• Title/Summary/Keyword: Kvp

Search Result 49, Processing Time 0.03 seconds

Plain Chest X-ray Diagnosis of Respiratory Disease (호흡기 질환에서 단순흉부 X-선 진단)

  • Kim, Sang-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.353-356
    • /
    • 1993
  • Advent of new imaging modalities such as computed tomography, magnetic resonance imaging and ultrasound contributed greately to the specific imaging diagnosis. However plain chest X-ray is still most prequently used for imaging diagnosis of respiratory disease in clinical pratic and it is important to make a good quality of X-ray film and good interpretation. The optimal chest X-ray should be taken with full inspiration without rotation and motion and the exposure is at the level of barely demonstrable thoracic vertebral disc space. It is recommended that higk KVP technique for detection of lesions which is overlaped by mediastinum, heart and rib cage. It is better to examine chest X-ray film start at some distance(6-8 feet) and closer to the film later on and the reader should not read a film in fatigue condition. The reading room should be quiet and relately dark illumination. It is important, to make a good X-ray film and good interpretation to reduce the observer error.

  • PDF

A Study on Radiation Dose in Mammography (유방촬영(乳房撮影)의 방사선량(放射線量)에 관(關)한 연구(硏究))

  • Choi, Jong-Hak;Jeon, Man-Jin;Kim, Young-Ill;Choi, Jong-Woon
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.31-36
    • /
    • 1981
  • We studied radiation dose in mammography through 34-46 kv range using acryl phantom. The obtained results were as follows: 1. Incident radiation was maximum with high kvp and thin added filtration. 2. Transmitted radiation by acryl phantom and its thickness were in reciprocal relationship. 3. The acryl thickness to produce comparable film density with soft tissue of breast was 6 cm. 4. The X-ray exposure for comparable density radiographs increased mammographic film more than medical x-ray film and the amount of x-ray exposure was directly proportional to the added filtration of x-ray beam. 5. The surface dose of x-ray exposure needed to produce film density of 1.0 for 6cm acryl phantom was 1,084-1,575mR in mammographic film and 476-625 mR in medical x-ray film.

  • PDF

Assessment of the Fertilizing Capacity of Domestic Animal Spermatozoa by Hamster Test II. Effects of incubation medium and X-ray irradiation on hamster test for boar spermatozoa (Hamster test를 이용한 가축정자의 수정능력 검정 II. 정액배지 및 X-선조사가 돼지정자의 Hamster test에 미치는 영향)

  • Kim Yong-Jun;Ji Dong-Boum
    • Journal of Veterinary Clinics
    • /
    • v.9 no.2
    • /
    • pp.373-390
    • /
    • 1992
  • To assay the fertilizing capacity of domestic animal spermatozoa by hamster test, semen were collected from 13 boars(Duroc. Landrace and Yorkshire) which had been proved to be fertile in the past. then, were preserved in BWW medium or in raw state at 18$^{\circ}C$ or at room temperature. The preserved semen were given each different treatment according to the experimental design and coincubated with zona-free hamster ova for 5 hours. The ova were stained by lacmoid and examined under phase contrast microscope to investigate the rates of ova bound with sperm(sperm binding). ova penetrated by sperm(penetration) and formation of a male pronucleus(pronucleus formation) and also numbers of both bound and penetrated sperm per ovum. Between BWW and TBM medium for boar sperm. no difference in the results of hamster test was obtained. The boar spermatozoa in BWW medium, BWW with caffeine, BWW with heparin, and BWW with both caffeine and heparin showed no difference in the results of hamster test. The boar spermatozoa in BWW medium containing both calcium and RSA showed considerably higher rates of sperm binding, penetration and pronucleus formation as well as higher numbers of both bound and penetrated sperm than those not containing calcium with or without BSA( p<0.01) and also the same results higher than that containing calcium without BSA( p< 0.05). The boar spermatozoa irradiated by X-ray(70 KVP, 20mA) for 3 seconds. then, maintained at 18$^{\circ}C$ for 18 hours showed considerably lower rate of sperm binding than all the other groups including the control and X-ray groups irradiated by smaller dose or maintained for shorter period(p<0.01), and also showed lower number of bound sperm than the other groups(p<0.01, p<0.05). All the control groups of both raw and diluted sperm in BWM medium showed higher rates of sperm binding, penetration and pronucleus formation as well as higher number of penetrated sperm than all the X-ray groups irradiated for 3 seconds(70KVP, 20mA) and maintained for either 3 or 18 hours (p<0.01, p<0.05). At the same time the control groups of diluted sperm showed considerably higher rates of sperm penetration and pronucleus formation than the control group of raw sperm( p<0.01). These results indicates that fertile boar sperm showed considerably lower rates In the results of hamster test, when incubated in the medium without calcium and irradiated by X-ray than when incubated in the medium with calcium and not irradiated by X-ray, respectively, to prove consequently that hamster test would be of great value in assaying the fertilizing capacity of boar spermatozoa.

  • PDF

Volume Change of Spiral Computed Tomography due to the Changed in the Parameters (파라미터의 변경에 따라 나선형 전산화 단층 촬영의 체적 변화)

  • Lee, JunHaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.307-311
    • /
    • 2013
  • This study examined the change of artifact volume by analyzing the level of image change associated with the setting of threshold through 3D imaging in scan parameter(slice thickness and helical pitch) and 3D image reconstruction to explore whether the presence of pathology was fully distinguished when CT was taken by lower dose than the existent dose to reduce exposure. Furthermore, this study attempted to investigate Scan Parameter acceptable in CT to reduce exposure dose. For materials and methods, silicon was used to produce samples. Five spherical samples were produced at 10-millimeter intervals(50, 40, 30, 20, and 10 mm) in diameter and were fixed at 120 Kvp of tube voltage and 50 mA of tube current. Varied slab thickness((1.0, 2.0, 3.0, 5.0, and 7.0mm) and Helical Pitch(1.5, 2.0, 3.0) were scanned. The image at an interval of 1.0, 2.0, 3.0, 5.0, and 7.0mm was transmitted to the workstation. Threshold(-200, -50, 50 ~ 1,000) was changed using the volume rendering technique, 3D image was reconstructed, and artifact volume was measured. In conclusion, 1.5 of Helical Pitch showed the least change of volume and 3.0 of helical pitch showed the greatest reduction of volume change. The experiment suggested that as slice thickness was increased, artifact volume was decreased more than actual measurement. Furthermore, in the 3D image reconstruction, when the range of threshold was set as -200 ~1,000, artifact volume was changed the least. Based on the results, it is expected to have an effect of reducing exposure dose.

Remote Measurement of the Automobile′s ECU Signals with KWP2000 using Bluetooth Module (Bluetooth 모듈을 이용한 KWP2000 차량 ECU신호의 원격 계측)

  • Choi Kwang-Hun;Kwon Tae-Kyu;Lee Seong-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.86-93
    • /
    • 2004
  • This paper presents the remote measurement of the ECU signals adopted with KWP 2000 protocol using the wireless communication technique of bluetooth. The bluetooth technology will be the most promising network paradigm which can open the new area in the information technology. Especially, bluetooth module is able to link all the electrical products and personal computers to cellular phone or PDA. This research has a try to design a wireless measurement model of ECU signal based on the car telemery system using bluetooth device. In order to measure the ECU signals, we designed the interface circuits which is able to communicate between the ECU system and the terminal circuits according to the ISO, SAE regulation of communication protocol standard. A microprocessor S3c341 OX is used for the system control and communication of ECU signals. The embedded system software is programmed to measure the ECU signals using the ARM compiler and ANCI C based on Micro/OS-II kernel to communicate between two bluetooth modules using bluetooth stack. The remote measurement of ECU signals using the bluetooth was designed and implemented to evaluate the performance of wireless network to the transmit measurement data. The possibility for the remote measurement of the self diagnosis signals of ECU adopted with KWP2000 protocol verified through the developed systems and algorithms in embedded system.

A LIMITED SURVEY OF DENTAL X-RAY UNITS AND PROTECTION IN KOREA (치과 X선발생장치 및 방어에 관한 조사연구)

  • Park T.W.
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.10 no.1
    • /
    • pp.57-61
    • /
    • 1980
  • In dental roentgenograph it is of mutual benefit to the patient and the dentist to use the minimum amount of radiation capable of producing roentgenograms with maximum interprtive informations. Recent increases in the number of diagnostic x-ray examinations made in this country have caused attention to be paid to the quantity of radiation delivered to the population and operator. The purposes of this study was to assess the quality of dental x-ray units, the amount of films, the average processing procedures and the radiation protection methods in korea. The results were as following: 1. Most of radiation generating system were used in low voltage such as 60Kvp, 10㎃. 2. High sensitivity films such as 'D' group of Kodak or Rinn were mainly used and average 14.7 films used per weeks. 3. Some dentists practiced visual processing technic in simple dark room, and others used instant films. 4. 68.26% of patient held the film themselves, but 27.30% were assisted by dentists film holding. 5. In radiation protection method, 7.85% of dentists had protection equipments such as protective barrier, 2.73% wore protective apron, 27.9% made it a rules to avoid beam, and 7.51% used to maintain a distance from the radiation source.

  • PDF

An Experimental Study of the Inverse Square Law (거리역자승(距離逆自承)의 법칙(法則)에 관(關)한 검사(檢討))

  • Kang, Hong-Seok;Kim, Chang-Kyun;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.9 no.1
    • /
    • pp.89-92
    • /
    • 1986
  • Generally the inverse square law (ISL) is applied by use of intensity scale method, that is distance scale method, when we practice sensitometry of X-ray film. It was reported that the failure of the ISL had occurred in the many experiments. Thus authors obtained some conclusions of the exponent value of distance by use of dosimeter and fluorescence meter in the range of tube voltage 60 - 120 kvp, that is the range of diagnostic energy. Those conclusions were as follows its exponents were produced as 2.1383 - 2.1763 in dosimeter, as 2.1190-2.2152 in fluorescence meter. This revealed that the perfect ISL was failded and that numerical differences were shown in each measurem apparatus. Therefore it is need to study the exponent at each tube voltage for the precise supply of fixed quantity on the characteristic curve's horizontal axis.

  • PDF

Anatomical Studies on Patterns of Branches of Hepatic Veins in Korean Native Cattle (한우(韓牛) 간정맥(肝靜脈)의 분지(分枝)에 관한 해부학적(解剖學的) 연구(硏究))

  • Kim, Chong-sup
    • Korean Journal of Veterinary Research
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 1987
  • The distribution of hepatic veins within the liver in 28 Korean native cattles were observed. Vinylite solution was injected into hepatic veins of seventeen specimens for cast preparation. The angiography was prepared in eleven specimens by injecting 30% barium sulfate solution into hepatic veins, and then radiographed on a X-ray apparatus (Shimadzu 800 MA 120 Kvp). 1. About two thirds or three quarters of the circumference of the Vena cava caudalis was embedded in the liver. The embedded portion was about 14~19cm in length. 2. The principal branches of the hepatic veins were Vena hepatica sinistra, Vena hepatica media, Vena hepatica dextra and Vena hepatica dorsolateralis; the three main hepatic veins were Vena hepatica sinistra, Vena hepatica media and Vena hepatica dextra. 3. The Vena hepatica sinistra joins the Vena cava caudal is near the esophageal impression of the liver. It gave off three or five branches to the left lobe. 4. The Vena hepatica media joined at the Vena cava caudalis close to the Vena hepatica sinistra. In all cases, Vena hepatica media opened near the diaphragmatic part of the liver than the Vena hepatica sinistra. It ran obliquely through the medial part of right lobe and quadrate lobe, giving off branches on each side. 5. The Vena hepatica dextra consisted of one(25 cases, 89.29%) or two separate veins(3 cases, 10.71%), joining to the Vena cava caudalis between the right and caudate lobes. 6. The flap of membranous tissue covered the dorsal half of the entrance of the Vena hepatica sinistra, media et dextra into the Vena cava caudalis. 7. The vestige of the ductus venosus persisted in the 12~18 months old cattles. 8. The anastomosis was observed in the intralobar and interlobar areas.

  • PDF

Studios in Selected Grid Ratio of Objective Thickness on X-ray Exposure (X선촬영시(X線撮影時) 피사체(被寫體) 두께에 따른 격자비(格子比) 선정(選定)에 관한 연구(硏究))

  • Yoon, Chul-Ho;Chu, Sung-Shil;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.5 no.1
    • /
    • pp.21-34
    • /
    • 1982
  • When unattenuated x-ray radiation passes through the object it is transmitted and scattered from objectes and impinging on the film. During this process certain radiation is absorbed within the object and others transmitted in reduced scattering. The scattering radiation influence upon radiation image quality, confining x-ray beam which means scattering radiation produce increased fog on x-ray film image and as a consequence decrease contrast and less detail of the film there for the elimination of fog and for absorbing scattered radiation, the grid has been used between the object and the film in order to rid of scattering rays. Using grid is good method for the qualification of the better image as well as in using air gap technique. The grid is easy to manipulate and promote good efficiency which is defined by ICRU and JIS. It is the purpose to study for eliminating scattered radiation from the tissue equivalent acryl phantom using grid, we have studied and evaluated the grid permeability about the x-ray exposure, the selection of grid ratio according to phantom thickness, on x-ray exposure are performed as follows. 1. The penetrating ratio of primary x-ray is remarkably decreased by increasing of the grid ratio, but it is almost not influenced in KVP difference and phantom thickness. 2. The scattered radiation is proportionaly increased by thickness of the phantom, having nothing to do with grid ratios. 3. The relative between the penetration rate of primary and secondary x-ray is improved by increasing grid ratio, and decreased by phantom thickness, and slightly decreased by high tube voltage. 4. The grid of 5:1 and 10:1 ratio are adequate to the phantom of 10cm and 15cm thickness, respectively.

  • PDF

SHEAR BOND STRENGTH OF DENTIN BONDING AGENTS ON DENTIN SURFACE TREATED WITH EUGENOL (유지놀 처리된 상아질 표면의 상아질 접착제의 전단결합강도에 관한 연구)

  • Yu, Hwa-Sung;Choi, Gi-Woon;Choi, Kyung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.550-560
    • /
    • 2000
  • In this study, shear bond strength of two bonding systems were measured and appearance of dentin surfaces were observed with SEM according to the storage time of eugenol on dentin surface, thus evaluated the effect of eugenol on bond strength of two dentin bonding systems. Control groups were directly bonded to dentin surface with One Step, Prime & Bond 2.1. Experimental groups were divided into experimental I and II according to dentin bonding agents. After eugenol application, dentin surfaces were bonded with One Step and Prime & Bond 2.1 according to the each storage time of immediately, 3min, 24hour, 48hour and 1week, and then control and experimental groups were filled with light cured composite resin(Z-100). After 24 hours water storage at $37^{\circ}C$, all samples were subjected to a shear load to fracture at a cross head 1.0mm/min with Instron universal testing machine(No. 4467). Etched dentin surface storaged for each time of immediately, 3min, 24hour, 48hour and 1 week after eugenol application were observed under Scanning Electron Microscope(Hitachi S-2300) at 20kvp. The data were evaluated statistically with two-way ANOVA and Tukey's HSD. The results were as follows; 1. Shear bond strengths were higher in control groups than in the experimental groups. 2. As storage time was increased after eugenol application, the shear bond strengths were decreased in experimental groups. 3. In experimental I, II the shear bond strengths were the lowest in which storage time was 1 week after eugenol application. 4. As storage time was increased after eugenol application, etched dentin surfaces showed obstructed dentinal tubule.

  • PDF