Browse > Article
http://dx.doi.org/10.7742/jksr.2013.7.4.307

Volume Change of Spiral Computed Tomography due to the Changed in the Parameters  

Lee, JunHaeng (Dept. of Radioiogy, Nambu University)
Publication Information
Journal of the Korean Society of Radiology / v.7, no.4, 2013 , pp. 307-311 More about this Journal
Abstract
This study examined the change of artifact volume by analyzing the level of image change associated with the setting of threshold through 3D imaging in scan parameter(slice thickness and helical pitch) and 3D image reconstruction to explore whether the presence of pathology was fully distinguished when CT was taken by lower dose than the existent dose to reduce exposure. Furthermore, this study attempted to investigate Scan Parameter acceptable in CT to reduce exposure dose. For materials and methods, silicon was used to produce samples. Five spherical samples were produced at 10-millimeter intervals(50, 40, 30, 20, and 10 mm) in diameter and were fixed at 120 Kvp of tube voltage and 50 mA of tube current. Varied slab thickness((1.0, 2.0, 3.0, 5.0, and 7.0mm) and Helical Pitch(1.5, 2.0, 3.0) were scanned. The image at an interval of 1.0, 2.0, 3.0, 5.0, and 7.0mm was transmitted to the workstation. Threshold(-200, -50, 50 ~ 1,000) was changed using the volume rendering technique, 3D image was reconstructed, and artifact volume was measured. In conclusion, 1.5 of Helical Pitch showed the least change of volume and 3.0 of helical pitch showed the greatest reduction of volume change. The experiment suggested that as slice thickness was increased, artifact volume was decreased more than actual measurement. Furthermore, in the 3D image reconstruction, when the range of threshold was set as -200 ~1,000, artifact volume was changed the least. Based on the results, it is expected to have an effect of reducing exposure dose.
Keywords
Exposure Dose; Helical Pitch; Artifact; Parameter;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Hongmoon Jung, Doyeon Won, Taegeon Kwon, Jaeeun Jung, Measurement of Space Dose Distribution during Exposure Micro Computed Tomography (${\mu}$-CT) for Scattering Rays, Journal of the Korean Society of Radiology, Vol. 7, No. 1, pp. 45-50, 2013.   과학기술학회마을   DOI   ScienceOn
2 UNSCEAR, "Sources and Effects of Ionizing Radiation", UNSCEAR 2010 Report, New York, United Nations, 2010.
3 Byungkoo Lee, Suman Kang, Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy, Journal of the Korean Society of Radiology, Vol. 7, No. 2, pp. 145-149, 2013.   과학기술학회마을   DOI   ScienceOn
4 고신관 외, 방사선물리학, 고문사 , 2003.
5 고인호, 김경근, 김동윤 등, Textbook of Computed Tomography, 청구문화사, pp.29, 2005.
6 이종호, 저선량 흉부CT를 위한 scan parameter선택에 관한 연구, 남부대학교 보건학석사학위, 2007.
7 고인호, 김경근, 김동윤 등, Textbook of Computed Tomography, 청구문화사, pp.182, 2009.
8 오유환, 다중검출기 CT (Multidetector-row CT)의 원리와 임상적 적응, 가정의학회지, Vol. 27, No. 11, pp.249, 2006.
9 이지연, 김기덕, 박창서, 상층두께와 관심영역의 크기 변화가 CT 번호에 미치는 영향, 대한구강악안면방사선학회지 Vol. 31, pp.85-91, 2001.   과학기술학회마을
10 Kersemans V, Thompson J, Cornelissen B, Woodcock M, AllenPD, et al.Micro-CT for anatomic referencing in PET and SPECT: radiation dose, biologic damage, and image quality, J Nucl Med., Nov, Vol. 52 No.11, pp. 1827-1833, 2011.   DOI
11 Rothkamm K, Balroop S, Shekhdar J, Fernie P, Goh V.Leukocyte DNA damage after multi-detector row CT: a quantitative biomarker of low-level radiation exposure, Radiology, an Vol. 242 No. 1, pp. 244-251, 2007.   DOI   ScienceOn