• Title/Summary/Keyword: Kv1.3

Search Result 180, Processing Time 0.028 seconds

The effect of rapid thermal annealing treatment for ferroelectric properties of PZT thin films (RTA를 이용한 후열처리가 PZT 박막의 강유전 특성에 미치는 영향)

  • Ju, Pil-Yeon;Park, Young;Jeong, Kyu-Won;Lim, Dong-Gun;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.136-139
    • /
    • 1999
  • The post-annealing treatments on RF (Radio Frequency) magnetron sputtered PZI(Pb$\_$1.05/(Zr$\_$0.52/, Ti$\_$0.48/)O$_3$thin films(4000${\AA}$) have been investigated. for a structure of PZT/Pt/Ti/SiO$_2$/Si Crystallization pproperties of PZT films were strongly dependent on RTA(Rapid Thermal Annealing) annealing temperature. We were able to obtain a perovskite structure of PZT at a low temperature of 600$^{\circ}C$. P-E curves of Pd/PZT/Pt capacitor annealed at 700$^{\circ}C$ demonstrate typical hysteresis loops. The measured values of P$\_$r/, E$\_$c/, by post annealed at 700$^{\circ}C$ were 12.1 ${\mu}$C/$\textrm{cm}^2$, 120KV/cm respectively.

  • PDF

Rhabdomere Formation in Late Pupal Stage of Drosophila melanogaster; Observation Using High-Pressure Freezing and Freeze-Substitution, and High-Voltage Electron Microscopy (초고압 동결장비와 초고압투과전자현미경을 이용한 초파리의 감간분체 형성과정의 구조분석)

  • Mun, Ji-Young;Arii, Tatsuo;Hama, Kiyoshi;Han, Sung-Sik
    • Applied Microscopy
    • /
    • v.37 no.1
    • /
    • pp.35-42
    • /
    • 2007
  • The late pupal stage of Drosophila melanogaster occurs immediately before the completion of retinal development, during which the rhabdomere rapidly forms. In this period, the photoreceptor cells were fixed and dehydrated using a high-pressure freezer (HPF) and freeze substitution (FS) technique, which is the most effective in preserving the cell structures, and observed using high-voltage electron microscopy (HVEM) at 1000 KV. The rhabdomere was classified structurally into three types of formation patterns using stereo-tiling image of thick sections. Initially, hexagonal arrays of rhabdomere existed in different angles. In addition, small pieces of rhabdomere could be observed in the cytoplasm of the photoreceptor rolls, which were visible during the profess of rhabdomere formation. In addition, multiple layers of rhabdomere strings were observed. We observed there are at least three types of vesicles related to rhabdomere formation in photoreceptor cells. In addition, it was found that these vesicles initiate the formation of the rhabdomeres during the pupal stage. Collectively, these data suggest that rhabdomeres were mainly formed through vesicles, and that parts of the rhabdomere formed first and then gathered and formed rhabdomeres in the late pupal stage.

A STUDY ON THE SHEAR BOND STRENGTH AND SCANNING ELECTRON MICROSCOPIC INVESTIGATION OF DENTIN BONDING AGENTS (상아질 접착제의 전단결합강도 및 주사전자현미경적 연구)

  • Lee, Gi-Hwan;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.289-302
    • /
    • 1995
  • The purpose of this study was to estimate the shear bond strength and observe the fractured and interfacial surfaces of various dentin bonding agents used conjunction with a visible light cured composite. The senentytwo human premolars and molars extracted due to periodontal or orthodontic reasons were used and randomely divided into six groups. All the prepared dentin surfaces were treated with Superbond D-liner, Scotchbond Multi-Purpose, All-Bond 2 and Prisma Universal Bond 3 accroding to the manufacturer's instructions. Six specimens were then demineralized in 10 % HCl for 24 hours and the other six specimens were not demineralized in order to observe the interfacial surfaces with Hitachi X-450 SEM at 25Kv. Also shear bond strength were obtained using an Instron Testing Machine with a crosshead speed of 1mm/min. The following results were obtained : 1. Although shear bond strength of Superbond D-Liner(17.35 MPa) and Scotch-bond Multi-Purpose group(17.29 MPa) were higher than the All-Bond 2(12.80 MPa) and Prisma Universial Bond 3 (13.43 MPa), there were no significant statistic differences in the shear bond strength between 4 groups.(P<0.05) As a result of etching to dentin in Prism a Universial BOND 3 experimentally, the resin tag was formed, but shear bond strength was decreased. 2. The resin tag into the opened dentinal tubule was formed in Superbond D-Liner, Scotchbond Multi-Purpose, All-Bond 2(etching) and Prisma Universial Bond 3(etching), but not in the All-Bone 2 and Prism a Universial Bond 3(non-etching). 3. Strong, durable bonds between dentin and dentinal bonding agents are essential, not only resin tag into the dentinal tubules, but also hybrid layer.

  • PDF

Evaluation on Usefulness of Applying Body-fix to Liver Cancer Patient in Tomotherapy (간암환자의 토모치료시 Body-fix 사용유무에 따른 유용성 평가)

  • Oh, Byeong-Cheon;Choi, Tae-Gu;Kim, Gi-Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • Purpose: In every time radiation therapy set up errors occur because internal anatomical organs move due to breathing and change of patient's position. These errors may affect the change of dose distribution between target area and normal structure. This study investigates the usefulness of body-fix in clinical treatment. Materials and Methods: Among 55~60 aged male patients who has hepatocellular carcinoma in area of liver's couinaud classification, we chose 10 patients and divided two groups by using body-fix or not. When applying body-fix, we maintained a vacuum of 80 mbar pressure by using vacuum pump (Medical intelligence, Germany). Patients had free breathing with supine position. After working to fuse and consist MV-CT (megavoltage computed tomography) with KV-CT (kilovoltage computed tomography) obtained by 5 times treatments, we compared and analyzed set up errors occurred to (Right to Left, RL) of X axis, (Anterioposterio, AP) of Z axis, (Cranicoudal, CC) of Y axis. Results: Average Set up errors through image fusion showed that group A moved $0.3{\pm}1.1\;mm$ (Cranicoudal, CC), $-1.1{\pm}0.7\;mm$ (Right to Left, RL), $-0.2{\pm}0.7\;mm$ (Anterioposterio, AP) and group B moved $0.62{\pm}1.94\;mm$ (Cranicoudal, CC), $-3.62{\pm}1.5\;mm$ (Right to Left, RL), $-0.22{\pm}1.2\;mm$ (Anterioposterio, AP). Deviations of X, Y and Z axis directions by applying body-fix indicated that maximum X axis was 5.5 mm, Y axis was 19.8 mm and Z axis was 3.2 mm. In relation to analysis of error directions, consistency doesn't exist for every patient but by using body-fix showed that the result of stable aspect in spite of changes of everyday's patient position and breathing. Conclusion: Using body-fix for liver cancer patient is considered effectively for tomotherapy. Because deviations between group A and B exist but they were stable and regular.

  • PDF

Study on electron beam treatment on $Cu_2Se$ thin films by DC sputtering method (DC sputter방식으로 제조된 $Cu_2Se$ 박막의 전자빔 처리에 따른 특성 연구)

  • Kwon, Hyuk;Kim, ChaeWoong;Jung, SeungChul;Kim, DongJin;Park, InSun;Jeong, ChaeHwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.53.1-53.1
    • /
    • 2011
  • 현재 태양전지시장에서 비중이 많은 실리콘 태양전지는 높은 효율에 비해 제조 단가가 비싸다는 단점을 가지고 있다. 이에 비해 칼코파라이트 구조의 $CuInSe_2$ (CIS)계 화합물은 직접 천이형 반도체로서 높은 광흡수 계수($1{\times}105cm-{\acute{e}1$)와 밴드갭 조절의 용이성 및 열적 안정성 등으로 인해 고효율 박막 태양전지용 광흡수층 재료로 많은 관심을 끌고 있다. CIS 계 물질에 속하는 Cu(InGa)$Se_2$ (CIGS) 태양전지의 경우 양산화에 sputtering방식사용하고 Showa Shell에서는 대면적 CIGS 모듈 효율 13.4%를 달성한 바 있다. 현재 CIGS는 열처리하는 방법으로 selenization 공정을 사용하는데 이 공정은 유독한 $H_2Se$ gas를 이용해야 한다는 점과 긴 시간 동안 열처리를 해야 하는 단점을 가지고 있다. 따라서 이러한 단점을 보완하기 위해 본 연구에서는 전자빔을 사용하여 후속 공정을 실시하였다. 전자빔을 사용할 경우 낮은 온도에서 precursor를 처리하며 짧은 시간에 공정이 끝난다는 장점이 있다. 본 연구에서는 sodalime glass위에 조성비(Cu 60.87% Se 38.66%)인 Cu_2Se$ target(4.002"${\times}0.123$") 을 DC sputter를 이용하여 DC power를 50W,100W를 주고 Working pressure를 20,15,10,5,3,1mtorr로 조절하여 증착하였다. 전자빔의 세기 조건을 3Kv, Rf power 200W, Ar 7sccm로 전자빔 조사 시간을 1,2,3,4,5min으로 늘려가며 최적화 실험 하였고 최적화된 조건으로 $Cu_2Se$ target에 조사 하였다. 박막의 특성평가는 전자빔 조사 전/후에 대해 XRD, SEM, XRF, Hall measurement, UV-VIS을 이용하여 분석평가를 하였다. 이 실험은 $Cu_2Se$상이 자라는 특성과 표면 상태에 따라 CIGS박막을 증착하였을 때 나타나는 효율 변화를 알아 보기위한 초기 공정 실험이다.

  • PDF

Development of Recycling Technology for Used Cables (폐전선 재활용 기술개발)

  • 양정일;오정완;최우진;황선국
    • Resources Recycling
    • /
    • v.3 no.2
    • /
    • pp.28-34
    • /
    • 1994
  • A part of used cables, such as electric and communication cables has already been recycled by using simple processing methods. However, it has been found that the main problems in recycling of the used cables are insufficient treatment of fine stranded wires and low recovery of copper by air separation process. It has been shown that copper can be effectively separated from the PE using a solvent treatment method. In the present study, the used communication wires having diameter of 0.4 mm are treated in the mixing solution of toluene and water at $86^{\circ}C$ for about 10 minutes. In the solvent treatment, the copper wires recovered have 10~15mm length, which are much longer than that of 1~2mm length copper wires recovered by air table concentration method used in current recycling plants. The process consisting of cutting, air separation and electrostatic separation would be recommendable for the treatment of mixed cables. In this investigation, fine copper powders can also efficiently be recovered from insulation materials using electrostatic separator at the conditions of 20~50RPM roller speed and 15~30KV high DC power.

  • PDF

A STUDY ON THE RESIN IMPREGNATION AND SHEAR BOND STRENGTH BY VARIOUS DENTIN CONDITIONERS (수종 상아질 표면처리제에 의한 레진 침투 및 전단결합강도에 관한 연구)

  • Lee, Kwang-Won;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.201-216
    • /
    • 1990
  • A variety of surface pre-treatments have been advocated to prepare the dentin prior to placement of a bonding agent. The purpose of this study was to evaluate the effect of various dentin conditioners upon the degree of resin impregnation to the dentinal tubules and the shear bond strength of a new dentinal bonding agent (Scotchbond 2) used in conjunction with a visible light cured composite (Silux). The healthy eighty human molars extracted due to periodontal or orthodontic reasons were used and randomly divided into five groups. All the grinded dentin surfaces were conditioned with 3% $H_2O_2$, Cavity Cleanser (Columbus/Bayer), Dentin Conditioner (GC Inter. Corp.), Scotchprep (3M Co.) according to the manufacturer's directions. The specimens were then demineralized in 10% HCl for 20 sec. and 24 hrs. in order to observe the resin tags in Hitachi X-450 scanning electron microscope at 25KV. Also, shear strengths were obtained using an Instron Testing Machine with a cross head speed of 1 mm/min. The following results were obtained ; 1. In group treating with Dentin Conditioner and Scotchprep, the resin strings were formed on most of the surfaces and penetrated more than $50{\mu}m$ into the tubules. 2. The inner surface of resin treated with Cavity Cleanser, indicating the resin strings formed partly and penetrated about in depth of $30{\mu}m$. 3. In control and experimental group treated with 3% $H_2O_2$, the resin tags were not formed, if any, penetrated shortly. 4. Shear bond strengths in groups treating with Dentin Conditioner and Scotchprep were statistically significant increase than with 3% $H_2O_2$. (P<0.01). 5. The Scotchprep treatment group was significantly higher in shear strength than groups treated with no conditioning and Cavity Cleanser.(P<0.01) 6. Shear bond strengths evaluated were gradually increase in proportion to the tag length of resin impregnation.

  • PDF

The Comparison of Knee Joint Displaying between The Anteroposterior Weight Bearing View and the Metatarsophalangeal View with Osteoarthritis Patients (골관절염 환자의 촬영방법에 대한 고찰 : AP-WB(Weight-bearing AP), MTP(semiflexed) 촬영법의 비교 고찰을 중심으로)

  • Jeon, Ju-Seob;Park, Hwan-Sang;Moon, Il-Bong;Moon, Ju-Wan;Choi, Nam-Kil;Kim, Chang-Bok;Eun, Sung-Jong
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • Objective : The aim of this study was to compare the knee joint displaying between the anteroposterior weight bearing(AP-WB) View and the metatarsophalangeal(MTP) view for assessing joint space narrowing(JSN) and osteophytes in osteoarthritis patients. Subjects and Materials : Two hundreds of twenty patients(38 men) who came rheumatoid caused by knee pain, had both AP-WB and MTP views taken on a day. Radiographs were evaluated independently by 13 experienced observers(3 orthopedics surgeon, 2 rheumatogist, 3 radiologist, 5 radiological technologist) They assessed JSN and osteophytes using by PACS monitor JSN was scored by the optic evaluation to the nearest at the narrowest point in medial compartments of the tibiofemoral joint in both knees. Osteophytes were graded 0 to 3(bad 0, not bad 1, good 2 and very good 3) according to a standard atlas. All exam was using by Philips(Buckey Diagnostic-TH) X-ray material. Exposure condition was 60 kv, 8 mAs and 100 cm focus to film distance. Results : JSN was scored $1.32{\pm}0.050$ in AP-WB view, $2.51{\pm}0.046$ in MTP view. MTP view of JSN score is higher to AP-WB view significantly(p<0.05). Osteophytes scored $2.14{\pm}0.054$ in AP-WB view, $2.10{\pm}0.054$ in MTP view. There was no difference(p<0.05) between MTP view and AP-WB view in osteophytes. But MTP view was more reproducible than AP-WB view Conclusions : Joint space narrowing is most important factor to diagnosis with knee joint Osteoarthritis patients. This study was summarized as follows; In comparision of JSN, MTP view was more widely displayed than AP-WB view. In comparision of Osteophytes, there was no difference between MTP view and AP-WB view. It was concluded MTP view was more useful method to diagnosis of knee joint Osteoarthritis patients.

  • PDF

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

An Experiment on Scattered-ray Content Ratio and Skin Dose according to the Exposure Condition for Chest Radiography (흉부 X선촬영조건의 변화에 따른 산란선 함유율과 피부선량에 관한 연구)

  • Park, Young-Sun;Ahn, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.3-9
    • /
    • 1992
  • In an experiment using chest radiography, the authors measured the scattered ray content ratio and exposed skin dose giving varieties to the object thickness, tube voltage, additional filters and gird. The result was as follows, In the 80 kV the required mAs for the density 1.8 was $10{\sim}20$ times as much as in the 140 kV, and when 10 : 1 grid was used the required mAs was $3{\sim}5$ times as much as when grid was not used. Under the same tube voltage the scattered ray content ratios were increased as the additional filter thickness became thicker. And when 10 : 1 grid was used the ratio could be decreased $2{\sim}5$ times as much as when grid was not used. Skin doses exposed to the patients were increasing as the thickness of the object became thicker, and were decreasing as filters became thicker while showing slow the decreasing effects above the 1/8 VL. And when the grid was used skin doses were increased $2{\sim}4$ times as much as when not used. In order to improve the image qualities while reducing the exposures in the chest radiography, the authors suggest followings. The additional filters up to the 1/2 VL will be suitable according to the thickness of the objects in the 80kv, while the 10 : 1 grid and additional filter of 1/8 VL will be suitable in the 140 kV.

  • PDF