• Title/Summary/Keyword: Kv1.3

Search Result 180, Processing Time 0.024 seconds

A Study on the Radio Interference due to the Corona Noise of 345 KV Transmission Line (345KV 송전선에 의한 CORONA 잡음 전파장해 연구)

  • 최기호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.4 no.1
    • /
    • pp.32-37
    • /
    • 1979
  • The corona noise level at the place 10m and the frequency 1MHz from the new 345KV transmission line is 72dB in the maximum rain-fall and 63dB due to the wet conductors. The synthesized corona noise level of all 3 phases dominantly depends on the phase which has maximum corona level among them. The measured characteristic of the variation with distance from the line coincided well with the theoretically calculated value in this paper. The corona noise level was the highest level in rainy weather or snow-fall. It takes a few hours, for the corona noise to be stable after a rain-fall or snow-fall. The measured value of the corona noise level corresponds quite well with the formula for the corona noise level revision. It was necessary to quantize S/N ratio into radio reception quality for the radio interference due to the transmission line. Some regulations for radio reception quality were defined through long term experiments and ratings by ITU, IEEE comittee, NHK in Japan and others. Fixing our own regulation about radio reception quality should be required.

  • PDF

A study on electron beam lithography for 0.1$\mu\textrm{M}$ T-gate formation at P(MMA/MAA)/PMMA structure (PMMA/P(MMA/MAA) 구조에서 0.1$\mu\textrm{M}$ T-gate 형성을 위한 전자빔 리소그래피 공정에 관한 연구)

  • Choe, Sang-Su;Lee, Jin-Hui;Yu, Hyeong-Jun;Lee, Sang-Yun
    • Korean Journal of Materials Research
    • /
    • v.5 no.1
    • /
    • pp.96-103
    • /
    • 1995
  • This art~cle reports on the formation of T - Gate with O.1$\mu$m foot and 0.4$\mu$m head width at PMMA/P( MMA/MAA) resist structure using a 30KV electron beam lithography system. From the result of Monte Carlo simulation on PMMA/P( MMA/MAA)/GaAs, we obtain the dissipation energy ratio of forwardscattered electron and backscattered electron within 0.1$\mu$m scattering radius is 19.5 : 1 0.1$\mu$m T - gate has been formed with 30KV gaussian electron beam at a 440$\mu C/\textrm{cm}^2$ dosage. The gamma value of PMMA and P(MMA/MAA) at MIBK : IPA=l : 1 developer was 2.3. The overlay accuracy(3$\sigma$) from mix-andmatch of optical stepper and Ekeam lithography system for fabricating HEMT device is accomplished below 0.1$\mu$m.

  • PDF

A Study on High Kilovoltage Technique in taking Chest Radiogram. (흉부(胸部) 고관전압(高管電壓) 촬영조건(撮影條件)에 관(關)한 검토(檢討))

  • Kang, Hong-Seok;Kim, Chang-Kyun;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.37-43
    • /
    • 1979
  • High kilovoltage technique as compared with low kilovoltage in taking chest radiogram has much advantages. Authors performed an experiment by using acryl phantom to make the technical chart at 120KV and obtained the results as follows; 1. Increase and decrease of tube voltage in thickness change was 3.2KV per cm at variable technic chart. 2. At fixed kilovoltage technic chart, increase and decrease was $0.12{\sim}0.2$ mAs per cm in chest thickness. 3. Increase and decrease of distance was 1.3inches per cm in thicknese change

  • PDF

Analysis of discharge characteristics of KrF laser system with UV preionization (자외선 예비전리 KrF 레이저의 방전특성 해석)

  • Choi, Boo-Yeon;Lee, Choo-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.642-646
    • /
    • 1989
  • We have developed analysis program of discharge chracteristics of KrF laser system with charge transfer type, that studied about deposited energy, nonlinear discharge, and electron number density in the laser tube. With this program, voltagr, current, and deposited energy was calculated 27 KV,32.6 KA,200 MW at total pressure 2 atm and charging voltage 33 KV, respectively. At this condition, circuit parameters are L1=150nH, R1=$0.3{\Omega}$, L2=15nH, R2= $0.3{\Omega}$. In addition, nonlinear discharge resistance and electron number density was calculated ${\infty}{\sim}0.17{\Omega}.1{\times}10^{16}cm^{-3}$, respectively.

  • PDF

Design of Gate Driver Chip for Ionizer Modules with Fault Detection Function (Fault Detection 기능을 갖는 이오나이저 모듈용 게이트 구동 칩 설계)

  • Jin, Hongzhou;Ha, PanBong;Kim, YoungHee
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.132-139
    • /
    • 2020
  • The ionizer module used in this air cleaner supplies high voltages of 3.5KV / -4KV to the discharge electrode HV+ / HV- using a winding transformer to generate positive and negative ions by electric field radiation of carbon fiber brush. The ionizer module circuit using the existing MCU has the disadvantage of large PCB size and expensive price, and the gate driver chip using the existing ring oscillator has oscillation period sensitive to PVT (Process-Voltage-Temperature) fluctuation and there is risk of fire or electric shock because there is no fault detection function by short circuit of HV+ and GND as well as HV- and GND. Therefore, in this paper, even though PVT fluctuates, by using 7-bit binary up counter, HV+ voltage reaches the target voltage by adjusting oscillation period. And an HV+ short fault detection circuit for detecting a short circuit between HV+ and GND, an HV- short fault detection circuit for detecting a short circuit between HV- and GND, and an OVP (Over-Voltage Protection) for detecting that HV+ rises above an overvoltage are newly proposed.

23KV Y배전방식 연구 1

  • 민정근
    • 전기의세계
    • /
    • v.15 no.3
    • /
    • pp.15-24
    • /
    • 1966
  • 본 연구실험은 특고배전방식에 대한 제문제중 특히 아래 세 문제에 중점을 두어 기초적자료를 구하는데 연구의 목적을 두었다. 1. 고저압선의 혼촉사고시 중성선의 대지전위상승에 대하여 2. 고압선의 1선지락고장시(특히 고저항접지) 지락저학의 변화와 접지사고검출방법에 대하여 3. 연접한 통신선의 유도장해에 대하여 연구한다.

  • PDF

Study on a Coaxial Plasma Gun (III)

  • Bak, Hae-Ill;In, Sang-Ryul;Chung, Kie-Hyung;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.163-170
    • /
    • 1980
  • A Mather type plasms gun is operated at below 1 torr with a energy storage system (4KJ, 16.5KV, 35nH) to study the conditions of the efficient plasma focus. When the $D_2$ gas filling pressure is 0.18 torr and the stored energy is 3.8KJ, the discharge current of max. 180KA is obtained and the average axial velocity of the plasma is about $7cm/\mu\textrm{s}$. This is lower than the calculated velocity with above conditions by the snow-plow model. The discrepancy is due to the currents flowing over the insulator surface. The plasma focus occurs at low pressure compared with the results obtained by Bruzzone. The reasons are such that the plasma gun employed in this experiment is large for tile stored energy and the concentration of the residual gas is comparatively high. It is confirmed by a Long counter that the neutrons are generated from the dense plasma focus.

  • PDF

Induction coordination of the 154KV system with direct grounding (154KV 계통직접접지전환에 따른 유도협조)

  • 손필영;원준희
    • 전기의세계
    • /
    • v.18 no.1
    • /
    • pp.33-37
    • /
    • 1969
  • 한전은 1968년 11월 3일 오전 10시 04분을 기하여 154KV 전계통의 직접접지방식 전환을 단행하였다. 종전의 P.C(소고선륜) 중성점접지방식을 직접접지방식으로 전환한것으로서 전력사상 특기 할 만한 근대화사업이며 다년간을 두고 추진해온 중요과제였다. 전력계통의 확대와 복잡화는 선진국가에서도 실시하고 있는 직접접지방식의 채택을 불가변하게 하였고 또한 1차 AID송배전차관도 이의 채택을 조건부로 승인되었던 것으로서 1968년 이후에 건설되는 송변전기기는 직접접지계에서만 운전할 수 있는 절연Level 650KV급이 도입되어 부산화력발전소 3호기가 준공되는 1968년 10월말까지는 직접접지전환이 반드시 이루어져야 하는 실정에 놓여 있었다. 그런데 직접접지방식의 단점인 인접통신선에 미치는 유도장해를 해결하는 문제가 다년간을 두고 진지하게 검토되어 왔으나 해결이 늦어지고 있었다. 사유는 154KV 계통에 인근된 통신선이라면 체신부, 내무부, 교통부, 국방부등 여러기관의 것이 있는데, 유도장해보안방법과 유도보상비문제에 대하여 전력측(상공부, 한전)과 통신측(상기의 체신부등)의 견해차가 해소되지 않기 때문이었다. 그것이 1968년 5월에 와서 전력.통신쌍방이 범국가적입장에서 제반애로를 무릅쓰고 최소한의 투자로 가능한 범위내의 보안책으로서 우선 Arrester 보안방식을 채택하기로 합의되어 경제장관회의를 거쳐 시공하기에 이른것이다. 이 란을 빌려 이 사업의 필요성과 경위및 통신선유도장해방지를 위한 보안방식내용을 간단히 소개함으로써 앞으로 이 분야의 항구적인 유도대책연구에 다소나마 참고가 된다면 다행으로 생각하겠다.면서 예측강우의 질이 저하되기 시작하였으나 QPM을 합성함으로써 생산한 BQPF는 보다 신뢰성있고 양호한 결과를 얻을 수 있었다. 이러한 결과들은 향후 정량적 분포형강우 예측을 이용한 실시간 홍수유출 예측시 댐운영자는 리드타임(홍수선행시간)을 충분히 확보함으로서 안정적이고 예측 가능한 홍수조절을 하는데 도움을 줄 수 있을 것으로 기대된다. 이와 같이 다양한 단기저수지 유입량의 예측정보 제공으로 다목적댐 저수지 운영모형의 효용성을 제고하여 향후 실제 저수지 유입량 예측에 이용함으로써 저수지 단기운영효율 개선에 기여할 수 있을 것으로 사료된다.다. 이것은 여름철 강수량이 증가하고, 호우발생빈도, 특히 8월의 강수일수가 증가하고 있다는 것과 밀접한 관련이 있다. 여름과 가을에 우리나라에 영향을 미치는 태풍의 수는 뚜렷한 추세를 보이지 않으나, 2002년 루사, 2003년 매미로 인하여 각각 6조원, 4조원 이상의 막대한 피해가 발생하였다. 태풍에 의한 피해액은 GDP 대비 약 0.9%(태풍 루사)로 최근 경제상장률과 비교해 보면, 상당한 비율을 차지한다. 우리나라에 영향을 미치는 태풍은 연근해의 해수면 온도가 높아지면 세기가 강해질 가능성이 높다. 폭설과 한파일수도 평년대비 최근 10년 감소하였고 일최저기온이 영하 $10^{\circ}C$ 이하인 날도 연간 발생일수가 감소하였다. 최근 10년간 우리나라 기후의 변화특성은 기온상승과 더불어 서리종료일이 앞당겨지고 열대야가 증가하고 폭설, 한파, 겨울철 일최저기온 영하 10도 이하인 날의 감소 등이 나타나고, 여름철 재해의 원인인 호우일수는 증가하는 추세이다.

  • PDF

345KV 초고압 송전에 따른 전력계통 운용방안

  • 서형열;신대흥;윤갑구
    • 전기의세계
    • /
    • v.26 no.1
    • /
    • pp.36-44
    • /
    • 1977
  • 본고에서는 (1) 대전력장거리송전계통의 안정도향상 문제, (2) 기간송전계통의 단락전력압제 문제, (3) 대전력장거리송전계통의 계통전압과 주파수의 유지 문제, (4) 사고파급에 의한 광범위대정전의 방지 문제의 문제들에 대하여 초고압계통의 운용에 경험이 있는 외국의 전력계통운용방안들을 참고로하여 그의 개요를 기술코자 한다.

  • PDF