• 제목/요약/키워드: L/L vacuum system

검색결과 132건 처리시간 0.033초

적외선 우주망원경 냉각시스템 열설계 및 열침입량 측정 (Thermal Design and Heat Load Measurement of PSICS)

  • 양형석;김동락;이병섭;최연석
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.43-46
    • /
    • 2005
  • A Protomodel Space Infrared Cryogenic System (PSICS) cooled by a stirling cryocooler was designed. The PSICS has an IR sensor inside a cold box which is cooled by a stilting cryocooler with refrigeration capacity of 500mw at 80K in a vacuum vessel. It is important to minimize heat load for reducing background thermal noise. In order to design the cryogenic system of low heat load and to reduce heat load, we did several numerical analyses and tested using boil-off calorimetry with liquid nitrogen to measure the heat leak of the system. In this paper, we present the results obtained by thermal analysis and heat load measurement for designing the PSICS.

수소 분위기 중 열처리법을 이용한 고자기이방성 L10 FePt 박막 제작 (Preparation of tetragonal phase L10 FePt thin films with H2 annealing atmosphere)

  • 공석현;김경환
    • 한국진공학회지
    • /
    • 제16권5호
    • /
    • pp.343-347
    • /
    • 2007
  • Glass disk상에 대향 타겟식 스퍼터링(Facing Target Sputtering) 방식을 이용하여 $0.1\;{\AA}/s$의 낮은 증착속도로 증착시킬 경우 b.c.c. (100)면 우선배향성을 확인하였으며, 그 위에 Pt박막을 증착시킨 경우 hetero-epitaxial 성장에 의해 Pt박막이(111)의 조밀면이 아닌 (100)면이 우선배향 되었다. 이렇게 형성된 Fe (100)/Pt (100) 이층막(두께 각 3 nm)을 $600\;^{\circ}C$ 수소분위기에서 열처리함에 의해 막전체에 걸쳐서 f.c.t. (00n)면을 형성시키는 데 성공하고, 또한 Fe (100)면 상에 Pt 박막을 증착시키는 동안 열처리를 하고 증착 이후 수소분위기에서 열처리함에 의해 열처리 시간 및 온도를 크게 낮출 수 있음을 확인하였다.

STM 탐침과 니트로벤젠 분자 사이의 거리변화에 따른 전기전도 특성 연구 (The Study on property of electrical conduction through variable tip-distance Using STM)

  • 이남석;최원석;장정수;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1390-1391
    • /
    • 2006
  • 본 연구에서는 전도성 분자로 잘 알려진 4,4-Di(ethynyl phenyl) -2'-nitro-1-(thioacetyl)-benzene(nitro - benzene) 분자를 Au (111) 표면에 자기조립하고, ultra high vacuum scanning tunneling microscopy (UHV-STM)을 사용하여 STM tip과 sample 사이의 거리를 변화시키면서 전기전도 특성을 측정하였다. Au 기판제작은 연증착시스템 (Thermal Evaporation System)으로 제작하였으며, piranha 용액 ($H_{2}SO_{4}\;:\;H_{2}O_{2}$=3:1)을 사용하여 전치리한 후, 자기조립 단분자막 (SAMs)을 형성하였다. 먼저 1-octanethiol을 ethanol solution용액 1 mM/L 농도에서 24시간 동안 자기조립한 후에, ethanol를 solution 용액으로 이용하여 nitro-benzene를 0.1 nM/L 농도로 암실에서 30분간 자기조립 하였다. 자기조림 후 solution을 제거하기 위해 에탄올로 세척하여 $N_2$로 건조시켰다. 이 조건하에서 UHV-STM을 사용하여 nitro-benzene SAMs의 실시간 모폴로지의 변화에 따른 nitro-benzene의 전기전도 특성을 STM tip - SAMs - Au 기판의 수직구조로 STM tip과 nitro-benzene의 거리를 변화시키면서, tunneling current을 조사하였다. 측정 결과 Z-position 변화에 대한 tunneling current와 resistance의 변화를 확인할 수 있었다.

  • PDF

IMO Type C LNG 저장 탱크의 단열성능 및 구조적 건전성 평가 (Evaluation of Insulation Performance and Structural Integrity of an IMO Type C LNG Storage Tank)

  • 박희우;박진성;조종래
    • 한국기계가공학회지
    • /
    • 제20권7호
    • /
    • pp.1-7
    • /
    • 2021
  • Restrictions on the emissions of nitrogen oxides, sulfur oxides, carbon dioxide, and particulate matter from marine engines are being tightened. Each of these emissions requires different reduction technologies, which are costly and require many pieces of equipment to meet the requirements. Liquefied natural gas (LNG) fuel has a great advantage in reducing harmful emissions emitted from ships. Therefore, the marine engine application of LNG fuel is significantly increasing in new ship buildings. Accordingly, this study analyzed the internal support structure, insulation type, and fuel supply piping system of a 35 m3 International Maritime Organization C type pressurized storage tank of an LNG-fueled ship. Analysis of the heat transfer characteristics revealed that A304L stainless steel has a lower heat flux than A553 nickel steel, but the effect is not significant. The heat flux of pearlite insulation is much lower than that of vacuum insulation. Moreover, the analysis results of the constraint method of the support ring showed no significant difference. A553 steel containing 9% nickel has a higher strength and lower coefficient of thermal expansion than A304L, making it a suitable material for cryogenic containers.

Measurement of the ICRH antenna phasing using antenna strap probe based diagnostic system in EAST tokamak

  • Liu, L.N.;Liang, Q.C.;Yang, H.;Zhang, X.J.;Yuan, S.;Mao, Y.Z.;Zhang, W.;Zhu, G.H.;Wang, L.;Qin, C.M.;Zhao, Y.P.;Cheng, Y.;Zhang, K.
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3614-3619
    • /
    • 2022
  • To operate the ion cyclotron resonance heating (ICRH) antennas in a better heating state and produce relatively low impurities, it is necessary to control the antenna spectrum by changing the antenna phasing. As the electrical length of the antenna feeding transmission lines is changing as a matter of the standing wave pattern at the ceramic supports, 90° elbows, T-connectors and antenna loops, we chose to measure the current at the grounding points of the antenna loops by antenna strap probe. The voltage drops along a small, several millimeter-long paths at the end of the antenna loops give a signal that is proportional to the current in the antenna loop. Through the simulation of the antenna strap probe and the actual measurement of the antenna phasing under vacuum conditions, the reliability of the antenna strap probe based diagnostic system have been successfully proved. Moreover, this system was successfully applied to the ICRH daily experiments in the spring of 2021. In the near future, the active real-time feedback control of the antenna phasing system will be developed based on this diagnostic system in the EAST tokamak.

소형 수소액화기 설계 및 운전에 관한 연구 (Design and Operation of a Small-Scale Hydrogen Liquefier)

  • 백종훈;강상우;강형묵;나다니엘 갈소;김서영;오인환
    • 한국수소및신에너지학회논문집
    • /
    • 제26권2호
    • /
    • pp.105-113
    • /
    • 2015
  • In order to accelerate hydrogen society in current big renewable energy trend, it is very important that hydrogen can be transported and stored as a fuel in efficient and economical fashion. In this perspective, liquid hydrogen can be considered as one of the most prospective storage methods that can bring early arrival of the hydrogen society by its high gravimetric energy density. In this study, a small-scale hydrogen liquefier has been designed and developed to demonstrate direct hydrogen liquefaction technology. Gifford-McMahon (GM) cryocooler was employed to cool warm hydrogen gas to normal boiling point of hydrogen at 20K. Various cryogenic insulation technologies such as double walled vacuum vessels and multi-layer insulation were used to minimize heat leak from ambient. A liquid nitrogen assisted precooler, two ortho-para hydrogen catalytic converters, and highly efficient heat pipe were adapted to achieve the target liquefaction rate of 1L/hr. The liquefier has successfully demonstrated more than 1L/hr of hydrogen liquefaction. The system also has demonstrated its versatile usage as a very efficient 150L liquid hydrogen storage tank.

Research to Achieve Uniform Plasma in Multi-ground Capacitive Coupled Plasma

  • 박기정;이윤성;유대호;이진원;이정범;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.247.1-247.1
    • /
    • 2014
  • The capacitive coupled plasma is used widely in the semiconductor industries. Especially, the uniformity of the industrial plasma is heavily related with defect ratio of devices. Therefore, the industries need the capacitive coupled plasma source which can generate the uniform plasma and control the plasma's uniformity. To achieving the uniformity of the large area plasma, we designed multi-powered electrodes. We controlled the uniformity by controlling the power of each electrode. After this work, we started to research another concept of the plasma device. We make the plasma chamber that has multi-ground electrodes imaginary (CST microwave studio) and simulate the electric field. The shape of the multi-ground electrodes is ring type, and it is same as the shape of the multi-power electrodes that we researched before. The diameter of the side electrode's edge is 300mm. We assumed that the plasma uniformity is related with the impedance of ground electrodes. Therefore we simulated the imaginary chamber in three cases. First, we connected L (inductor) and C (capacitor) at the center of multi-ground electrodes. Second, we changed electric conductivity of multi-ground electrode. Third, we changed the insulator's thickness between the center ground electrode and the side ground electrode. The driving frequency is 2, 13.56 and 100 MHz. We switched our multi-powered electrode system to multi-ground electrode system. After switching, we measured the plasma uniformity after installing a variable vacuum capacitor at the ground line. We investigate the effect of ground electrodes' impedance to plasma uniformity.

  • PDF

A Simple, Reliable, and Inexpensive Intraoperative External Expansion System for Enhanced Autologous Structural Fat Grafting

  • Oranges, Carlo M.;Tremp, Mathias;Ling, Barbara;Wettstein, Reto;Largo, Rene D.;Schaefer, Dirk J.
    • Archives of Plastic Surgery
    • /
    • 제43권5호
    • /
    • pp.466-469
    • /
    • 2016
  • External volume expansion of the recipient site by suction has been proposed as a way of improving fat graft survival. The objective of this study was to present an innovative and simple intraoperative external expansion system to enhance small-volume autologous fat grafting (40-80 mL) and to discuss its background and its mechanism of action. In this system, expansion is performed using a complete vacuum delivery system known as the Kiwi VAC-6000M with a PalmPump (Clinical Innovations). The recipient site is rapidly expanded intraoperatively 10 times for 30 seconds each with a negative pressure of up to 550 mm Hg before autologous fat injection. During this repetitive stimulation, the tissues become grossly expanded, developing macroscopic swelling that regresses slowly over the course of hours following the cessation of the stimulus. The system sets various mechanisms in motion, including scar release, mechanical stimulation, edema, ischemia, and inflammation, which provide an environment conducive for cell proliferation and angiogenesis. In order to maintain the graft construct in its expansive state, all patients are encouraged postoperatively to use the Kiwi three times daily for one minute per session over the course of three days. The handling of this system is simple for both the patients and the surgeon. Satisfactory clinical outcomes have been achieved without significant complications.

Studies of the $TiO_2-Si$ Interface Bombarded by $Ar^+$ Ion Beam

  • Zhang, J.;Huang, N.K.;Lu, T.C.;Zeng, L.;Din, T.;Chen, Y.K.
    • 한국진공학회지
    • /
    • 제12권S1호
    • /
    • pp.63-66
    • /
    • 2003
  • It is experimentally shown that a $TiO_2$ film on Si(111) substrate was prepared by using the technique of D.C. reaction sputter deposition with $Ar^{+}$ ion beam bombardment, and a layer-like structure was observed from the depth profile of the interface between $TiO_2$ film and Si substrate with Scanning Electron Microscopy and Electron Probe. It was also surprisingly discovered that Ti atoms could be detected at about 9 $\mu$m depth. The $TiO_2$-Si interface bombarded by $Ar^{+}$ ion beams revealed multi-layer structures, a mechanism might be caused by defect diffusion, impurity and matrix relocation. Multi-relocations of impurity and matrix atoms were as a result of profile broadening of the $TiO_2$-Si interface, and the spread due to matrix relocation in this system is shown to exceed much more the spread due to impurity relocation.

ARPES study of Ultrathin Fe Grown on Cu (001) surface

  • Poornima, L.;Oh, Y.R.;Park, Y.S.;Kim, W.;Kim, C.G.;Hong, J.;Hwang, Chan-Yong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.350-350
    • /
    • 2011
  • The spin structure of Fe over layers on Cu (001), especially in region II is one of the unsolved problem for many years. We study the out - of - plane (OP) Fermi surfaces (FSs) of 7 monolayer Fe/Cu (001) films using angle resolved photo emission spectroscopy (ARPES). Ultrathin Fe was grown on Cu (001) substrate at room temperature and the experimental measurements were carried out at room temperature and low temperature. Fermi surfaces measured about $\frac{1}{4}$ of the Brillouin Zone (BZ) using photon energies ranging from 170 eV to 280 eV. Our results confirmed that ferromagnetic signal at 7 ML Fe on Cu (001) is nearly zero. These results are consistent with our recent x-ray magnetic circular dichroism (XMCD) and surface magneto - optic Kerr effect (SMOKE) experiments. Based on our observations we have made a simple model of this system, which explains all the experimental results.

  • PDF