. To determine the blood rejection threshold, the HI was divided into three groups: HI 0~1, HI 4~6, HI 9~15. After another batch of clinical specimens (N=40) was measured using a Hitachi-7600 (Hitachi, Japan), each specimen was moved forward and backward with the piston of the syringe to induce an artificial in vitro hemolysis, then measured again with a Hitachi-7600 (Hitachi, Japan). The percentage difference between the three groups was analyzed by ANOVA or the Kruskal-Wallis test. In the post-test, there were significant differences between the HI 0~1 and the HI 5~6: Glucose, creatinine, total protein, AST, direct bilirubin, uric acid, phosphorus, triglyceride, LDH, CPK, Magnesium, and potassium levels. Because many clinical tests differed significantly, the threshold for hemolysis could be appropriate for HI 5 (serum hemoglobin 100 mg/dL).

Estimation of Site Index Curves for Loblolly Pine(Pinus taeda L.) and Slash Pine(Pinus elliottii Engelm.) Plantations (테에다소나무림(林)과 엘리오티소나무림(林)의 조림지(造林地)에 대한 지위지수(地位指數) 곡선(曲線) 추정(推定)에 관(關)한 연구(硏究))

  • Lee, Young-Jin;Hong, Sung-Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.88 no.3
    • /
    • pp.285-291
    • /
    • 1999
  • Loblolly(Pinus taeda L.) and slash(Pinus elliottii Engelm.) pines are the most important timber producing species in the Southern United States. Site index equations to estimate site index curves(base age 25 years) for loblolly pine and slash pine plantations have been developed based on long-term repeated measurement data sets. To check magnitude of errors in estimating site index, each cumulative measurement cycle data sets and all combined data sets were used to recalculate site index values. The Chapman-Richards' growth function was selected for stand height prediction. Anamorphic base age invariant site index curves were presented based on this height prediction equation. Statistics used in the evaluation were mean of the differences and mean of the absolute differences. For plantation ages less than 5 years, site index values showed very sensitive fur both species based on the evaluation test.

  • PDF

Effects of Moisture Content and CO2 Gas Injection on Physicochemical Properties of Extruded Soy Protein Isolate (수분함량과 CO2 가스 주입에 따른 분리대두단백 압출성형물의 이화학적 특성)

  • Kim, Na Yeong;Ryu, Gi Hyung
    • Food Engineering Progress
    • /
    • v.21 no.2
    • /
    • pp.150-157
    • /
    • 2017
  • The objective of this study was to determine the effect of moisture contents (40, 50, 60%) and $CO_2$ gas injection (0 and 800 mL/min) on physicochemical properties of extruded soy protein isolate (SPI). The expansion ratio and the specific length increased, but piece density decreased with the increase in $CO_2$ gas injection from 0 to 800 mL/min at both 40 and 50% moisture contents. On the contrary, the expansion ratio and the specific length decreased, but piece density increased with the increase in $CO_2$ gas injection from 0 to 800 mL/min at 60% moisture content. Extruded SPI with $CO_2$ gas injection at 800 mL/min had small cell size and higher amount of cell than extruded SPI without $CO_2$ gas injection. The water holding capacity and nitrogen solubility index increased, and the integrity index and the texture decreased with the increase in $CO_2$ gas injection from 0 to 800 mL/min. In conclusion, extruded SPI with the $CO_2$ gas injection at 800 mL/min showed better expansion properties and cell formation than extruded SPI without the $CO_2$ gas injection.

Efficient RSA Multisignature Scheme (효율적인 RSA 다중 서명 방식)

  • 박상준;박상우;원동호
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.7 no.2
    • /
    • pp.19-26
    • /
    • 1997
  • In this paper, we propose an RSA multisignature scheme with no bit expansion in which the signing order is not restricted. In this scheme we use RSA moduli with the same bit length. the most 1 bits of which are same. The proposed scheme is based on these RSA moduli and a repeated exponentiation of Levine and Brawley. Kiesler and Harn first utilize the repeated exponentiation technique in their multisignature scheme, which requires 1.5m exponentiations for signing, where m is the number of signers. However, the proposed scheme requires (equation omitted) m exponentiation. So if l is sufficiently large (l $\geq$ 32), then we can neglect the vaue (equation omitted