• Title/Summary/Keyword: Ku-band

Search Result 362, Processing Time 0.031 seconds

Fabrication of Two-Dimensional Array Hydrophones and Application to Ultrasonic Field Measurement (2차원 배열 수중청음기의 제작과 초음파 음장 측정에의 응용)

  • Ha, Kang-Lyeol;Kim, Moo-Joon;Kang, Gab-Joong;Hyun, Byung-Gook;Chae, Min-Ku;Imano, Gazuhiko
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.320-328
    • /
    • 2001
  • Two-dimensional array hydrophones with $8{\times}8$ elements were designed and fabricated using the PVDF(Polyvinylidene fluoride) piezoelectric film, and the method and system for ultrasonic field measurement in several MHz $\sim$ tens of MHz band using the hydrophones was established. The characteristics of frequency response relating to the backing materials were analyzed with the Mason equivalent circuit for design, and the accuracy of ultrasonic field measurement relating to the sizes and kerfs of piezoelectric elements was discussed. Good results of the measurement of ultrasonic field formed by a circular plane transducer of 2.25MHz in water were obtained by the system with the array hydrophones.

  • PDF

Performance Analysis of Sensor Systems for Space Situational Awareness

  • Choi, Eun-Jung;Cho, Sungki;Jo, Jung Hyun;Park, Jang-Hyun;Chung, Taejin;Park, Jaewoo;Jeon, Hocheol;Yun, Ami;Lee, Yonghui
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.303-314
    • /
    • 2017
  • With increased human activity in space, the risk of re-entry and collision between space objects is constantly increasing. Hence, the need for space situational awareness (SSA) programs has been acknowledged by many experienced space agencies. Optical and radar sensors, which enable the surveillance and tracking of space objects, are the most important technical components of SSA systems. In particular, combinations of radar systems and optical sensor networks play an outstanding role in SSA programs. At present, Korea operates the optical wide field patrol network (OWL-Net), the only optical system for tracking space objects. However, due to their dependence on weather conditions and observation time, it is not reasonable to use optical systems alone for SSA initiatives, as they have limited operational availability. Therefore, the strategies for developing radar systems should be considered for an efficient SSA system using currently available technology. The purpose of this paper is to analyze the performance of a radar system in detecting and tracking space objects. With the radar system investigated, the minimum sensitivity is defined as detection of a $1-m^2$ radar cross section (RCS) at an altitude of 2,000 km, with operating frequencies in the L, S, C, X or Ku-band. The results of power budget analysis showed that the maximum detection range of 2,000 km, which includes the low earth orbit (LEO) environment, can be achieved with a transmission power of 900 kW, transmit and receive antenna gains of 40 dB and 43 dB, respectively, a pulse width of 2 ms, and a signal processing gain of 13.3 dB, at a frequency of 1.3 GHz. We defined the key parameters of the radar following a performance analysis of the system. This research can thus provide guidelines for the conceptual design of radar systems for national SSA initiatives.

Structural and Optical Properties of ZnO Thin Films Grown on SiO2/Si(100) Substrates by RF Magnetron Sputtering (RF 마그네트론 스퍼터링 방법으로 SiO2/Si(100) 기판위에 성장시킨 ZnO 박막의 구조 및 광특성)

  • Han Seok Kyu;Hong Soon-Ku;Kim Hyo-Jin;Lee Jae-Wook;Lee Jeong-Yong
    • Korean Journal of Materials Research
    • /
    • v.16 no.6
    • /
    • pp.360-366
    • /
    • 2006
  • A series of ZnO thin films were grown by radio-frequency (RF) magnetron sputtering with various RF powers on $SiO_2/Si$(100) substrates at $500^{\circ}C$. Thicknesses of the investigated ZnO films were fixed to about 250nm by changing the growth time based on the changes of growth rates with RF powers. All the ZnO thin films were grown with <0001> preferred orientation. Average grain sizes of about 250nm-thick ZnO films evaluated by FE-SEM, AFM, and TEM were increased by decreasing the RF power. Structural properties addressed by FWHM values of XRD (0002) omega rocking curves and their intensities were better for the smaller grain sized ZnO films grown with high RF powers, which implies small values of tilt for smaller grain sized ZnO films. However, optical properties addressed by intensities of band edge emissions from room temperature and low temperature photoluminescence were better for the larger grain sized ZnO films with low RF power, which implies grain boundaries acted as nonradiation recombination centers.

Fabrication & Characteristics of SIR Microsrip Bandpass Filters using Deposition of High-Tc Superconducting Epitaxial Films (고온 초전도 에피텍셜 박막을 이용한 SIR 마이크로스트립 대역통과 필터의 제작 및 특성연구)

  • Park, Kyung-Kuk;Chung, Dong-Chul;Jeong, Yong-Chae;Lim, Sung-Hun;Yim, Seong-Woo;Han, Byoung-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.326-332
    • /
    • 1999
  • In this paper, we designed and fabricated High-Tc Superconducting (HTS) microstrip bandpass filters using Stepped Impedance Resonators(SIR) and studied on their characteristics. The $high-T_c$ superconducting $Y_1Ba_2Cu_3O_{7-x}$ epitaxial films were deposited by Pulse Laser Deposition (PLD) system on MgO. The fabricated filters were designed so as to operate in Ku band with central frequency 17.25 GHz, bandwidth 2.896% and ripple 0.01 dB. These filters were composed of parallel coupled microstrip SIR of which impedance ratio (K) are 0.5, 1.5. In the measured response, HTS filters had showed insertion loss below -0.5 dB. For comparison with normal conducting filter, we fabricated the Au counterpart that consists of the resonators as K=1.5 in the same dimension and measured performance of the Au filter. In comparison, HTS filter designed optimally got superior response to gold conterpart.

  • PDF

Development of Safety Devices for Marine Leisure (해양레저 안전장비 개발)

  • Ku Ja-Young;Yim Jeong-Bin;Lee Je-Eung;Nam Taek-Keun;Jeong Joong-Sik;Park Seong-Hyeon;Yang Weon-Jae;Ahn Yeong-Sub
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.241-246
    • /
    • 2006
  • This paper describes two kinds of personal hand-held electronic devices to support marine leisure safety. The one is Radar response-type safety device triggering by the pulse signal from a commercial 9GHz-band Radar to provide quick search and rescue with combined civilian-government-military fleets. The other one is M-RFID (Marine Radio Frequency IDentification) based safety electronic device using 900MHz Tx/Rx with spread spectrum frequency hopping and GPS. Through the field tests at sea using Korea Coast Guard's warship the operating performances are verified. Further plan for practical use of each device was also discussed.

  • PDF

Application of Hot Start PCR Method in PCR-based Preimplantation Genetic Diagnosis

  • Kim, Sung-Ah;Kang, Moon-Joo;Kim, Hee-Sun;Oh, Sun-Kyung;Ku, Seung-Yup;Choi, Young-Min;Jun, Jong-Kwan;Moon, Shin-Yong
    • Journal of Genetic Medicine
    • /
    • v.9 no.1
    • /
    • pp.11-16
    • /
    • 2012
  • Purpose: To determine a method to improve the efficacy and accuracy of preimplantation genetic diagnosis (PGD) - polymerase chain reaction (PCR), we compared hot start PCR and conventional multiplex nested PCR. Materials and Methods: This study was performed with single lymphocyte isolated from whole blood samples that were obtained from two couples with osteogenesis imperfecta (OI). We proceeded with conventional multiplex nested PCR and hot start PCR in which essential reaction components were physically removed, and we compared the amplification rate, allele dropout rate and nonspecific products. Afterward, we used selective method for PGD. Results: In the two couples, the respective amplification rate were 93.5% and 80.0% using conventional multiplex nested PCR and 95.5% and 92.0% using hot start PCR. The respective mean allele dropout rates for the two couples were 42.0% and 14.0% with conventional multiplex nested PCR and 36.0% and 6.0% with hot start PCR. Conclusion: The results demonstrate that the hot start PCR procedure provides higher amplification rates and lower allele dropout rate than the conventional method and that it decreased the nonspecific band in multiplex nested PCR. The hot start method is more efficient for analyzing a single blastomere in clinical PGD.

Identification of Deer Antler Species Using Sequence Analysis and PCR-RFLP of Mitochondrial DNA (사슴 미토콘드리아 DNA의 염기서열 및 PCR-RFLP분석에 의한 녹용의 종 감별)

  • Shin, Ki-Hyun;Shin, Sung-Chul;Chung, Ku-Young;Chung, Eui-Ryong
    • Food Science of Animal Resources
    • /
    • v.28 no.3
    • /
    • pp.276-282
    • /
    • 2008
  • It is estimated that over 80% of deer antlers produced in the world are consumed in Korea. However, mislabeling or fraudulent replacement of costly antlers with cheaper ones is one of the most common problems in the domestic antler market. Therefore, there is a great need for the development of technology to identify species of antlers. This study was carried out to develop an accurate and reliable method for the identification and authentication of species or subspecies of antlers using DNA sequence analysis and comparison of mitochondrial cytochrome band D-loop region genes among antlers of five deer species, Cervus elaphus sibericus, Cervus elaphus canadensis, Cervus nippon, Cervus elaphus bactrianus and Rangifer tarandus. A variable region of cytochrome band D-loop genes was amplified using PCR with specifically designed primers and sequenced directly. The cytochrome band D-loop region genes showed different DNA sequences between the species of antlers and thus it is possible to differentiate between species on the basis of sequence variation. To distinguish between reindeer (Rangifer tarandus) antlers and other deer antlers, PCR amplicons of the cytochrome b gene were digested with the restriction enzymes NlaIV and TaqI, respectively, which generates a species-specific DNA profile of the reindeer. In addition, samples of 32 sliced antlers labeled Cervus elaphus sibericus from commercial markets were collected randomly and the mt DNA D-loop region of these antler samples was sequenced. Among the antler samples investigated, only 62.5% were from Cervus elaphus sibericus, and others were from Cervus elaphus bactrianus (25.0%), elk (Cervus elaphus canadensis) and reindeer (Rangifer tarandus). Our results suggest that DNA sequencing of mt DNA and PCR-RFLP methods using NlaIV and TaqI enzymes are useful for the identification and discrimination of deer antler species by routine analysis.

Growth and characterization of MgZnO grown on R-plane sapphire substrate by plasma-assisted molecular beam epitaxy

  • Han, Seok-Kyu;Kim, Jung-Hyun;Hong, Soon-Ku;Lee, Jae-Wook;Lee, Jeong-Yong;Kim, Ho-Jong;Song, Jung-Hoon;Yao, Takafumi
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.114-114
    • /
    • 2009
  • ZnO has received considerable attention due to its potential applicability to optoelectronic devices such as ultraviolet-light emitting diodes (UVLEDs) and laser diodes (LDs). As well known, however, polar ZnO with the growth direction along the c-axis has spontaneous and piezoelectric polarizations that will result in decreased quantum efficiency. Recently, nonpolar ZnO has been studied to avoid such a polarization effect. In order to realize applications of nonpoar ZnO-based films to LEDs, growth of high quality alloys for quantum well structures is one of the important tasks that should be solved. $Mg_xZn_{1-x}O$ and $Cd_xZn_{1-x}O$ is ones of most promising alloys for this application because the alloys of ZnO with MgO and CdO provide a wide range of band-gap engineering spanning from 2.4 to 7.8 eV. In this study, we investigated on $Mg_xZn_{1-x}O$ films grown with various Mg/Zn flux ratios The films were grown on R-plane sapphire substrates by plasma-assisted molecular beam epitaxy (PAMBE). we investigated on $Mg_xZn_{1-x}O$ films grown with various Mg/Zn flux ratios. The films were grown on R-plane sapphire substrates by plasma-assisted molecular beam epitaxy (PAMBE). With the relatively low Mg/Zn flux ratios, a typical striated anisotropic surface morphology which was generally observed from the nonpolar (11-20) ZnO film on r-plane sapphire substrates. By increasing the Mg/Zn flux ratio, however, additional islands were appeared on the surface and finally the surface morphology was entirely changed, which was generally observed for the (0001) polar ZnO films by losing the striated morphology. Investigations by X-ray $\Theta-2{\Theta}$ diffraction revealed that (0002) and (10-11) ZnO planes are appeared in $Mg_xZn_{1-x}O$ films by increasing the Mg/Zn flux ratio. Further detailed investigation by transmission electron microscopy (TEM) and photoluminescence (PL) will be discussed.

  • PDF

Effects of pre-heat treatments on the quality of cut kimchi cabbages during short-term storage (절단배추의 단기 저장에 대한 예열처리 효과)

  • Kim, Sang-Seop;Ku, Kyung-Hyung;Jeong, Moon-Cheol;Hong, Joo-Heon;Chung, Shin-Kyo
    • Food Science and Preservation
    • /
    • v.21 no.6
    • /
    • pp.776-783
    • /
    • 2014
  • Kimchi cabbages were cut ($3{\times}3cm$), and were pre-heat treated at $40^{\circ}C$, and their physicochemical qualities and browning degrees were investigated during 8 weeks storage at $5^{\circ}C$. The Cut kimchi cabbages were treated at $40^{\circ}C$ (1~8 hrs) and their protein bands profiles were determined by sodium dodecyl sulfate polyacrylamide electrophoresis (SDS-PAGE). The 60, 39, 33, and 12 kDa bands considered heat shock proteins (HSPs) were expressed in the cut kimchi cabbage, and the 4-hr pre-heat treatment (HS 4) exhibited the strongest band ratio. The weight ratios and titratable acidities of the pre-heat treated cut kimchi cabbages were not changed so much after 8 weeks storage at $5^{\circ}C$, and the soluble solid contents of HS 4 decreased less than that of any other treatments. The browning degree of HS 4 after 8 week storage was also shown to be the least among the treatments. The polyphenol oxidase (PPO) activities of all treatments slightly rose during the over all storage period, in contrast with the decrease of total phenolic contents. The expression of HSPs was identified in the pre-heat treated cut kimchi cabbages, and HS 4 exhibited the best quality and appearance after 8 weeks storage at $5^{\circ}C$.

DIAGNOSIS OF MICROMETASTASIS IN LYMPH NODE AND CLINICAL EVALUATION OF PROGNOSTIC FACTOR OF ORAL SCC USING RT-PCR AND IMMUNOHISTOCHEMISTRY FOR CYTOKERATIN (Cytokeratin의 RT-PCR 및 면역조직화학적 분석을 이용한 구강편평세포암종의 임파절 미세전이 진단과 예후인자 효용성 평가)

  • Park, Sung-Jin;Lee, Won-Deok;Lim, Ku-Young;Kang, Jin-Han;Myung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.2
    • /
    • pp.105-115
    • /
    • 2005
  • Purpose: The lymph node status assessed by conventional histological examination is the most important prognostic factor in patients undergoing surgery for oral squamous cell carcinoma. The presence of lymph node metastasis has a strong adverse impact on patient survival even after extended radical resection. Despite these findings, tumour recurrence is not rare after surgery, even when histological examination shows no lymph node metastasis. Recently, molecular-genetically and immunohistochemically demonstrated micrometastasis to the lymph nodes has been shown to have a significant adverse influence on survival in patients with squamous cell carcinoma and histologically negative nodes. The present study sought to determine the incidence and clarify the clinical significance of molecular-genetically and immunohistochemically demonstrated nodal micrometastases and to correlate these data with the stage of oral cancer. Methods: Lymph nodes systematically removed from 71 patients who underwent curative resection between 1998 and 2003 with head and neck squamous cell carcinoma were examined molecular-genetically to detect cytokeratin 5 mRNA with RT-PCR and immunohistochemically to detect cells that stained positively for cytokeratins with the monoclonal antibody cocktail AE1/AE3. The postoperative course and survival rates were compared among patients with and without micrometastases, after numerical classification of overt metastatic nodes. Results: micrometastases were detected in 43(60%) of 71 patients by RT-PCR and 26(36%) of 71 patients by immunohistochemistry. By RT-PCR analysis, patients exhibiting a positive band for CK 5 mRNA had a significantly worse prognosis than those were RT-PCR negative. By immunohistochemistry, the presence of micrometastasis did not predict patient outcome. Conclusion: Micrometastases detected by RT-PCR may be of clinical value in identifying patients who may be at high risk for recurrence and who are therefore likely to benefit from systemic adjuvant therapy.